• Title/Summary/Keyword: HV%

Search Result 1,031, Processing Time 0.031 seconds

Discharge Waveform Properties on Electrical Sterilization by HV Impulse (고전압 펄스에 의한 전기 살균에서 방전 파형의 특성 분석)

  • Lee, H.K.;Suehiro, J.;Hara, M.;Lee, D.C.
    • Proceedings of the KIEE Conference
    • /
    • 1998.11c
    • /
    • pp.944-946
    • /
    • 1998
  • We evaluated cell survivability by changing RLC value on HV impulse network. When the L value is changed from 0 to 10mH in this circuit. we found that cell survivability is shown large decline with 4mH of L value. I respect to this result, when waveshapes of oscillatory decay are presented along the variation of L value in RLC circuit, we analyzed whether discharge waveform properties have an effect on sterilization ratio, and measured threshold voltage as the minimum peak voltage of a single pulse which can sterilize cells. Finally, we found that the sterilization effect was related to number of threshold voltage waveforms being applied.

  • PDF

Microstructure and wear performance of WC-6.5%Co cladding layer by electric resistance welding (저항 클래딩법에 의해 형성된 내마모성 WC-6.5Co 클래딩층의 미크로조직 및 내마모성능)

  • Lee, Jin-U;Bae, Myeong-Il;Kim, Sang-Jin;Lee, Yeong-Ho
    • Proceedings of the KWS Conference
    • /
    • 2006.10a
    • /
    • pp.120-122
    • /
    • 2006
  • This study deals with characterizations of microstructure and wear performance of a cladding layer, product on 1.9 mm-thick mild steel plate by the electric resistance welding, of composite metal powder of Coarse WC-6.5%Co and high carbon alloy(SHA). The cladding layer was examined and tested fur microstructural features, chemical composition, hardness, wear performance and wear mechanism. The cladding layer have two different matrix were observed by an optical microscope and EPMA. The one was the coarse WC-6.5Co structure. The other was the melted SHA with surrounding the WC-6.5Co structure. The hardness of WC-6.5Co was 1210HV. The hardness of SHA was 640HV. In comparison by wear rate, the cladding layer showed the remarkable wear performance that was 15 times of SM490 and about 62% of D2.

  • PDF

Wear Resistant Steel Plate for Heavy Duty Vehicle (건설 중장비에 적용가능한 내마모 강판)

  • 김기열;이범주;조정환;류영석;이동욱
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1998.04a
    • /
    • pp.271-276
    • /
    • 1998
  • To apply the wear resistant steel plate for heavy duty vehicle, the wear characterisms of various kinds of commercial steel plates were invesigated by dry sand/rubber wheel tester which was tested under scratch abrasion mode. The wear tested pnaterials were boron steels which were manufactured by thereto machanical control process (TMCP) in order to achieve higher hardness. As the result of the test, wear resistance of steel plate increases with the hardness and carbon content. The wear loss of wear resistance steel plate (Hv440) is a half times than tinat of SWS490A (Hv160) steel plate in dry sand-rubber wheel test and the result in field test is similar to this dry sand/rubber wheel test result. Therefore, dry sand/rubber wheel tester can be used to predict the scratch abrasion life of the parts for heavy duty vehicle.

  • PDF

Poly$({\beta}-hydroxybutyrate-co-3-hydroxyvalerate)$의 생분해도에 미치는 hydroxyvalerate 함량의 영향

  • Im, Seol-Hui;Jo, Gyeong-Suk;Ryu, Hui-Uk;Choe, Hui-Sik
    • 한국생물공학회:학술대회논문집
    • /
    • 2000.11a
    • /
    • pp.175-178
    • /
    • 2000
  • Biodegradability of the $poly({\beta}-hydroxybutyrate-co-3 -hydroxyvalerate)$ [PHB/V] containing 0, 10 and 15mol% hydroxyvalerate [HV] was studied. Bioderadability of PHB/V was evaluated at $30^{\circ}C$ for 58 days and $55^{\circ}C$ for 33 days by monitoring the time-dependent changes in weight loss(erosion) of aerobic conditions in a temperature-controlled microcosms containing the earthworm cast($30^{\circ}C$) and compost ($55^{\circ}C$). It was found that PHB/V biodegradability occurred with increasing HV monomer concentration from 0 mol% to 15 mol%.

  • PDF

Development of Deterioration Detecting System for Aged ACSR-OC Conductors in HV Overhead Distribution Lines (고압 가공배전선의 노화된 ACSR-OC 도체에 대한 열화검출시스템 설계)

  • Kim, Sung-Duck;Lee, Seung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2000.11a
    • /
    • pp.232-235
    • /
    • 2000
  • Design and experiments of a nondestructive system to inspect deterioration of ACSR-OC (ACSR Outdoor Cross-linked Polyethylene Insulated Wire usually used in HV overhead distribution lines presented in this paper. ACSR-OC conductor built to pollutants air for a long period would be easily progress to corrode so that it may lead to the reduction of the effective cross section area of conductors. A fault diagnosis system consisting of a solenoid sensor, a constant current source with RF frequency signal processing unit and a motor driver/controller designed and implemented. This instrument can dot the sensor output variation due to deterioration corrosion, continuously. As a result, it was shown such corrosion detector can readily be utilized estimating the diameter change due to deterioration overhead distribution lines and in giving an warning or inform before severe aged conductor lead to fail.

