• 제목/요약/키워드: Harmonic Generator

검색결과 150건 처리시간 0.031초

속도계가 부착된 구조물에서 조화성분의 공진이 미치는 영향 고찰 (Effect Investigation of Resonance by Harmonic Components on Structures with Velocity Seismoprobes in a Turbine Rotor System)

  • 양경현;조철환;배춘희;송오섭
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.98-102
    • /
    • 2005
  • Most bearing casings are designed to focus on strength and weight of themselves because rotor speed passes through the critical speed when operation begins in large plants such as power plants. And It is treated importantly the relation between rotating frequency of the rotor and the natural frequency of casings to prevent resonance. But there is some cases that it is overlooked for harmonic components above rotating frequency. So we present experimentally a case that harmonic forces may make a resonance on casing fixing probes to measure vibration in a turbine-generator system and the vibration is generated when one component of harmonic forces excites the mode that the natural frequency of a certain bearing casing is close to one of harmonics of basic rotating frequency (1x).

  • PDF

풍력발전용 3MW급 외부회전자형 영구자석 동기발전기 설계 (Design of 3MW Class Outer Rotor Type PMSG for Wind Turbine)

  • 김태훈
    • 신재생에너지
    • /
    • 제6권4호
    • /
    • pp.41-49
    • /
    • 2010
  • Over the last decade, wind turbine industry has rapidly increased around world. These days many parts of the wind generators are induction generator. But it has some problems such as gearbox failure, rotor excitation and maintenance. Thus many manufacturers are considered permanent magnet synchronous generator named PMSG and direct drive. PMSG uses NdFeB magnet has many the advantage compare with induction generator. In this study, 3MW class outer rotor type PMSG for wind turbine is proposed. The generator features 2.6m stator outer radius, 1200mm stator length, 81 pole pairs, 14 rated rpm, 42kN/$m^2$ shear force density and 94.2% efficiency. Design and analysis generator using FEM program. Then calculate and derivate no load voltage, losses, conductor temperature. To reduce total harmonic distortion and cogging torque, the stator is applied the stator skewing. And to evaluate the designed generator, compare with other generators by active mass per rating torque and torque density.

A Solid State Controller for Self-Excited Induction Generator for Voltage Regulation, Harmonic Compensation and Load Balancing

  • Singh Bhim;Murthy S. S.;Gupta Sushma
    • Journal of Power Electronics
    • /
    • 제5권2호
    • /
    • pp.109-119
    • /
    • 2005
  • This paper deals with the performance analysis of static compensator (STATCOM) based voltage regulator for self­excited induction generators (SEIGs) supplying balanced/unbalanced and linear/ non-linear loads. In practice, most of the loads are linear. But the presence of non-linear loads in some applications injects harmonics into the generating system. Because an SEIG is a weak isolated system, these harmonics have a great effect on its performance. Additionally, SEIG's offer poor voltage regulation and require an adjustable reactive power source to maintain a constant terminal voltage under a varying load. A three-phase insulated gate bipolar transistor (IGBT) based current controlled voltage source inverter (CC- VSI) known as STATCOM is used for harmonic elimination. It also provides the required reactive power an SEIG needs to maintain a constant terminal voltage under varying loads. A dynamic model of an SEIG-STATCOM system with the ability to simulate varying loads has been developed using a stationary d-q axes reference frame. This enables us to predict the behavior of the system under transient conditions. The simulated results show that by using a STATCOM based voltage regulator the SEIG terminal voltage can be maintained constant and free from harmonics under linear/non linear and balanced/unbalanced loads.

영구자석 형상 변형을 통한 동기발전기 고조파 저감 (Harmonic Reduction of Synchronous Generator by Permanent Magnet Shape Deformation)

  • 변범석;박의종;김용재
    • 한국전자통신학회논문지
    • /
    • 제17권6호
    • /
    • pp.1081-1088
    • /
    • 2022
  • 동기발전기의 고조파는 철손과 동손을 증가시켜 발열의 원인이 된다. 이를 감소시키기 위하여 전기자의 권선법을 분포권, 단절권을 이용하여 고조파를 감소시키는 방법이 있으나 본 논문에서는 영구자석의 형상을 기존에 연구되었던 방법이 아닌 새로운 형상 변형을 통해 고조파를 감소시키며 기전압의 파형을 개선하고자 한다. 형상 변형 방법으로 영구자석의 양단을 절단하고 설정값에 따라 영구자석의 면적을 증가, 감소시켜 공극의 길이를 조절한다. 이때 자속밀도의 분포를 다르게 하여 이에 따른 기전압과 왜형률을 비교하였다. 이를 통해 논문에 기술된 영구자석의 형상 변화 모델들을 비교하고 가장 효과적인 변형 방법을 나타냈다.

Acoustic Noise Reduction of Three-Phase SRM with Random Pulse Position PWM and Random Turn-on/off Angle Control

  • Khai, Nguyen Minh;Shin, Duck-Shick;Jung, Young-Gook;Lim, Young-Cheol
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.139-142
    • /
    • 2006
  • This paper describes a new method using random modulated strategies for switched reluctance machines. The proposed method is combined random turn-on, turn-off angle technique and random pulse width modulation technique. The purpose of this proposed method is to decrease harmonic spectrum, and thus reduce the emitted acoustical noise. A random generator is generated by linear congruential generator (LCG) using random pulse position (RPP) scheme. Simulation results show that the harmonic intensity of proposed method is better than that of conventional method.

