• 제목/요약/키워드: Half-Plane

검색결과 453건 처리시간 0.024초

ABOw/AC4CH의 바인더 종류에 따른 파괴인성 및 미끄럼마모 특성 (Fracture Toughness and Slinding Wear Properties of ABOw/AC4CH by Binder Additives)

  • 박원조;정재욱;최용범;이광영
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2002년도 추계학술대회 논문집
    • /
    • pp.373-378
    • /
    • 2002
  • Metal matrix composites have a great interest in recent years because high specific strength, high specific stiffness characteristics, and application ranges of the composites are extend to variety industry. In this paper, an investigation was performed on the plane strain fracture toughness and slinding wear properties of AC4CH alloy(Al-Si-Mg line) reinforced with 20wt% aluminum borate whisker expect one, which contained a inorganic binder($TiO_2$). the binder led to the formation of strengthen the whisker each other. The test of fracture toughness was using CT(half size) specimen of thickness 12.5mm, width 25mm. and test of slinding wear of using tribo a pin-on-disk machine and lubricant is used without paraffine 8.2CST at room temperature. As results, Fracture toughness $K_{IC}$ is $8.7MPa-m^{05}$ for ABOw/AC4CH, $9.28MPa-m^{05}$ for ABOw/AC4CH added $TiO_2$. but AC4CH alloy was violated the critical stipulated by ASTM standard for valid measurement of $K_{IC}$. In case of, it was performed $J_{IC}$ test instead of $K_{IC}$ based on ASTM E 1820.

  • PDF

티타늄 박막을 이용한 자동차 타이어 압력센서 (Automotive Tire Pressure Sensors with Titanium Membrane)

  • 채수
    • 실천공학교육논문지
    • /
    • 제6권2호
    • /
    • pp.105-110
    • /
    • 2014
  • 본 연구에서는 강한 내구성을 지닌 자동차 타이어용 압력센서를 개발하기 위해 박막 물질로서 적용될 티타늄 멤브레인의 기계적 특성이 연구되었다. 제작공정으로 기존의 마이크로 머시닝공정과 적층 공정기술이 동시에 적용되었으며, 티타늄 멤브레인 기반의 압력 센서가 설계, 제조 및 특성화 되었다. 마이크로 머시닝 공정을 통한 티타늄 멤브레인과 기판의 접합 제조과정은 30분 동안의 20 MPa의 압력과 $200^{\circ}C$의 온도과정 후 $24^{\circ}C$에서의 냉각으로 진행된다. 각각의 압력센서 표면은 니켈 도금된 후방전극이 기판 위에 마이크로 소자로 조립되었다. 제작과정에서 발생한 잔류응력을 예측하기 위해 유한요소 해석이 적용되었다. 또한 티타늄 멤브레인의 외부 압력하에서 변형에 의한 처짐이 계산되었다. 제작된 장치의 민감도는 $10.15ppm\;kPa^{-1}$ 였고 이때의 정전용량 변화량은 0.18 pF, 압력 범위는 0-210 kPa 였다.

초전도 박막선재용 IBAD-MgO 박막 증착 (Deposition of IBAD-MgO for superconducting coated conductor)

  • 하홍수;김호겸;양주생;고락길;김호섭;오상수;송규정;박찬;유상임;주진호;문승현
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 하계학술대회 논문집 Vol.6
    • /
    • pp.282-283
    • /
    • 2005
  • Ion beam assisted deposition(IBAD) technique was used to produce biaxially textured polycrystalline MgO thin films for high critical current YBCO coated conductor. Hastelloy tapes were continuous electropolished with very smooth surface for IBAD-MgO deposition, RMS roughness of Hastelloy tape values below 2 nm and local slope of less than $1^{\circ}$. After the polishing of the tape an amorphous $Y_2O_3$ and $Al_2O_3$ are deposited Biaxially textured MgO was deposited on amorphous layer bye-beam evaporation with a simultaneous bombardment of high energy ions. We had developed the RHEED to measure in-situ biaxial texture of film surface as thin as tens angstrom. And also ex-situ characterization of buffer layers was studied using XRD and SEM. The full-width at half maximum(FWHM) out of plane texture of IBAD-MgO template is $4^{\circ}$.

