• Title/Summary/Keyword: Hand-Arm Vibration

Search Result 56, Processing Time 0.027 seconds

Assessment of Vibration Produced by Pneumatic Hand Tools Used in Automobile Assembly (자동차 조립공정에서 공기압력식 진동공구의 국소진동평가)

  • Kim, Sun Sul;Paik, Nam Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.6 no.1
    • /
    • pp.1-16
    • /
    • 1996
  • This study was conducted at an automobile assembly line located in Kyonggi-do, Korea from January 16 to February 28, 1995. The purposes of this study were to assess worker exposures to hand-arm vibration and the performance of gloves for reduction of vibration. The exposure to vibration was measured using to the ISO 5349(1986) method. Vibration acceleration and frequency spectra for each tool were determined on-line replicating actual working conditions and analyzed together with exposure time for evaluating individual worker exposure. Eight pneumatic hand tools, 60 workers exposured to hand-arm vibration, and three pairs of gloves were involved in this study. Results are summarized as follows. 1. Dominant frequencies of vibration for all tools(n=8) measured in this study ranged from 250 Hz to 800 Hz. 2. There was no significant correleration between dominant frequencies and free running speed (p>0.05). 3. Total predicted exposure times of using impact, hammer type did not exceed 40 minutes, but metal finish task, using grinder and sander exceeded 40 minutes. Total exposure time affected significantly the frequency-weighted, 4 hr equivalent acceleration. 4. Predicted prevalence and observed exposure period data were compared in workers(n=60), according to ISO 5349. In this results, 23(50.0 %) and 24(48.07 %) persons exceeded the mean latency periods for vibration-induced white finger(VWF) at 10 % (n=46) and 50 % (n=52) standards, respectively. On the basis of ISO equation, mean latent periods for VWF were 3.23, 4.72 years at 10 %, 50 % standards, respectively. 5. Reduction of vibration by gloves was evaluated. Since impact pneumatic tools produced low frequency vibrations, conventional gloves did not provide any protection. Gloves A and C amplify somewhat the signal at frequency below 400 Hz; the attenuation increases progressively by frequency to reach 18 dB ($7.94{\times}10^{-6}m/s^2$) at 1,000 Hz, slightly worsening Glove B did not provide any protection and made the situation slightly worse. However, since they make the hands warm, the occurrence of vibration-induced white fingers may be reduced.

  • PDF

Measuring hand kinematics in handball's game: A multi-physics simulation

  • Kun, Qian;Sanaa, Al-Kikani;H. Elhosiny, Ali
    • Earthquakes and Structures
    • /
    • v.23 no.6
    • /
    • pp.535-547
    • /
    • 2022
  • Handball sport, as its name postulates, is a team sport which highly physical workout. During a handball play, several ball impacts are applied on the hands resulting vibration in the forearm, upper arm, shoulders and in general in whole body. Hand has important role in the handball's game. So, understanding about the dynamics and some issues that improve the stability of the hand is important in the sport engineering field. Ulna and radius are two parallel bones in lower arm of human hand which their ends are located in elbow and wrist joint. The type of the joint provides the capability of rotation of the lower arm. These two bones with their ends conditions in the joints constructs a 4-link frame. The ulna is slightly thinner than radius. So, understanding about hand kinematics in handball's game is an important thing in the engineering field. So, in the current work with the aid of a multi-physics simulation, dynamic stability analysis of the ulna and radius bones will be presented in detail.

Assessment of Anti-vibration Gloves for Reduction of Hand-transmitted Vibration Exposure (수전달 진동 피폭 저감을 위한 방진 장갑의 성능 평가)

  • Choi, Seok Hyun;Hong, Seok In;Jang, Han Kee
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.18 no.1
    • /
    • pp.1-10
    • /
    • 2008
  • In order to evaluate performance of anti-vibration gloves, it is necessary to measure the transmitted vibration to the hand and the applied forces at the same time while gripping the vibrating handle. In the study a system was developed to measure both the vibration and the forces. The system consists of a measurement handle with eight strain gauges and two accelerometers and a PC-based system with a software for signal processing, evaluation of the hand-transmitted vibration and for control of applied forces in the pre-determined range. The handle was installed on the vibration shaker which is strong enough so as not to be affected by dynamic coupling with the hand-arm. Whole procedure of ISO 10819:1996 to determine the vibration transmissibility of anti-vibration gloves was programmed into the system. As an example of the application, three subjects joined the test to get vibration transmissibilities of 9 anti-vibration gloves where each glove was tested twice a subject. Average and standard deviation of the corrected vibration transmissibility were also calculated. All tested gloves fulfilled criterion for M-spectrum($\overline{TR_M}$<1.0), but one glove fulfilled criterion for H-spectrum($\overline{TR_H}$<6.0),

