• Title/Summary/Keyword: Hard

Search Result 10,265, Processing Time 0.04 seconds

The Role of Evaluative Language in News Translation : Focusing on Soft and Hard News

  • Ban, Hyun;Noh, Bokyung
    • International Journal of Advanced Culture Technology
    • /
    • v.6 no.2
    • /
    • pp.65-71
    • /
    • 2018
  • In the digital era, news consumption is not confined in geological boundaries. Technological advances bring the instant dissemination of news into life and allow news audience to consume events that occur far away almost in real time. The transmission has blurred the boundary between traditional media and new media, and the one between physical and virtual world. That is, what if a journalist applies news framing to the news translation process? This paper aims to investigate the gap between the ST and the TT created when the source news texts undergo a translation process. To achieve this aim, the appraisal theory developed by White (2003) is employed to identify a difference between the ST and the TT. Furthermore, we have attempted to identify differences between soft news stories and hard news stories while the STs from both news stories are translated into the TTs. Two time-sensitive events, Hugh Grant's marriage and a U.S. and North Korea summit, were selected. The former (a soft news story) is extracted from the Telegraph and the latter (a hard news story) is from the Washington post. As a result, it was found that such strategies as attitude, engagement, and judgment were used when the source news texts from the hard news story are translated into the target news texts. Under the appraisal theory, the strategies involve evaluative language which refers to positive or negative language that judges the worth of entities. In general, it is said that a journalist frames the SS (especially from the hard news story) to convey his ideology to news consumers. Hypothetically, we assume that a similar framing process takes place in deriving the TT from the SS of the hard news story. Thus, we could conclude that the TT from the hard news story differs from the TT from the soft news story and that the difference can be explained within the framework of White's appraisal theory.

Effects of Polyol Types and Hard Segment Contents on the Crystallization of Thermoplastic Polyurethanes (열가소성 폴리우레탄의 결정화에 미치는 폴리올 종류 및 경질부 함량의 영향)

  • Kim Sung Geun;Li Ming Ji;Ramesan M. T.;Lee Dae Soo
    • Polymer(Korea)
    • /
    • v.29 no.2
    • /
    • pp.140-145
    • /
    • 2005
  • Effects of the polyol type and the hard segment content of thermoplastic polyurethane (TPU) on the crystallization of hard segments in TPUs were studied employing differential scanning calorimetry. Diols used for the preparation of TPUs were poly(tetramethylene ether glycol) (PTMEG), poly(propylene glycol) (PPG), polycaprolactone (PCL), poly(butylene adipate) (PBA) the molecular weights of which were 2000 and the hard segments contents of TPUs were $35\~44\;wt\%$. We found that crystallization of hard segments in TPUs were observed at higher temperatures and became faster with increasing hard segment contents of TPUs. The crystallization rate of TPU was also affected by the types of polyols used for the preparation of TPUs. It is postulated that lower miscibility of soft segments and hard segments results in higher crystallization rate and increase of cooling crystallization temperatures due to better hydrogen bending between hard segments in melts.

Correction of Lower Eyelid Retraction with Autogenous Hard Palate Mucosa: 2 Case Report (자가 경구개점막 이식을 이용한 하안검 퇴축의 교정: 2례 보고)

  • Kim, Jino;Seul, Chul Hwan;Roh, Tae Suk;Yoo, Woon Min
    • Archives of Plastic Surgery
    • /
    • v.33 no.4
    • /
    • pp.499-502
    • /
    • 2006
  • Purpose: Grave's disease is an autoimmune disease with chronic and systemic features. It affects the orbital fat and muscle bringing about defect in extrinsic eye motility, diplopia, optic nerve defect and lid retraction. In patients with lagopthalmos and resulting facial deformity, treatment can be done by rectus muscle recession or filling with various material. Autogenous auricular cartilage graft is often used and synthetic material such as synthetic acellular dermis, polyethylene meshs are also used for filling of the depressed area. Nevertheless, autogenous auricular cartilage grafts are difficult to utilize and synthetic materials sometimes result in protrusion or infection. Therefore, hard palate mucosa was considered as an alternative. We report two cases of patients with lower eyelid retraction corrected with autogenous hard palate mucosa. Methods: We performed this operation in two patients of Graves' ophthalmopathy. The capsulopalpebral fascia was incised and elevated through an incision on the conjunctiva. Then, the harvested hard palate mucosa was sutured to the inferior border of the tarsus and covered with the conjunctiva. Results: The lower eyelid retraction was corrected successfully. No hypertrophy or deformation of the transplanted hard palate mucosa was noted 6 months after the surgery. Conclusions: From the results above, we may conclude that the hard palate mucosa serves as an ideal spacer for the curvature and the inner lining in lower lid retraction. Hard palate mucosa is as sturdy as the autogenous cartilage but is much easier to utilize. It can be also used for lid retraction after lower lid aesthetic surgeries or traumas.

