• Title/Summary/Keyword: Harmonic to noise ratio

Search Result 111, Processing Time 0.027 seconds

Problems of Strobovideolarygoscopic Findings and Usual Voice Management of Vocal Major Students, and Acoustic Characteristics of Singing Voice (성악도들의 음성관리 및 성대화상술상의 문제점과 발성에 대한 음향분석학적 특징)

  • 진성민;김대영;반재호;이상혁;송윤경;권기환;이경철;이용배
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.10 no.1
    • /
    • pp.43-49
    • /
    • 1999
  • Objectives : The purpose of this study was to systematically analyze and compare e acoustic sound structure of vocal major student's singing voice. Materials and Methods : The nineteen vocal major students were the subject group and healthy nineteen females were the control group for this study. The subject group was taken a strobovideolaryngoscopy by the use of flexible nasopharyngoscopy. And acoustic analysis was taken between two groups. Additionally the inquiry on usual voice problems and management was performed by thirty-six vocal major students. Results : The subject group presents many functional voice disorder findings such as AP contraction(44%), phase difference(36%) tremor(25%), posterior gap(17%), hyperadduction of vestibular fold(6%), and anterior gap(3%) on strobovideolaryngoscopy. And the vocal major students did reveal an enhanced number of high frequency harmonic partials when singing compared to the control group in the narrow band spectrum study. But there was no significant difference in jitter, shimmer and noise to harmonic ratio in both groups. Almost all vocal major students present a lot of voice problems in singing such as loss of high note(17%), loss of quiet voice(17%), effortful and tired voice(36%) etc on inquiry. And they always effort to prevent vocal dysfunction by the use of various type of method such as voice rest(28%), hydration(28%), gargling with salt(11%) etc. Conclusions : The vocal major students always take care of maintaining a good voice condition, but a lot of vocal major students revealed abnormal strobovideolaryngoscopic findings and they are absent in the conception of systemic and scientific voice management. Therefore, the young singers need a good voice training and voice therapy Program under the good ralationship of laryngologist and voice training teacher.

  • PDF

Dynamic Characteristics of Tuned Liquid Column Dampers Using Shaking Table Test (진동대실험에 의한 동조액체기둥감쇠기의 동적특성)

  • Min, Kyung-Won;Park, Eun-Churn
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.6
    • /
    • pp.620-627
    • /
    • 2009
  • Shaking table test was carried out to obtain dynamic characteristics of TLCDs with uniform and non-uniform sections for both horizontal and vertical tubes. The input to the table is harmonic acceleration with constant magnitude. The output is horizontal dynamic force which is measured by load cell installed below the TLCD. Transfer functions are experimentally obtained using the ratio of input and output. Natural frequency, the most important design factor, is compared to that by theoretical equation for TLCDs with five different water levels. System identification process is performed for experimentally obtained transfer functions to find the dynamic characteristics of head loss coefficient and effective mass of TLCDs. It is found that their magnitudes are larger for a TLCD with non-uniform section than with uniform section and natural frequencies are close to theoretical ones.

Free Vibrations of Arches in Cartesian Coordinates (직교좌표계에 의한 아치의 자유진동)

  • Lee, Byoung-Koo;Lee, Yong-Soo;Kim, Il-Jung;Choi, Kou-Moon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.12 no.12
    • /
    • pp.970-978
    • /
    • 2002
  • The differential equations governing free vibrations of the elastic arches with unsymmetric axis are derived in Cartesian coordinates rather than in polar coordinates. in which the effect of rotatory inertia is included. Frequencies and mode shapes are computed numerically for parabolic arches with both clamped ends and both hinged ends. Comparisons of natural frequencies between this study and SAP 2000 are made to validate theories and numerical methods developed herein. The convergent efficiency is highly improved under the newly derived differential equations in Cartesian coordinates. The lowest four natural frequency parameters are reported, with and without the rotatory inertia, as functions of three non-dimensional system parameters the rise to chord length ratio. the span length to chord length ratio, and the slenderness ratio. Also typical mode shapes of vibrating arches are presented.

