• 제목/요약/키워드: Half-Bridge Topology

검색결과 129건 처리시간 0.031초

듀얼 하프브리지 컨버터를 사용하는 파워 디커플링 DC/AC 인버터 (Power Decoupling of Single-phase DC/AC inverter using Dual Half Bridge Converter)

  • 모하마드 사미르 이르판;아쉬라프 아메드;박종후
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2015년도 전력전자학술대회 논문집
    • /
    • pp.421-422
    • /
    • 2015
  • Nowadays, bidirectional DC-DC converters are becoming more into picture for different applications especially electric vehicles. There are many bidirectional DC-DC converters topologies; however, voltage-fed Dual Half-Bridge (DHB) topology has less number of switches as compared to other isolated bidirectional DC-DC converters. Furthermore, voltage fed DHB has galvanic isolation, high power density, reduced size, high efficiency and hence cost effective. Electrolytic capacitors always have problem regarding size and reliability in DC-AC single phase inverters. Therefore, voltage-fed DHB converter is proposed for the purpose of power decoupling to replace electrolytic capacitor by film capacitors. A new control strategy has been developed for 120Hz ripple rejection, and it was verified by simulation.

  • PDF

노트북 컴퓨터 어댑터용 LLC 하프 브리지 공진형 컨버터 최적설계 (Optimal Design of the LLC HB Resonant Converter for Notebook Computer Adapter)

  • 유병선;김창선
    • 전기학회논문지
    • /
    • 제56권8호
    • /
    • pp.1418-1423
    • /
    • 2007
  • The topology of LLC half bridge resonant converter provides ZVS characteristic. The voltage stress and current stress are smaller than that of the general resonant converters. So the LLC HB resonant converter can be considered as a optimal circuit for the notebook computer adapter. In the adapter design, we should consider the weight, the size and the overheat of the adapter. Thus the higher efficiency is an essential particular. First of all, the optimal design of transformer is the most important facts. Some parameters should be considered in order to get the highest efficiency. The adapter is designed through the considering of these parameters including the PFC circuit as the pre-regulator. It converts AC line input into about DC 390V link voltage of the LLC HB converter input and the converter has 16V/90W ratings. The efficiency measured is about up to 93%.

LLC 공진형 하프브리지 DC-DC 컨버터용 동기정류기의 특성 개선에 관한 연구 (A Study on the characteristics improvement of LLC resonant half-bridge DC-DC converter with synchronous rectifier)

  • 이광택;이달우;안태영;김성철;장찬규;김용주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.178-181
    • /
    • 2005
  • This paper presents a synchronous rectifier in a LLC half bridge topology. The proposed synchronous rectifier is used to a current driven synchronous rectifier(SR). If FET is driven without dead times. Voltage driven synchronous rectifier may introduce voltage and current surge during the zero dead times. To solve this problem, we propose to use modified current driven synchronous rectifier. Finally, the prototype is built and comparison on the current and voltage driven synchronous rectifier(SR).

  • PDF

Asymmetrical 반브리지 컨버터의 이차측 다이오드 전압스트레스저감을 위한 새로운 하이브리드 제어기법 (A new hybrid control scheme for reduction of secondary diode voltage stresses Based on interleaved PFC Asymmetrical Half Bridge Topology)

  • 박남주;이동윤;현동석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1416-1418
    • /
    • 2005
  • This paper presents a new hybrid control method of asymmetrical half-bridge converter(AHBC) with low voltage stresses of the diodes and interleaved PFC(power factor correction). The proposed new control scheme can observe variation of secondary diodes voltage stresses by variation of duty ratio and then decide the control portions which are asymmetrical control and PFM(Pulse Frequency Modulation). Therefore, the proposed control scheme has many advantages such as a low rated voltage of the secondary diodes, low conduction loss according to the low voltage drop and wide zvs range by load variation. Through simulation results, the validity of the proposed control scheme is demonstrated.

  • PDF

Input Voltage Range Extension Method for Half-Bridge LLC Converters by Using Magamp Auxiliary Post-Regulator

  • Jin, Xiaoguang;Lin, Huipin;Xu, Jun;Lu, Zhengyu
    • Journal of Power Electronics
    • /
    • 제19권1호
    • /
    • pp.34-43
    • /
    • 2019
  • An improved half-bridge LLC converter with a magamp auxiliary post-regulator is proposed in this paper. The function of the magamp is bypassed when the converter works within the low input-voltage range. Meanwhile, it operates as an auxiliary post-regulator when the input voltage is high. By changing the blocking time of the magamp, the dc gain of the converter can be extended. Hence, the input voltage range of the converter is extended. The realization of proposed topology does not require a complicated circuit. The controller of the magamp can be easily implemented using only passive components, transistors and an OP amp. The generalized operational principle is analyzed and the design criterion for the magamp is presented. Finally, a 25V output, 400W experimental prototype was built and tested for a 160-300V input-voltage range to verify the feasibility of the proposed method.

