• Title/Summary/Keyword: Hand Movement

Search Result 820, Processing Time 0.02 seconds

The Effects of Constraint-induced Movement Therapy on the Involved Hand Function and ADL in Stroke Patients (건측억제유도운동이 뇌졸중 환자의 손 기능과 일상생활능력에 미치는 영향)

  • Kim, Young-Mi;Hwang, Yoon-Tae;Park, Rae-Joon
    • The Journal of Korean Physical Therapy
    • /
    • v.17 no.4
    • /
    • pp.493-504
    • /
    • 2005
  • The purpose of this study is to determine the effect of constraint-induced movement therapy on the involved hand function and ADL in stroke patients. Five subjects with fixing unaffected arms by CIMT were assigned to the experimental patient group and the other five patients to control group without fixing unaffected arms. The function of hand for both groups were evaluated by using Jebsen-Taylor hand function test and ADL for both groups were evaluated by FIM(Functional Independence Measure) before and after task practice. In conclusion, results of this study showed that improved hand function and ADL by CIMT in stroke patients. We concluded that CIMT can improved the involved hand function and ADL in stroke patients.

  • PDF

Eye-hand coordination in press task (프레스 작업에서 눈과 손의 협응동작에 대한 연구)

  • 박경수;김유창
    • Journal of the Ergonomics Society of Korea
    • /
    • v.16 no.1
    • /
    • pp.63-71
    • /
    • 1997
  • This paper presented an experiment which examined eye and hand movement characteristics of novice and experienced workers in the press operation. Continuous recordings of eye and hand movements were made on five novice operators and five experienced operators in press operation. Significant difference between the novice and the experienced operators was observed in eye fixation time, eye movement patterns, hand dwell time, and eye-hand coordination. Also, differences were observed in spatial distribution of eye fixations during the die-closing portion of a stroke. There were no significant differences between the novice and the experiencedoperators in the eye and the hand movement time. The results could be used to establish a guide determining the method and training period to train the novice operators.

  • PDF

HAND GESTURE INTERFACE FOR WEARABLE PC

  • Nishihara, Isao;Nakano, Shizuo
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2009.01a
    • /
    • pp.664-667
    • /
    • 2009
  • There is strong demand to create wearable PC systems that can support the user outdoors. When we are outdoors, our movement makes it impossible to use traditional input devices such as keyboards and mice. We propose a hand gesture interface based on image processing to operate wearable PCs. The semi-transparent PC screen is displayed on the head mount display (HMD), and the user makes hand gestures to select icons on the screen. The user's hand is extracted from the images captured by a color camera mounted above the HMD. Since skin color can vary widely due to outdoor lighting effects, a key problem is accurately discrimination the hand from the background. The proposed method does not assume any fixed skin color space. First, the image is divided into blocks and blocks with similar average color are linked. Contiguous regions are then subjected to hand recognition. Blocks on the edges of the hand region are subdivided for more accurate finger discrimination. A change in hand shape is recognized as hand movement. Our current input interface associates a hand grasp with a mouse click. Tests on a prototype system confirm that the proposed method recognizes hand gestures accurately at high speed. We intend to develop a wider range of recognizable gestures.

  • PDF

Movement Characteristic Analysis for Unconstrained Sleep Efficiency Analysis Based on the Smartphone (무구속 수면효율 분석을 위한 스마트폰 기반 움직임패턴 특성분석)

  • Kim, Do Yoon;Shin, Hangsik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.7
    • /
    • pp.940-944
    • /
    • 2014
  • In this research, we designed representative motion patterns that possibly occurred in sleep situation and evaluated the feasibility of the smartphone based movement recording technique. For this, we designed 7 motions such as posture change, head movement, arm movement (vertical, horizontal), leg movement and hand movement (flipping, folding). Movement was recorded by using the smartphone and the actimetry device simultaneously for comparing the feasibility of smartphone based recording. As a result of experiment, we found that the smartphone based movement recording well reflects the body movement, however, it shows the limitation in recording the small local movement such as hand motion compared with the reference actimetry device, Actiwatch.

