• Title/Summary/Keyword: Hand Shape

Search Result 970, Processing Time 0.033 seconds

CATHARE simulation results of the natural circulation characterisation test of the PKL test facility

  • Salah, Anis Bousbia
    • Nuclear Engineering and Technology
    • /
    • v.53 no.5
    • /
    • pp.1446-1453
    • /
    • 2021
  • In the past, several experimental investigations aiming at characterizing the natural circulation (NC) behavior in test facilities were carried out. They showed a variety of flow patterns characterized by an inverted U-shape of the NC flow curve versus primary mass inventory. On the other hand, attempts to reproduce such curves using thermal-hydraulic system codes, showed 10-30% differences between the measured and calculated NC mass flow rate. Actually, the used computer codes are generally based upon nodalization using single U-tube representation. Such model may not allow getting accurate simulation of most of the NC phenomena occurring during such tests (like flow redistribution and flow reversal in some SG U-tubes). Simulations based on multi-U-tubes model, showed better agreement with the overall behavior, but remain unable to predict NC phenomena taking place in the steam generator (SG) during the experiment. In the current study, the CATHARE code is considered in order to assess a NC characterization test performed in the four loops PKL facility. For this purpose, four different SG nodalizations including, single and multi-U-tubes, 1D and 3D SG inlet/outlet zones are considered. In general, it is shown that the 1D and 3D models exhibit similar prediction results up to a certain point of the rising part of the inverted U-shape of the NC flow curve. After that, the results bifurcate with, on the one hand, a tendency of the 1D models to over-predict the measured NC mass flow rate and on the other hand, a tendency of the 3D models to under-predict the NC flow rate.

An Estimation on Area Error For Surface Roughness Advancement of Rapid Prototype by FDM (FDM에서 단면오차법을 이용한 표면예측)

  • 전재억;김수광;황양오;박후명;하만경
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1869-1872
    • /
    • 2003
  • As SLA(Sterealithography), SLS(Selective Laser Sintering), LOM(Laminated Object Manufacturing), FDM(Fused Deposition Modeling) etc. The FDM system the heart of a study and is developed by Stratasys co. ltd, in US., is small and cheap R.P. The material filament is heated until the material reaches a near-liquid state, it is pumped through a nozzle and become hand with a shape required, and this nozzle move pumping on the previously deposited material. Such FDM system that choice deposition type with X-Y plouter obtain in the thin continue layer by decreasing amount of extrusion or to central the injection amount when the head slow down at the corner, but in the process that fusion wax or resin become hand, deformation occur and it will affect the shape accuracy and the surface roughness. Such effect will depreciate quality and reliability of the product. Therefore, when the product made in actuality, the fundamental study on the basis geometry(surface, volume, line, angle) must be preceded and it have been research by many Free Form Fabrication. So, this basic object study purpose to obtain the fundamental geometry data and to enhance the surface roughness of the shape. And an operant can use the data for the progress of the surface roughness. This study research the estimation and application of the prototype surface roughness by adjustment the injection amount. And basie of this research, describe the pattern of prototype surface roughness and also used the result to estimate the surface of prototype.

  • PDF

A Visual-perceptive Study on Closed and Open Forms of Ethnic Looks since the 1980s (1990년대 이후 에스닉 룩의 폐쇄형과 개방형의 시지각적 연구)

  • 서봉하
    • Journal of the Korean Society of Costume
    • /
    • v.54 no.4
    • /
    • pp.145-156
    • /
    • 2004
  • This study is regarding closed and open forms, which have relatively high recognition among visual perception phenomena in costumes. In particular, this study reviewed closeness and openness of ethnic look, which is a representative open costume. Closed form can be summarized as simple and clear silhouette, conspicuous differentiation from the background, simple construction of the costume and colors with low brightness and clearness. It Is modern, functional, rational and modest. On the other hand, open form can be summarized as complicated and inconspicuous edge line, complicated inner shape and colors with high brightness, high clearness and vividness. It includes concepts of pleasure, entertainment, joy, eroticism, rebel and resistance. Modern costumes have been simplified for a long time and they have functional and closed characteristics in their shape, structure and form. On the other hand, modern open form costumes are usually found in sub-cultural styles such as punk, hippie, kitsch and vintage, and some ethnic looks. Following is a summary of the characteristics of open form shown in the ethnic look. 1. The shape, structure of costumes, hair accessories, lace, ruffle and ornaments are complicated and irregular. 2. The silhouette is inconspicuous because of ambiguity between backgrounds and ABC (Apparel-Body-Construct) or the use of see-through materials. 3. It makes complicated visual shapes because it does not have a single type but is composed of various clothing items together. 4. It gives complex feelings by matching various colors or more than two different fabrics. 5. It looks like the open type because of the complex patterns shown in the costumes.

