• 제목/요약/키워드: HVAC 시스템평가

검색결과 45건 처리시간 0.032초

CAM 곡선 개선에 의한 차량용 공조기의 소음 저감 평가 (Evaluation for Noise Reduction of the HVAC by Modification of CAM Curve)

  • 정재은;정창용;서범준;정운창;오재응
    • 한국소음진동공학회논문집
    • /
    • 제21권9호
    • /
    • pp.787-797
    • /
    • 2011
  • The noise in a vehicle is an important factor for customers purchasing a car. Particularly, reduction of the noise that is generated from HVAC(heating, ventilation and air conditioning) is very important since it has considerable effects on interior noise. In general, identification of noise source is crucial to reduce noise level. The complex acoustic intensity method is widely used to obtain the accurate measurement and identification of noise source. Therefore, in the previous study, noise source of HVAC was identified through experimental approach using the complex acoustic intensity method. In this study, we are intended to confirm reduced level of noise by comparing the result between before and after modification of cam curve that is based on identified noise source of HVAC. It is found out that noise source of HVAC are motor and cam area using the complex acoustic intensity method in the previous study. We performed experiments to compare noise level between before and after modification of cam curve. Especially, it can be seen that complex acoustic intensity method using both active and reactive intensity is vital in devising a strategy for comparison to noise level. Also, the vector flow of acoustic intensity was investigated to identify sound intensity distributions and energy flow in the near field of HVAC.

철도차량 HVAC시스템의 광플라즈마 성능평가 (Efficiency of Photoplasma of HVAC System for Train)

  • 한환수;전승기;박태영;김봉상;박덕신;권순박
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 춘계학술대회 논문집
    • /
    • pp.1293-1296
    • /
    • 2007
  • An amenity requirement of the passenger using public traffic is rising continuously, and also The Ministry of Environment established "Indoor air quality management guidelines in public facilities(Dec. 2006)". To satisfy such requirement, the photoplasma device to decrease VOCs(Volatile Organic Compounds) and suspended bacillus is applied to the underframe mounted HVAC(Heating, Ventilating and Air-Conditioning) system for train. Air purifying method of photoplasma device is optical and chemical reaction that UV-light(wavelength less than 280nm) react with catalyst material(TiO2). To analyze the efficiency of photoplasma in this study, we measured the requirement time for toluene to decease down to 0.3ppm after contaminating the passenger cabin for train to toluene 1ppm.

  • PDF

$CO_2$제어 개보수 평가

  • Schell, Mike;Smith, Doug
    • 대한설비공학회지:설비저널
    • /
    • 제32권6호
    • /
    • pp.49-56
    • /
    • 2003
  • CO2환기제어는 신축건물에서 흔히 사용되고 있지만, 기존의 건물에서는 그 적용 예가 흔하지는 않다. 아마도 개보수라는 것이 가능하다고 여겨지는 자원절감이나 이익에 대한 방대한 기록이 요구되기 때문이며 게다가 제어에 관한 개보수는 복잡하다는 인식에 기인한다. 공교롭게도, 에너지 사용 패턴에 대하 명확한 기록이 있는 기존의 건물에 가장 에너지절약적인 기회가 많다는 사실이다. 이 기고문에서는 기존 건물의 CO2개보수에 관하여 그 성능 평가에 대한 방법론을 제시하고 있으며, 현장 평가와 이 방법론을 적용한 A-등급 사무소 건물에서의 개보수를 통한 성능개선에 관하여 분석하고 있다. 대상은 첨단 DDC시스템이 있는 미국 환경청의 에너지스타 등급을 획득한 건물이다.

  • PDF

인공신경망 변수에 따른 HVAC 에너지 소비량 예측 정확도 평가 - 송풍기를 중심으로- (An Analysis of the Prediction Accuracy of HVAC Fan Energy Consumption According to Artificial Neural Network Variables)

  • 김지헌;성남철;최원창;최기봉
    • 대한건축학회논문집:구조계
    • /
    • 제34권11호
    • /
    • pp.73-79
    • /
    • 2018
  • In this study, for the prediction of energy consumption in the ventilator, one of the components of the air conditioning system, the predicted results were analyzed and accurate by the change in the number of neurons and inputs. The input variables of the prediction model for the energy volume of the fan were the supply air flow rate, the exhaust air flow rate, and the output value was the energy consumption of the fan. A predictive model has been developed to study with the Levenbarg-Marquardt algorithm through 8760 sets of one-minute resolution. Comparison of actual energy use and forecast results showed a margin of error of less than 1% in all cases and utilization time of less than 3% with very high predictability. MBE was distributed with a learning period of 1.7% to 2.95% and a service period of 2.26% to 4.48% respectively, and the distribution rate of ${\pm}10%$ indicated by ASHRAE Guidelines 14 was high.8.

실내오염물질의 환기기술전략에 따른 영향평가 : 수치적 모델을 이용한 HVAC 시스템의 비교연구 (The Impact of Ventilation Strategies on Indoor Air Pollution: A Comparative Study of HVAC Systems Using a Numerical Model)

  • Park, Sung-Woo;Song, Dong-Woong;D.J. Moschandreas
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제11권E호
    • /
    • pp.45-54
    • /
    • 1995
  • Indoor air quality models are useful to predict indoor air pollutant concentrations as a function of several indoor factors. Indoor air quality model was developed to evaluate the pollutant removal efficiency of variable-air-volume/bypass filtration system (VAV/BPFS) compared with the conventional variable-air-volume (VAV) system. This model provides relative pollutant removal effectiveness of VAV/BPFS by concentration ratio between the conventional VAV system and VAV/BPFS. The predictions agree closely, from 5 to 10 percent, with the measured values for each energy load. As a results, we recommend the VAV/BPFS is a promising alternative to conventional VAV system because it is capable of reducing indoor air pollutant concentration and maintaining good indoor air quality.

  • PDF

폐열회수환기를 위한 열교환장치의 경제성 평가 (An economic evaluation of heat exchanger for heat recovery ventilation)

  • 박용효;이상범
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2008년도 추계 학술논문 발표대회
    • /
    • pp.241-244
    • /
    • 2008
  • Recently, The high Air-Tightness and high heat insulation for building construction cause a ventilation air volume deficiency. Also, Worldwide high energy price is strongly urging to economize the air conditioning energy. Therefore Heat Recovery Ventilation is used for the satisfaction of ventilation air volume and building energy saving. Accordingly, this study dose the heat exchanger performance evaluation and economic efficiency evaluation of Heat Recovery Ventilation. And, we wish to make a basic study about HRV System application of HVAC System and Multi System Air-conditioning.

  • PDF