• 제목/요약/키워드: Half Value Layer

검색결과 138건 처리시간 0.029초

진단용(診斷用) X선(線)의 반가층(半價層)에 관(關)한 연구(硏究) (A Study on Measurement of the Half Value Layer in Diagnostic X-ray)

  • 고신관
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제7권1호
    • /
    • pp.53-66
    • /
    • 1984
  • The quality of continuous x-ray beam depends upon the half value layer which varies according to the geometric conditions, the filtration thickness, and the amount of accelerated voltage (KVP). Experiments were conducted on the amount of electric energy that was changed to x-ray energy, and on the relationship between KVp and the intensity of x-rays. The results were as follows: 1. The amount of x-rays were not equal under the condition of the same exposure factor. 2. The intensity of x-rays was attenuated by an exponential function the geometric conditions were "good" and it was not when they were "poor". 3. The thicker the total filtration substance was and the higher the KVp was, the bigger the amount of x-ray energy was. 4. The homogeneity of medium energy x-ray was the best, when the total filtration substance was 3.9mm A1. 5. The mean energy of continuous x-ray was about 45% of KVp.

  • PDF

진단용(診斷用) X-선장치(線裝置)의 선질(線質) 특성(特性)에 관(關)한 연구(硏究) (A Study on Radiation Quality of the Diagnostic X-ray Equipments)

  • 박명환;이준일
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제20권1호
    • /
    • pp.55-59
    • /
    • 1997
  • The quality of continuous X-ray beam depends upon the half value layer which varies according to the geometric conditions, filtration thickness, and tube voltage. We compared the inverter type X-ray equipment with the conventional single phase 2 peak and the three phase 12 peak for the quality obtained by changes of the added filter thickness and the tube voltage. The quality of single phase 2 peak X-ray generator showed increase for the added filter and the tube volt-age. The half value layer is Increased the thicker the filter and the higher the kVp. The quality of the Inverter type and the three phase 12 peak in comparison with the single phase 2 peak X-ray generator is increased.

  • PDF

Radiation shielding properties of weathered soils: Influence of the chemical composition and granulometric fractions

  • Pires, Luiz F.
    • Nuclear Engineering and Technology
    • /
    • 제54권9호
    • /
    • pp.3470-3477
    • /
    • 2022
  • Soils are porous materials with high shielding capability to attenuate gamma and X-rays. The disposal of radionuclides throughout the soil profile can expose the living organisms to ionizing radiation. Thus, studies aiming to analyze the shielding properties of the soils are of particular interest for radiation shielding. Investigations on evaluating the shielding capabilities of highly weathered soils are still scarce, meaning that additional research is necessary to check their efficiency to attenuate radiation. In this study, the radiation shielding properties of contrasting soils were evaluated. The radiation interaction parameters assessed were attenuation coefficients, mean free path, and half- and tenth-value layers. At low photon energies, the photoelectric absorption contribution to the attenuation coefficient predominated, while at intermediate and high photon energies, the incoherent scattering and pair production were the dominant effects. Soils with the highest densities presented the best shielding properties, regardless of their chemical compositions. Increases in the attenuation coefficient and decreases in shielding parameters of the soils were associated with increases in clay, Fe2O3, Al2O3, and TiO2 amounts. In addition, this paper provides a comprehensive description of the shielding properties of weathered soils showing the importance of their granulometric fractions and oxides to the attenuation of the radiation.

MCNP 시뮬레이션을 통한 450 kVp 엑스레이 튜브의 콘크리트 차폐벽 두께 계산 및 반가층 방법을 이용한 계산과의 결과 비교 (Calculation of Concrete Shielding Wall Thickness for 450 kVp X-ray Tube with MCNP Simulation and Result Comparison with Half Value Layer Method Calculation)