Moving Object Tracking Using Active Contour Model (동적 윤곽 모델을 이용한 이동 물체 추적)

  • Han, Kyu-Bum;Baek, Yoon-Su
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.5
    • /
    • pp.697-704
    • /
    • 2003
  • In this paper, the visual tracking system for arbitrary shaped moving object is proposed. The established tracking system can be divided into model based method that needs previous model for target object and image based method that uses image feature. In the model based method, the reliable tracking is possible, but simplification of the shape is necessary and the application is restricted to definite target mod el. On the other hand, in the image based method, the process speed can be increased, but the shape information is lost and the tracking system is sensitive to image noise. The proposed tracking system is composed of the extraction process that recognizes the existence of moving object and tracking process that extracts dynamic characteristics and shape information of the target objects. Specially, active contour model is used to effectively track the object that is undergoing shape change. In initializatio n process of the contour model, the semi-automatic operation can be avoided and the convergence speed of the contour can be increased by the proposed effective initialization method. Also, for the efficient solution of the correspondence problem in multiple objects tracking, the variation function that uses the variation of position structure in image frame and snake energy level is proposed. In order to verify the validity and effectiveness of the proposed tracking system, real time tracking experiment for multiple moving objects is implemented.

An Analysis According to the Shape on Formative Attributes of a Face (얼굴의 조형적 특성에 따른 유형 분석)

  • Kim, Ae-Kyung;Lee, Kyung-Hee
    • Fashion & Textile Research Journal
    • /
    • v.7 no.6
    • /
    • pp.650-656
    • /
    • 2005
  • The objective of this study is to analyze the formative attributes of face by measuring the shape and features of face. The faces of women in 20's were taken by digital camera and measured, then it has conducted a statistical analysis using a SPSS for factor analysis, correlation and cluster analysis. The findings are that it is consisted of six(6) different factors and it is responsible for 73.93%. In Factor 1 and Factor 2, it has explained the most significant factor to determine the shape of face. The result on cluster analysis is that it is classified into 5 groups and it is as follows. Attributes of each group is that Group 1 has a wide and long forehead, small and longish chin-line and chubby cheeks that represent polished and modern images, while Group 2 has small and longish forehead and chin-line that represent classical and mature images. On the other hand, Group 3 has a narrow forehead, small and longish chin-line and upward-style eyebrows that represents provocative images, whereas Group 4 has a shaped style that represent intellectual images and Group 5 has small and longish forehead and chin-line and cheekbones that represent polished and cute images.

Effect of the Ni Catalyst Size and Shape on the Variation of the Geometries for the As-grown Carbon Coils

  • Jang, Chang-Young;Kim, Sung-Hoon
    • Journal of the Korean institute of surface engineering
    • /
    • v.46 no.4
    • /
    • pp.175-180
    • /
    • 2013
  • Carbon nanofilaments (CNFs) could be synthesized using $C_2H_2/H_2$ as source gases and $SF_6$ as an incorporated additive gas under thermal chemical vapor deposition system. Ni powders were used as the catalyst for the formation of the CNFs. During the initial deposition stage, the initiation of the CNFs on the Ni catalyst was investigated. The geometries of the as-grown CNFs on Ni catalyst were strongly dependent on the size and/or the shape of Ni catalyst. Small size catalyst (<150 nm in diameter) gives rise to the unidirectional growth of the CNFs. On the other hand, large size catalyst (150~500 nm), the bidirectional growth of the CNFs could be observed. Particularly, the well faceted parallelogram-shaped Ni catalyst could give rise to the bidirectional growth of the CNFs having the symmetrically opposite direction. Eventually, these bidirectional growths of CNFs were understood to form the well-developed carbon microcoils (CMCs). Based on these results, the optimal shape and the size of the Ni catalyst to form the CMCs were discussed.

A Clinical Study About Difference Between Recognition of One's Own Body Figure and the Real Body Shape

  • Lee, Hee-Seung;Park, Sung-Sik
    • The Journal of Korean Medicine
    • /
    • v.28 no.4
    • /
    • pp.52-60
    • /
    • 2007
  • Objectives : The purpose of this study is to evaluate if the answers of questionnaires correlate with real body shapes and to evaluate if there are any differences between different types of questionnaires. Methods : We hand-measured body circumferences and body widths to analyze statistically answers of 9 questions from 2 different questionnaires. Also we compared two different types of questionnaires with Pearson product-moment correlation coefficient and two way ANOVA test. Results : There are significant correlations between answers of questions and all measured body circumferences and most body circumferences except for iliac width. Also answers of questionnaires even about the same chest part are not quite the same according to the opposite type of questionnaire after we compared grouping two of eight questions. Patients seem to have difficulty to recognizing if their necks are well-developed or not especially when the question asks about body shape when comparing two parts such as neck vs waist or chest vs buttock. Conclusions : There is general tendency of recognizing one's body shape properly. But also there are differences of recognition according to the type of questionnaire about the same body. So it is recommended to study more about the questionnaires.

