• Title/Summary/Keyword: Hard x-ray

Search Result 209, Processing Time 0.025 seconds

MID- AND FAR-INFRARED PROPERTIES OF LOCAL ACTIVE GALACTIC NUCLEI

  • Ichikawa, Kohei;Ueda, Yoshihiro;Terashima, Yuichi;Oyabu, Shinki;Gandhi, Poshak;Matsuta, Keiko;Nakagawa, Takao
    • Publications of The Korean Astronomical Society
    • /
    • v.27 no.4
    • /
    • pp.275-279
    • /
    • 2012
  • We investigate the mid-infrared (MIR) to far-infrared (FIR) properties of a nearly complete sample of local active galactic nuclei (AGNs) detected in the Swift/Burst Alert telescope (BAT) all-sky hard X-ray (14-195 keV) survey, based on the cross correlation with the infrared survey catalogs of AKARI, IRAS and WISE. Out of 135 non-blazar AGNs in the Swift/BAT 9-month catalog, we obtain the MIR photometric data for 128 sources in either the 9, 12, 18, 22, and $25{\mu}m$ band. We find a good correlation between their hard X-ray and MIR luminosities ranging three orders of magnitude (42 < log ${\lambda}L_{\lambda}$(9, $18{\mu}m$) < 45), which is tighter than that with the FIR luminosities at $90{\mu}m$. Both X-ray unabsorbed and absorbed AGNs follow the same correlation, implying isotropic infrared emission, as expected in clumpy dust tori models rather than homogeneous ones.

Structure of Ni and NiO Nanoparticles Observed by X-ray Coherent Diffraction Imaging

  • Kim, Chan;Kim, Yoon-Hee;Hamh, Sun-Young;Son, Jun-Gon;Khakurel, Krishna Prasad;Iqbal, Mazhar;Noh, Do-Young
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.542-543
    • /
    • 2012
  • Coherent diffraction imaging (CDI) method using hard x-ray at 5.46 keV was applied to study assembly of Ni and Ni oxide nano structures formed on a Si3N4 membrane. Density distribution of Ni nano-particles was obtained quantitatively with about 15 nm lateral resolution by reconstructing images from the speckle diffraction pattern. In addition, reconstructed images of nickel oxide particles indicated that Ni atoms diffuse out during the oxidation process leaving pores inside the nickel oxide crust. Furthermore, we recognize that really weak phase object, less than 5 nm thickness of Ni residues, can be reconstructed due to the reference particles. We achieved quantitative information of nanometer sized materials and demonstrate the effect of reference particles by using hard x-ray coherent diffractive imaging method.

  • PDF

A Study of the 3D Anatomical Structure Analysis of Leech Using Hard X-ray Micro Tomography by Synchrotron Radiation (방사광 경 엑스선 마이크로 단층촬영을 이용한 거머리의 해부학적 3차원 구조분석)

  • Lee, Ji Won;Lee, On Seok
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.12
    • /
    • pp.70-77
    • /
    • 2016
  • In this study, we aim to obtain the fundamental data needed for the objective analysis and bio-mimetics of leeches, using x-ray imaging with radiation that allows 3D analysis of the detailed anatomic structures of leeches. It was confirmed that through using radiation, detailed images of leeches can be obtained, allowing 3D analysis of leeches' anatomical structures. Also, since the data obtained through the radiation allows you to observe the micro-structure, it can serve as a good resource for component analysis, as well as physiological and functional research. More, it is hoped to contribute to further research in the areas of bio-mimetics using leeches.

Vacuum system for PAL-XFEL (4세대방사광가속기 진공시스템)

  • Na, Donghyun
    • Vacuum Magazine
    • /
    • v.4 no.1
    • /
    • pp.12-15
    • /
    • 2017
  • The Pohang Accelerator Laboratory X-ray Free Electron Laser (PAL-XFEL) is a 0.1 nm hard X-ray FEL which aims at providing photon flux higher than $1{\times}10^{12}$ photons/pulse using a 10-GeV electron linac. The vacuum system of the machine consists of an injector section including an S-band photocathode RF gun, 10-GeV electron linac section based on S-band normal conducting accelerating structures and a 150-m long out-vacuum undulator system. We introduce the present status of PAL-XFEL vacuum systems.

Parsec-scale radio properties of the X-ray selected AGN sample

  • Baek, Junhyun;Chung, Aeree;Schawinski, Kevin;Oh, Kyuseok;Wong, Ivy;Ricci, Claudio;Koss, Michael;Mushotzky, Richard;Smith, Krista
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.42 no.2
    • /
    • pp.73.4-74
    • /
    • 2017
  • We report preliminary results from our radio study of X-ray selected complete AGN sample in the Local Universe (z < 0.05), using the KVN/KaVA. The main goal is to probe the parsec-scale radio properties of the X-ray selected AGNs, which has not been done systematically before. The BASS (Burst Alert Telescope AGN spectroscopic survey) sample from the Swift-BAT hard X-ray all-sky survey is the least biased AGN sample against dense gas/torus obscurations compared to optically selected AGNs, providing ideal targets to study the general properties of local AGNs in radio wavelengths. Combining our radio data with BASS X-ray/optical measurements, we will probe the relations of radio powers with the fundamental quantities of black holes such as bolometric luminosity, black hole mass, and Eddington ratio. Using these relations, we will discuss our current understandings of how accretions and jets of local AGNs are linked together, and what they imply for the nature of our AGN sample.

