• Title/Summary/Keyword: Harmonic component

Search Result 365, Processing Time 0.029 seconds

A Study on the Tidal Characteristics of the Nakdongpo Estuary (낙동포의 조석특성에 관한 연구)

  • 전승환;전홍선
    • Journal of the Korean Institute of Navigation
    • /
    • v.7 no.2
    • /
    • pp.47-63
    • /
    • 1983
  • In this paper, we have investigated the tidal characteristics of the Nakdongpo estuary. We have carried out the analysis of harmonic constant with the use of the recorded data on tidal level at the Gadeong Do tide station and analyzed the flow velocity data obtained by ourselves at two points in the Nakdongpo estuary. In addition, we have analyzed the variation of the mean-sea level. Typical items of the characteristics we have found are; (1) The principal harmonic constants and non-harmonic constants are shown in table 2. (2) Tide in this area shows the semidiurnal inequality. (3) The mean-sea level is shown to be depressed at the rate of about 1cm to the rise of 1 mbar of the atmospheric pressure. (4) (i) At $K_2$ point, The E-W component of the velocty reveals the nature of progressive waves. The N-S component reveals the nature of stationary waves. (ii) At $K_3$ point, The E-W component shows the characteristics of progressive waves to some degree. The N-S component shows a weak hint of stationary waves. (5) At $K_2$ point, S-component is predominant due to the flow of river. At $K_3$ point, E-component is predominant due to the Tsushima current.

  • PDF

Vector Control System of Induction Motor Using the Third Harmonic Component of the Stator Voltage (고정자 전압의 제3고조파 성분을 이용한 유도전동기의 벡터제어 시스템)

  • Ro, Ea-Sug;Jung, Jong-Jin;Kim, Heung-Geun
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.479-481
    • /
    • 1994
  • A direct vector control system of induction machine based determination of the spatial position of the airgap flux from the third harmonic component of the stator voltage is presented in this paper. The Rotor flux, necessary in direct vector control system, is estimated with the stator current and the airgap flux acquired from the third harmonic component of the stator voltage. And it will be used as an important information to implement the vector control system of the induction motor drive.

  • PDF

Digital Relaying Algorithm for Power Transformer Protection using Fuzzy Logic Approach

  • Park, Chul-Won;Shin, Myong-Chul
    • KIEE International Transactions on Power Engineering
    • /
    • v.2A no.4
    • /
    • pp.153-159
    • /
    • 2002
  • Power transformer protective relay should block the tripping during magnetizing inrush and rapidly operate the tripping during internal faults. Recently, the frequency environment of power system has been made more complicated and the quantity of 2nd frequency component in inrush state has been decreased because of the improvement of core steel. And then, traditional approaches will likely be maloperate in the case of magnetizing inrush with low second harmonic component and internal faults with high second harmonic component. This paper proposes a new relaying algorithm to enhance the fault detection sensitivities of conventional techniques by using a fuzzy logic approach. The proposed fuzzy based relaying algorithm consists of flux-differential current derivative curve, harmonic restraint, and percentage differential characteristic curve. The proposed relaying was tested with relaying signals obtained from EMTP simulation package and showed a fast and accurate trip operation.

Compensation of Source Voltage Unbalance and Current Harmonics in Series Active and Shunt Passive Power Filters

  • Lee G-Myoung;Lee Dong-Choon
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.586-590
    • /
    • 2001
  • In this paper, a novel control scheme compensating source voltage unbalance and harmonic currents for hybrid active power filters is proposed, where no low/high-pass filters are used in compensation voltage composition. The phase angle and compensation voltages for source harmonic current and unbalanced voltage components are derived from the positive sequence component of the unbalanced voltage set, which is simply obtained by using digital all-pass filters. Since a balanced set of the source voltage obtained by scaling the positive sequence components is used as reference values for source current and load voltage, it is possible to eliminate the necessity of low/high-pass filters in the reference generation. Therefore the control algorithm is much simpler and gives more stable performance than the conventional method. In addition, the source harmonic current is eliminated by compensating for the harmonic voltage of the load side added to feedback control of the fundamental component.

  • PDF

Dead Time Compensation Scheme Independent of Parameter Variations in an Inverter-fed PMSM Drive (파라미터 변화에 무관한 인버터 구동 PMSM의 데드타임 보상 기법)

  • Kim, Kyeong-Hwa
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.4
    • /
    • pp.124-134
    • /
    • 2011
  • A new dead time compensation scheme that can exactly estimate the dead time and inverter nonlinearity under parameter variations is proposed for a PWM inverter-fed PMSM drive. The proposed scheme uses the fact that the sixth harmonic component in total disturbance estimated under the presence of various uncertainties is mainly caused by the dead time and inverter nonlinearity. The total disturbance due to the parameter variations as well as the dead time and inverter nonlinearity is estimated by the adaptive scheme. The sixth harmonic component is extracted from this total disturbance through harmonic analysis. The obtained sixth harmonic is processed by the PI controller to estimate the disturbance caused by the dead time and inverter nonlinearity in the stationary reference frame. The effectiveness of the proposed scheme is verified. Without requiring an additional hardware, the proposed scheme can effectively compensate the dead time and inverter nonlinearity even under the parameter variations.