  • PDF

세 물체 간 마찰 완전 접촉 문제의 응력 특이성 거동 (Stress Singularity Behaviour in the Frictional Complete Contact Problem of Three Bodies)

  • 김형규
    • Tribology and Lubricants
    • /
    • 제35권4호
    • /
    • pp.229-236
    • /
    • 2019
  • This study investigates the stress singularity that occurs at the contact edge of three bodies in a frictional complete contact. We use the asymptotic analysis method, wherein we constitute an eigenvalue problem and observe the eigenvalue behavior, which we use to obtain the order of the stress singularity. For the present geometry of three bodies in contact, a contact between a cracked indenter and half plane is considered. This is a typical geometry of the PCMI problem of a nuclear fuel rod. Thus, this paper, specifically presents the characteristics of the PCMI problem from the perspective of stress singularity. Consequently, it is noted that the behavior of the stress singularity varies with the difference in the crack angle, coefficient of friction, and material dissimilarity, as is observed in a frictional complete contact of two bodies. In addition, we find that the stress singularity changes essentially linearly with respect to the coefficient of friction, regardless of the variation in the crack angle and material dissimilarity. Concurrently, we find the order of singularity to be 0.5 at a certain coefficient of friction, irrespective of the crack angle, which we also observe in the crack problem of a homogeneous and isotropic body. The order of singularity can also exceed 0.5 in the frictional complete contact problem of three bodies. This implies that the propensity for failure when three bodies are in frictional complete contact can be even worse than that in case of a failure induced by a crack.

무선 랜과 WiMAX 응용을 위한 삼중 대역 삼중 다이폴 준-야기 안테나 설계 (Design of Triple-band Triple Dipole Quasi-Yagi Antenna for WLAN and WiMAX Applications)

  • 여준호;이종익
    • 한국항행학회논문지
    • /
    • 제26권1호
    • /
    • pp.29-34
    • /
    • 2022
  • 본 논문에서는 2.45 GHz 및 5 GHz 무선 랜 주파수 대역과 3.5 GHz WiMAX 주파수 대역에서 동작하는 삼중 다이폴 준-야기 안테나의 설계에 대하여 연구하였다. 제안된 준-야기 안테나는 V-모양 접지면과 직렬로 연결된 세 개의 다이폴로 구성된다. 길이가 가장 긴 반-보우타이 모양의 다이폴은 2.45 GHz 대역에서 공진하고, 중간 길이의 다이폴은 3.5 GHz에서 공진한다. 길이가 가장 짧은 다이폴은 5 GHz 대역에서 공진한다. 다이폴의 길이와 폭, 다이폴 사이의 간격을 조절하여 2.45 GHz, 3.5 GHz 및 5 GHz 대역에서 동작하는 삼중 대역 지향성 안테나를 설계하였고, FR4 기판 상에 45 mm × 55 mm 크기로 제작하였다. 제작된 안테나는 전압 정재파비가 2 이하인 대역이 2.32-2.57 GHz, 3.26-3.69 GHz, 4.50-6.56 GHz로 설계된 삼중 대역에서 동작하는 것을 확인하였다. 이득은 세 대역에서 3 dBi 이상을 유지하였다.

Reducing pain and opioid consumption after body contouring of the breast by application of a perioperative nerve block: a systematic review

  • Asserson, Derek B.;Sahar, David E.
    • Archives of Plastic Surgery
    • /
    • 제48권4호
    • /
    • pp.361-365
    • /
    • 2021
  • Background Pain in the postoperative body contouring patient has traditionally been managed with narcotic medication. In an effort to minimize side effects and prevent addiction, plastic surgeons are searching for novel ways to provide adequate analgesia, one of which is nerve blocks. This study was conducted with a meta-analysis that evaluates the efficacy of these blocks for patients who undergo breast surgery. Methods A search of the PubMed/MEDLINE database for articles including the terms "post-operative analgesia" OR "postoperative pain management" AND "in plastic surgery" OR "in cosmetic surgery" OR "in elective surgery" in February 2019 generated five studies on elective breast augmentation and reduction mammoplasty that reported pain scores and quantities of opioids consumed. Independent samples t-tests, one-way analysis of variance, and a random effects model were implemented for evaluation. Results A total of 317 patients were identified as having undergone body contouring of the breast, about half of which received a nerve block. Pain scores on a 1-10 scale and opioid dose-equivalents were calculated. Those who were blocked had an average score of 2.40 compared to 3.64 for those who did not (P<0.001), and required an average of 5.20 less narcotic doses (P<0.001). Pain relief following subpectoral augmentation was best achieved with type-II blocks as opposed to type-I and type-II with serratus plane (P<0.001). Conclusions The opioid epidemic has extended to all surgical specialties. Implementation of a nerve block seems to be an efficacious and cost-effective mechanism to not only help with post-operative pain, but also lower the need for narcotics, especially in subpectoral augmentation.

