• 제목/요약/키워드: HVAC Blower

검색결과 15건 처리시간 0.024초

상업용 코드를 이용한 차량용 HVAC module의 유동에 관한 전산모사 (The Numerical Simulation of Fluid Flow in an Automotive HVAC module by using Commercial Code)

  • 김학범;홍성림;정덕수
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2003년도 추계 학술대회논문집
    • /
    • pp.194-199
    • /
    • 2003
  • The studying is to analyze characteristic of air flow and is used to design in an automotive HVAC module. The RNG k-e turbulence model with the Upwind Difference convection scheme and an unstructured hybrid mesh with arbitrary matching method were applied to the simulation. The comparing air flow characteristic of the basic HVAC module and total HVAC module with blower were discussed in the paper.

  • PDF

차량용 공조덕트의 소음특성에 관한 연구 (Characteristics of noise in HVAC duct for vehicle)

  • 김재원;김진민;박정영
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2003년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.529-534
    • /
    • 2003
  • Comprehensive study on the system, including blower and ducts, of HVAC device of a vehicle has been carried out for improvements of noise characteristics. The parameters of design improvements are concerned with geometric informations such as the shape of ducts and presence of a windshield window. Test results show that noise level increasing the following order: HV (HD) < V (D) < BH ${\sim}$ BHV (BHD) < B (B, H, V, D denote for blower, heater unit, vent duct, defrost duct, respectively). The effects of windshield glass on the noise level in the case of defrost mode are pronounced and the effects of the geometry of ducts on the overall HVAC noise prove to be not small.

  • PDF

다차원 해석법을 이용한 자동차 공조시스템의 기여도분석 (Coherent Analysis of vehicle HVAC Using the MDSA Method)

  • 오재응;황동건;아미누딘;이정윤;김성수
    • 한국정밀공학회지
    • /
    • 제22권8호
    • /
    • pp.143-150
    • /
    • 2005
  • To verify applicability of multi-dimensional spectral analysis (MDSA) fur noise source identification two different approaches which are frequency response and coherent function have been investigated. The coherence function approach appears able to separate the correlated system when the noise sources were coherent. In this study, we identify contribution of structure-borne-noise of vehicle HVAC system using MDSA method. Firstly, to identify the applicability of MDSA method, 4-inputs of vehicle HVAC system were the signals measured by accelerometers attached on the selected noise sources which were composed of blower, evaporator, heater and duct. While 1-output which was driver's position sound was the SPL signals measured by a remote microphone, when the blower motor was operating. We identify efficiency of systems modeled with four Inputs/single output through ordinary coherence function (OCF) and partial coherence function (PCF). As a result of experiment, the blower accounted for $62-88\%$ of the overall level of sound energy density. Also, according to the analysis of acoustic signal and vibration signals measurement, an investigation of the noise source identification in the vehicle HVAC is presented. With the sound intensity method, the major sources of the vehicle HVAC radiation are verified. Also the method of improving the noise reduction is proposed by attaching damping patch access to blower motor and noise reduction is verified.

한국형 고속전철 공조시스템 소음에 관한 연구 (Noise Characteristics of the HVAC System of Korea High Speed Train)

  • 하인수;박철희;이우식;한기흥
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 1998년도 추계학술대회 논문집
    • /
    • pp.379-387
    • /
    • 1998
  • HVAC systems are used to maintain comfort conditions in occupied spaces. Like rolling noise and aerodynamic noise, noise from the HVAC system of train increases interior noise level. For an appropriate interior noise level, it is necessary not to find noise sources and their propagation paths. Noise emission from the sources and propagation through the propagation paths should be regulated in order to reduce their effect to the interior noise level. In general, the main noise source in the HVAC system is blower which operates at high static pressure. This noise propagates through ducts which are directly connected to the residential area. Since the blower noise can be reduced only to some degree, it is necessary for the propagation paths to have enough noise attenuation. Acoustic properties of ducts are usually found by experimental methods but it is rather difficult and expensive to set up such test equipments. In this thesis, the design and the noise characteristics of TGV-K HVAC system are studied. Finite element method in accordance with experimental method is used to study the acoustic properties of TGV-K duct system.

  • PDF

자동차 HVAC용 Blower Unit 내부 유동장의 PIV 계측 (PIV Measurement of Flow Inside of HVAC Blower Unit)

  • 지호성;김보람;이상준
    • 한국자동차공학회논문집
    • /
    • 제15권5호
    • /
    • pp.165-173
    • /
    • 2007
  • Flow characteristics inside a blower unit of an automotive HVAC module were investigated experimentally using a high-resolution PIV technique. The PIV system consists of a 2-head Nd:YAG laser, a high-resolution CCD camera, optics and a synchronizer. The prototype siroco-fan with forward-curved blades was operated under the same condition of real car. The scroll casing was made transparently for capturing clear flow images. The time-averaged velocity fields were measured in three cross sections. Flow is accelerated with going toward the outer wall of scroll due to centrifugal force and large pressure gradient formed in the region between the fan and the outer casing wall. The presence of the cut-off region and diffusing duct of fan outlet influences largely the flow structure inside the blower unit.

