• Title/Summary/Keyword: HV%

Search Result 1,031, Processing Time 0.021 seconds

A Study on the Fabrication and Electrical Characteristics of High-Voltage BCD Devices (고내압 BCD 소자의 제작 및 전기적 특성에 관한 연구)

  • Kim, Kwang-Soo;Koo, Yong-Seo
    • Journal of IKEEE
    • /
    • v.15 no.1
    • /
    • pp.37-42
    • /
    • 2011
  • In this paper, the high-voltage novel devices have been fabricated by 0.35 um BCD (Bipolar-CMOS-DMOS) process. Electrical characteristics of 20 V level BJT device, 30/60 V HV-CMOS, and 40/60 V LDMOS are analyzed. Also, the vertical/lateral BJT with the high-current gain and LIGBT with the high-voltage are proposed. In the experimental results, vertical/lateral BJT has breakdown voltage of 15 V and current gain of 100. The proposed LIGBT with the high-voltage has breakdown voltage of 195 V, threshold voltage of 1.5 V, and Vce, sat of 1.65 V.

Effects of Ground Faults on the Safety of Persons in High Voltage Distribution Systems (고압계통 지락고장시 인체안전에 미치는 영향)

  • Kang, Sung-Man;Kim, Han-Soo;Lee, Jong-Chul;Lee, Ju-Chul
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.195-197
    • /
    • 2007
  • This paper presents experimental results on the safety of persons due to a ground fault in 22.9 kV-Y distribution system In order to evaluate the touch voltages due to internal ground faults in a step down transformer based on the newly prescribed KS C IEC 60364 standard series, the verification tests in a 22.9 kV multi-grounded neutral system were carried out From the experimental results, it was found that there will be significant potential rise jeopardizing LV equipment insulation in case of separate grounding between HV and LV system and the effective measures against hazardous touch voltages due to a IN side ground fault in the common grounding system between HV and LV system are proposed. As a consequence, it was found that the equipotential bonding is an important prerequisite for the effectiveness of the protective measures for the safety of persons in the common ground system between 22.9 kV-Y and low-voltage grounding system.

  • PDF

A Highly-Integrated Analog Front-End IC for Medical Ultrasound Imaging Systems (초음파 의료 영상시스템용 고집적 아날로그 Front-End 집적 회로)

  • Banuaji, Aditya;Cha, Hyouk-Kyu
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.12
    • /
    • pp.49-55
    • /
    • 2013
  • A high-voltage highly-integrated analog front-end (AFE) IC for medical ultrasound imaging applications is implemented using standard 0.18-${\mu}m$ CMOS process. The proposed AFE IC is composed of a high-voltage (HV) pulser utilizing stacked transistors generating up to 15 Vp-p pulses at 2.6 MHz, a low-voltage low-noise transimpedance preamplifier, and a HV switch for isolation between the transmit and receive parts. The designed IC consumes less than $0.15mm^2$ of core area, making it feasible to be applied for multi-array medical ultrasound imaging systems, including portable handheld applications.

An Experimental Study on the Absorbed Energy of Polymeric Foam According to Different Mass and Impact Velocity Based on the Constant Impact Energy (동일 에너지 조건하에 충격체 질량과 속도변화에 따른 발포 고분자의 흡수 에너지에 관한 실험적 연구)

  • Kim, Byeong-Jun;Kim, Han-Kook;Cheon, Seong S.
    • Composites Research
    • /
    • v.27 no.2
    • /
    • pp.42-46
    • /
    • 2014
  • In the present study, impact tests were carried out to investigate the crashworthy behaviour of the expanded polypropylene under the constant incident energy (100 J and 200 J) with five different combinations of striker mass and velocity. Also, preliminary quasi-static test was performed to obtain basic characteristics of the expanded polypropylene. MTS 858 and Instron dynatup 9250 HV were used for the quasi-static test and impact tests, respectively. In consequence, it was found that the impact energy absorption characteristics of the expanded polypropylene was more influenced by the striker mass instead of the velocity of the striker.

