• 제목/요약/키워드: Hardware complications

검색결과 27건 처리시간 0.022초

전방 경추 유합술에서의 PCB System의 임상적 경험 (Clinical Experience of Anterior Cervical Interbody Fusion with the PCB System)

  • 김성한;김호진;강재규;도종웅;이춘대
    • Journal of Korean Neurosurgical Society
    • /
    • 제30권10호
    • /
    • pp.1170-1176
    • /
    • 2001
  • Objective : The purpose of the study was to evaluate the clinical and radiological results after discectomy and Lubboc bone graft in the surgical management of the cervical diseases with a new titanium interbody implant and integrated screw fixation(PCB) by anterior approach. Methods : The authors retrospectively analyzed 28 cases of anterior cervical fusion with PCB system and Lubboc bone(xeno graft) from september 1998 to december 2000. Twenty-eight patients with cervical diseases underwent decompression cervical lesion and followed from 5 to 27 months with a mean follow-up of 14 months. There patients were evaluated with clinically and radiologically at immediate postoperative period and at 3, 6, 9, and 12 months. Result : The authors investigated the pre- and postoperative intervertebral disc space, clinical outcomes, radiography fusion rate, and Cobb angle in the fixed segments by anterior approach. The lordotic angles and height of disc space were increased after the operation. The clinical outcome of patients follow-up was good or excellent result based on Odom's criteria with improvement of clinical symptom in about 92.9% of the cervical diseases. Two patients showed loosening of the lower and upper cervical screw of PCB instruments, and two patients showed swallowing difficulty and wound infection Conclusion : The PCB system is a new implant for anterior cervical interbody fusion in the degenerative cervical disease and disc herniations. It provides immediate stability and segment distraction. The results of this study indicate that the PCB system is safe, easy handling of hardware, less complications, high fusion rate, and has provide the keeping the intervertebral disc space height and lordotic angles.

  • PDF

Bone Cement Augmentation of Short Segment Fixation for Unstable Burst Fracture in Severe Osteoporosis

  • Kim, Hyeun-Sung;Park, Sung-Keun;Joy, Hoon;Ryu, Jae-Kwang;Kim, Seok-Won;Ju, Chang-Il
    • Journal of Korean Neurosurgical Society
    • /
    • 제44권1호
    • /
    • pp.8-14
    • /
    • 2008
  • Objective : The purpose of this study was to determine the efficacy of short segment fixation following postural reduction for the re-expansion and stabilization of unstable burst fractures in patients with osteoporosis. Methods : Twenty patients underwent short segment fixation following postural reduction using a soft roll at the involved vertebra in cases of severely collapsed vertebrae of more than half their original height. All patients had unstable burst fracture with canal compromise, but their motor power was intact. The surgical procedure included postural reduction for 2 days and bone cement-augmented pedicle screw fixations at one level above, one level below and the fractured level itself. Imaging and clinical findings, including the level of the vertebra involved, vertebral height restoration, injected cement volume, local kyphosis, clinical outcome and complications were analyzed. Results : The mean follow-up period was 15 months. The mean pain score (visual analogue scale) prior to surgery was 8.1, which decreased to 2.8 at 7 days after surgery. The kyphotic angle improved significantly from $21.6{\pm}5.8^{\circ}$ before surgery to $5.2{\pm}3.7^{\circ}$ after surgery. The fraction of the height of the vertebra increased from 35% and 40% to 70% in the anterior and middle portion. There were no signs of hardware pull-out, cement leakage into the spinal canal or aggravation of kyphotic deformities. Conclusion : In the management of unstable burst fracture in patients with severe osteoporosis, short segment pedicle screw fixation with bone cement augmentation following postural reduction can be used to reduce the total levels of pedicle screw fixation and to correct kyphotic deformities.

Anterior Cervical Instrumentation Using Intradiscal Cage with Integrated Plate

  • Ahn, Kyoung-Rok;Ryu, Kyeong-Sik;Chang, In-Bok;Cho, Byung-Moon;Park, Se-Hyuck;Oh, Sae-Moon
    • Journal of Korean Neurosurgical Society
    • /
    • 제39권4호
    • /
    • pp.260-264
    • /
    • 2006
  • Objective : The retrospective study is undertaken to report clinical results of anterior cervical interbody fusion with an intradiscal cage with an integrated plate [PCB cervical plating system]. Methods : 38 patients underwent anterior cervical interbody fusion with PCB cervical plating system and followed $6{\sim}24\;months$. The authors investigated overall surgical results; clinical outcome, fusion rate, change of interspace height & lordotic angle, and complications. Results : No complication was observed during the operation. Clinical improvement was identified in 34 cases [89.5%]. Bone fusion observed in 44 out of 49 sites [90.7%]. After operation, the interspace height increased from $5.4{\pm}1.3mm$ to $7.8{\pm}1.5mm$ and maintained $7.4{\pm}1.1mm$ and, interspace angle went up from $4.2{\pm}0.7^{\circ}$ to $4.8{\pm}1.1^{\circ}$ and maintained $4.6{\pm}$0.9^{\circ}. The loosening of screw was observed in 6 cases, one of which had reoperation because of the expulsion of the device accompanied. Conclusion : PCB cervical plating system could restore interbody height and lordosis in anterior cervical interbody fusion. But, if the insertion of the spacer is not precise, the frequencies of hardware failure are relatively high. It is considered necessary for the operator to be careful in the procedure.

