• 제목/요약/키워드: HTS(High Temperature Superconducting) Cable

검색결과 123건 처리시간 0.027초

한전 초전도전력케이블 냉각시스템 성능시험 (Performance Test of Cooling System for the KEPCO HTS Power Cable)

  • 양형석;김동락;손송호;임지현;최하옥;이병섭;최연석;류희석;황시돌
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2206-2210
    • /
    • 2007
  • As a power transmission line supplying power to a densely populated city, the high temperature superconducting (HTS) cable is expected to one of the most effective cables with a compact size because of its high current density. The verification of HTS power cable system have been progressed by KEPRI. A cooling system for a 3-phase 100m HTS power cable with 22.9kV/1.25kA was installed and tested at KEPCO's Gochang power testing center in Korea. The system consists of a liquid nitrogen decompression cooling system with a cooling capacity of 3kW and a closed circulation system of subcooled liquid nitrogen. Several performance tests of the cable system with respect to the cooling such as cooling capacity, heat load and temperature stability, were performed at several temperatures. Thermal cycle test, cool-down to liquid nitrogen temperature and warm-up to room temperature, was also performed to investigate thermal cycle influences. The outline of the installed cooling system and performance test results are presented in this paper.

  • PDF

Investigation on Effective Operational Temperature of HTS Cable System considering Critical Current and AC loss

  • Kim, Tae-Min;Yim, Seong-Woo;Sohn, Song-Ho;Lim, Ji-Hyun;Han, Sang-Chul;Ryu, Kyung-Woo;Yang, Hyung-Suk
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제2권2호
    • /
    • pp.307-310
    • /
    • 2016
  • The operational cost for maintaining the superconductivity of high-temperature superconducting (HTS) cables needs to be reduced for feasible operation. It depends on factors such as AC loss and heat transfer from the outside. Effective operation requires design optimization and suitable operational conditions. Generally, it is known that critical currents increase and AC losses decrease as the operational temperature of liquid nitrogen ($LN_2$) is lowered. However, the cryo-cooler consumes more power to lower the temperature. To determine the effective operational temperature of the HTS cable while considering the critical current and AC loss, critical currents of the HTS cable conductor were measured under various temperature conditions using sub-cooled $LN_2$ by Stirling cryo-cooler. Next, AC losses were measured under the same conditions and their variations were analyzed. We used the results to select suitable operating conditions while considering the cryo-cooler's power consumption. We then recommended the effective operating temperature for the HTS cable system installed in an actual power grid in KEPCO's 154/22.9 kV transformer substation.

Test result of striated HTS compact cables for low AC loss

  • Kim, Y.;Kim, W.S.;Lee, J.K.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제15권2호
    • /
    • pp.44-47
    • /
    • 2013
  • Large AC loss from the second generation (2G) high temperature superconducting (HTS) wires has been one of the major bottlenecks in power applications with HTS materials. Moreover, the large power applications also require the large current capacity from the HTS wires, which makes them produce larger AC losses. In order to reduce the AC loss from the HTS conductors with large current capacity, an HTS compact cable with some striations on the superconducting layers has been proposed. In this paper, we prepared some sample HTS compact conductors with striations, and measured their magnetization loss from the external magnetic field. We also made some slits on the superconducting layer of the HTS wire by laser cutting to reduce the aspect ratio of the superconducting layers. It would make the low eddy current loss and magnetic decoupling. Finally, the magnetization losses of the sample HTS compact conductors were measured and analyzed.

Review of the Conceptual Design for the Use of HTS Power Transmission Cable for a Metropolitan Area

  • Park, Sang-Bong
    • KIEE International Transactions on Power Engineering
    • /
    • 제3A권2호
    • /
    • pp.63-69
    • /
    • 2003
  • The necessity of compact high temperature superconducting cables is more keenly felt in densely populated metropolitan areas. Because the compact high-temperature superconducting cables can be installed in ducts and tunnels, thereby reducing construction costs and making the use of underground space more effective, the effect of introducing it to the power system will be huge. Seoul, Korea, is selected as a review model for this paper. The loads are estimated by scenario based on a survey and analysis of 345kV and 154kV power supply networks in this area. Based on this, the following elements for an urban transmission system are examined. (1) A method of constructing a model system to introduce high-temperature superconducting cables to metropolitan areas is presented. (2) A case study is conducted through the analysis of power demand scenarios, and the amount of high-temperature superconducting cable to be introduced by scenario is examined. (3) The economy involved in expanding existing cables and introducing high-temperature superconducting cables(ducts or tunnels) following load increase in urban areas is examined and compared., and standards for current cable ducts are calculated. (4) The voltage level that can be accommodated by existing ducts is examined.

Bi-2223 고온초전도선의 과전류 통전특성 (Characterisitics of the over current of Bi-2223 HTS tape)

  • 김재호;심기덕;조전욱;김해준;곽동순;성기철;김해종
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 하계학술대회 논문집 Vol.6
    • /
    • pp.284-285
    • /
    • 2005
  • Bi-2223 High-Temperature Superconducting(HTS) tape is one of the most widely used HTS tape for power application. Characteristics of the over current of HTS tape with different sheath are described. This paper presents the basic properties such as temperature and resistivity rise of the Bi-2223 HTS tape which is exposed to the over current. It is expected that results from this study can be utilized as basic data in designing superconducting power devices.

