A Study on HVDC and BESS Application for High Penetration of Renewable Energy Sources (제주지역 재생에너지 수용을 위한 HVDC 및 BESS 활용에 관한 연구)

  • Kwak, Eun-Sup;Min, Jae-Hyun;Jung, Ho-Chul;Moon, Chae-Joo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.6
    • /
    • pp.1339-1348
    • /
    • 2021
  • There are variety of reasons for renewable energy curtailment, including lack of transmission availability and grid system stability. In the Jeju island region, there are many cases in which the supply of electricity is already increased compared to the demand for electricity due to the increase of solar and wind power generation facilities, and accordingly, the number of curtailments for wind power generation is increasing. This research aims to find the direction of efficient reception of renewable energy and stable operation of the power system using HVDC(High Voltage Direct Current) and BESS(Battery Energy Storage System) facilities that are in charge of power supply in Jeju island. And the paper suggests a practical operation plan for optimal system operation, and the direction of system operation of the land power system due to the expansion of solar and wind power generation facilities in the future.

Study on the effect of DC voltage in oil-immersed transformer insulation system (DC 전압이 유입변압기 절연시스템에 미치는 영향에 관한 연구)

  • Jang, Hyo-Jae;Kim, Yong-Han;Seok, Bok-Yeol
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1552-1553
    • /
    • 2011
  • The HVDC transformer which is one of the main equipments for HVDC(High Voltage Direct Current) electric power transmission systems is exposed to not only AC voltage but also the inflowing DC voltage which comes from the DC-AC converter systems. Therefore, the HVDC transformer insulation system is required to withstand the electric field stress under AC, DC and DC polarity reversal conditions. However the electric field distributions under those conditions are different because the AC electric field and DC electric field are governed by permittivity and conductivity, respectively. In this study, the changes of electric potential and electric field of conventional AC transformer insulation system under DC polarity reversal test condition were analyzed by FEM(Finite Element Method). The DC electric field stress was concentrated in the solid insulators while the AC electric field stress was concentrated in the mineral oil. In addition, the electric stress under that condition which is affected by the surface charge accumulation at the interfaces between insulators was evaluated. The stress in some parts could be higher than that of AC and DC condition, during polarity reversal test. The result of this study would be helpful for the HVDC transformer insulation system design.

  • PDF

A Study on Control Characteristic and Application of Optimal Modulation Controller for HVDC Transmission System (초고압 직류 송전 시스템에 대한 최적 변조 제어기의 적용 및 제어 특성에 관한 연구)

  • Lee, J.M.;Hur, D.R.;Chung, D.I.;Chung, H.H.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1318-1320
    • /
    • 1999
  • Recently, according to the growth of national economy and the improvement of lining conditions, electric power demand is increasing gradually. So it is being examined to construct large thermal power plants or nuclear plants. For the effective use of lands and for the economy of generations sites, the distance between generation and demand locations becomes farther and farther. At the same time, people desire higher quality or electric power. So in this paper, the optimal modulation controller for HVDC transmission system are designed by a recursive algorithm that determines the state weighting matrix Q of a linear quadratic performance. It means that the application of optimal modulation controller in HVDC transmission system can contribute the propriety to the improvement of the stability in HVDC transmission system.

  • PDF

A study on BTB HVDC location in metropolitan area considering fault current analysis (고장전류를 고려한 수도권 BTB HVDC 위치선정 연구)

  • Yoon, Min-Han;Jang, Gil-Soo;Park, Jung-Soo;Jang, Byung-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.274-275
    • /
    • 2011
  • Fault current problems is considered a serious issue in the power system because large fault currents not only cause many side effects to the equipments of power system but also lead to severe problems, such as blackouts. This paper deals with the structural analysis and 3-phase fault current stability of the future Seoul metropolitan power system. The simulation composition and analysis are performed with the 4th KEPCO power supply planning data using PSS/e. Through the results of the simulations, it can be observed that the future Seoul metropolitan system results in a fault current which exceeds the circuit breaker (CB) rate. This unremovable fault current can cause critical damage to power system. To resolve the problem, the algorithm for the application of Voltage Sourced Converter Back-to-Back High Voltage Direct Current (VSC BTB HVDC) is being proposed. where the most suitable location for solving fault current problem in Seoul metropolitan area is being implemented.