Cement Augmentation of Dynamic Hip Screw to Prevent Screw Cut Out in Osteoporotic Patients with Intertrochanteric Fractures: A Case Series

  • Rai, Avinash Kumar;Goel, Rajesh;Bhatia, Chirag;Singh, Sumer;Thalanki, Srikiran;Gondane, Ashwin
    • Hip & pelvis
    • /
    • 제30권4호
    • /
    • pp.269-275
    • /
    • 2018
  • Purpose: The purpose of this study is to describe a method of inserting cement in the femoral head before fixation with dynamic hip screw to prevent screw cut out due to osteoporosis and to evaluate its clinical outcome in these patients. Materials and Methods: In this prospective study, 30 patients aged 60 years and older with intertrochanteric fracture were included. Bone mineral density was measured. After reaming of the femoral head and neck with a triple reamer and polymethyl methacrylate, bone cement was introduced into the femoral head using a customized nozzle and a barrel fitted on a cement gun. A Richard screw was inserted and the plate was fixed over the femoral shaft. Patients were mobilized and clinical outcomes were rated using the Salvati and Wilson's scoring system. Results: More patients included in this study were between 66 and 70 years old than any other age group. The most common fracture according to the Orthopaedic Trauma Association classification was type 31A2.2 (46.7%). The T-score was found to be $-2.506{\pm}0.22$ (mean${\pm}$standard deviation); all patients were within the range of -2.0 to -2.8. The duration of radiological union was $13.67{\pm}1.77$ weeks. Salvati and Wilson's scoring at 12 months of follow up was $30.96{\pm}4.97$. The majority of patients were able to perform their normal routine activities; none experienced implant failure or screw cut out. Conclusion: Bone cement augmentation may effectively prevent osteoporosis-related hardware complications like screw cut out in elderly patients experiencing intertrochanteric fractures.

삽관 나사못(Cannulated screw)을 사용한 경골 과간 융기부 견열 골절의 관절경적 치료 기법 (Arthroscopic Cannulated Screw Fixation Technique for Avulsion Fracture of the Intercondylar Eminence of the Tibia)

  • 이기병;장호근;이석범;문영완;강기훈;이욱형
    • 대한관절경학회지
    • /
    • 제3권2호
    • /
    • pp.127-131
    • /
    • 1999
  • 경골 과간 융기부의 견열 굴절은 비교적 드물지 않게 관찰되는 손상으로, 전위된 견열 골절편은 해부학적 정복과 견고한 고정을 필요로 한다. 그러나 관절경적 수술 방법을 포함한 대부분의 잘 알려진 수술 방법들은 비교적 복잡한 수술 기법과 정교한 수술 술기를 필요로 하며, 이에 따른 수술 시간의 지연과 수술 합병증으로 창상 감염, 조기 성장판 폐쇄 및 조기 관절 운동을 제한하는 고정력의 소실 등이 발생할 수 있다. 이에 저자들은 전외측 및 중앙부, 내측 mid-patella 입구를 사용한 관절경적 기법을 이용하여, 골편의 정복에 삽관 나사못을 사용함으로써, 비교적 짧은 수술 시간 안에 만족스런 정복과 고정을 얻을 수 있었으며, 술 후 조기에 능동적 관절 운동을 허용할 수 있었다. 또한 분쇄 골절의 경우 와셔를 사용함으로써 만족스런 고정을 얻을 수 있었다. 저자들의 방법은 수술 기법의 용이함과 금속 제거 시의 안전성, IV형 분쇄 골절에도 적용할 수 있는 점, 추가적인 피부 절개가 필요없다는 점, 성장기 소아에서 성장판의 손상 가능성을 줄일 수 있는 등의 장점이 있다고 사료된다.