자동차 송풍장치(Blower)용 HVAC Double Cylinder Motor 설계에 관한 연구 (A Study on the Design of HVAC Double Cylinder Motor for a Car Blower)

  • 이현장;송삼삼;박창순
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 춘계학술대회 논문집 에너지변화시스템부문
    • /
    • pp.91-93
    • /
    • 2009
  • In the recent years, electrical Motors have been developed for a car Blower. Their requirement are high efficiency, low cogging torque and long life. In this paper, the Double Cylinder Motor for a Car Blower was designed which is high efficiency, low noise and vibration because of slotless and double cylinder structure.

  • PDF

다차원 스펙트럼 해석법을 이용한 자동차 공조시스템의 기여도분석 (Coherent Analysis of HVAC Using the Multi-Dimensional Spectral Analysis)

  • 황동건;오재응;이정윤;김성수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.999-1004
    • /
    • 2004
  • In this study, we identify contribution of structure-borne-noise of vehicle HVAC system using Multi-Dimensional spectral analysis (MDSA) method. Firstly, to identify the applicability of MDSA method, the case of HVAC system was modeled with four input / single output system. The four inputs which is given vibration data is composed of blower, evaporator, heater and duct. The single output is noise data from driver's seat. When the blower motor is operating, we analyze the contributions of four input / single output. As a result of experiment, we identify efficiency of systems modeled with four input / single output through ordinary coherence function (OCF) and multiple coherence function (MCF).

  • PDF

UPS 기능을 갖는 A/C Blower용 인버터 시스템 개발 (Development of the Inverter System with UPS Function for the Air-Conditioning Blower)

  • 임승범;이윤하;목형수;지준근
    • 전력전자학회논문지
    • /
    • 제16권3호
    • /
    • pp.302-308
    • /
    • 2011
  • 현재 철도 차량용 공조 시스템은 3상 AC 380V를 입력으로 받아 온/오프 제어만 하고 있어 효율 저감 및 소음 등의 문제점을 가지고 있으며 AC 전원 공급이 차단될 경우 blower 동작이 멈추는 문제점을 가지고 있다. 본 논문에서는 UPS 기능을 갖는 A/C blower용 인버터 시스템을 제안한다. 제안한 인버터 시스템은 입력으로 AC 전원과 DC 전원을 받아서 blower 구동용 유도전동기의 V/F 제어를 하며, CAN통신을 이용하여 속도, 모드 및 Soft-Start 시간 등을 제어한다. 또한 CAN 통신 고장시에는 정비용으로 RS-232통신을 이용해서도 제어할 수 있고 조작자가 직접 하드웨어적으로 제어할 수도 있어 기존의 문제점을 보완할 수 있다. 시뮬레이션과 실험을 통해 제안한 인버터 시스템의 유용성을 입증한다.

Experimental Study on the Mean Flow Characteristics of Forward-Curved Centrifugal Fans

  • Kwon, Eui-Yong;Cho, Nam-Hyo
    • Journal of Mechanical Science and Technology
    • /
    • 제15권12호
    • /
    • pp.1728-1738
    • /
    • 2001
  • Measurements have been made in an automotive HVAC b1ower for two different centrifugal fans. This work is directed at improving the performance of a conventional forward-curved centrifugal fan for a given small blower casing. Mean velocities and pressure have been measured using a miniature five-hole probe and a pressure scanning unit connected to an online data acquisition system. First, we obtained the fan performance versus flow rates showing a significant attenuation of unstable nature achieved with the new fan rotor in the surging operation range. Second, aerodynamic characterizations were carried out by investigating the velocity and pressure fields in the casing flow passage for different fan operating conditions. The measurements stowed that performance coefficients are strongly influenced by flow characteristics at the throat region. The main flow features ware common in both fans, but improved performance is achieved with tole new fan rotor, particularly in lower flow rate legions. Based on the measured results, design improvements were carried out in an acceptable operation range, which gave considerable insight into what features of flow behavior ware most important.

  • PDF

에어컨팬용 3상 SRM(200와트급) (Three phase Switched Reluctance Motor for 200W rated air conditioner blower)

  • 임준영;김상영;최용원
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2004년도 전력전자학술대회 논문집(1)
    • /
    • pp.259-259
    • /
    • 2004
  • To date, induction motors have mainly been used for heating, ventilation, and air conditioning (HVAC) applications, however, there is significant research being done world-wide on the use of switched reluctance motor(SRM) in household home appliances. This papers proposes three phase SRM for the air-conditioner blower that has cost merit and good performance respectively compared with conventional induction motor.

  • PDF