Determination of Specimen Geomery for Estimation of the Complex Modulus of Viscoelas the Materials by the Lumped Mass Model (집중질량 모형화에 의한 점탄성재료의 복소 탄성계수 산출을 위한 시편 크기 의 절정)

  • Kang, Gi-Ho;Shim, Song;Kim, Gwang-Jun
    • Journal of KSNVE
    • /
    • v.1 no.2
    • /
    • pp.121-128
    • /
    • 1991
  • In order to use viscoelastic materials efficiently for noise and vibration control, or th qualify newly developed materials, knowledge of the Young' s modulus and loss factor is essemtial. These material properties, the so-called complex Young' s modulus, are frequently treated as dynamic charicteristics because of their dependence upon the frequency. Many techniques have been developed and verified for measuring complex Young' s modulus of viscoelastic materials. Among them, the impedance method is preferable in order to obtain the frequency information in detail. In this method, a cylindrical or prismatic specimen is excited into longitudinal harmonic vibration at one end, the other being fixed, and the resulting force is measured at the driving or fixed end. The amplitude ratio of the two signals and phase angle between them are then used to compute the material properties using various mathematical models. In this paper, the impedance method is investigated theoretically and experimentally. A way to determine the specimen geometry which is most appropriate for the identification of complex Young' s modulus using the lumped mass model is presented and discussed. Then experimental results supporting the theoretical predictions are presented.

  • PDF

Analysis on the Nonlinear Effect in the DS/CDMA Wireless-Optical Transmission System Model (DS/CDMA 무선 광전송시스템 모델에서의 비선형 효과 해석)

  • 주창복;오경석
    • Proceedings of the IEEK Conference
    • /
    • 1998.06a
    • /
    • pp.98-101
    • /
    • 1998
  • The intermodulation distortion(IMD) due to laser diode nonlinearity of an asynhcronous direct sequence code diviion multiple access(DS/CDMA) system in wireless-optical transmission system model is analzed. A third order polynomial is used to represent laser diode nonlinearity. In DS/CDMA system, only one harmonic of the third-order intermodulation term falls on the signal frequency band and influences the system performance characteristics. To cancel multi-user interference and nonlinear distortion in a DS/CDMA wireless-optical transmission system model, the simple transversal filter structure with N-taps of (N-1) tap delay of 1 chip time delay line is used. It is necessary to select an optimal modulation index that provides a maximum signal-to-noise ratio and the results are useful for CDMA system design.

  • PDF

The Effect of Frequency and Intensity of /a/ Phonation on the Result of Acoustic Analysis (발성시 음도 및 강도의 변화가 음성분석검사 결과에 미치는 영향)

  • 손영익;윤영선;권중근;추광철
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.8 no.1
    • /
    • pp.12-17
    • /
    • 1997
  • Measuring phonatory stability using MDVP(Multi-dimensional voice program, Kay Elemetrics Corp., NJ, USA) are becoming popular in many Korean clinics and laboratories, yet questions about standardization and reference values have remained. The purpose of present study was to examine the effects of frequency and intensity variation on the results of acoustic analysis related to phonatory stability. Twenty young adults(ten females and ten males) were asked to sustain vowel /a/ for more than 3 seconds under 9 different pitch and loudness conditions. Using MDVP, nine voice samples were analyzed, and jitter percent, fundamental frequency variation, shimmer percent, peak amplitude variation, noise to harmonic ratio, amplitude tremor intensity index, and degree of subharmonics were compared. The results showed that intensity changes can significantly affect various phonatory stability measures, and the lowest perturbation values can be obtained from slightly louder(10dB) phonatory condition than comfortable level phonation.

