• Title/Summary/Keyword: Harmonic current injection

Search Result 57, Processing Time 0.019 seconds

A New Injection Method of Harmonic Compensation Current by Active AC Power Filter (능동형 교류 전력 필터에 의한 고조파 보상전류의 새로운 주입방식)

  • 박민호;최규하
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.34 no.9
    • /
    • pp.361-367
    • /
    • 1985
  • A new injection method is proposed for active power filters to eliminate AC harmonics in ac input current of nonlinear loads such as rectifiers. By injecting the PWM current determined by the proposed injection method, all the harmonics up to order nn can be eliminated to exactly zero. This PWM injection current can be generated by sampling total harmonic wave at the rate of M and the sampled values are converted into the proposed PWM wave with N pulse-width variables and adjustable current magnitude Im. These variables are deetermined by solving a set of N nonlinear harmonic equations and the harmonic-elimination characteristics of the new injection are investigated through digital computer sinmulation. Also by comparing between the simulated results and the ones synthesized by data stored in EPROM, the possibility of the suggested injection method can be shown.

  • PDF

Novel Third Harmonic Current Injection Technique for Harmonic Reduction of Controlled Converters

  • Eltamaly, Ali M.
    • Journal of Power Electronics
    • /
    • v.12 no.6
    • /
    • pp.925-934
    • /
    • 2012
  • Three-phase controlled converters have many applications in the utility interfacing of renewable energy sources and adjustable speed drives as a rectifier or inverter. The utility line currents of these converters have a high harmonic distortion, which is more than the harmonic standards. This paper introduces a new technique for circulating the third harmonic currents from the dc-link to the line currents to reduce their harmonic contents. The proposed system uses a single-phase PWM converter to control the angle and amplitude of the injection current for each of the firing angle of a three-phase converter. A detailed analysis is introduced to achieve a relationship between the firing angle of the three-phase controlled converter and the power angle of the PWM converter. In addition, a detailed design for the other injection path components is introduced. A simulation and experimental work is introduced to prove the mathematical derivations. Analysis, simulation and experimental results prove the superiority of the proposed technique.

Torque Ripple Reduction for Permanent Magnet Synchronous Motor using Harmonic Current Injection (고조파 전류를 이용한 영구자석형 동기 전동기의 토크 리플 저감)

  • Kwon, Soon-O;Lee, Jeong-Jong;Lee, Geun-Ho;Hong, Jung-Pyo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.10
    • /
    • pp.1930-1935
    • /
    • 2009
  • This paper deals with the torque ripple reduction of permanent magnet synchronous motor using harmonic current injection. Torque ripple of electric motor reduces system stability and performances, therefore efforts to reduce torque ripple are exerted in the design process. Torque ripple can be reduced by appropriate pole/slot combination, skew of rotor or stator, design of magnetic circuit, etc. In addition, torque ripple can be also reduced by input voltage and current, and many researches have been conducted to reduce torque ripple for six-step drive. Torque ripple reduction for current vector controlled permanent magnet synchronous motor also have been conducted and verified by investigating back emf wave form. Torque ripple reduction in this paper started from getting torque profile according to input current and electrical angle calculated by FEA, then instantaneous currents at each electrical angles for constant torque are calculated and applied to experiments. Therefore, 0% of torque ripple can be obtained theoretically with harmonic current injection. In order to maximize the effect of torque ripple reduction, a BLDC motor having high harmonic component of back emf is chosen. With sinusoidal current drive, over 100% of torque ripple is obtained initially, then 0.5 % of torque ripple is obtained by FEA using harmonic current injection. The effect is verified by experiment and the presented method can be effectively applicable to Electric Power Steering(EPS).

Analysis of Optimized Injection Method for Active Power Filter of Current Injection Type (전류주입식 능동전력 필터를 위한 최적주입방법의 해석)

  • 박민호;최규하
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.35 no.7
    • /
    • pp.296-303
    • /
    • 1986
  • The active filter of current injection type is the device which eliminates the harmonics in ac line by injecting the harmonic compensating current into the ac side. And its harmonic reduction performance is entirely dependent on the control scheme of the current-fed inverter and the harmonic compensating current becomes the PWM wave by the inverter. This PWM compensating current can be determined by selecting the switching function properly which eliminates the harmonics up to any order with using no independent sources. The new injection current model is derived by the proposed method which is called the optimized injection method. The overall characteristics of the proposed method are investigated through digital computation and the feasibility is proved with experimental results obtained from the Z-80 microcomputer control of the active filter.

  • PDF

Islanding Prevention Method for Photovoltaic System by Harmonic Injection Synchronized with Exciting Current Harmonics of Pole Transformer

  • Yoshida, Yoshiaki;Fujiwara, Koji;Ishihara, Yoshiyuki;Suzuki, Hirokazu
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.3 no.3
    • /
    • pp.331-338
    • /
    • 2014
  • When large penetration of the distributed generators (DGs) such as photovoltaic (PV) systems is growing up in grid system, it is important to quickly prevent islanding caused by power system fault to ensure electrical safety. We propose a novel active method for islanding prevention by harmonic injection synchronized with the exciting current harmonics of the pole transformer to avoid mutual interference between active signals. We confirm the validity of the proposed method by performing the basic tests of islanding by using a current source superimposed the harmonic active signal. Further, we carry out the simulation using PSCAD/EMTDC, and verify the fast islanding detection.

