• Title/Summary/Keyword: HTS tapes

Search Result 215, Processing Time 0.025 seconds

Evaluation of mechanical properties of Bi-2223/Ag HTS tapes (Bi-2223/Ag 고온초전도 선재의 기계적 특성 평가)

  • 하홍수;이동훈;양주생;최정규;윤진국;하동우;오상수;권영길
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2002.02a
    • /
    • pp.351-354
    • /
    • 2002
  • In most of electrical applications using Bi-2223/Ag HTS tapes, bending and tension stresses are essentially applied to the tape. Therefore, the critical current of the Bi-2223/Ag tape is degraded by increasing the deformation stress, though brittle superconducting filaments are embedded in the reinforced Ag alloy sheath. It is needed to understand bending and tension properties of HTS tapes at room temperature and cryogen to make superconducting magnet, cable and etc. using Bi-2223/Ag HTS tapes. Actually, bending and tension stress applied to the tapes simultaneously, when winding the tapes on former for applications. In this study, the effect of mechanical deformations, bending and tension, on the critical current of Bi-2223/Ag tape was investigated.

  • PDF

Numerical Analysis of Transport Current Losses in Stacked HTS Conductors (적층 형태의 고온 초전도선재에서의 통전손실 수치 해석)

  • 최세용;나완수;김정호;주진호;류경우
    • Progress in Superconductivity
    • /
    • v.5 no.2
    • /
    • pp.89-93
    • /
    • 2004
  • We have studied alternating transport current losses in the vertically stacked high temperature superconducting tapes(HTS) using numerical techniques. In the case of stacked conductors, HTS tapes are exposed to self-field generated by transport current itself and also experienced external magnetic field around adjacent tapes. It is well known that magnetic interactions between neighbored tapes have significant effect on their properties of superconducting tapes such as current distribution, AC loss, and critical current. In this paper, we investigated the transport current losses in stacked conductors consisting of a few of the HTS tapes using numerical analysis. Current distributions are calculated in HTS tape cross-section taking account of magnetic field dependencies, which are represented superconducting nonlinear properties. Dissipated losses in tape and stacked conductors were integrated with current distribution and electric field intensity in the whole conductor region. Finally estimated results were discussed and verified through the analytical theory.

  • PDF

Quench development of HTS tapes applied over current with current distribution (과전류 인가 시 고온초전도 선재의 전류 분배에 따른 퀜치 거동)

  • Yim, Seong-Woo;Choi, Yong-Sun;Sim, Jung-Wook;Hwang, Si-Dole;Oh, Je-Myoung;Han, Byoung-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.976-978
    • /
    • 2003
  • Quench characteristics of HTS tapes, which are applied over-current were investigated. When the applied current exceeds the critical current of HTS tapes, the superconductor of HTS tape comes to be changed into normal conductor so that the current begins to flow through the metal sheath, which is made of good electrical conductor. In this study, the current, corresponds to 10 times $I_c$ was fed to HTS tapes. Using the V-I curves and resistance with temperature variation of HTS tapes, the distribution of the applied current between superconductor and metal sheath was analyzed. As the results, we could acquire the duration and magnitude of current to reach to thermal quench.

  • PDF

Magnetic Field Analysis of 1 MVA HTS Transformer Windings

  • Park, Chan-Bae;Kim, Woo-Seok;Lee, Sang-Jin;Han, Jin-Ho;Park, Kyeong-Dal;Joo, Hyeong-Gil;Hong, Gye-Won;Hahn, Song-Yop
    • Progress in Superconductivity and Cryogenics
    • /
    • v.5 no.1
    • /
    • pp.66-70
    • /
    • 2003
  • In a HTS transformer, the perpendicular component of magnetic flux density ($B_r$) applied to HTS tapes of pancake windings becomes larger than that of solenoid winding, thereby decreasing the critical current in the HTS tapes. This paper introduces several methods to reduce $B_r$ applied to the HTS tapes in the transformer with double pancake windings by changing winding arrangements and the relative permeability of flux diverters. We have conducted a winding design for a single-phase 1MVA 22.9kV/6.6kV HTS transformer. We observed a change of $B_r$ due to a variation of gap-length between the high voltage windings and the low voltage windings, reciprocal arrangement and an increase of the number of the high voltage pancake. We also observed a change of Br on the HTS tapes due to variation of the relative permeability of flux diverters placed between the high voltage winding and the low voltage winding. Finally, we have designed a 1MVA 22.9kV/6.6kV HTS transformer winding using suggested methods and calculated transformer parameters by the 3D finite element method.

Improvement of Critical Current In Bi-2223/Ag HTS Tapes by the Bubbling Control

  • 하홍수;오상수;하동우;이남진;김상철
    • Progress in Superconductivity
    • /
    • v.3 no.2
    • /
    • pp.247-251
    • /
    • 2002
  • In general, the bubbling, generated during the fabrication of the tapes, breaks the superconducting filament, and critical current of the tapes will be decreased. Heat-treatment schemes of Bi-2223/Ag HTS tapes were modified, such as pre-annealing of multi-stacked billet, 2-step main sintering and ramp rate etc. The generation of bubbling was drastically decreased from 20 bubbles/m to 0 ~ 1 bubble/m by the modified heat-treatment. Therefore, the value of critical current of the tapes without bubbling was increased almost twice higher than that of already existing tapes. Critical current up to 42 A in 40 m length Bi-22231Ag tapes have been measured at 77K, self-field, 1$mutextrm{V}$/cm criterion. It could be confirmed that elimination of bubbling is effective to maintain the superconducting property along the tape length.