  • PDF

전방 정복술 및 경피적 후방 압박나사 내고정술을 이용한 전위성 거골 경부 골절의 치료 결과 (Clinical Outcomes of Anterior Open Reduction and Posterior Percutaneous Screw Fixation for Displaced Talar neck Fractures)

  • 박지강;김용민;최의성;손현철;조병기;차정권
    • 대한족부족관절학회지
    • /
    • 제17권2호
    • /
    • pp.106-114
    • /
    • 2013
  • Purpose: Posteroanterior screw fixation is biomechanically stronger than anteroposterior screw fixation. However, there are few literature about the correlation between clinical results and more strength by posteroanterior fixation. This study was performed to evaluate the clinical outcomes of the accelerated rehabilitation following anterior open reduction and posterior percutaneous screw fixation for displaced talar neck fractures. Materials and Methods: Eighteen cases were followed up for more than 1 year after posteroanterior fixation using headless compression screw for talar neck fractures. The clinical evaluation was performed according to American Orthopaedic Foot and Ankle Society (AOFAS) score and Hawkins criteria. As radiographic evaluation, the degree of fracture displacement, period to union, and occurrence rate of complications such as avascular necrosis through MRI were measured. Results: The AOFAS score was average 90.4 points at the last follow-up. There were 7 excellent, 9 good, and 2 fair results according to the Hawkins criteria. Therefore, 16 cases(88.8%) achieved satisfactory results. The degree of fracture displacement had improved significantly from preoperative average 5.6 mm to 1.2 mm immediate postoperatively, and maintained to 1.1mm at the last follow-up. All cases achieved bone union, and the period to union was average 12.4 weeks. There were 3 cases of avascular necrosis of talar body and 2 cases of post-traumatic arthritis. Conclusion: Anterior open reduction and posterior percutaneous headless screw fixation seems to be an effective surgical method for displaced talar neck fractures, because of the possibility of accurate restoration of articular surface, fixation strength enough to early rehabilitation, and needlessness of hardware removal.

AO C-형 원위 대퇴골 골절의 치료로 삽입된 관외측 금속판의 절경 보조하 최소 침습적 제거의 결과 (Results of Arthroscopic-assisted Minimally Invasive Removal of a Lateral Periarticular Plate used for the Treatment of AO Type-C Distal Femoral Fractures)

  • 김영모;이준규;양재훈;김보건;이원구
    • 대한관절경학회지
    • /
    • 제13권1호
    • /
    • pp.46-52
    • /
    • 2009
  • 목적: AO C-형 원위 대퇴골 골절의 치료로서 대퇴골 외측에 금속판을 삽입한 후, 관절경 보조하 최소 침습적 금속판 제거를 시행하였던 환자들을 대상으로 술식의 유용성을 조사하였다. 대상 및 방법: 2002년 10월부터 2005년 11월까지 AO C-형 원위 대퇴골 골절로 관혈적 정복 및 대퇴골 외측면에 금속판 내고정술을 시행하였던 환자들 중 대퇴골 외과 부위의 불편감으로 인해 관절경 보조하 최소 침습적 금속판 제거를 시행하였던 17예와 관절경 없이 고식적인 방법으로 금속판 제거슬 시행한 15예, 총 32예를 대상으로 하였다. 평균 연령은 42.6세(20~66세), 최초 골절 상태는 AO/ASIF 분류상 C1 16예, C2 11예, C3 5예였다. 술 중 확인된 관절내 병변, 술 후 합병증 및 술 후 일상 생활로의 복귀 시간, 수술에 대한 만족도, 술 전 및 술 후 6개월 추시상의 슬관절 통증을 조사하였다. 결과: 전 예에서 금속판의 최고 원위부는 슬관절 내에 위치하였고, 23예에서 이와 접촉하는 외측 관절낭의 손상이 확인되었다. 관절경 보조하 금속판 제거술을 시행한 군에서 금속판 제거술 후 지속적 창상 배액으로 세척술 및 창상 재 봉합술을 시행한 경우가 1예 있었다. 술 후 일상 생활로의 복귀는 관절경 보조하 금속판 제거술을 시행한 군에서 평균 7일이었고, 고식적 금속판 제거술을 시행한 군에서 평균 7.6일 이었다. 관절경 보조하 금속판 제거술을 시행한 군은 14예(82.4%)에서 '보통' 이상의 수술 만족도를 보였으며, VAS 통증 지수는 수술 전 4.9에서 수술 후 6개월에 1.9로 감소하였다. 고식적 금속판 제거술을 시행한 군은 13예(86.7%)에서 보통' 이상의 수술 만족도를 보였으며, VAS 통증 지수는 수술전 5.2에서 수술 후 6개월에 2.5로 감소하였다. 결론: 본 술식은 원위 대퇴골에 삽입된 금속판 제거와 함께 슬관절 내의 다양한 병변의 확인 및 치료가 가능한 장점이 있었다. C-형 원위 대퇴골 골절의 치료를 위해 삽입된 금속판에 의한 슬관절 외측 관절낭의 손상이 매우 빈번히 확인되었고, 금속판을 제거함으로서 슬관절 통증이 감소하는 것을 확인하였음으로, C-형 원위 대퇴골 골절과 같이 금속판의 최고 원위부가 관절내에 위치하는 경우에는 골절의 유합이 이루어지면 금속판을 제거되어야 할 것으로 사료된다.

  • PDF