• 제목/요약/키워드: HTS tapes

검색결과 215건 처리시간 0.025초

Design and Test Results of 6-kA HTS-Copper Current Leads with HTS Section Operating in the Current-Sharing Mode

  • Lee, Haigun;Kim, Ho-Min;Yukikazu Iwasa;Kim, Keeman;Paul Arakawa;Greg Laughon
    • KIEE International Transactions on Power Engineering
    • /
    • 제3A권2호
    • /
    • pp.100-108
    • /
    • 2003
  • This paper presents the design and performance results of a pair of 6-kA high-temperature superconducting (HTS)-copper current leads, in which, over a short length at the warm end (e.g.,77K) of each HTS section, comprised of paralleled Bi-2223/Ag-Au tapes, is operated in the current-sharing mode. Because of their reliance on vapor cooling, the leads are applicable only to liquid helium cooled superconducting magnets such as those used in high-energy Physics accelerators and fusion machines. The experimental measurements have demonstrated that key performance data of the new 6-kA HTS-Copper leads agree reasonably well with those expected from design.

Bi-2223/Ag 고온초전도 장선재의 제조 (Fabrication of long length Bi-2223/Ag HTS tape)

  • 김상철;이동훈;하동우;오상수
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 추계학술대회 논문집 Vol.17
    • /
    • pp.69-72
    • /
    • 2004
  • In order to use HTS tape on electric power applications, such as cable, motor, transformer, fault current limiter, a long length of HTS tape with a good uniformity of critical current is inevitable. The longer length of HTS tape, the wider in the range of application and the lower cost of HTS tape. In this study three long length Bi-2223/Ag tapes(268m, 253m and 187m) were fabricated. Critical current uniformity along the length was greatly improved through the optimization of cold deformation and thermo-mechanical process. Average critical current of the tapes was 63.2 A, 54.6 A and 64.2 A, respectively Critical tensile strength and critical bending radius (77 K, 5 % Ic degradation) was 135 MPa and 56 m, respectively.

  • PDF

고온초전도선재의 자화손실 측정 (Measurement of the Magnetization Loss in a HTS Tape)

  • 심정욱;이희준;차귀수;이지광;한송엽
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제48권4호
    • /
    • pp.182-186
    • /
    • 1999
  • Evaluation of the AC losses in the HTS tapes which are used in electric power machines in one of the important topics in this field. This paper deals with the calculation and measurement of the magnetization loss in HTS tapes. Bean model is adopted for the theoretical calculation of the magnetization loss. Magnetization method is used for the measurement of the loss. Two types of the HTS tape model, multi-filamentary model and mono-filamentary model, are used to evaluate the magnetization loss in this paper. According to the results of the analysis, large discrepancy between the calculated and measured value is observed in multi-filamentary model is more useful than multi-filamentary model for the evaluation of the magnetization loss.

  • PDF

초전도 전력케이블의 전력계통 적용을 위한 고장전류 특성에 관한 연구 (A Study on the Fault Current Characteristics for the Utility Application of HTS Power cable)

  • 김재호;박민원;심기덕;조전욱;유인근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.75-76
    • /
    • 2007
  • Several kinds of High Temperature Superconducting(HTS) power cables have already been developed and evaluated for use in the utility power network. HTS power cable is expected to be used as a very powerful energy delivery system supplying electric power for densely populated cities in the near future, because HTS power cable is capable of the high current density delivery with low AC loss and the size effect comparing with the conventional cable whose capacity is same. Before applying the HTS power cable to real utility network system analysis should be carried out by some simulation tools. Hereby the electrical power system analysis is very important for the practical use of HTS power devices. In this paper, authors propose a real-time simulation method which incorporates a real HTS tapes into the simulated 22.9kV utility power network system using Real Time Digital Simulator(RTDS). For the simulation analysis, a test sample of HTS tapes was actually manufactured, and the transient phenomenon of HTS power cable system was analyzed in the simulated utility power network.

  • PDF

The effect of mechanical working on processing the Bi-2223/Ag tapes using PIT method

  • Oh, S.S.;Ha, D.W.;Kim, S.C.;Bae, S.W.;Kwon, Y.K.;Ryu, K.S.;Ha, H.S.
    • 한국초전도학회:학술대회논문집
    • /
    • 한국초전도학회 2000년도 High Temperature Superconductivity Vol.X
    • /
    • pp.276-279
    • /
    • 2000
  • When high temperature superconducting tapes is fabricated using the PIT (Powder In Tube) method, the length of HTS tapes is increased more than 500 ${\sim}$ 1,000 times of initial powder packed billet. On mechanical processing, heterogeneous properties between the ceramic superconducting core and Ag/Ag alloy sheath occur the non-uniformity deformation as like sausaging that deteriorate the critical current properties of HTS tapes. In this study, we investigated the workability of Bi-2223/Ag/Ag alloy sheath tapes fabricated by the PIT method involving a number of different mechanical processes, multi drawing and rolling. In order to obtain the high critical current density and high uniformity of Bi-2223/Ag sheath tapes, the influences of powder packing density, drawing die angle and rolling parameters were studied. We found that the roll diameter is an important variable in the rolling process, as critical current of tapes rolled using 250 mm rolls was higher than that using 150 mm rolls.

