• Title/Summary/Keyword: Harmonic isolation

Search Result 54, Processing Time 0.022 seconds

Approximate Response of a Non-linear Vibration Isolation System Using the Harmonic Balance Method (하모닉 밸런스법을 이용한 비선형 진동절연 시스템의 근사적 응답)

  • Lee, Gun-Myung
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.6
    • /
    • pp.124-129
    • /
    • 2018
  • A non-linear vibration isolation system which is composed of a non-linear spring and a linear damper was proposed in past research. When the support of the isolation system is excited harmonically, the response component of the isolation system mass at the excitation frequency has been calculated approximately using the harmonic balance method. The response was approximated by a single mode, and the result was compared with a numerical result which is assumed as an accurate one. Next, the response was approximated by two modes, and the result was compared with the former one.

The Design of a Sub-Harmonic Dual-Gate FET Mixer

  • Kim, Jeongpyo;Lee, Hyok;Park, Jaehoon
    • Journal of electromagnetic engineering and science
    • /
    • v.3 no.1
    • /
    • pp.1-6
    • /
    • 2003
  • In this paper, a sub-harmonic dual-gate FET mixer is suggested to improve the isolation characteristic between LO and RF ports of an unbalanced mixer. The mixer was designed by using single-gate FET cascode structure and driven by the second harmonic component of LO signal. A dual-gate FET mixer has good isolation characteristic since RF and LO signals are injected into gatel and gate2, respectively. In addition, the isolation characteristic of a sub-harmonic mixer is better than that of a fundamental mixer due to the large frequency separation between the LO and RF frequencies. As RF power was -30 ㏈m and LO power was 0 ㏈m, the designed mixer yielded the -47.17 ㏈m LO-to-RF leakage power level, 10 ㏈ conversion gain, -2.5 ㏈m OIP3, -12.5 ㏈m IIP3 and -1 ㏈m 1 ㏈ gain compression point. Since the LO-to-RF leakage power level of the designed mixer is as good as that of a double-balanced mixer, the sub-harmonic dual-gate FET mixer can be utilized instead.

Design of a sub-harmonic dual-gate FET mixer for IMT-2000 base-station

  • Kim, Jeongpyo;Park, Jaehoon
    • Proceedings of the IEEK Conference
    • /
    • 2002.07b
    • /
    • pp.1046-1049
    • /
    • 2002
  • In this paper, a sub-harmonic dual-gate FET mixer for IMT-2000 base-station was designed by using single-gate FET cascode structure and driven by the second order harmonic component of LO signal. The dual-gate FET mixer has the characteristic of high conversion gain and good isolation between ports. Sub-harmonic mixing is frequently used to extend RF bandwidth for fixed LO frequency or to make LO frequency lower. Furthermore, the LO-to-RF isolation characteristic of a sub-harmonic mixer is better than that of a fundamental mixer because the frequency separation between the RE and LO frequency is large. As RF power is -30dBm and LO power is 0dBm, the designed mixer shows the -47.17dBm LO-to-RF leakage power level, 10dB conversion gain, -0.5dBm OIP3, -10.5dBm IIP3 and -1dBm 1dB gain compression point.

  • PDF

High Conversion Gain and Isolation Characteristic V-band Quadruple Sub-harmonic Mixer (고 변환이득 및 격리 특성의 V-band용 4체배 Sub-harmonic Mixer)

  • Uhm, Won-Young;Sul, Woo-Suk;Han, Hyo-Jong;Kim, Sung-Chan;Lee, Han-Shin;An, Dan;Kim, Sam-Dong;Park, Hyung-Moo;Rhee, Jin-Koo
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.40 no.7
    • /
    • pp.293-299
    • /
    • 2003
  • In this paper, we have proposed a high conversion and isolation characteristic V-band quadruple sub-harmonic mixer monolithic circuit which is designed and fabricated for the millimeter wave down converter applications. While most of the sub-harmonic mixers use a half of fundamental frequency, we adopt a quarter of the fundamental frequency. The proposed circuit is based on a sub-harmonic mixer with APDP(anti-parallel diode pair) and the 0.1 ${\mu}{\textrm}{m}$ PHEMT's (pseudomorphic high electron mobility transistors). Lumped elements at IF port provide better selectivity of IF frequency and increase isolation. Maximum conversion gain of 0.8 ㏈ at a LO frequency of 14.5㎓ and at a RF frequency of 60.4 ㎓ is measured. Both LO-to-RF and LO-to-IF isolations are higher than 50 ㏈. The conversion gain and isolation characteristic are the best performances among the reported quadruple sub-harmonic mixer operating in the V-band millimeter wave frequency thus far.

