• 제목/요약/키워드: Harmonic analysis

검색결과 1,735건 처리시간 0.03초

Using harmonic class loading for damage identification of plates by wavelet transformation approach

  • Beheshti-Aval, S.B.;Taherinasab, M.;Noori, M.
    • Smart Structures and Systems
    • /
    • 제8권3호
    • /
    • pp.253-274
    • /
    • 2011
  • In this paper, the harmonic displacement response of a damaged square plate with all-over part-through damage parallel to one edge is utilized as the input signal function in wavelet analysis. The method requires the properties of the damaged plate, i.e., no information about the original undamaged structure is required. The location of damage is identified by sudden changes in the spatial variation of transformed response. The incurred damage causes a change in the stiffness or mass of the plate. This causes a localized singularity which can be identified by a wavelet analysis of the displacement response. In this study via numerical examples shown by using harmonic response is more versatile and effective compared with the static deflection response, specially in the presence of noise. In the light of the obtained results, suggestions for future work are presented and discussed.

확률론적 방법을 이용한 교류 고속철도 시스템의 고조파 해석 (Harmonics Analysis of AC High Speed Railroad(HSR) System using Probabilistic Approach)

  • 송학선;이준경;김진오;김형철
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 춘계학술대회 논문집
    • /
    • pp.782-787
    • /
    • 2005
  • Magnitude of generated harmonic currents along with the operation of AC traction has nonlinear characteristics, and generated harmonic currents for high speed traction are more and more in high speed railroad(HSR) systems, especially. This paper presents probabilistic approximation method for the harmonic currents analysis about the operating speed of AC traction. To use probabilistic method for HSR system, probability density function(PDF) for collected operating speed based measure data is calculated. Mean and variance of harmonic currents of single traction are obtained based on the operating speed PDF and electrical traction model. The results of Monte Carlo Simulation(MCS) are in well accordance with the experimental and analytic methods. The harmonics of different number of trainloads are systematically investigated. It is assessed by the total demand distortion(TDD) for the HSR system.

  • PDF

DH Laser Diode의 Threshold Current에 대한 2차 고조파 왜곡의 이론적 해석 (Theoretical Analysis of Second Harmonic Distortion for Threshold Current in DH Laser Diode)

  • 김성일;박한규
    • 대한전자공학회논문지
    • /
    • 제17권2호
    • /
    • pp.10-14
    • /
    • 1980
  • 본 논문에서는 DH-laser diode의 threshold current를 계산하기 위하여 2차고조파 왜곡 (se cond harmonic distortion)에 대해 Rate 방정식 (Rate-equation)을 동적상태와 정적상태 방정식으로 연릴하여 계산하였다. 특히 고조파 왜곡 ( )을 계산하는데 바이어스 전류 에 대하여 변조 전류 을 변조계수 m으로 놓고 (Jm=mJo)계산하여 주입전류 J가 Jth에서 2차 고조파 왜곡이 최대치를 가짐을 보여 ,이제까지 알려진 Jth조사 방법보다 간편하고 정확하게 조사할 수 있음을 제시하였다.

  • PDF

ISG용 매입형 영구자석 동기 전동기 무부하 선간 역기전력 고조파 저감설계 (The Harmonic Reduction Design of IPMSM No-load line-line Back-EMF for ISG)

  • 이진규;정재우;김성일;홍정표
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.754-755
    • /
    • 2008
  • This paper presents a method for reducing the Total Harmonic Distortion(THD) of line-line back_EMF of the IPMSM with distributed winding under the no-load condition. Firstly, the specific harmonic components of line-line back EMF are reduced considering with winding factor. Secondly, THD of line-line back EMF is minimized according to change of pole angle using by Space harmonic Analysis. Finally, the optimal design for minimizing the THD is conducted using response surface methodology with finite element analysis. The validity of the design method dealt with in this paper is demonstrated by comparison between the THD of optimal model and initial model.

  • PDF

경부고속전철 시험선로의 고조파 해석을 위한 10단자 회로망 모델 (8-Port Network Model for Harmonic Analysis on the Test Track in Seoul-Pusan High-Speed Railway)

  • 오광해;이한민;창상훈;김정훈
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제51권3호
    • /
    • pp.99-106
    • /
    • 2002
  • This study presents an approach to model the Electric Railway System with the common grounding based on the 8-port network model and to analyse traction power feeding system focused on the amplification of harmonic current. The entire system can be easily modeled by the combination of 8-port representation of each component in parallel and/or series. Through the research, 8-port network model which can be effectively applied to harmonic analysis is derived.