Islanding Detection Method for Inverter-Based Distributed Generation through Injection of Second Order Harmonic Current

  • Lee, Yoon-Seok;Yang, Won-Mo;Han, Byung-Moon
    • Journal of Power Electronics
    • /
    • v.18 no.5
    • /
    • pp.1513-1522
    • /
    • 2018
  • This paper proposes a new islanding detection method for inverter-based distributed generators by continuously injecting a negligible amount of 2nd order harmonic current. The proposed method adopts a proportional resonant (PR) controller for the output current control of the inverter, and a PR filter to extract the 2nd order harmonic voltage at the point of common coupling (PCC). The islanding state can be detected by measuring the magnitude ratio of the 2nd order harmonic voltage to the fundamental voltage at the PCC by injecting a 2nd order harmonic current with a 0.8% magnitude. The proposed method provides accurate and fast detection under grid voltage unbalance and load unbalance. The operation of the proposed method has been verified through simulations and experiments with a 5kW hardware set-up, considering the islanding test circuit suggested in UL1741.

Third Harmonic Injection Circuit to Eliminate Electrolytic Capacitors in Light-Emitting Diode Drivers

  • Yoo, Jin-Wan;Jung, Kwang-Hyun;Jeon, In-Ung;Park, Chong-Yeun
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.3
    • /
    • pp.358-365
    • /
    • 2012
  • A new third harmonic injection circuit for light-emitting diode (LED) drivers is proposed to eliminate electrolytic capacitors and thereby extend the lifetime of LED drivers. When a third harmonic current is injected to the input current of the LED driver, the required capacitance of the driver can be reduced. The proposed circuit can control an injection ratio and has simple circuitry. The synchronous third harmonic is generated by a phase locked loop (PLL), a 1/3 counter, and op-amps and applied to a power factor correction circuit. Thus, the storage capacitor can install film capacitors instead of the electrolytic capacitor. The value of storage capacitance can be reduced to 78% compared to an input power factor of 100%. The proposed circuit is applied to the 80W prototype LED driver to experimentally verify the performances.

Harmonic Reduction of Diode Rectifiers by a New Zero-Sequence Current Injection Method (새로운 영상전류 주입법에 의한 다이오드 정류기의 고조파 저감)

  • 김현정;장민수;최세완;원충연;김규식
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.7 no.6
    • /
    • pp.596-603
    • /
    • 2002
  • In this paper a new harmonic reduction method of three-phase diode rectifiers is proposed to improve input current performance using the zero-sequence harmonics injection technique. The proposed mothed, based on the third-harmonic injection, employs two half-bridge inverters and two single-phase transformers to independently shape the positive and negative dc rail currents of the diode rectifier. The actively shaped zero-sequence harmonic currents are t]ten circulated through the ac side of the rectifier using a zigzag transformer This results in pure sinusoidal input currents in the three-phase diode rectifier. Experimental results on a 1.5kVA prototype are provided to validate the proposed technique.

New Techniques for Impedance Characteristics Measurement of Islanded Microgrid based on Stability Analysis

  • Hou, Lixiang;Zhuo, Fang;Shi, Hongtao
    • Journal of Power Electronics
    • /
    • v.16 no.3
    • /
    • pp.1163-1175
    • /
    • 2016
  • In recent years, microgrids have been the focus of considerable attention in distributed energy distribution. Microgrids contain a large number of power electronic devices that can potentially cause negative impedance instability. Harmonic impedance is an important tool to analyze stability and power quality of microgrids. Harmonic impedance can also be used in harmonic source localization. Precise measurement of microgrid impedance and analysis of system stability with impedances are essential to increase stability. In this study, we introduce a new square wave current injection method for impedance measurement and stability analysis. First, three stability criteria based on impedance parameters are presented. Then, we present a new impedance measurement method for microgrids based on square wave current injection. By injecting an unbalanced line-to-line current between two lines of the AC system, the method determines all impedance information in the traditional synchronous reference frame d-q model. Finally, the microgrid impedances of each part and the overall microgrid are calculated to verify the measurement results. In the experiments, a simulation model of a three-phase AC microgrid is developed using PSCAD, and the AC system harmonic impedance measuring device is developed.

A Study on the Analysis of Harmonic Injection and Emission for Power System (전력계통 고조파 유입 유출 분석에 관한 연구)

  • Wang, Yong-Peel;Jeong, Jong-Won;Kim, Se-Dong;Kwak, No-Hong;Jeon, Young-Soo;Park, Sang-Ho
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.203-205
    • /
    • 2007
  • A method is proposed in this paper to determine the harmonic contributions of a customer at the point of common coupling. The method can quantify customer and utility responsibilities for limit violations caused by either harmonic source changes or harmonic impedance changes. It can be implemented in current power quality monitors and digital revenue meters. The method is comparison of measurement phase angles between harmonic voltage and current. The proposed method has been applied to the test system. The study results have indicated the accuracy of harmonic injection and emission for customer and utility.

  • PDF