Design and Fabrication of K Band Push-Push Dielectric Resonator Oscillator (K 대역 Push-Push 유전체 공진기 발진기 설계 및 제작)

  • 정재권;박승욱;김인석
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.7
    • /
    • pp.613-624
    • /
    • 2002
  • Electrical characteristics of two types of 20 GHz Push-Push GaAs MESFET dielectric resonator oscillators having Wilkinson and T-junction power combiners for the output stage have been investigated and compared. So we have explained that the output power and phase noise properties of the Push-push FET DRO are depending on return loss and isolation characteristics of power combiner at the fundamental and the second harmonic frequencies. A Push-push oscillator for suppressing the fundamental frequency of 10 GHz and enhancing the second harmonic of 20 GHz has been designed and fabricated in microstrip configuration on 20 mil thick RT-Duroid($\varepsilon$$_{r}$ = 2.52) Teflon substrate. Return loss and isolation characteristics of T-junction and Wilkinson have been measured at the fundamental frequency of 10.2 GHz and the second harmonic frequency of 20.5 GHz. At the fundamental frequency, -12 dB return loss and -3.7 dB isolation have been measured for the T-junction power combiner, and -14 dB return loss and -11 dB isolation fur the Wilkinson power combiner. At the second harmonic frequency, -10 dB return loss and -7.5 dB isolation have been obtained for the T-junction power combiner, and -23 dB return loss and -22 dB isolation for the Wilkinson power combiner. As a result, we have confirmed that the oscillator based on the Wilkinson power combiner with better retrun loss and isolation characteristics produces more output power and better phase noise characteristics..

Methods to Obtain Approximate Responses of a Non-Linear Vibration Isolation System (비선형 진동절연 시스템의 근사적 응답을 구하는 방법)

  • Lee, Gun-Myung
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.6
    • /
    • pp.23-28
    • /
    • 2020
  • A non-linear vibration isolation system composed of a non-linear spring and a linear damper was presented in a previous study. The advantage of the proposed isolator is the simple structure of the system. When the base of the isolator is harmonically excited, the response component of the mass at the excitation frequency was approximated using three different methods: linear approximation, harmonic balance, and higher-order frequency response functions (FRFs). The method using higher-order FRFs produces significantly more accurate results compared with the other methods. The error between the exact and approximate responses does not increase monotonously with the excitation amplitude and is less than 2%.

Performance Evaluation of RWA Vibration Isolator Using Notch Filter Control (노치 필터 제어기법을 이용한 반작용 휠 미소진동 절연장치의 절연성능 평가)

  • Park, Geeyong;Suh, Jong-Eun;Lee, Dae-Oen;Han, Jae-Hung
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.26 no.4
    • /
    • pp.391-397
    • /
    • 2016
  • Vibration disturbances induced by the reaction wheels can severely degrade the performance of high precision payloads on board satellites with high pointing stability requirements. The unwanted disturbances produced by the reaction wheels are composed of fundamental harmonic disturbances due to the flywheel imbalance and sub/higher harmonic disturbances due to bearing irregularities, motor imperfections and so on. Because the wheel speed is constantly changed during the operation of a reaction wheel, the vibration disturbance induced by the reaction wheels can magnify the satellite vibration when the rotating frequency of wheel meets the natural frequency of satellite structure. In order to provide an effective isolation of the reaction wheel disturbances, isolation performance of a hybrid vibration isolator is investigated. In this paper, hybrid vibration isolator that combines passive and active components is developed and its hybrid isolation performance using notch filter control is evaluated in single-axis. The hybrid isolation performance using notch filter control show additional performance improvement compared to the results using only passive components.

Seismic isolation of hospital buildings

  • Soldatova, Liudmila;Jumukov, Sulaiman
    • Smart Structures and Systems
    • /
    • v.2 no.4
    • /
    • pp.329-337
    • /
    • 2006
  • This paper illustrates an analytical investigation of the vibration parameters of buildings on sliding seismic isolation bearings with elastic limiters of the relative displacement. The installation scheme of sliding bearings and elastic limiters for the separate unit of a 4 storey hospital building with brick walls is designed. The analysis of the vibrations of the hospital building is conducted for harmonic base excitation.

A Study on the downconverter Using Sub-Harmonic Mixer for Point to Point System Applications (Sub-Harmonic 혼합기를 이용한 점대점 시스템용 하향 변환기에 관한 연구)

  • Min Jun-Ki;Kim Hyun-Jin;Kim Yong-Hwan;Yoo Hyung-Soo;Yun Ho-Seok;Lee Keun-Tae;Hong Ui-Seok
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.10A
    • /
    • pp.958-964
    • /
    • 2005
  • In this thesis, the matching network at the local oscillator port of the sub-harmonic mixer is optimized for reducing the conversion loss. A downconverter for point to point system applications is designed and fabricated using the such sub-harmonic mixer. The sub-harmonic mixer achieved the conversion loss of 11.8 dB at the 12 dBm input power of the local oscillator and the isolation of less than -40 dB. The downconverter achieved the IF output power flatness of 2 dB and the total noise figure of 5.9 dB.

Design of Sub-Harmonics Pumped Ring Mixer (SHP 링혼합기 설계)

  • 김갑기;박용식;최충연;최병하
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.11 no.8
    • /
    • pp.1392-1398
    • /
    • 2000
  • In this paper, Sub Harmonic Ring Mixer using Anti-Parallel Diode Pair is studied. Conventional mixers mix LO signal with RF signal and, obtain IF signal from the difference between LO and RF. Sub harmonic ring mixers using APDP mix RF signal with the second harmonic of LO signal, LO frequency needed for conventional receiver is reduced by 1/2.The produced mixer showed 12 dB conversion loss, and 1 dB compression point of IF signal, in respect to RF signal, was found at the 0 dBm RF signal. Isolation LO/IF and LO/RF is 24.6 dB and 22.5 dB respectively. Isolation RF/LO and LO/RF is 32.6 dB and 22.5 dB respectively.

  • PDF