  • 이상헌;허삼석;이은중;김찬규;조규성
    • 방사선산업학회지
    • /
    • 제10권1호
    • /
    • pp.29-35
    • /
    • 2016
  • Radiation generating devices must be properly shielded for their safe application. Although institutes such as US National Bureau of Standards and National Council on Radiation Protection and Measurements (NCRP) have provided guidelines for shielding X-ray tube of various purposes, industry people tend to rely on 'Half Value Layer (HVL) method' which requires relatively simple calculation compared to the case of those guidelines. The method is based on the fact that the intensity, dose, and air kerma of narrow beam incident on shielding wall decreases by about half as the beam penetrates the HVL thickness of the wall. One can adjust shielding wall thickness to satisfy outside wall dose or air kerma requirements with this calculation. However, this may not always be the case because 1) The strict definition of HVL deals with only Intensity, 2) The situation is different when the beam is not 'narrow'; the beam quality inside the wall is distorted and related changes on outside wall dose or air kerma such as buildup effect occurs. Therefore, sometimes more careful research should be done in order to verify the effect of shielding specific radiation generating device. High energy X-ray tubes which is operated at the voltage above 400 kV that are used for 'heavy' nondestructive inspection is an example. People have less experience in running and shielding such device than in the case of widely-used low energy X-ray tubes operated at the voltage below 300 kV. In this study, Air Kerma value per week, outside concrete shielding wall of various thickness surrounding 450 kVp X-ray tube were calculated using MCNP simulation with the aid of Geometry Splitting method which is a famous Variance Reduction technique. The comparison between simulated result, HVL method result, and NCRP Report 147 safety goal $0.02mGy\;wk^{-1}$ on Air Kerma for the place where the public are free to pass showed that concrete wall of thickness 80 cm is needed to achieve the safety goal. Essentially same result was obtained from the application of HVL method except that it suggest the need of additional 5 cm concrete wall thickness. Therefore, employing the result from HVL method calculation as an conservative upper limit of concrete shielding wall thickness was found to be useful; It would be easy, economic, and reasonable way to set shielding wall thickness.

A penny-shaped interfacial crack between piezoelectric layer and elastic half-space

  • Ren, J.H.;Li, Y.S.;Wang, W.
    • Structural Engineering and Mechanics
    • /
    • 제52권1호
    • /
    • pp.1-17
    • /
    • 2014
  • An interfacial penny-shaped crack between piezoelectric layer and elastic half-space subjected to mechanical and electric loads is investigated. Using Hankel transform technique, the mixed boundary value problem is reduced to a system of singular integral equations. The integral equations are further reduced to a system of algebraic equations with the aid of Jacobi polynomials. The stress intensity factor and energy release rate are determined. Numerical results reveal the effects of electric loadings and material parameters of composite on crack propagation and growth. The results seem useful for design of the piezoelectric composite structures and devices of high performance.

광자극형광나노닷선량계를 사용한 X선 빔의 유효에너지 결정 (Determination of the Effective Energy of X-Ray Beam Using Optically Stimulated Luminescent nanoDot Dosimeters)

  • 김종언;이상훈
    • 한국방사선학회논문지
    • /
    • 제9권6호
    • /
    • pp.375-379
    • /
    • 2015
  • 이 연구의 목적은 다종에너지 X선 빔의 유효에너지를 결정하는데 있다. 80 kVp X선 빔에 대한 알루미늄의 반가층은 광자극형광나노닷선량계들(OSLnDs)을 사용하여 측정하였다. 선감쇠계수(${\mu}$)는 측정된 반가층을 사용하여 계산하였다. 그리고 질량감쇠계수(${\mu}/{\rho}$)는 알루미늄의 밀도로 선감쇠계수를 나누어 얻었다. 얻어진 질량감쇠계수의 유효에너지($E_{eff}$)는 미국표준기술연구소(NIST)에서 주어진 알루미늄의 광자에너지들에 대한 X선질량감쇠계수들의 자료를 사용하여 결정하였다. 결과로서, 반가층, 선감쇠계수 및 질량감쇠계수는 각각 2.262 mmAl, $3.06cm^{-1}$, $1.114cm^2/g$이다. 그리고 유효에너지는 29.79 keV에서 결정되었다.

