• Title/Summary/Keyword: Harmonic Filter

Search Result 652, Processing Time 0.025 seconds

LINE SIDE HARMONIC ANALYSIS OF SINGLE-PHASE DIODE BRIDGE RECTIFIER WITH A DC FILTER CAPACITOR

  • Liu, Jinjun;Wang, Zhaoan
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.603-608
    • /
    • 1998
  • Single-phase diode bridge rectifiers with dc filter capacitor usually operate in discontinuous mode and generate large amounts of harmonic currents. This paper presents a precise harmonic analysis of the line side current in the case that both the filter inductor and the filter capacitor are not infinite. The analytical expressions of the line side performance parameters associated with harmonics are derived. The curves that show the relationship of these parameters associated with harmonics are derived. The curves that show the relationship of these parameters as the functions of circuit parameters are illustrated. By simulation the results are verified to be accurate and the conclusion clearly reveals the relations between the line side performance parameters and circuit parameters.

  • PDF

A Multiband Shunt Hybrid Active Filter with Sensorless Control

  • Kumar S, Surendra;Sensarma, Partha Sarathi
    • Journal of Power Electronics
    • /
    • v.8 no.4
    • /
    • pp.317-324
    • /
    • 2008
  • This paper proposes a Multiband Shunt Hybrid Active Filter (SHAF) with sensorless control. A plant is modeled in the discrete- time domain and a controller is designed using the Pole shifting law in the polynomial domain. This control approach is very useful for filtering the load harmonics with reduced sensor counts where a low cost solution like SHAF is required. Multiple Synchronous Reference Frames (MSRF) and low pass filters are used to measure the $5^{th}$ and $7^{th}$ harmonic components separately from the load and filter currents. Individual current controllers are designed for the $5^{th}$ and $7^{th}$ harmonic currents. Control is realized in the stationary, three-phase (abc) reference frame. Performance of the controller is validated through simulation, using realistic plant and controller models, as well as experimentally on a full-scale distribution system.

A Novel Hybrid Active Power Filter with a High-Voltage Rank

  • Li, Yan;Li, Gang
    • Journal of Power Electronics
    • /
    • v.13 no.4
    • /
    • pp.719-728
    • /
    • 2013
  • A novel hybrid active power filter (NHAPF) that can be adopted in high-voltage systems is proposed in this paper. The topological structure and filtering principle of the compensating system is provided and analyzed, respectively. Different controlling strategies are also presented to select the suitable strategy for the compensation system. Based on the selected strategy, the harmonic suppression function is used to analyze the influence of system parameters on the compensating system with MATLAB. Moreover, parameters in the injection branch are designed and analyzed. The performance of the proposed NHAPF in harmonic suppression and reactive power compensation is simulated with PSim. Thereafter, the overall control method is proposed. Simulation analysis and real experiments show that the proposed NHAPF exhibits good harmonic suppression and reactive power compensation. The proposed compensated system is based on the three-phase four-switch inverter, which is inexpensive, and the control method is verified for validity and effectiveness.

A Study on UPS with Active Power Filter Function (능동전력필터기능을 갖는 UPS에 관한 연구)

  • Park, In-Seok;Lee, Jeong-Joon;Sung, Nark-Kuy;Oh, Bong-Hwan;Kim, Sung-Nam;Han, Kyung-Hee
    • Proceedings of the KIEE Conference
    • /
    • 1998.07f
    • /
    • pp.2178-2180
    • /
    • 1998
  • Recently, for increasing consumed power and informational society, confidence of power supply is demanded. Beside, owing to most of these loads are nonlonear, utility line is polluted by these components, therefore, it is demanded compensation of harmonic current. In times past, special order of harmonic current is only compensated by passive filter, but active power filter can compensate whole harmonic current. Therefore, this paper propose uninterruptable power supply(UPS) with performance of active power filter.

  • PDF

Comparison of Harmonic Detecting Methods For Sing-Phase Multi Level Active Power Filters (단상 멀티레벨 능동전력필터를 위한 고조파 검지 기법 비교)

  • Kim, Yoon-Ho;Kim, Soo-Hong;Kim, Sung-Min;Seo, Kang-Moon
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.494-497
    • /
    • 2005
  • In this paper, harmonic detecting methods for the active power application are investigated. They are RDFT, Kalman Filter, Adaptive predictive filter, Instantaneous reactive power detecting method, Improved adaptive filter detecting method. The 5 harmonic detecting methods are simulated and their characteristics for the active filter application are compared using simulation results.