A study on the hardening characterstics of the TiC layer formed by the reactive deposition technique (반응석출법에 의해 피복된 TiC의 경화거동에 관한 연구)

  • Nam, K.S.;Byon, E.S.;Lee, G.H.;Kim, D.H.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.7 no.4
    • /
    • pp.288-297
    • /
    • 1994
  • In this study, lattice parameter, binding energy and microstructures of TiC layer according to the addition of Fe, Cr were investigated in the reactive deposition coating. From the results, the lattice parameters of the TiC layers by using ferro-titanium as a precursor were 4.329~4.339A but the lattice parameters of the TiC layers formed by ferro-titanium and ferro-chromium decreased to 4.316~4.330A. The hardness of the former's was HV(100g) 3,000~3,400kg/mm and the hardness of the latter's was HV (100g) 3,800~3,900. But, regardless of Cr and Fe, the binding energy of TiC layers were 454.75 eV for $Ti2p_{3/2}$ and were 281.85 eV for Cls. Meanwhile, the TiC layers were densified by addition of Fe, Cr and internal defects were reduced Therefore. it can be concluded that the remarkable hardness increment was obtained by the improvement of microstructures of TiC rather than the increase of bond strength or Peierls stress.

  • PDF

Reliability of Thickness Measurements of the Abductor Hallucis Muscle Using the Spring Gauge Technique in Hallux Valgus Subjects: An Ultrasonographic Study

  • Jeon, In-cheol;Kim, Moon-Hwan
    • The Journal of Korean Physical Therapy
    • /
    • v.28 no.2
    • /
    • pp.119-123
    • /
    • 2016
  • Purpose: The purpose of this study was to determine the intra- and inter-rater reliability of muscle thickness (MT) measurements of the abductor hallucis (AbdH) in subjects with hallux valgus (HV), using ultrasonography performed at different inward pressures of approximately 0.5 kg, 1.0 kg, 1.5 kg, and 2.0 kg, with no pressure control. Methods: Thirty-two subjects with HV were recruited. The thicknesses of both sides of the AbdH were measured randomly by two different examiners for assessment of the intra- and inter-rater reliability. The measurement values were analyzed using the intra-class correlation coefficient (ICC) with a 95% confidence interval (CI). ICC (2,1) was used to determine the inter-rater reliability of MT measurements of the AbdH, while ICC (3,1) was used to assess the intra-rater reliability. Results: The results showed higher ICC values for intra-rater reliability compared to inter-rater reliability, and the value for inter-rater reliability with no pressure control (ICC=0.74 [95%CI=0.53-0.87]) was smaller compared to pressures of 0.5 kg, 1.0 kg, 1.5 kg, and 2.0 kg. Other inward pressures for intra- and inter-rater reliability also showed excellent values (ICC=0.86-0.96). Conclusion: The findings showed that maintaining consistent inward pressure is essential for reliable results in measurement of the MT of the AbdH by different examiners in a clinical setting.

Fabrication and Properties of Ni and Ni-W Electroplated Molds Using LIGA-like Process for Replication of Micro Components (LIGA-like 공정을 이용한 마이크로 부품 복제용 Ni과 Ni-W 금형 제조 및 특성)

  • Hwang, W.S.;Park, J.S.;Kang, Y.C.;Cho, J.W.;Park, S.S.;Lee, I.G.;Kang, S.G.
    • Korean Journal of Materials Research
    • /
    • v.13 no.1
    • /
    • pp.6-10
    • /
    • 2003
  • Electroplated Ni and Ni-W micro-molds using LIGA-like process for replication of micro-components such as microfluidic parts and micro optical parts have been investigated. In general, it is hard to produce micro-parts using conventional mechanical processes. Micro-mold formed by LIGA-like process could fabricate micro-parts with high aspect ratio. In this paper, fabrication and properties of electroplated Ni molds with varying applied current types as well as those of Ni-W molds were investigated. Ni molds fabricated under pulse-reverse current showed the highest hardness value of about 160 Hv. Ni-W molds showed the hardness of about 500 Hv which was much harder than that of Ni electroplated molds. The above results suggested that high quality micro-molds could be fabricated by using Ni electroplating of pulse-reverse type for core molds and sequential Ni-W alloys coating.