A Study on Rotary Weeding Blade Installation Angle for Reduction of Hand Vibration in Working Type Cultivator

  • Kwon, Tae Hyeong;Kim, Joonyong;Lee, Chungu;Kang, Tae Gyoung;Lee, Byeong-Mo;Rhee, Joong-Yong
    • Journal of Biosystems Engineering
    • /
    • v.39 no.1
    • /
    • pp.11-20
    • /
    • 2014
  • Purpose: Walking type cultivator used for weeding generated excessive handle vibration as well as bouncing motion depending on the weeding speed. This research was conducted to define a design factor of the rotary weeding blades for reducing soil reaction forces as well as hand vibration. Methods: The motion and forces acting on the rotary blades were reviewed to find out the most influencing parameter on hand vibration. The installation angle (IA) of the blade was selected and analyzed to determine the condition of no reaction force less. For removing the unnecessary upward soil reaction, the design factor theory of weeding blade was suggested based on geometrics and dynamics. For evaluation of design factor theory, the experiment in situ was performed base on ISO 5349:1. The vibration $a_{hv}$ and theoretical value $X_{MF}$ were compared with two groups that one was positive group ($X_{MF}$ > 0) and the other was negative group ($X_{MF}$ < 0). Results: $X_{MF}$ was derived from rotational velocity, forward velocity, disk diameter, weeding depth, blade's width and IA of blade. Two groups had significant difference (p < 0.05). In aspect of the group mean total exposure duration, positive group was 17.53% bigger than negative group. When disk radius 100, 150 and 200 mm, minimum IAs were $4{\sim}27^{\circ}$, $3{\sim}15^{\circ}$ and $2{\sim}10^{\circ}$, respectively. A spread sheet program which calculated XMF was developed by Excel 2013. Conclusions: According to this result, minimum IA of weeding blade for soil reaction reduction could be obtained. For reduction hand-arm vibration and power consumption, minimum IA is needed.

Simultaneous Measurement of Vibration and Applied Forces at a Power Tool Handle for the Reduction of Random Error When valuating Hand-transmitted Vibration (수전달 진동평가량의 랜덤오차 저감을 위한 공구 핸들에서의 진동과 작용력의 동시 측정)

  • Choi, Seok-Hyun;Jang, Han-Kee;Park, Tae-Won
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.4 s.97
    • /
    • pp.404-411
    • /
    • 2005
  • To increase accurateness and reliability of the evaluation of power tool vibration transmitted to an operator, it is necessary to measure the grip and feed forces during the measurement of hand-transmitted vibration. In the study a system was invented to measure the vibration and the grip and/or feed force, which consists of a measurement handle and a PC with a data acquisition system and the corresponding software. Strain gauges and an accelerometer were mounted on the handle surface for the simultaneous measurement of the forces and the vibration. The program in the system makes it possible to monitor the grip and feed force during the tool operation so that the operator keeps the applying forces within the pre-determined range. Investigating the vibration total values, frequency-weighted root-mean-square accelerations at the handle, obtained in repetition for each power tool with control of the grip and feed force showed more consistency than those measured without force control. By using the system the experimenter can reduce random error of the measured vibration.

The Simultaneous Measurement of Vibration and Applied forces at a Power tool handle for the Evaluation of Hand-transmitted Vibration (수전달 진동 평가를 위한 공구 핸들에서의 진동과 작용력의 동시 측정)

  • Choi, Seok-Hyun;Jang, Han-Kee;Park, Tae-Won
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.689-694
    • /
    • 2004
  • To increase accurateness and reliability of the evaluation of power tool vibration transmitted to an operator, it is necessary to measure grip and feed forces during the measurement of hand-transmitted vibration. In the study a system was invented to measure the vibration and the grip and/or feed force, which consists of a measurement handle and a PC with data acquisition system and the software. Strain gauges and an accelerometer were mounted on the handle for the simultaneous measurement of the forces and the vibration. The program in the system makes it possible to monitor the grip and feed force during the tool operation so that the operator keeps the applying forces within the pre-determined range. Investigating the vibration total values, frequency-weighted root mean square accelerations at the handle, obtained at various conditions with control of the grip and feed force showed more consistency than those measured without force control. By using the system the experimenter can reduce uncertainty of the measured vibration.