초전도 선재용 완충층의 결정성장 연구 (Epitaxial growth of buffer layers for superconducting coated conductors)

  • 정국채;유재무;김영국
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제9권3호
    • /
    • pp.5-8
    • /
    • 2007
  • All three buffer layers of $Y_2O_3$, YSZ, and $CeO_2$ have been deposited on the biaxially textured metal substrates using rf-sputtering method, The first 50-70nm thick $Y_2O_3$ films were grown epitaxially on biaxially textured metal substrates as a seed layer and followed by the diffusion barrier ${\sim}100nm$ thick YSZ and subsequent capping layer ${\sim}200nm$ thick $CeO_2$ deposited epitaxially on top of $Y_2O_3$ seed layer. The epitaxial orientation of all three layers were all (100) grown with rocking curve Full Width at Half Maximum(FWHM) of $4-5^{\circ}$ and in plane phi-scan FWHM of $6-8^{\circ}$ using X -ray diffraction analysis. The NiO phases formed during the $Y_2O_3$ seed layer deposition seem to degrade the crystallinity and roughen the surface morphology of the following layer observed by AFM(Atomic Force Microscopy). The buffered tapes were used as substrates for long length YBCO coated conductors with high critical current density $J_c$. The five multi-turn of metal tapes was employed to increase the thickness of films and production rate to compensate the low growth rate of rf-sputtering method.

교합조건 및 이악물기 힘의 변화가 하악의 비틀림 회전운동에 미치는 영향 (Effects of Occlusal Condition and Clenching Force on the Mandibular Torque Rotational Movement)

  • 오민정;한경수
    • Journal of Oral Medicine and Pain
    • /
    • 제30권4호
    • /
    • pp.411-426
    • /
    • 2005
  • 이갈이나 이악물기 시 근활성, 하악의 이동, 악관절에 가해지는 부하, 그리고 교합에 미치는 영향 등에 대한 연구는 많았으나 하악운동에 미치는 영향에 대해서는 연구가 적었다. 따라서 측두하악장애의 주요한 기여요인으로 간주되는 이악물기나 강한 씹기에 의해 나타나는 하악의 미세한 운동양태에 대해서는 더 많은 연구가 수행될 필요가 있으며, 이에 본 연구에서는 하악의 비틀림 회전운동을 중심으로 이악물기 및 강한 씹기의 영향을 조사하였다. 저작계 이상이 없는 건강한 남자 14명을 선정하여 교합고경 및 형태의 변화와 수의적 이악물기 수준의 차이가 이악물기 및 씹기 운동 시 나타나는 하악의 비틀림 회전운동(torque rotational movement)에 미치는 영향을 조사하였다. 각 교합조건과 이악물기 힘에서의 씹기 운동은 먼저 나무젓가락(분리기)이 없는 한 번의 이악물기와 나무젓가락을 구치부에 위치시킨 상태에서 두 번에 걸친 씹는 운동 등 세 번의 하악운동으로 구성되었다. 본 연구의 결론은 다음과 같다. 1. 좌측으로 씹을 때와 우측으로 씹을 때 간에 전두면 및 시상면상 운동거리는 두 가지 이악물기 힘 모두에서 차이가 없었으나 하악의 운동속도는 다른 양상을 보여 강한 이악물기에서는 차이가 없었으나 약한 이악물기에서는 좌측으로 씹을 때 우측에 비해 속도가 다소 빠른 경향을 보였다. 이때 하악의 비틀림 회전운동각은 두 가지 이악물기 모두에서 전두면상 차이는 거의 없었으나 수평면상 각도에서는 씹는 측에 따라 차이가 있는 경향을 보였다. 2. 이악물기 힘의 차이는 전두면 및 시상면상 운동거리와 속도에 영향을 미쳐 강한 씹기에서 약한 씹기에 비해 측정치가 크게 나타났으며 하악의 비틀림 회전운동각 역시 강한 씹기에서 수평면상 운동각이 다소 증가된 양상을 보였다. 3. 전두면 및 시상면상 개구거리는 교합조건에 따른 차이를 보였는데, 즉 웨이퍼나 레진블록 등 교합고경이 높은 교합형태일수록 운동거리가 감소하였으며, 이때 강한 씹기에서는 운동속도 역시 유사한 양상으로 감소하였다. 그러나 하악의 비틀림 회전운동각은 전두면 및 수평면 모두에서 교합조건에 따른 차이를 거의 나타내지 않았다. 4. 세 번의 씹는 운동에서 분리기가 없는 경우에 비해 있는 경우에서 대체로 전두면상 회전운동각을 제외한 나머지 하악의 비틀림 회전운동량은 모두 증가하는 양상을 보였다. 그러나 이때 각 교합형태 간 동일항목의 비교에서는 전두면상 회전운동거리가 이악물기 힘에 따른 차이를 보여 약한 이악물기에서 유의한 변화를 나타내었다. 이상의 연구를 통해 하악 비틀림 회전운동의 전체적인 양상은 관찰면에 따라 다르게 나타나 이악물기 힘에 따른 차이는 전두면에 비해 수평면상 측정치가 더 많이 변화되는 모습을 보였으나 교합조건에 따른 양상은 관찰면 간 차이를 보이지 않았다. 한편 이악물기 및 씹는 운동 각각에서의 하악 비틀림 회전운동량은 교합조건이나 이악물기 힘에 관계없이 대체로 분리기 씹기에 의해 수평면상 회전운동량의 변화가 전두면상 측정치에 비해 더 유의하게 나타났다.