On Evaluation of Material Properties in Spring Steels by Measurement of Ultrasonic Techniques (초음파법에 의한 스프링강의 재질평가에 관하여)

  • Kim, Sang-Su;Ha, Kyung-Jun;Kim, Seon-Jin
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.41-46
    • /
    • 2002
  • The general purpose of this paper is Evaluation of material properties in spring steels by investigate correlation between ultrasonic attenuation and virker's hardness, charpy impact properties, microstructures. The three test speciments of the $490{\times}90 mm$ plates and 20 mm thick are used but differ in heat treatment, one is rolled plate, the second is quenched and then tempered, and the third is quenched. ultrasonic attenuation were obtained at fifteen locations on the plates. In order to investigate the correlation between hardness ( especially, HV ) and the attenuation, the virker's hardness and the microstructures were observed for three spring steels. also the charpy impact test were carried out at the room temperature in order to investigate the relationship between impact properties and the attenuation. The experimental results obtained from three different spring related to the heat treatment conditions and attenuation coefficient is increased with increasing the hardness(HV). Ultrasonic attenuation coefficients have shawn are ability to distinguish among spring steels.

  • PDF

Analysis of Temperature Characteristic According to Variation of Air Duct of the Cast Resin Transformer (몰드변압기의 공기덕트의 구조 변화에 따른 온도특성 해석)

  • Kim, Ji-Ho;Lee, Hyang-Beom;Shon, Jin-Geun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.64 no.4
    • /
    • pp.256-260
    • /
    • 2015
  • In this paper, achieved rise temperature distribution about degradation phenomenon of 24 MVA distribution cast resin transformer using CFD(Computational Fluid Dynamics). Usually, life of transformer is depended on temperature distribution of specification region than thermal special quality of transformer interior. Specially, life of transformer by decline of dielectric strength decreases rapidly in case rise by strangeness transformer interior hot spot temperature value permits. Because calculating high-voltage(HV) winding and low-voltage(LV) winding of cast resin transformer and Joule's loss of core for improvement these life, forecasted heat source, and HV winding and LV winding of cast transformer rise temperature distribution of core for supply of electric power and temperature distribution of highest point on the basis of the results. Also, calculated temperature rise limit of cast resin transformer and permission maximum temperature using analysis by electromagnetic heat source. Calculated and forecasted rise temperature distribution by heat source of thermal analysis with calculated result.

A Study on the AC Interfacial Breakdown Properties of the Interface between Epoxy/EPDM with Variation of the Spread Oil (도포된 오일의 변화에 따른 Epoxy/EPDM 계면의 교류 절연파괴 특성에 관한 연구)

  • Bae, Deok-Gwon;Jeong, Il-Hyeong;O, Jae-Han;Park, U-Hyeon;Lee, Gi-Sik;Kim, Chung-Hyeok;Lee, Jun-Ung
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.8
    • /
    • pp.445-450
    • /
    • 2000
  • Many successful developments and microscopic studies have been made on the high quality insulating materials. However, a little attention have given to the macroscopic interface in HV(High Voltage) insulating systems. In this study, AC interfacial breakdown strength and V-t characteristic of the interface between Epoxy/EPDM(ethylene propylene diene terpolymer) are investigated. Electrode system is designed to reduce the charges from electrodes and to have the tangential potentials along the interface between Epoxy/EPDM by FEM(finite elements method). The AC breakdown strength is observed when HV is given to the interface. It is shown that AC interfacial breakdown strength is improved by increasing interfacial pressure and oiling. In particular, it was saturated at certain interfacial pressure level. V-t characteristic is able to extend to the life time of the interface between Epoxy/EPDM. Oiling also plays a good roll in prolongation of the life time.

  • PDF