Studies on the Extractability and Characteristics of Actomyosin of Duck Muscle by Difference Scalding Method (침탕방법을 달리한 오리근육의 Actomyosin의 추출성과 특성에 관한 연구)

  • 정인철;이형걸;문윤희
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.21 no.4
    • /
    • pp.348-352
    • /
    • 1992
  • Investigation on the characteristics of actomyosin was prepared from leg and breast muscle of duck treated by hard scalding and subscalding method and their extractability , ATPase activity , solubility and SDS polyacrylamide gel electrophoresis were compared. The extractability of actomyosin in leg and breast muscle of duck by hard scalding was 7.84 and 39.84mg/g, whereas 4.79 and 28.04mg/g by subscalding respectively. Ca-ATPase activity of breast muscle wash higher than that of leg muscle. In case of leg muscle, hard scalding was higher tan subscalding. Breast muscle showed that subscalding was higher than hard scalding in less than ionic strength 0.08, and was lower than hard scalding in over ionic strength 0.08.Mg-ATPase was great in ionic strength and subcalding was relatively higher than hard scalding. Without regard to be treated method and part, the start point and end point of solubility were like. Hard scalded muscle and breast muscle showed that proteins in thin filament produced many extraction.

  • PDF

The Effect of Hard Insole on Metatarsophalangeal Joint in Patients With Hallux Valgus (무지 외반증 환자의 hard insole 착용에 의한 중족지절관절 각도의 변화)

  • Lim, Sung-Tae;Kim, Tack-Hoon;Choi, Houng-Sik;Roh, Jung-Suk;Kim, Jang-Hwan
    • Physical Therapy Korea
    • /
    • v.8 no.2
    • /
    • pp.17-27
    • /
    • 2001
  • The purpose of this study was to investigate the effect of donning of a hard insole in patients with hallux valgus. Fourteen subjects were selected from patient with foot pain at Lee Chang-Heon Foot Clinic from August 4, 2000 to September 15, 2000. The hallux valgus angle and the first-second intermetatarsal angle were radiographically measured before and after donning the hard insole. Based on these two kinds of angles, a mild hallux valgus deformity group was characterized by the hallux valgus angle of less than 20 degrees, and a moderate hallux valgus deformity group was characterized by the hallux valgus angle of 20 to 40 degrees. After three weeks with the hard insole donned, the foot angles of the patients with hallux valgus were measured again. The data were analyzed by Wilcoxon signed ranks test, and the following results were obtained: 1) After the trial, both mild hallux valgus deformity group and moderate hallux valgus deformity group demonstrated that the hallux valgus angles were significantly decreased. 2) After the trial, mild hallux valgus deformity group demonstrated that the first-second intermetatarsal angle was significantly decreased. 3) After the trial, moderate hallux valgus deformity group demonstrated that the first-second intermetatarsal angle was not significantly decreased. The above findings revealed that according to donning hard insole, the hallux valgus angles of mild and moderate hallux valgus deformity groups and the first-second intermetatarsal angle of mild hallux valgus deformity group were significantly decreased. The results of this study have some limitation for generalization due to the limited number of subjects. Further studies are needed to evaluate the effect of hard insole on hallux valgus with more precise laboratory equipments and measurements in patients with hallux valgus.