A Structure and Framework for Sign Language Interaction

  • Kim, Soyoung;Pan, Younghwan
    • Journal of the Ergonomics Society of Korea
    • /
    • v.34 no.5
    • /
    • pp.411-426
    • /
    • 2015
  • Objective: The goal of this thesis is to design the interaction structure and framework of system to recognize sign language. Background: The sign language of meaningful individual gestures is combined to construct a sentence, so it is difficult to interpret and recognize the meaning of hand gesture for system, because of the sequence of continuous gestures. This being so, in order to interpret the meaning of individual gesture correctly, the interaction structure and framework are needed so that they can segment the indication of individual gesture. Method: We analyze 700 sign language words to structuralize the sign language gesture interaction. First of all, we analyze the transformational patterns of the hand gesture. Second, we analyze the movement of the transformational patterns of the hand gesture. Third, we analyze the type of other gestures except hands. Based on this, we design a framework for sign language interaction. Results: We elicited 8 patterns of hand gesture on the basis of the fact on whether the gesture has a change from starting point to ending point. And then, we analyzed the hand movement based on 3 elements: patterns of movement, direction, and whether hand movement is repeating or not. Moreover, we defined 11 movements of other gestures except hands and classified 8 types of interaction. The framework for sign language interaction, which was designed based on this mentioned above, applies to more than 700 individual gestures of the sign language, and can be classified as an individual gesture in spite of situation which has continuous gestures. Conclusion: This study has structuralized in 3 aspects defined to analyze the transformational patterns of the starting point and the ending point of hand shape, hand movement, and other gestures except hands for sign language interaction. Based on this, we designed the framework that can recognize the individual gestures and interpret the meaning more accurately, when meaningful individual gesture is input sequence of continuous gestures. Application: When we develop the system of sign language recognition, we can apply interaction framework to it. Structuralized gesture can be used for using database of sign language, inventing an automatic recognition system, and studying on the action gestures in other areas.

Study on Spatio-Temporal Eye-Hand Coordination in Targeting Tasks (지시운동 수행동안 안구와 손의 시공간적 협응에 관한 연구)

  • Eun, H.I.;Yu, M.;Lee, A.R.;Kim, D.W.;Kwon, T.K.;Kim, N.G.
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.3
    • /
    • pp.417-422
    • /
    • 2007
  • In this study, we investigated spatio-temporal eye-hand coordination by the "Global effect paradigm", a target-distracter configuration Global effect is observed a variety of visual tasks, for example, during rapid automatic tracking, scanning for target detail, and the comparison of target configurations. Global effect used to investigate eye-hand coordination with a task that presents a target close to a distracter. Eight young subjects participated in the experiments. The experiments consist of using a distracter less eccentric than the targe1 and using a distracter more eccentric than target. Each experiment consist of tasks which are making reference, pointing the target with watching visual stimulation(saccade) and pointing the target. The subject's task was to move towards the target as quickly as possible. We measured the eye movement by using EOG and the hand movement by using NDI Optotrak system. This study shows that eye and hand movement exists for global effect paradigm in spatio-temporal coordination.

A Study on the Interaction with Virtual Objects through XR Hands (XR Hands를 통한 가상 객체들과의 상호 작용에 관한 연구)

  • BeomJun Jo;SeongKi Kim
    • Journal of the Korea Computer Graphics Society
    • /
    • v.30 no.3
    • /
    • pp.43-49
    • /
    • 2024
  • Hand tracking is currently one of the most promising technologies in XR with the release of extended reality (XR) devices, in which hand tracking is used as the main manipulation. Hand tracking offers advantages in terms of immersion and realism, and as a result, it is being employed in a range of fields, including education, business, and medical care. The archery movement requires using both hands at the same time, but requires sophistication to hit the target and is a movement that has cultural and sports significance in the past. This study aimed to implement this archery movement. Therefore, this paper used the XR Hands package provided by Unity to recognize hand movements, explored the underlying OpenXR, and finally implemented the archery movement and tested it in Meta Quest 2.