  • PDF

Design of Digital Controller considering Time Delay in the MMC-HVDC system (MMC-HVDC 시스템에서 시간 지연을 고려한 디지털 제어기의 설계)

  • Song, Ji-Wan;Ku, Nam-Jun;Kim, Rae-Young
    • Proceedings of the KIPE Conference
    • /
    • 2013.11a
    • /
    • pp.87-88
    • /
    • 2013
  • 본 논문에서는 모듈형 멀티레벨 컨버터(Modular Multi-level Converter, MMC)의 제어기를 설계에 있어 시간 지연을 고려한 디지털 제어기 설계 방법을 제시한다. 제안된 방법으로 설계한 디지털 제어기를 사용하면 시간 지연으로 인한 시스템의 성능저하를 완화할 수 있으며, 11-Level로 구현된 MMC HVDC 시스템 모델에 적합한 디지털 제어기의 설계 방법에 관해 기술하고 제안한 방법의 타당성을 아날로그 제어기와의 성능비교를 Psim를 통해 검증하였다.

  • PDF

The study for implementation of HVDC Control and Protection system using realtime JAVA. (실시간 자바를 이용한 HVDC Control and Protection 시스템 구현에 관한 고찰)

  • Sua, M.W.
    • Proceedings of the KIPE Conference
    • /
    • 2014.11a
    • /
    • pp.125-126
    • /
    • 2014
  • 본 논문에서는 실시간 자바를 사용하여 초고압 송전 설비의 제어 및 보호 장치의 구현에 대해 고찰 하고자 한다. 초고압 송전 설비는 대단위 시스템이라서 객체 지향 프로그래밍이 유리하지만, 실시간 운영체제 상에서 고속으로 실시간 동작을 해야 하므로 객체지향 프로그래밍이 모순 된다 할 수 있다. 실시간 자바를 통해서 대형 HVDC 시스템에서 객체 지향 설계의 유연함과 고속 실시간 시스템을 구현 할 수 있는 장점을 동시에 가질 수 있는 방법에 대해 고찰 해 보자.

  • PDF

Control Hierarchy Analysis of Haenam-Cheju HVDC system (해남-제주 HVDC 계통의 제어 계층 구조 분석)

  • Kwak, Joo-Sik
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1327-1330
    • /
    • 1999
  • In this paper control hierarchy of Haenam-Cheju HVDC link are analyzed and their functional specifications are summarized related to their level. The control functions for the submarine DC transmission are implemented by software programs on 16-bit parallel processor-based machines which are composed of subunits hierarchically linked each other

  • PDF

The Control Characteristics of Haenam-Cheju HVDC system at Ground Fault and Steady State (해남-전주 HVDC 계통의 정상상태 및 지락 고장시 제어특성)

  • Kwak, J.S.;Woo, J.W.;Shim, E.B.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1331-1333
    • /
    • 1999
  • In Haenam-Cheju HVDC link several modes of operations and controls are provided, which are constant frequency control, constant power control and constant current control. This paper describes basic control action of converters under three control modes and shows EMTDC simulation results at ground fault and steady state respectively.

  • PDF

Power Quality Analysis of Jeju System Due To Interconnecting Hangyung Wind Farm #2 (한경풍력 2단계 연계에 따른 제주계통의 전력품질 분석)

  • Chae, Woo-Kyu
    • Proceedings of the KIEE Conference
    • /
    • 2008.10c
    • /
    • pp.170-173
    • /
    • 2008
  • 제주의 전력계통은 HVDC로 육지계통과 연계되어 있으며 3곳의 풍력발전단지가 연계되어 있다. 향후 대규모의 풍력발전이 연계된 상황에서 HVDC Overhaul을 시행하거나 어떤 사고로 HVDC가 끊어진다면 제주계통을 정상적으로 유지하는 것이 어려울 수도 있다. 이에 본 본문은 Overhaul 기간에 한경풍력 2단계가 제주계통의 전력품질에 어떤 영향을 미치는지 분석하였다. Overhaul 기간에는 제주계통의 주파수가 매우 불안정하여 풍력발전량의 급격한 변동에 의하여 제주계통 전체의 주파수가 영향을 받는 것을 확인할 수 있었다.

  • PDF

A New Synthetic Test Circuit for Testing Thyristor Valve in HVDC Converter (HVDC 컨버터의 Thyristor Valve 시험을 위한 새로운 합성시험회로)

  • Kim, Kyeong-Tae;Lee, Yoon-Seok;Han, Byung-Moon
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.236-237
    • /
    • 2012
  • 본 연구에서는 Thyristor로 구성되는 HVDC System의 Thyristor밸브를 시험하기위한 새로운 합성시험회로를 제안하고 그 성능과 동작을 분석한 내용에 대해 기술하고 있다. 제안하는 시스템의 동작 타당성을 체계적으로 분석하기 위해 PSCAD/EMTDC 소프트웨어를 이용한 시뮬레이션 모델을 개발하였으며 이를 기반으로 하드웨어 시스템을 제작하여 제안하는 시스템의 동작특성을 분석하였다.

  • PDF