  • PDF

CONSIDERATION OF SHRINK-BACK FOR HV CV CABLE (HV CV 케이블의 SHRINK-BACK현상에 대한 고찰)

  • Kim, J.W.;Kim, H.K.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1993.05a
    • /
    • pp.49-51
    • /
    • 1993
  • Recently, use of High Voltage cables with extruded insualtion is increasing. Generally this polymeric insuation contains residual stresses. The effect of internal residual stresses is the so-called shrink-back of the insulation. If not controlled, these stresses may lead to problems during installation and service of the cables. Therefore in this paper, the definition and cause of shrinkage are described and furthermore the influence due to shrink-back at cable joint-box.

  • PDF

12%-Cr 강의 C0$_{2}$레이저 표면 경화

  • 김재도
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1992.04a
    • /
    • pp.84-88
    • /
    • 1992
  • Laser beam hardenling of 12%-Cr steel has been evaluated by using a continuous wave 3 kW CO$\_$2/ laser with a hardening mirror set. Experiment was performed on the optimum hardening condition with a laser power of 2.85kW and travel speed of 10 and 5 m/min. Multi passes have been alsotried to find the hardening characteristics of partly overlapped zone. The black paint to use at high temperature was adopted to increases the absorptivity of laser beam energy with the wavelength of 10.6 .mu. m at the surface of bese metal. The microstructure of the hardened layers was observed by using a light microscopy. SEM and TEM. A fine lamellar martensite formed in the hardened zones exhibits very high Vickers microhardness of 600 Hv, whereas the tempered martesite distributes in the base metal with Vickers microhardness of 240 Hv. It has been found that laser hardening with multi pass showed no significant drop of the hardness between adjacent passes.

Mural folliculitis and alopecia caused by infection with malignant catarrhal fever virus in goat (Capra hircus) (Malignant catarrhal fever virus 감염과 관련된 goat (Capra hircus)의 mural folliculitis와 alopecia)

  • Kim, Ok-Jin;Crawford, Timothy B.
    • Korean Journal of Veterinary Pathology
    • /
    • v.7 no.1
    • /
    • pp.5-9
    • /
    • 2003
  • Malignant catarrhal fever (MCF) is a systemic disease of ruminants caused by a gamma herpesvirus, ovine herpesvirus 2 (OvHV-2). Four 1-year old goats (Capra hircus), which were infected with MCF virus, OvHV-2, by being housed together with MCF virus-infected seep, were referred with a I-month history of chronic dermatitis. On the other hand, MCF virus-negative goats, which were isolated for negative control, had not those kinds of skin problems. Examination of the affected goats revealed generalized alopecia, patchy erythema, and superficial erosions with histologic evidence of mural folliculitis. Fungal culture tests and external parasite tests with the scraping skin samples were negative. However, polymerase chain reaction revealed the existence of MCF virus DNAs in the lesion. These results suggested that MCF virus may induce mural folliculitis and alopecia in goat.

  • PDF

On-Line System for Partial Monitoring Discharge (온라인 부분방전 감시 시스템)

  • Choi, Yong-Sung;Hwang, Jong-Sun;Lee, Kyung-Sup
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.2114-2115
    • /
    • 2008
  • We consider the relation between on-line monitoring and diagnostics on the one hand and high-voltage (HV) withstand and partial discharge (PD) on-site testing on the other. HV testing supplies the basic data (fingerprints) for diagnostics. In case of warnings by on-line diagnostic systems, off-line withstand and PD testing delivers the best possible information about defects and enables the classification of the risk. Frequency tuned resonant (ACRF) test systems are best adapted to on-site conditions. They can be simply combined with PD measuring equipment. The available ACRF test systems and their application to electric power equipment -from cable systems to power transformers is described.

  • PDF

GENERALIZED LATIN SQUARE

  • Iranmanesh A.;Ashrafi A.R.
    • Journal of applied mathematics & informatics
    • /
    • v.22 no.1_2
    • /
    • pp.285-293
    • /
    • 2006
  • Let X be a n-set and let A = [aij] be a $n {\times} n$ matrix for which $aij {\subseteq} X$, for $1 {\le} i,\;j {\le} n$. A is called a generalized Latin square on X, if the following conditions is satisfied: $U^n_{i=1}\;aij = X = U^n_{j=1}\;aij$. In this paper, we prove that every generalized Latin square has an orthogonal mate and introduce a Hv-structure on a set of generalized Latin squares. Finally, we prove that every generalized Latin square of order n, has a transversal set.