  • PDF

Optimal Allocation Method of Hybrid Active Power Filters in Active Distribution Networks Based on Differential Evolution Algorithm

  • Chen, Yougen;Chen, Weiwei;Yang, Renli;Li, Zhiyong
    • Journal of Power Electronics
    • /
    • v.19 no.5
    • /
    • pp.1289-1302
    • /
    • 2019
  • In this paper, an optimal allocation method of a hybrid active power filter in an active distribution network is designed based on the differential evolution algorithm to resolve the harmonic generation problem when a distributed generation system is connected to the grid. A distributed generation system model in the calculation of power flow is established. An improved back/forward sweep algorithm and a decoupling algorithm are proposed for fundamental power flow and harmonic power flow. On this basis, a multi-objective optimization allocation model of the location and capacity of a hybrid filter in an active distribution network is built, and an optimal allocation scheme of the hybrid active power filter based on the differential evolution algorithm is proposed. To verify the effect of the harmonic suppression of the designed scheme, simulation analysis in an IEEE-33 nodes model and an experimental analysis on a test platform of a microgrid are adopted.

Rotation-Invariant Fingerprint Identification System for Security Verification (안전 검증을 위한 회전 불변 지문인식 시스템)

  • Lee, S.H.;Ryu, D.H.;Park, M.S.;Ryu, C.S.
    • Journal of the Korean Society of Safety
    • /
    • v.14 no.2
    • /
    • pp.192-199
    • /
    • 1999
  • We propose a rotation invariant fingerprint identification system based on the circular harmonic filter(CHF) and binary phase extraction joint transform correlator(BPEJTC) for validation and security verification. It is shown that this system has the shift and rotation robust properties and can recognize the fingerprint in real-time. The complex circular harmonic filter, which is used to obtain the rotation invariance, is converted into the real-valued filter for real-time implementation. Experimental results show that this system has a good performance in the rotated fingerprints.

  • PDF

Harmonic Estimation of Power Signal Based on Time-varying Optimal Finite Impulse Response Filter (시변 최적 유한 임펄스 응답 필터 기반 전력 신호 고조파 검출)

  • Kwon, Bo-Kyu
    • The Journal of Korean Institute of Information Technology
    • /
    • v.16 no.11
    • /
    • pp.97-103
    • /
    • 2018
  • In this paper, the estimation method for the power signal harmonics is proposed by using the time-varying optimal finite impulse response (FIR) filter. To estimate the magnitude and phase-angle of the harmonic components, the time-varying optimal FIR filter is designed for the state space representation of the noisy power signal which the magnitude and phase is considered as a stochastic process. Since the time-varying optimal FIR filter used in the proposed method does not use any priori information of the initial condition and has FIR structure, the proposed method could overcome the demerits of Kalman filter based method such as poor estimation and divergence problem. Due to the FIR structure, the proposed method is more robust against to the model uncertainty than the Kalman filter. Moreover, the proposed method gives more general solution than the time-invariant optimal FIR filter based harmonic estimation method. To verify the performance and robustness of the proposed method, the proposed method is compared with time-varying Kalman filter based method through simulation.

A New Low Cost Hybrid Power Filter for Thyristor-Controlled Rectifier Load (싸이리스터 정류부하를 위한 새로운 저원가 복합형 전력필터)

  • 한성룡;김수근;석원엽;조정구;송의호;전희종
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.1
    • /
    • pp.24-29
    • /
    • 2004
  • A new low cost hybrid active filter for thyristor-controlled rectifier load is presented to overcome the high cost problem of the active or the other hybrid active filters. The proposed hybrid active filter which consists of tuned (5th and 7th harmonics) LC passive filters, power factor improvement(PFI) capacitor bank, and active filter compensates power factor as well as harmonic currents. Since most of harmonic currents are filtered by the passive filter and most of reactive power is compensated by the PFI capacitor bank, the power rating of active filter can be minimized, resulting in cost minimization of the proposed hybrid active filter. A 300kVA hybrid active filter system is implemented and tested using 1MVA thyristor rectifier load to verify the operation and performance.

A Hybrid Active Power Filter for Electric-Railway Systems Using Multi-Level Inverters (멀티레벨 인버터를 이용한 전기철도용 하이브리드 능동 전력필터)

  • 김윤호;김수홍;이강희
    • Journal of the Korean Society for Railway
    • /
    • v.7 no.4
    • /
    • pp.339-344
    • /
    • 2004
  • This paper proposes transformerless power conversion system consisting of a single-phase diode rectifier and a shunt hybrid filter for the electric-railway system. The hybrid filter consists of a single tuned LC filter per a phase and a low-rated NPC type multi-level inverter. Compared with conventional active filters. transformers are not used. Also, LC filter works as not only a harmonic filter tuned at the 3rd harmonic frequency but also a switching-ripple filter. The rating of the active filter can be decreased by using a NPC type multi-level inverter. The simulation results confirm the validity of the system.