폐 브라운관(CRT) 유리의 잔골재 대체가 모르타르 시험체의 감마선 차폐에 미치는 영향 (Effect of Replacing Fine Aggregate by Cathode-Ray Tube(CRT) Waste Glass on Gamma-ray Shielding Properties of Cement Mortar Specimen)

  • 최윤석;이선민;김태상;김일순;양은익
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제23권7호
    • /
    • pp.172-180
    • /
    • 2019
  • 이 연구에서는 CRT 폐유리의 잔골재 대체율과 재료 물성(조성)을 달리한 모르타르의 미세구조와 감마선 차폐 효율을 평가하였다. 실험 결과에 따르면 CRT 폐유리의 잔골재 대체율이 증가할수록 50nm 크기 이하와 400nm 크기 이상의 공극 볼륨이 증가하였으며, 선헝감쇠계수는 상승하고 반가층은 작아지는 결과를 나타냈다. 또한, CRT 폐유리의 대체했을 때 강도는 감소하였으나 혼화재를 치환하여 OPC 이상의 강도값을 확보할 수 있었다.

Experimental Investigation of Clay Fly Ash Bricks for Gamma-Ray Shielding

  • Mann, Harjinder Singh;Brar, Gurdarshan Singh;Mann, Kulwinder Singh;Mudahar, Gurmel Singh
    • Nuclear Engineering and Technology
    • /
    • 제48권5호
    • /
    • pp.1230-1236
    • /
    • 2016
  • This study aims to determine the effect of fly ash with a high replacing ratio of clay on the radiation shielding properties of bricks. Some interaction parameters (mass attenuation coefficients, half value layer, effective atomic number, effective electron density, and absorption efficiency) of clay fly ash bricks were measured with a NaI(Tl) detector at 661.6 keV, 1,173.2 keV, and 1,332.5 keV. For the investigation of their shielding behavior, fly ash bricks were molded using an admixture to clay. A narrow beam transmission geometry condition was used for the measurements. The measured values of these parameters were found in good agreement with the theoretical calculations. The elemental compositions of the clay fly ash bricks were analyzed by using an energy dispersive X-ray fluorescence spectrometer. At selected energies the values of the effective atomic numbers and effective electron densities showed a very modest variation with the composition of the fly ash. This seems to be due to the similarity of their elemental compositions. The obtained results were also compared with concrete, in order to study the effect of fly ash content on the radiation shielding properties of clay fly ash bricks. The clay fly ash bricks showed good shielding properties for moderate energy gamma rays. Therefore, these bricks are feasible and eco-friendly compared with traditional clay bricks used for construction.

단층 래티스 돔의 기하학적 비선형 좌굴하중 추정에 관한 연구 (A Study on the Presumption of Geometrically Nonlinear Buckling Load of the Single Layer Layer Latticed Dome)

  • 이정현;최일섭;이상주;한상을
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.12-19
    • /
    • 2005
  • The single layer latticed dome is very sensitive on the slenderness ratio and half open angle of the elements, load condition and the connection type because it is organized by a lot of thin elements, so we have to use the geometrically nonlinear buckling load when the buckling behavior of the structures is analyzed But, it is very difficult to design the single layer latticed domes considered all conditions. Therefore the purpose of this paper is to propose the appropriate design method of the single layer latticed dome considered the geometrically nonlinear buckling load in base on the linear buckling load by the eigen-value analysis.

  • PDF

Influence of polled direction on the stress distribution in piezoelectric materials

  • Ilhan, Nihat;Koc, Nagihan
    • Structural Engineering and Mechanics
    • /
    • 제54권5호
    • /
    • pp.955-971
    • /
    • 2015
  • In this paper, the influence of the polled direction of piezoelectric materials on the stress distribution is studied under time-harmonic dynamical load (time-harmonic Lamb's problem). The system considered in this study consists of piezoelectric covering layer and piezoelectric half-plane, and the harmonic dynamical load acts on the free face of the covering layer. The investigations are carried out by utilizing the exact equations of motion and relations of the linear theory of electro-elasticity. The plane-strain state is considered. It is assumed that the perfect contact conditions between the covering layer and half-plane are satisfied. The boundary value problems under consideration are solved by employing Fourier exponential transformation techniques with respect to coordinates directed along the interface line. Numerical results on the influence of the polled direction of the piezoelectric materials such as PZT-5A, PZT-5H, PZT-4 and PZT-7A on the normal stresses, shear stresses and electric potential acting on the interface plane are presented and discussed. As a result of the analyses, it is established that the polled directions of the piezoelectric materials play an important role on the values of the studied stresses and electric potential.