  • PDF

단층 초전도케이블 샘플에서 교류손실의 수치해석에 대한 연구 (A Study on Numerical Analysis of the AC Loss in a Single-layer Superconducting Cable Sample)

  • 이주영;마용호;류경우;황시돌
    • 한국전기전자재료학회논문지
    • /
    • 제22권7호
    • /
    • pp.606-611
    • /
    • 2009
  • AC loss is one of the important factors for commercialization of a high temperature superconducting (HTS) cable from an economic point of view. But AC loss characteristics of the HTS-cable are not elucidated completely because of its complex structure. As an earlier stage of analyzing the AC loss in the 22.9 kV/50 MVA, 100m HTS-cable system of Korea Electric Power Corporation (KEPCO) which is now in collaboration with us, a two-dimensional (2D) numerical model, which takes into account the nonlinear conductivity properties of a high temperature superconductor, has been developed. In order to examine our 2D model, we have prepared several single-layer cable samples whose AC losses are sufficiently reliable due to their simple structure. The AC losses of the samples were experimentally investigated and then compared with our 2D model. The results show that the numerically calculated AC losses are not in good agreement with the measured ones for the cylindrical cable and deca-cable samples with low critical current density. However, the numerically calculated and measured AC losses are relatively in good agreement for the deca-cable and hex-cable samples with high critical current density, although the difference between these two loss data in the deca-cable sample tends to increase in the low current region.

고온초전도 케이블의 절연파괴 특성에 미치는 Butt gap의 영향 (Effect of Butt Gap in the Electrical Breakdown Properties of a HTS Cable)

  • 곽동순;김영석;김해종;조전욱;김상현
    • 한국전기전자재료학회논문지
    • /
    • 제17권3호
    • /
    • pp.333-339
    • /
    • 2004
  • For an electrical insulation design of HTS cable, it is important to understand the dielectric characteristics of insulation materials in L$N_2$ and the insulation type. Generally, the electrical insulation of HTS Cable is classified into two types of the composite insulation and solid insulation type. In this research, we selected the insulation paper/L$N_2$ composite insulation type for the electric insulation of a HTS cable, and studied electric insulation characteristics of synthetic Laminated Polypropylene Paper(LPP) in liquid nitrogen(L$N_2$) for the application to high temperature superconducting(HTS) cable. Furthermore, we compared the breakdown characteristics of the butt gap and bended mini-model cable. It is necessary to understand the winding parameter of insulation paper/LN2 composite insulation.

22.9kV 초전도케이블 시스템의 신뢰성 평가 (Reliability Assesment of 22.9kV High Temperature Superconducting Cable System)

  • 손송호;임지현;성태현;류희석;양형석;김동락;황시돌
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 하계학술대회 논문집 Vol.8
    • /
    • pp.248-248
    • /
    • 2007
  • Demands for electricity are growing, whereas the rate of electricity infrastructure's construction declines gradually. To keep the balance of the demand and supply, the share of underground transmission line will be increased from 8.3% to 10.5% in 2020 but it will be accompanied with enormous public expenses. A great concern in high capacity transmission is on the increase so as to maximize the spacial efficiency. High Temperature Superconducting (HTS) cable is in the lime light which has the merits of environment-friendly, low transmission loss and high transmission with low voltage, but the reliability verification as a power system is yet to be solved. KEPCO completed the installation and acceptance of $3{\phi}$, 22.9kV, 1250A class HTS cable system in 2006 and the long term test is in progress. The test results focusing on long term reliability are presented in this paper.

  • PDF

154 kV급 고온초전도 케이블 및 단말의 전기절연 설계 (Electrical Insulation Design of a 154 kV Class HTS Cable and Termination)

  • 곽동순;천현권;최재형;김해종;조전욱;김상현
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제9권1호
    • /
    • pp.61-66
    • /
    • 2007
  • A transmission class high-temperature superconducting(HTS) power cable system is being developed in Korea. For insulation design of this cable the grading method of insulating paper is proposed. Two kinds of laminated polypropylene paper that has different thickness has been used as the electrical insulation material. The use of graded insulation gives improved mechanical bending properties of the cable. In a HTS cable technology the terminations are important components. A HTS cable termination is energized with the line-to-ground voltage between the coaxial center and outer surrounding conductors. in the axial direction. There is also a temperature difference from ambient to about 77 K. For insulation design of this termination, glass fiber reinforced plastic(GFRP) was used as the insulation material of the termination body, and the capacitance-graded method is proposed. This paper will report on the experimental investigations on impulse breakdown and surface flashover characteristics of the insulation materials for insulation design of a transmission class HTS power cable and termination. Based on these experimental data, the electrical insulation design of a transmission class HTS power cable and termination was carried out.

22.9 kV 초전도케이블 시스템의 통전특성 (Current Transport Characteristics of 22.9 kV High Temperature Superconducting Cable System)

  • 손송호;임지현;류희석;양형석;최하옥;마용호;김동락;류경우;성태현;현옥배;임성우;황시돌
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.398-399
    • /
    • 2008
  • Enhanced performances of high temperature superconducting (HTS) cable attract tremendous interests of the power utility. However, the reliability issue as the power system is still in controversy. To verify the reliability of HTS cable, 22.9 kV HTS cable system with the specification of 100 m length, 50 MVA capacity, and open refrigeration cooling system was laid on Gochang power testing center of KEPCO in 2006. During the test period, the current transport characteristics, the fundamental function of power cable, have been monitored and investigated precisely. In this paper, the heat loss and AC loss measured at various current load conditions are described and discussed.

  • PDF