  • PDF

The Magnetization Losses Characteristics of Multi-stacked and Variable Angle of External Magnet Field in YBCO CC and BSCCO tape (YBCO Coated Conducor와 BSCCO tape의 적층 및 외부자장의 각도에 따른 자화손실 특성)

  • Lim, Hyoung-Woo;Lee, Hee-Joon;Cha, Guee-Soo
    • Progress in Superconductivity and Cryogenics
    • /
    • v.7 no.3
    • /
    • pp.34-38
    • /
    • 2005
  • Multi-stacked HTS tapes are needed to conduct large current in the power application. In this paper, magnetization losses of the multi-stacked YBCO coated conductor and the BSCCO tape have been measured and compared. Magnetization losses of single tape, 2-stacked, 3-stacked and 4-stacked HTS tapes have been presented in this paper. Multi-stacked tapes have been fabricated using face-to-face type stacking method. Measurements of magnetization loss were performed under various angle of external magnetic field to consider the anisotropic characteristics of HTS tapes. Test results show that loss density per unit volume decreased for both YBCO coated conductors and BSCCO tapes when the stacking number of tapes is increased. The magnetization losses of YBCO CC are larger than those of BSCCO tapes when the external magnetic field is increased.

Comparison Magnetization Losses of the multi-stacked YBCO Coated conductor and the BSCCO tapes (YBCO CC와 BSCCO Tape의 적층에 따른 자화손실 특성비교)

  • Lim Hyoungwoo;Lee Heejoon;Cha Gueesoo;Lee Ji-Kwang
    • Progress in Superconductivity and Cryogenics
    • /
    • v.7 no.3
    • /
    • pp.13-16
    • /
    • 2005
  • Multi-stacked HTS tapes are needed to conduct large current in the power application. In this paper magnetization losses of the multi-stacked YBCO coated conductor and the BSCCO tape have been measured and compared. Magnetization losses of single tape, 2-stacked, 3-stacked and 4-stacked HTS tapes have been presented in this paper. Multi-stacked tapes have been fabricated using face-to-face type stacking method. Measurements of magnetization loss were performed under various stacked of external magnetic field to consider the anisotropic characteristics of HTS tapes. Test results show that loss density per unit volume decreased for both YBCO coated conductors and BSCCO tapes when the stacking number of tapes is increased. As the external magnetic field decreased, the ratio of decrement has risen because the full penetration magnetic field(Bp) of the multi-stacked tape is larger than that of the single tape.

Assembling and Insulation Test of 1MVA Single Phase HTS Transformer for Power Distribution

  • Kim, S. H.;Kim, W. S.;Kim, J. T.;Park, K. D.;H. G. Joo;G. W. Hong;J. H. Han;Lee, S. J.;S. Hahn
    • Progress in Superconductivity and Cryogenics
    • /
    • v.5 no.3
    • /
    • pp.30-33
    • /
    • 2003
  • 1MVA high temperature superconducting (HTS) transformer with double pancake windings made of BSCCO-2223 HTS tapes was designed and manufactured. And prototype transformer with the same capacity was manufactured also. The each rated voltage of the HTS transformer is 22.9 kV and 6.6 kV. Four parallel BSCCO-2223 HTS tapes were wound in the double pancake windings of low voltage side. In order to distribute the currents equally in each HTS tapes, the three times transposition was performed between the double pancake windings. The windings of prototype transformer were wound using copper tape with the same size as BSCCO-2223 HTS tape. The core of the transformer was designed and manufactured as a shell type core made of laminated silicon steel plate. The several characteristics tests for the prototype transformer were performed in liquid nitrogen and insulation tests were accomplished also.

I-V Characteristics of HTS Conductors with Joints (고온초전도 접합도체들의 I-V 특성에 관한 연구)

  • Sohn, Hyung-Hwan;Min, Chi-Hyun;Lee, Eon-Yong;Sim, Ki-Deok;Kim, Seok-Ho;Seong, Ki-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.679-680
    • /
    • 2006
  • Various different types of joining between High Tc superconducting(HTS) tapes were prepared and current-voltage(I-V) characteristic curves were investigated at 77 K, liquid nitrogen temperature. Two typos of HTS tapes wore used, one is no laminated tape(Sumitomo high strength type tape) and the other stainless steel laminated tape(AMSC(American Superconductors Inc.) 3ply tapes) Sample joints were lap-jointed with indium or solder. Joint resistances between Sumitomo tapes with 4-10 mm in length were estimated from I-V curves and in the range of $4-8n{\Omega}$ at 77 K. Joint resistances of AMSC tapes were in the range of $140-170n{\Omega}$, much higher than them of Sumitomo samples. The n-values of jointed HTS tapes were 50% of them with no joint. In AMSC tapes, indium is better than solder as the jointing material.

  • PDF

Study on the Stability Evaluation of the High-Tc Superconducting Power Cable (고온초전도 전력케이블의 안정도 평가를 위한 교류손실에 관한 연구)

  • Bae, J.H.;Choi, S.J.;Lee, S.J.;Cho, J.W.
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.7
    • /
    • pp.1236-1240
    • /
    • 2007
  • In order to evaluate if the high-Tc superconducting(HTS) power cable is operating stably, the characteristics of the HTS power cable should be found out. The properties of HTS tapes by measuring the voltage with respect to the current can be archived. But, the HTS power cable is different from the case of HTS tapes. This method is invalid because of the electromagnetic fields caused by other HTS tapes. In this paper, the stability evaluation of the HTS cable was performed by the following procedure. First, the voltage-current characteristics of HTS tape were measured and the electromagnetic field distributions of the HTS power cable with the external magnetic field were analyzed. Second, the losses of the HTS power cable were calculated using the result of the measurement and the analysis. Finally, the stable operation of the HTS power cable was evaluated on the basis of the losses of the superconducting cable.