  • PDF

BAM:Mn Phosphor Prepared from Spray Solution with Colloidal Silica (실리카 함유 콜로이달 분무용액으로부터 합성된 BAM:Mn 형광체)

  • Ju, Seo-Hee;Koo, Hye-Young;Hong, Seung-Kwon;Kim, Do-Youp;Kang, Yun-Chan
    • Korean Journal of Materials Research
    • /
    • v.16 no.2
    • /
    • pp.123-128
    • /
    • 2006
  • [ $BaMgAl_{10}O_{19}:Mn^{2+}$ ](BAM:Mn) phosphor particles with spherical shape were prepared by spray pyrolysis from colloidal solution with silica. The phosphor particles prepared by spray pyrolysis from aqueous solution had irregular morphology after high temperature post-treatment. On the other hand, the phosphor particles prepared from spray solution with colloidal silica had spherical shape after post-treatment. Colloidal silica used as additive improved the spherical shape and filled morphology of the precursor particles prepared by spray pyrolysis. The precursor particles with filled structure produced the BAM:Mn phosphor particles with spherical shape and non-aggregation characteristics after post-treatment at $1400^{\circ}C$ under reducing atmosphere. The phosphor particles prepared from colloidal solutions formed the crystal structure of BAM:Mn phosphor irrespective of the silica contents. The BAM:Mn phosphor particles prepared from aqueous and colloidal solutions had similar photoluminescence intensities under vacuum ultraviolet.

Preparation of Green-Light Emitting BAM:Mn Phosphor Particles by High Temperature Spray Pyrolysis (고온 분무열분해 공정에 의한 녹색 발광의 BAM:Mn 형광체 합성)

  • Ju Seo Hee;Koo Hye Young;Kim Do Youp;Kang Yun Chan
    • Korean Journal of Materials Research
    • /
    • v.15 no.8
    • /
    • pp.496-502
    • /
    • 2005
  • Green-light emitting $BaMgAl_{10}O_{19}:Mn^{2+}$ (BAM:Mn) phosphor particles were prepared by spray Pyrolysis. The effect of reactor temperature and flow rate of carrier gas in the spray Pyrolysis on the morphology, crystallinity and photoluminescence characteristics under vacuum ultraviolet were investigated. The morphology of the as-Prepared Particles obtained by spray Pyrolysis had spherical shape and non-aggregation characteristics regardless of the reactor temperature. The spherical shape of the as-prepared Particles obtained by spray pyrolysis at low temperature disappeared after Post-treatment. On the other hand the as-Prepared Particles obtained by spray Pyrolysis at $1600^{\circ}C$ maintained spherical shape and non-aggregation characteristics after post-treatment at $1400^{\circ}C$ for 3 h under reducing atmosphere. The BAM:Mn Phosphor Particles Prepared by spray Pyrolysis at different reactor temperatures had pure crystal structure and high photoluminescence intensities under vacuum ultraviolet after post-treatment. BAM:Mn phosphor particles prepared by spray Pyrolysis at low How rate of carrier gas had complete spherical shape and filed morphology and high photoluminescence intensity after post-treatment under reducing atmosphere.

Morphing Wing Mechanism Using an SMA Wire Actuator

  • Kang, Woo-Ram;Kim, Eun-Ho;Jeong, Min-Soo;Lee, In;Ahn, Seok-Min
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.13 no.1
    • /
    • pp.58-63
    • /
    • 2012
  • In general, a conventional flap on an aircraft wing can reduce the aerodynamic efficiency due to geometric discontinuity. On the other hand, the aerodynamic performance can be improved by using a shape-morphing wing instead of a separate flap. In this research, a new flap morphing mechanism that can change the wing shape smoothly was devised to prevent aerodynamic losses. Moreover, a prototype wing was fabricated to demonstrate the morphing mechanism. A shape memory alloy (SMA) wire actuator was used for the morphing wing. The specific current range was measured to control the SMA actuator. The deflection angles at the trailing edge were also measured while various currents were applied to the SMA actuator. The trailing edge of the wing changed smoothly when the current was applied. Moreover, the deflection angle also increased as the current increased. The maximum frequency level was around 0.1 Hz. The aerodynamic performance of the deformed airfoil by the SMA wire was analyzed by using the commercial program GAMBIT and FLUENT. The results were compared with the results of an undeformed wing. It was demonstrated that the morphing mechanism changes the wing shape smoothly without the extension of the wing skin.