전력계통 연계형 태양광 발전시스템의 고조파 및 플리커의 측정 및 분석에 관한 연구 (A Study on the Harmonics and Flicker Measurements and Analysis of the Grid Connected Photovoltaic Power System)

  • 김경철;김용관
    • 조명전기설비학회논문지
    • /
    • 제26권5호
    • /
    • pp.48-57
    • /
    • 2012
  • This paper analyzes the characteristic of gird connected photovoltaic power generation system which is available to connect the utility. Renewable energy photovoltaic power system has been linked to the system to analyze the impact of photovoltaic system. It is measured that power data for the Grid connected photovoltaic power plant with instantaneous measuring and 3-sec measuring for 7 days. Harmonic field measurements have shown that the harmonic contents of a waveform varies with time. A cumulative probability approach is the most commonly used method to solve time varying harmonics. So, it is used 50[%] cumulative probability approach. This paper provides an in depth analysis on power quality field measurement of the Grid connected photovoltaic power plant.

EMTDC를 이용한 시송전계통의 고조파공진 분석 (Analysis of the Harmonic Resonance in Primary Restorative Transmission Systems Using EMTDC)

  • 이경섭;박성민;송인준;이남호;배주천;황봉환;이흥재
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제54권4호
    • /
    • pp.172-176
    • /
    • 2005
  • Power system restoration following a massive or complete blackout starts with energizing of primary restorative transmission lines. During this primary restoration, inexpected overvoltage may happen due to nonlinear interaction between the unloaded transformer and the transmission system. This is known as the harmonic resonance phenomenon that may cause burning out of transformer or other devices. By now the harmonic resonance is reported in the extra high voltage system. This paper reports the detection of the resonance in Korean power system. Basic analysis and simulation of the harmonic overvoltage is presented using EMTDC.

EMTDC를 이용한 전기철도 급전계통의 고조파 해석에 관한 연구 (A study on Harmonic Analysis of Electric Railway System Using EMTOG)

  • 이한민;한문섭;오광해;이장무;박현준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 B
    • /
    • pp.1276-1278
    • /
    • 2003
  • The magnified current harmonics usually brings about various problems. That is, the current harmonics makes interference in the adjacent lines of communications and the railway signalling system. Furthermore, in case it flows on the side of power system, not only overheating and vibration at the power capacitors but also wrong operation at the protective devices can occur. Therefore, the exact assessment of the harmonic current flow must be undertaken at design and planning stage for the electric traction systems. From these point of view, this study presents the harmonic analysis and the modelling of traction power feeding system focused on the amplification of harmonic current.

  • PDF

PSCAD/EMTDC를 이용한 시송전계통의 고조파 공진현상 분석 (Analysis of the Harmonic Resonance of Primary Restorative Transmission System Using PSCAD/EMTDC)

  • 이흥재;조병관;이경섭;박성민;배주천;황봉환;이낭호;송인준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.31-33
    • /
    • 2003
  • Power system restoration following a partial or complete blackout starts with energizing of primary transmission lines. Because system changed rapidly during early restoration process, transformer energization and load pickup is executed to maintain the power system stability. However unexpected problem such as harmonic overvoltage may be arisen during energizing transformer. The reason of harmonic overvoltage is known as transformer saturation and magnetizing in-rush current and so on, but it is difficult to estimate the condition of occurrence. This paper describes the analysis of the harmonic overvoltage while unloaded transformer is energized using PSCAD/EMTDC.

  • PDF

여러 개의 조화맥동을 갖는 유체를 운반하는 파이프의 진동 해석 (The Vibration Analysis of Pipes Conveying Fluid with Several Harmonic Pulsations)

  • 정석현;서영수;정의봉
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.1077-1082
    • /
    • 2004
  • It is well known that the pipe will be unstable if the fluid velocity is higher than critical velocity. But even if the velocity of the fluid below the critical velocity, resonance will be caused by pulsation of the fluid. So, many people has studied about the piping system vibration due to a fluid pulsation. But almost guess that fluid has only one hamonic pulsation. Actually, like this case is rare quite. So, in this paper, we consider the vibration analysis of a pipe conveying fluid with several harmonic pulsations and compare the result which considers one hamonic pulsation with the result which considers several harmonic pulsations. And we verify the result in time domain again.

  • PDF