Study of the Efficiency Droop Phenomena in GaN based LEDs with Different Substrate

  • Yoo, Yang-Seok;Li, Song-Mei;Kim, Je-Hyung;Gong, Su-Hyun;Na, Jong-Ho;Cho, Yong-Hoon
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제43회 하계 정기 학술대회 초록집
    • /
    • pp.172-173
    • /
    • 2012
  • Currently GaN based LED is known to show high internal or external efficiency at low current range. However, this LED operation occurs at high current range and in this range, a significant performance degradation known as 'efficiency droop' occurs. Auger process, carrier leakage process, field effect due to lattice mismatch and thermal effects have been discussed as the causes of loss of efficiency, and these phenomena are major hindrance in LED performance. In order to investigate the main effects of efficiency loss and overcome such effects, it is essential to obtain relative proportion of measurements of internal quantum efficiency (IQE) and various radiative and nonradiative recombination processes. Also, it is very important to obtain radiative and non-radiative recombination times in LEDs. In this research, we measured the IQE of InGaN/GaN multiple quantum wells (MQWs) LEDs with PSS and Planar substrate using modified ABC equation, and investigated the physical mechanism behind by analyzing the emission energy, full-width half maximum (FWHM) of the emission spectra, and carrier recombination dynamic by time-resolved electroluminescence (TREL) measurement using pulse current generator. The LED layer structures were grown on a c-plane sapphire substrate and the active region consists of five 30 ${\AA}$ thick In0.15Ga0.85N QWs. The dimension of the fabricated LED chip was $800um{\times}300um$. Fig. 1. is shown external quantum efficiency (EQE) of both samples. Peak efficiency of LED with PSS is 92% and peak efficiency of LED with planar substrate is 82%. We also confirm that droop of PSS sample is slightly larger than planar substrate sample. Fig. 2 is shown that analysis of relation between IQE and decay time with increasing current using TREL method.

  • PDF

공통 결함접지구조를 이용한 소형화된 저역통과여파기의 설계 (Design of A Miniaturized Low Pass Filter Using Common Defected Ground Structure)

  • 이준;이재훈;임종식;안달
    • 한국산학기술학회논문지
    • /
    • 제12권5호
    • /
    • pp.2298-2304
    • /
    • 2011
  • 본 논문에서는 공통 결함접지구조(common defected ground structure, CDGS)를 이용한 초고주파 대역의 저역통과여파기(low pass filter, LPF) 소형화 설계에 대하여 기술한다. 기존의 연구에서는 표준형 LPF보다 약간 소형화된 DGS 적용의 LPF를 설계하는 방법을 제시하는데 그쳤으나, 본 논문에서는 공통 DGS 구조를 이용하여 종래의 회로보다 절반의 크기로 줄이는 방법을 제시한다. 공통 DGS는 양면의 마이크로스트립 전송선로의 공통 접지면에 구현된다. 본 논문에서는 예로써, 비유전율이 2.2이고 두께가 31mils인 유전체 기판을 이용하여 양면 마이크로스트립 전송선로 구조와 공통 DGS를 구성하고, 이를 활용하여 소형화된 LPF를 설계하고, 실제로 제작 및 측정하여 제안하는 방법의 타당성을 검증한다. 최종적으로 설계된, 공통 DGS를 지니는 LPF는 기존의 단층 구조에서 DGS를 지니는 LPF에 비하여 52.6%의 크기를 가지면서도, 측정된 성능은 반사계수가 -22dB 이하이고 삽입손실이 0.19dB 이하로 여전히 우수함을 보여준다.