  • PDF

Acoustic Qualities of Phonation in Hearing-impaired Male Adults (청각장애 성인 남성의 음성 특성)

  • Sehr, Kyoung-Hee
    • MALSORI
    • /
    • no.65
    • /
    • pp.37-49
    • /
    • 2008
  • The purposes of this experiment were to compare and analyze some voice parameters of the hearing impaired male adults and to suggest a basic data on the speech intervention for the hearing impaired. Voice analysis of four sustained vowels(/a/, /i/, /${\partial}$/, /u/, fundamental Sequency(F0), jitter percent, shimmer percent, and Noise to Harmonic Ratio(NHR) was conducted for the deaf young male adults using a sign laguage(N=5, aged 16-20) and the normal hearing young male adults(N=10, aged 18-20) by using MDVP(Multi-Dimensional Voice Program) in CSL. F0, jitter, and shimmer in the deaf group were significantly higher than those in the normal hearing group. The average of F0 was 151 Hz, which was lower than the results of the previous studies, and there were no significant differences among the sustained vowels. In both groups, the values of the voice parameters were stable on the /a/ or /${\partial}$/, those closed to the standard scores.

  • PDF

THE RELATION BETWEEN HPA AND COMS MULTI-CARRIER

  • Park Durk-Jong;Yang Hyung-Mo;Hyun Dae-Wan;Ahn Sang-Il;Kim Eun-Kyu
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.564-566
    • /
    • 2005
  • The relation between HPA (High Power Amplifier) and COMS (Communication Ocean Meteorological Satellite) multi-carrier is analyzed in this paper. MODAC (Meteorological and Ocean Data Application Center) has a primary mission to transmit processed data, HRIT (High Rate Information Transmission) and LRIT (Low Rate Information Transmission), which is normalized and calibrated by pre-processing. It is also replaced with the SOC (Satellite Operation Center) in emergency case and can transmit the command and ranging tones for operation of COMS. From the result of simulation with modelled HPA, it is found that the multi-carrier in one HPA can give rise to an inter-modulation which makes harmonic and spurious elements increase in-band. Under the environment of these increased parasitic elements, the degradation of multi-carrier's quality is estimated from the ratio of the amount of noise to total output power of HPA.

  • PDF

Automatic carrier phase delay synchronization of PGC demodulation algorithm in fiber-optic interferometric sensors

  • Hou, Changbo;Guo, Shuai
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.14 no.7
    • /
    • pp.2891-2903
    • /
    • 2020
  • Phase-generated carrier (PGC) demodulation algorithm is the main demodulation methods in Fiber-optic interferometric sensors (FOISs). The conventional PGC demodulation algorithms are influenced by the carrier phase delay between the interference signal and the carrier signal. In this paper, an automatic carrier phase delay synchronization (CPDS) algorithm based on orthogonal phase-locked technique is proposed. The proposed algorithm can calculate the carrier phase delay value. Then the carrier phase delay can be compensated by adjusting the initial phase of the fundamental carrier and the second-harmonic carrier. The simulation results demonstrate the influence of the carrier phase delay on the demodulation performance. PGC-Arctan demodulation system based on CPDS algorithm is implemented on SoC. The experimental results show that the proposed algorithm is able to obtain and eliminate the carrier phase delay. In comparison to the conventional demodulation algorithm, the signal-to-noise and distortion ratio (SINAD) of the proposed algorithm increases 55.99dB.

Optical Millimeter-wave Signal Generation using Injection Locking Scheme (광주입 방법을 이용한 밀리미터파 신호 생성)

  • Kim, Jung-Tae
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.7 no.5
    • /
    • pp.1076-1081
    • /
    • 2003
  • A new technique for generating millimeter-wave signals from a semiconductor laser is presented. The method multiples the signal frequency by using optical injection of short optical pulses at a sub-harmonic of the cavity round-trip frequency to drive the laser oscillating at its resonant frequency. A 32GHz signal is generated using a multisection semiconductor laser operated under continuous wave conditions, by injection optical pulses at a repetition rate equal to the fourth subhamonic(8GHz). The generated millimeter-wave signal exhibits a large submamonic suppression ratio(>17 dB), large frequency detuning range (>300 MHz) low levels of phase-noise(-77.5 dBc/Hz), and large locking (>400 MHz)