  • PDF

ISO Standards Related to Human Vibrations and Their Adaptation for KS Standards (인체 진동관련 ISO 표준안들의 국내 규격 적용)

  • Cheung, Wan-Sup
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.687-691
    • /
    • 2000
  • This paper reviews recent international standards related to human-related vibration and compares them to KS standards. This comparison and analysis reveals that the current direction and activity in ISO is in progress and presents logical ways of updating Korean standards in the future. Finally, the current activity of upgrading Korean standards in the Korean TC 108/SC 4 is introduced.

  • PDF

Development of the System for Measurement of the Vibration Transmissibility of an Anti-vibration Glove (방진 장갑 진동 전달률 측정 시스템 개발)

  • Choi, Seok-Hyun;Hong, Seok-In;Jang, Han-Kee;Park, Tae-Won
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.6 s.111
    • /
    • pp.602-608
    • /
    • 2006
  • In order to evaluate performance of anti-vibration gloves, it is necessary to measure the transmitted vibration to the hand and the applied forces at the same time while gripping the vibrating handle. In the study a system was developed to measure both the vibration and the forces. The system consists of a measurement handle with eight strain gauges and two accelerometers and a PC-based system with a software for signal processing and evaluation of the hand-transmitted vibration and for control of applied forces in the pre-determined range. The handle was installed on the vibration shaker which is strong enough so as not to be affected by dynamic coupling with the hand-arm system. Whole procedure of ISO 10819 to determine the vibration transmissibility of anti-vibration gloves was programmed into the system. As an example of the application, three subjects joined the test to get vibration transmissibilities of anti-vibration gloves where each glove was tested twice a subject. Average and standard deviation of vibration transmissibility were also calculated.

Combined Effect of Vibration Intensity, Grip Temperature, Noise and Pushing Power on Grip Forces and Skin Temperatures of Fingers (수지진동에서의 진동강도, 손잡이온도, 소음 및 미는 힘의 복합효과에 따른 악력 및 지단피부온의 변화)

  • Koh, Kyung-Sim;Griefahn, B.;Fritz, M.;Brode, P.
    • Journal of Preventive Medicine and Public Health
    • /
    • v.27 no.4 s.48
    • /
    • pp.763-776
    • /
    • 1994
  • Recent studies reveal that grip forces during the hand-arm vibration are most significant for the genesis of vibration-induced white linger syndrome. Therefore, exerted grip forces and skin temperatures of fingers were regarded as dependent variables in experiments and the effects of grip temperature, noise, pushing force, vibration and the combined effect of vibration and pushing force were studied. The objectives of the present study were, first, to varify and compare the changes of grip force affected by grip temperature, noise, pushing force, vibration and the combined effect of vibration and pushing force and, second, to observe the reaction of finger skin temperature affected by above factors. Forty-six healthy male students ($25.07{\pm}2.85$) participated in five systematically permuted trials, which endured 4 minutes each other. Experiments were executed in a special chamber with an air temperature of 21C. In each experiments, the subjects were exposed to five experiment types: (1) grip force of 25N only, (2) pushing force of 50N, (3) acceleration of vibration $7.1m/sec^2(z-direction)$, (4) pink noise of 95 dB (A) and (5) combination of pushing force 50N and acceleration of vibration $7.1m/sec^2$. A repeated-measures analysis of variance (ANOVA) was performed on the grip force to test whether it was affected by noise, pushing force, vibration and pushing force. The present results show that vibration was significantly related to the increase of grip force, but the other factors, such as pushing force, noise and grip temperature had no signigicant influence on the increase of grip force, and that the reaction of finger skin temperature were significantly affected by the skin temperature at start of experiment and grip temperature, not grip force and other experimental conditions. Therefore, we suggest that the management for decreasing the grip force is meaningful to prevent the occurrence of Hand-arm vibration syndrome (HAVS).

  • PDF