  • PDF

The Review for Various Mold Fabrication toward Economical Imprint Lithography (미세패턴 전사기법을 위한 다양한 몰드 제작법 소개)

  • Kim, Joo-Hee;Kim, Youn-Sang
    • Journal of the Korean Vacuum Society
    • /
    • v.19 no.2
    • /
    • pp.96-104
    • /
    • 2010
  • We suggest here a cost-effective replica fabrication method for transparent and hard molds for imprinting lithography such as NIL and S-FIL. The process starts with the use of a replica hard mold from a master, using a polymer copy as a carrier. The polymer copy as a carrier was treated by soluble process for forming anti-adhesion layer. Duplicated hard molds can eliminate direct contact between a hard master and a patterned polymer on a substrate and the generated contamination of a master during the imprinting process. The replica hard mold exhibits the glass-like properties introduced here, such as transparency and hardness, make it appropriate for nanoimprint lithography and step-and-flash imprint lithography.

Thermal Properties of Copolyetherester/silica Nanocomposites

  • Baik, Doo-Hyun;Kim, Hae-Young;Kwon, Sun-Jin;Kwon, Myung-Hyun;Lee, Han-Sup;Youk, Ji-Ho;Seo, Seung-Won
    • Fibers and Polymers
    • /
    • v.7 no.4
    • /
    • pp.367-371
    • /
    • 2006
  • Thermal properties of copolyetherester/silica nanocomposites were examined by using DSC and TGA. The segmented block copolyetheresters with various hard segment structures and hard segment contents (HSC) were synthesized and their silica nanocomposite films were prepared by solution casting method. The nano-sized fumed silica particles were found to act as a nucleating agent of the copolyetheresters. The nanocomposites always showed reduced degree of supercooling or faster crystallization than the corresponding copolyetheresters. The nanocomposites also showed increased hard segment crystallinity except HSC 35 sample which had short hard segment length. In case of 2GT [poly(ethylene terephthalate)] copolyetheresters, which were not developed commercially because of their low crystallization rate, the hard segment crystallinity increased considerably. The copolyetherester/silica nanocomposites showed better thermal stability than copolyetheresters.

Partial Matched Filter for Low Power and Fast Code Acquisition of DSSS-CPFSK Signals

  • Park, Hyung-Chul
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.4 no.3
    • /
    • pp.204-209
    • /
    • 2004
  • A partial matched filter (PMF) for semi-coherent correlation code acquisition of the DSSS-CPFSK signal is proposed. It is a calculation-reduced structure of the hard-limited signal based FIR filter, yet its code acquisition time is equal to that of the hard-limited signal based FIR filter. The PMF eliminates duplicate calculations by utilizing the characteristic that the hard-limited DSSS-CPFSK signal has same value in several consecutive samples. For example, the PMF can achieve about 95% reduction in gate size, as compared to the hard-limited signal based FIR filter, when the modulation index of the DSSS-CPFSK signal is equal to 1.5 and the sample rate is equal to 40 sample/chip.

Relationship between Hard Disk Surface Damage and Data Loss (하드디스크의 표면파손과 데이터 손실과의 관계)

  • 이성창;박용식;전규찬;김대은
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.2
    • /
    • pp.35-42
    • /
    • 2000
  • In recent years the recording density of hard disks has increased significantly largely due to the decreasing flying height. As a result of decreased flying height, the reliability issue become more critical. In this work the relationship between hard disk surface damage and data loss was investigated by using an actual hard disk drive. The purpose of this research was to identify the key factor which leads to data loss. It was shown that data loss is directly related to the physical damage of the Co-magnetic layer and there was no data loss when only carbon protective coating was damaged by the diamond tip.

  • PDF

A Study of the Effects of Hard Landing on Aircraft Structure (Hard Landing이 항공기 구조물에 미치는 영향성 연구)

  • Oh, Yong-Kyu;Sim, Sang-Ki;Shin, Ki-Su
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.14 no.5
    • /
    • pp.805-811
    • /
    • 2011
  • Aircraft MLG and wing structures have been recognized as fatigue critical structures and exposed to the risk of fatigue crack initiation and propagation. Furthermore, these structures are frequently subjected to serious dynamic loading condition during a Hard Landing which may lead to their failure. Especially, structural integrity of MLG and wing components is decreased as the flight time increased because of the fatigue damage accumulated on the aircraft. In this study, the effects of Hard Landing on the MLG and wing components of aging aircraft were evaluated by using numerical approach. To achieve the aim, a finite element model has been developed and simulations were conducted by varying the landing conditions. As a result, it was revealed that the high stress concentration phenomenon was occurred at the lower Side Brace of MLG. Thereby, the intensified inspection for the lower Side Brace should be considered to prevent unexpected aircraft mishap.