A Research on BCI using Coherence between EEG and EMG (EEG와 EMG의 Coherence을 이용한 BCI 연구)

  • Kim, Young-Joo;Whang, Min-Cheol;Kang, Hee
    • Journal of the Ergonomics Society of Korea
    • /
    • v.27 no.2
    • /
    • pp.9-14
    • /
    • 2008
  • Coherence can be used to evaluate the functional cortical connections between the motor cortex and muscle. This study is to find coherence between EEG (electroencephalogram) and EMG (electromyogram) evoked by movement of a hand. Seven healthy participants were asked to perform thirty repetitive movement of right hand for ten seconds with rest for ten seconds. Specific feature of EEG components has been extracted by ICA (independent component analysis) and coherence between EEG and EMG was analyzed from data measured EEG in five local areas around central part of head and EMG in flexer carpri radialis muscle during grabbing movement. Coherence between EEG and EMG was successfully obtained at 0.025 confidence limit during hand movement and showed significant difference between rest and movement at 13-18Hz.

An Experimental study on the gap of movement by the hinge articulator (단순교합기에 의한 하악운동의 오차에 대한 실험적 연구)

  • Moon, Hee-Kyung
    • Journal of Technologic Dentistry
    • /
    • v.25 no.1
    • /
    • pp.111-118
    • /
    • 2003
  • I measured the movement range on the hinge articulator and the movement range in an oral. And then I studied to analyze the gap. I got wax records by the movement on the hinge articulator, the movement in an oral and the movement on the hand articulating. I measured the distance of the cusp tips that are close to the mesial direction and the distal direction, the buccal direction and the lingual direction then I compared gaps. As I saw results on data, I knew that the hinge articulator represented the range of mandibular movement restrictively. I could find the decisive contradiction that the sliding movement finished on the hinge articulator although it did not finish in an oral. If the sliding movement does not reappear exactly, it brings a fatal failure to the dental prosthesis. In addition it is impossible that the hinge articulator restores the movement in an oral because the lateral condyle inclination and the horizontal condyle inclination are fixed previously. Therefore dental prosthesisses were made by the hinge articulator, they will interfere with a mastication. I have obtained the following results; 1. The distance of sliding movement on the hinge articulator showed shorter than the distance of sliding movement in oral. This means the increase of cusp inclination of the dental prosthesis that was made on the hinge articulator. Therefore, when the lateral movement occurs in oral, there is a possibility to become the premature as the increase of cusp inclination. 2. The results that were impressed records in oral and impressed records on the hand articulating have many congruities. I think that the simple crown etc. that were made by the hand articulating method except the long span bridge and the free end case that can not measure the vertical dimension exactly can represent similarly the mandibular movement. 3. If we want to represent the mandibular movement similarly, we have to use the articulator that can adjust the horizontal condyle inclination and the lateral condyle inclination at least.

  • PDF

Hand Pressing Control Using the Five-Axis Force/Moment Sensor of Finger Rehabilitation (손가락 재활로봇의 5축 힘/모멘트센서를 이용한 손 누름제어)

  • Kim, Hyeon-Min;Kim, Gab-Soon
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.3
    • /
    • pp.192-197
    • /
    • 2012
  • This paper describes the control of the hand fixing system attached to the finger rehabilitation robot for the rehabilitation exercise of patient's fingers. The finger rehabilitation robot is used to exercise the finger rehabilitation, and a patient's hand is safely fixed using the hand fixing system. In this paper, the hand fixing system was controlled with PD gains to fix a palm of the hand, and the characteristic test for the hand fixing system was carried out to sense the fixed hand movement of the front and the rear, that of the left and the right, and that of the upper. It is thought that the hand fixing system could safely fix the hand, and the movement of the fixed hand could be perceived using the five-axis force/moment sensor attached to the hand fixing system.