  • PDF

상전류 고조파 분석을 이용한 직교류 부하에 따른 영구자석 동기 발전기의 회전자 손실 특성해석 및 비교 (Comparison and Analysis for Rotor losses of Permanent Magnet Synchronous Generator using Phase Current Harmonic Analysis according to DC and AC Loads)

  • 장석명;김현규;최장영;고경진;이성호;김일중
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.721-722
    • /
    • 2008
  • This paper deals with comparison and analysis for rotor losses of permanent magnet synchronous generator using phase current harmonic analysis according to dc and ac load. On the basis of analytical field analysis, the rotor losses are analysed. Particularly, rated speed and ac load and the rated speed and dc load conditions are considered. This paper compared rotor losses considered dc load with rotor losses considered ac load. Although our analytical modes is low speed, the rotor losses must be considered by results.

  • PDF

A Comparison of Control Algorithms for a Doubly Fed Induction Generator in Medium-voltage Wind Power System under Unbalanced Conditions

  • 고유란;박현철;주야충;서용석
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2010년도 하계학술대회 논문집
    • /
    • pp.194-195
    • /
    • 2010
  • This paper investigates control algorithms for a doubly fed induction generator (DFIG) with back-to-back converter in medium-voltage wind power system under unbalanced grid conditions. Operation of DFIG under unbalanced grid conditions causes several problems such as overcurrent, unbalanced currents, active power pulsation and torque pulsation. Three different control algorithms to compensate for the unbalanced conditions have been investigated with respect to four performance factors; fault ride-through capability, efficiency, harmonic distortions and torque pulsation. The control algorithm having zero amplitude of negative sequence current shows the most cost-effective performance concerning fault ride-through capability and efficiency. The control algorithm for nullifying the oscillating component of the instantaneous active power generates least harmonic distortions. Combination of these two control algorithms depending on the operating requirements presents most optimized performance factors under the generalized unbalanced operating conditions.

  • PDF

Minimization of Torque Ripple for a Doubly Fed Induction Generator in Medium Voltage Wind Power System under Unbalanced Grid Condition

  • Park, Yonggyun;Suh, Yongsug;Go, Yuran
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 전력전자학술대회 논문집
    • /
    • pp.273-274
    • /
    • 2012
  • This paper investigates control algorithms for a doubly fed induction generator(DFIG) with a back-to-back three-level neutral-point clamped voltage source converter in medium voltage wind power system under unbalanced grid conditions. Two different control algorithms to compensate for unbalanced conditions are proposed. Evaluation factors of control algorithm are fault ride-through(FRT) capability, efficiency, harmonic distortions and torque pulsation. Zero regulated negative sequence stator current control algorithm has the most effective performance concerning FRT capability and efficiency. Ripple-free control algorithm nullifies oscillation component of active power and reactive power. Ripple-free control algorithm shows the least harmonic distortions and torque pulsation. Combination of zero regulated negative sequence stator current and ripple-free control algorithm control algorithm depending on the operating requirements and depth of grid unbalance presents the most optimized performance factors under the generalized unbalanced operating conditions leading to high performance DFIG wind turbine system.

  • PDF

Optimal Harmonic Stepped Waveform Technique for Solar Fed Cascaded Multilevel Inverter

  • Alexander, S.Albert;Thathan, Manigandan
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권1호
    • /
    • pp.261-270
    • /
    • 2015
  • In this paper, the Optimal Harmonic Stepped Waveform (OHSW) method is proposed in order to eliminate the selective harmonic orders available at the output of cascaded multilevel inverter (CMLI) fed by solar photovoltaic (SPV). This technique is used to solve the harmonic elimination equations based on stepped waveform analysis in order to obtain the optimal switching angles which in turn reduce the Total Harmonic Distortion (THD). The OHSW method considers the output voltage waveform as four equal symmetries in each half cycle. In the proposed method, a solar fed fifteen level cascaded multilevel is considered where the magnitude of six numbers of harmonic orders is reduced. A programmable pulse generator is developed to carry the switching angles directly to the semiconductor switches obtained as a result of OHSW analysis. Simulations are carried out in MATLAB/Simulink in which a separate model is developed for solar photovoltaic which serves as the input for cascaded multilevel inverter. A 3kWp solar plant with multilevel inverter system is implemented in hardware to show the effectiveness of the proposed system. Based on the observation the OHSW method provides the reduced THD thereby improving power quality in renewable energy applications.

파력발전용 병진 질량-스프링식 파력 변환장치의 동적설계 (Dynamic Design of a Mass-Spring Type Translational Wave Energy Converter)

  • 최영휴;이창조;홍대선
    • 한국생산제조학회지
    • /
    • 제21권1호
    • /
    • pp.182-189
    • /
    • 2012
  • This study suggests a dynamic design process for deciding properly design parameters of a mass-spring type Wave Energy Converter (WEC) to achieve sufficient energy conversion from wave to power generator. The WEC mechanism, in this research, consists of a rigid sprung body, a platform, suspension springs and dampers. The rigid sprung body is supported on the platform via springs and dampers and vibrates translationally in the heave direction under wave excitation. At last the resulting heave motion of the sprung body is transmitted to rotating motion of the electric generator by rack and pinion, and transmission gears. For the purpose of vibration analysis, the WEC mechanism has been simply modelled as a mass-spring-damper system under harmonic base excitation. Its maximum displacement transmissibility and steady state response can be determined by using elementary vibration theory if the harmonic ocean wave data were provided. With the vibration analysis results, the suggested dynamic design process of WEC can determine all the design parameters of the WEC mechanism, such as sprung body mass, suspension spring constant, and damping coefficient that can give sufficient relative displacement transmissibility and the associated inertia moment to drive the electric generator and transmission gears.