  • PDF

A STUDY OF THE DYNAMICAL CROSS CORRELATION FUNCTION IN A BLACK HOLE SOURCE XTE J1550-564

  • SRIRAM, K.;CHOI, C.S.;RAO, A.R.
    • Publications of The Korean Astronomical Society
    • /
    • v.30 no.2
    • /
    • pp.599-601
    • /
    • 2015
  • The short time scale X-ray variability associated with the accretion disk around compact objects is complex and is vaguely understood. The study of the cross correlation function gives an insight into the energy dependent behavior of the variations and hence connected processes. Using high resolution RXTE data, we investigate the dynamical cross correlation function of an observation of a black hole source XTE J1550-564 in the steep power law state. The cross correlation between soft and hard X- ray energy bands revealed both correlated and anti-correlated delays (${\leq}{\pm}15s$) on a correlation time scale of 50 s. It was noticed that the observed delays were similar to the delays between X-ray and optical/IR bands in other black hole and neutron star sources. We discuss the possible mechanisms/processes to explain the observed delays in the dynamical CCF.

BAT AGN Spectroscopic Survey-III. An observed link between AGN Eddington ratio and narrow emission line ratios

  • Oh, Kyuseok;Schawinski, Kevin;Koss, Michael;Trakhtenbrot, Benny;Lamperti, Isabella;Ricci, Claudio;Mushotzky, Richard;Veilleux, Sylvain;Berney, Simon;Crenshaw, Daniel;Gehrels, Neil;Harrison, Fiona;Masetti, Nicola;Soto, Kurt;Stern, Daniel;Treister, Ezequiel;Ueda, Yoshihiro
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.41 no.2
    • /
    • pp.34.1-34.1
    • /
    • 2016
  • The ultra hard X-ray band (14-195 keV) provides an important and unbiased way to understand black hole growth and relationship to the host galaxy. The Burst Alert Telescope (BAT) instrument on the Swift satellite has surveyed sky to unprecedented sensitivity, improving the number of known hard X-ray sources by more than a factor of 20 to 836 nearby AGN. The BAT AGN Spectroscopic Survey (BASS) is a study for the first large (N>600) and complete sample of ultra hard X-ray selected AGN with optical spectroscopy. In this talk, I present the observed relationship between black hole mass, bolometric luminosity, and Eddington ratio with optical emission line ratios. We show that [NII]/Ha ratio exhibits a significant correlation with Eddington ratio. We propose that the [NII]/Ha ratio is a useful indicator of Eddington ratio with 0.6 dex of scatter, and that it can be used to measure Eddington ratio and thus black hole mass from the measured bolometric luminosity, even for high redshift obscured AGN.

  • PDF

Evaluation of Effectiveness of New Design Lead Apron during Pregnant X-ray Chest P-A (임산부 흉부 촬영중 사용할 새로 디자인된 납치마의 효율성 평가)

  • Kim, Hyeonggyun;Kwon, Soonmu;Jung, Hongmoon
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.6
    • /
    • pp.441-445
    • /
    • 2012
  • X-ray Chest P-A is very important and basic diagnosis examination for pregnant women. For a pregnancy period pregnant women should be treated very carefully not to be exposed to any radiation which might cause harmful damage to women and babies as well. Lead apron is one of the effective methods to protect pregnant women from the X-ray radiation. However, it is difficult to obtain the accurate position of pregnant women during X-ray Chest P-A since conventional lead apron method forces pregnant women to hold the apron by themselves only to make pregnant women very uncomfortable and hard to maintain accurate position during radiation. As a consequence, it is common to get low quality images of X-ray Chest P-A due to the overlap of apex of lung and scapular. In order to fix this problem, we made new design lead apron that allowed pregnant women to be more comfortable to maintain accurate position during X-ray Chest P-A position. Finally, with this new design lead apron, it was possible to get the best optimized images of X-ray Chest P-A of pregnant women by minimizing overlapping apex of lung and scapular.

Characterization of vanadium carbide coating deposited by borax salt bath process

  • Aghaie-Khafri, M.;Daemi, N.
    • Advances in materials Research
    • /
    • v.1 no.3
    • /
    • pp.233-243
    • /
    • 2012
  • Thermal reactive diffusion coating of vanadium carbide on DIN 2714 steel substrate was performed in a molten borax bath at $950-1050^{\circ}C$. The coating formed on the surface of the substrate had uniform thickness ($1-12{\mu}m$) all over the surface and the coating layer was hard (2430-2700 HV), dense, smooth and compact. The influence of the kinetics parameters, temperature and time, has been investigated. Vanadium carbide coating was characterized by scanning electron microscopy (SEM), energy dispersive X-ray spectrometry (EDX) and X-ray diffraction analysis (XRD). The corrosion resistance of the coating was evaluated by potentiodynamic polarization in 3.5% NaCl solution. The results obtained showed that decrease of coating microhardness following increasing time and temperature is owing to the coarsening of carbides and coating grain size.

Evaluation of Pore Size Distribution of Berea Sandstone using X-ray Computed Tomography (X-ray CT를 이용한 베레아 사암의 공극크기분포 산정)

  • Kim, Kwang Yeom;Kim, Kyeongmin
    • The Journal of Engineering Geology
    • /
    • v.24 no.3
    • /
    • pp.353-362
    • /
    • 2014
  • Pore structures in porous rock play an important role in hydraulic & mechanical behaviour of rock. Porosity, size distribution and orientation of pores represent the characteristics of pore structures of porous rock. While effective porosity can be measured easily by conventional experiment, pore size distribution is hard to be quantified due to the lack of corresponding experiment. We assessed pore size distribution of Berea sandstone using X-ray CT image based analysis combined with associated images processing, i.e., image filtering, binarization and skeletonization subsequently followed by the assessment of local thickness and star chord length. The aim of this study is to propose a new and effective way to evaluate pore structures of porous rock using X-ray CT based analysis for pore size distribution.