  • PDF

Magnetization of the stack of HTS tapes

  • Osipov, M.A.;Abin, D.A.;Pokrovskiy, S.V.;Mineev, N.A.;Rudnev, I.A.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제17권1호
    • /
    • pp.21-24
    • /
    • 2015
  • New results of dependence of magnetic field, trapped by a stack of HTS tapes, on amount of tapes in a stack are reported. Commercial GdBCO tape 12 mm width and without Cu layer was used for the research. Tape was divided in square pieces $12{\times}12mm^2$ from which stacks were formed. Filling factor of the tape was about 1.4%. Measurements were carried out for stacks with height from 5 to 250 pieces and at wide temperature range from liquid helium to liquid nitrogen. Both FC (field cooling) and ZFC (zero field cooling) cooling methods were used in the research. These two methods show matching results with good accuracy. As a result dependences of trapped magnetic flux on amount of tapes for different temperatures were received. Research shows, that with increasing height of the stack trapped magnetic field value reach saturation at about 60 tapes in a stack for low temperatures. From 60 to 100 tapes increase of magnet flux is only 5%. Thus increase amount of tapes in a stack is not profitable. Also investigation of trapped magnet field relaxation was carried out. Relaxation speed decreases with increasing amount of elements. It means that the higher the stack is, the longer trapped flux will be held in cause of the same temperature.

고온초전도 선재의 Bending횟수에 따른 임계전류의 특성 (Characteristic of Critical Current after Repetitive Bending for High Superconducting Tapes)

  • 김해준;주진홍;김석환;김해종;배준한;조전욱;성기철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 B
    • /
    • pp.900-902
    • /
    • 2003
  • Critical current($I_c$) degradation of HTS tapes after bending is one of the holiest issues in HTS development and application studies. Many people are measuring $I_c$ degradations for effect of tending radius. However even if the bending radius is larger than the breaking radius a HTS tapes can be damaged by repetitive bending, which is unavoidable in the winding processes. Therefore, We studied the $I_c$ degradation after repetitive bending, at 77K with self-field, of Bi-2223 tapes processed by "Powder-in-Tube" technique, which was made by America Superconductor Corporation(AMSC), Innova Superconductor Technology(InnoST) and Korea Electro-technology Research Institute(KERI). For each specimen $I_c$ degradation was measured various bending radius as function of repetitive bending number.

  • PDF

멀티케이블을 이용한 초전도 전력케이블의 구성에 관한 연구 (A Study on the Composition of Superconducting Power Cable Using the Multi-cable)

  • 최석진;이상진;심기덕;조전욱;이수길;고태국
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제12권1호
    • /
    • pp.42-46
    • /
    • 2010
  • The HTS power cable is composed of 2 layers for transmission and 1 layer for shield. The superconducting tapes of transmission layers and shield layer are wound in a cylindrical shape with a winding pitch. The radius of cylinder and the number of superconducting tapes are decided considering to the transmission current capacity and the critical current of superconducting tapes. The increasement of transmission current capacity will increase in volume of HTS cable system. In this paper, the composition method of supercondcuting power cable using the multi-cable is presented. The coated conductor tape can be wound on the smaller cylinder because it has the smaller critical bending diameter than the BSCCO tape. A small-scale cable was composed using the coated conductor tapes and a multi-cable is composed using a small-scale cable considering to transmission current capacity. Even increase of transmission current capacity, this method has advantage that the HTS superconducting power cable can be composed easily. The 22.9 kV and 154 kV superconducting power cable was composed using the presented method.

열처리 온도 및 분위기 변화에 따른 Bi-2223 초전도 선재에서의 특성변화 (superconducting properties of Bi-2223 tapes with various heat treatment condition)

  • 하동우;이동훈;하홍수;오상수;김홍대;양주생;윤진국;최정규;권영길
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집
    • /
    • pp.527-530
    • /
    • 2002
  • A lot of efforts have been focused on the optimization of PIT parameters for Bi-2223/Ag wire. In this paper, initial annealing of Bi-2223/Ag wire to transform Bi-2212 orthorhombic from Bi-2212 tetragonal Precursor was investigated. This initial annealing step at low oxygen partial pressure were to transform Bi-2212 orthorhombic structure and to reduce the formation of second phases at superconducting wire. However Bi-2223 Phases were appeared at higher annealing temperature. Critical currents(Je) of Bi-2223/Ag tapes were sintered at low oxygen Partial pressure were higher than that of the wires sintered at atmosphere condition. In order to investigate the effect of rolling reduction ratio, Bi-2223/Ag HTS tapes were rolled with different reduction ratio. There were no clear difference of Je and filaments shape with various rolling reduction ratio.

  • PDF

500 m급 Bi-2223/Ag 고온초전도 선재의 균일 가공 및 임계전류 특성 (Uniform deformation and Critical Current properties of 500 m class Bi-2223/Ag HTS tapes)

  • 이동훈;양주생;최정규;윤진국;황선역;김상철;하홍수;하동우;오상수
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 학술대회 논문집
    • /
    • pp.85-87
    • /
    • 2003
  • Intermediate annealing was carried out during wire drawing for uniform deformation of 500 m class Bi-2223/Ag HTS tapes. Wire drawing force was measured to evaluate the uniformity of wire deformation along the length. To prevent sausage and filament breakage of wire, drawing stress was controlled below 200 MPa by using intermediate annealing process. Thickness and width of the rolled tapes was measured 0.23 mm and 4.1 mm with low deviation $\pm$ 0.08 mm and $\pm$ 0.09 mm, respectively. The critical current of the 500 m tapes was measured 33.7 A $\pm$ 3.7 A by continuous critical current measurement system.

  • PDF