Characteristics Leakage Current of Surface Discharge according to Kaolin Contamination by Deteriorated Polymer Insulators (열화된 고분자애자의 카올린 오손에따른 표면방전특성)

  • Park, Jae-Jun;Ga, Pyung-Hyun;Seo, Ui-Won;Jung, Myeong-Yeon;Song, Il-Kwen;Kim, Hee-Dong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.1100-1103
    • /
    • 2004
  • The paper presents the results of using the fundamental and the low frequency harmonic components of leakage current to study aging of EPDM insulator for contaminated condition by kaolin. The largeer the leakage current during 200ms, the higher harmonic component at 60hz. The harmonic component at 60hz and the odd order harmonics is increase relation without Kaolin Conent. Arcing on the surface was always associated with distortion in the leakage current; hence the low frequency components of the leakage currnent can be used as a means to evaluate the surface degration. Both the fundamental and 3rd & 5th harmonics increase dry-band activity.

  • PDF

Comparative Study between the Finger Photoplethysmographic Waveform of the Old and That of the Young Whose Harmonics Deceased with Notch Filtration (고조파 성분 여과 전후의 지첨용적맥파 파형의 비교)

  • Nam, Tong-Hyun;Shin, Sang-Hoon;Park, Young-Jae;Park, Young-Bae
    • The Journal of Korean Medicine
    • /
    • v.29 no.2
    • /
    • pp.60-70
    • /
    • 2008
  • Objectives: The aim of the present investigation was to determine whether the finger photoplethysmography (PPG) of the young will become analogous to those of the old when the PPG harmonic components in the young decrease. Methods: The PPG was measured in 46 old men (21 males and 25 females) over the age of 60 years and 10 young men (5 males and 5 females). We acquired the representative pulse waveform of old men by averaging the PPG waveforms measured in the old men. after the PPG harmonic components in the young men were diminished with notch filtering, we compared the representative pulse waveform of old men and those of the young men. Results: The PPG waveform of the young males became analogous to the representative pulse waveform of the old as the PPG harmonic components in the young were diminished with notch filtering. Especially after the second harmonic component in the young was diminished with notch filtering, increase of the Pearson's correlation coefficient was prominent. On the other hand, the Pearson's correlation coefficient between the PPG waveforms of the young females and that of the old deceased after the second harmonic component diminished in the young. Conclusions: Decrease of the second harmonic component may be a precondition of typical age-related change of the pulse waveform in the healthy male.

  • PDF

Harmonics Modelling for Distribution System (배전시스템 고조파 모델링에 관한 연구)

  • Han, Hyeng-J.;Wang, Yong-P.;Chong, Hyeng-H.;Sung, Byung-H.;Park, Hee-C.;Park, In-P.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.205-207
    • /
    • 2005
  • In this paper, the Point of Common Coupling (PCC) is selected to analyze harmonic characteristic of distribution system by IEC 61000 - 3 - 6 in Electromagnetic Compatibility(EMC). Harmonic voltage and current were measured at the PCC of real distribution system. Harmonic distribution, nonlinear load component and Total Harmonic Distortion(THD) were verified by measurement. The effective and accurate modelling of real distribution system were proved through a analysis of harmonic impedance, voltage and current in steady-state. Harmonic transfer characteristic in distribution system were summarized and investigated through a analysis of harmonic voltage and harmonic current in harmonic current source.

  • PDF

Ac Hysteresis Loop Depending on the Phase Angle of the Higher Harmonic Induction

  • derac Son;Eun Kyoung Kim
    • Journal of Magnetics
    • /
    • v.1 no.2
    • /
    • pp.90-93
    • /
    • 1996
  • For the design of high efficiency electric machines, analysis of higher harmonic frequency components of the magnetic induction is necessary. We have measured ac magnetic properties of non-oriented silicon steel under harmonic frequencies ranging from $3^rd$ (180 Hz) to $9^th$(540 Hz) and harmonic amplitude components from 10% to 50% of the total amplitude ($B_max$=1.5T). From the experiment, it is found that, if the magnetic induction waveform has above $9^th$ harmonic frequency components of the magnetic induction, the core losses only depended on the harmonic amplitude component, but if harmonic frequency becomes lower than 9th harmonic frequency, the core losses depend on the phase angle and the harmonic amplitude, and phase angle should be considered in the design of electric machine.

  • PDF

Novel Oscillator Incorporating a Compact Microstrip Ring Type Resonant Cell with High Efficiency and Superior Harmonic Characteristics

  • Hwang Cheol-Gyu;Myung Noh-Hoon
    • Journal of electromagnetic engineering and science
    • /
    • v.5 no.2
    • /
    • pp.92-96
    • /
    • 2005
  • This paper presents a novel microwave oscillator incorporating a simple microstrip ring type resonant cell as its terminating resonance component. Reduced chip size, higher dc-ac power efficiency, superior harmonic characteristics can be achieved from the introduction of a compact microstrip ring resonator cell. The oscillator provides a second harmonic suppression of 26.51 dB and the output power of 2.046 dBm at 2.11 GHz.