Protection of the MMCs of HVDC Transmission Systems against DC Short-Circuit Faults

  • Nguyen, Thanh Hai;Lee, Dong-Choon
    • Journal of Power Electronics
    • /
    • 제17권1호
    • /
    • pp.242-252
    • /
    • 2017
  • This paper deals with the blocking of DC-fault current during DC cable short-circuit conditions in HVDC (High-Voltage DC) transmission systems utilizing Modular Multilevel Converters (MMCs), where a new SubModule (SM) topology circuit for the MMC is proposed. In this SM circuit, an additional Insulated-Gate Bipolar Translator (IGBT) is required to be connected at the output terminal of a conventional SM with a half-bridge structure, hereafter referred to as HBSM, where the anti-parallel diodes of additional IGBTs are used to block current from the grid to the DC-link side. Compared with the existing MMCs based on full-bridge (FB) SMs, the hybrid topologies of HBSM and FBSM, and the clamp-double SMs, the proposed topology offers a lower cost and lower power loss while the fault current blocking capability in the DC short-circuit conditions is still provided. The effectiveness of the proposed topology has been validated by simulation results obtained from a 300-kV 300-MW HVDC transmission system and experimental results from a down-scaled HVDC system in the laboratory.

A Study on a Single-Phase Module UPS using a Three-Arm Converter/Inverter

  • Koo, Tae-Geun;Byun, Young-Bok;Joe, Ki-Yeon;Kim, Dong-Hee;Kim, Chul-U
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제3B권1호
    • /
    • pp.44-51
    • /
    • 2003
  • The module UPS can flexibly implement expansion of power system capacities. Further-more, it can be used to build up the parallel redundant system to improve the reliability of power system operation. To realize the module UPS, load sharing without interconnection among parallel connecting modules as well as a small scale and lightweight topology is necessary. In this paper, the three-arm converter/inverter is compared with the general full-bridge and half-bridge topology from a practical point of view and chosen as the module UPS topology. The switching control approaches based on a pulse width modulation of the converter and inverter of the system are presented independently. The frequency and voltage droop method is applied to parallel operation control to achieve load sharing. Two prototype 3㎸A modules are designed and implemented to confirm the effectiveness of the pro-posed approaches. Experimental results show that the three-arm UPS system has a high power factor, a low distortion of output voltage and input current, and good load sharing characteristics.

Full-bridge 방식의 절연형 DC/DC 컨버터 (Isolated DC/DC Converter Using Full-Bridge Topology)

  • 허민호;박성준;김광헌;송성근;김종권
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.987_988
    • /
    • 2009
  • 견인용 시스템에 있어서 구동모터의 효율증대를 위해서는 고압전원이 필수적이며 이를 위해 일반적으로 승압 DC/DC 컨버터 사용하고 있으나, Hard Switching 방식의 PWM 컨버터로는 효율향상에 한계가 있으며 동특성이 저하되는 단점이 있다. 본 논문에서는 새로운 방식의 절연된 차량용 고압 DC/DC 컨버터를 이용하여 효율 및 동특성을 개선하기위해 Full-bridge 컨버터와 Double-half-bridge 컨버터를 이용한 소프트 스위칭방식으로 고효율화를 달성하고 컨버터의 동특성을 향상시켰다.

  • PDF

전기자동차용 1MHz LDC에 적합한 새로운 2단계 전력변환기 (A Novel Two-Stage Power Converter suitable for 1MHz-LDC of Electric Vehicles.)

  • Tuan, Tran Manh;Choi, Woojin
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2018년도 추계학술대회
    • /
    • pp.51-53
    • /
    • 2018
  • The Low Voltage DC-DC converters (LDCs) of the Electric Vehicles require high power density and high efficiency operation over the wide range of load and input voltage variations. This paper introduces a novel topology which combines three 1 MHz Half-Bridge (HB) LLC resonant converters and an Inverting Buck-Boost (IBB) converter to adjust the output voltage without frequency modulation. The switching frequency of the proposed converter is fixed at 1MHz to achieve a constant frequency operation for the resonant converter. In the proposed topology GaN FETs and planar transformers are employed to optimize the converter operation at high frequency. A 1 MHz/1.8 kW prototype converter is built to verify the feasibility and the validity of the proposed LDC topology.

  • PDF

A Fault Tolerant Structure and Control Strategy for Electromagnetic Stirring Supplies

  • Li, Yan;Luo, An;Xiang, Xinxing;Chen, Yandong;He, Zhixing;Zhou, Fayun;Chen, Zhiyong
    • Journal of Power Electronics
    • /
    • 제17권5호
    • /
    • pp.1256-1267
    • /
    • 2017
  • A fault tolerant structure and its corresponding control strategy for electromagnetic stirring power supplies are proposed in this paper. The topology structure of the electromagnetic stirring power supply contains two-stages. The fore-stage is the PWM rectifier. The back-stage is the fault tolerant inverter, which is a two-phase three-bridge orthogonal inverter circuit while operating normally. When the power switch devices in the inverter are faulty, the structure of the inverter is reconfigured. The two-phase half bridge inverter circuit is constructed with the remaining power switch devices and DC-link capacitors to keep the system operating after cutting the faulty power switch devices from the system. The corresponding control strategy is proposed to let the system work under both normal and fault conditions. The reliability of the system is improved and the requirement of the electromagnetic stirring process is met. Finally, simulation and experimental results verify the feasibility of the proposed fault tolerant structure and corresponding control strategy.