The Evaluation of the Axial Strength of Composite Column with HSA800 Grade Steel (HSA800 강재를 적용한 합성기둥의 축방향 내력 평가)

  • Lee, Myung Jae;Kim, Cheol Hwan;Kim, Hee Dong
    • Journal of Korean Society of Steel Construction
    • /
    • v.26 no.5
    • /
    • pp.473-483
    • /
    • 2014
  • According to the Korean Building Code (KBC), the validity of the application of 800MPa grade steel(HSA800) to composite column should be verified by experimental or analytical method. Thus, stub column tests for encased and filled composite members with HSA800 steel were conducted, and axial strength and the validity of design compressive strength equations in KBC were evaluated. The test results show that the equation of the compressive strength of encased composite column member in KBC should be modified in order to use HSA800 steel without any reduction of specified minimum yield strength. For this purpose, it is suggested that the interval of hoop should be narrowed and the effective concrete area should be used. The equation of the compressive strength of filled composite column member in KBC is applicable to filled composite column with HSA800 steel without any modification.

A Study on the Material Characteristics of the HSA800 Steel and Homogeneity of Strength (HSA800 강재의 소재특성 및 강도의 균질성에 관한 연구)

  • Kim, Jong Rak;Lee, Eun Taik;Choi, Young Han;Kim, Sang Seup
    • Journal of Korean Society of Steel Construction
    • /
    • v.28 no.3
    • /
    • pp.173-183
    • /
    • 2016
  • Various material characteristics of HSA800 steel were examined and a quantitative criteria about the homogeneity of the strength was proposed. Whether HSA800 steel is satisfied the criteria for homogeneity of the strength or not was also examined. From the test results, the material characteristics of 1/4 point from the extreme fiber in the Z-direction satisfied the KS requirements. The excellent directional properties and impact resistance at low temperatures were also showed from the test results. HSA800 steel satisfied the criteria of homogeneity for the strength of the steel. However, it showed that some structures were banded together at 2/4 point from extreme fiber in the Z-direction from the microscopic tests and attention is needed to be paid in that point.

A Study for the Weldability, Welding Position and Welded Joint Performance on the FCAW of HSA800 Steel (HSA800 강재의 FCAW 용접성, 용접자세 및 이음성능 연구)

  • Lee, Eun Taik;Kim, Jong Rak;Choi, Young Han;Kim, Sang Seup
    • Journal of Korean Society of Steel Construction
    • /
    • v.28 no.4
    • /
    • pp.281-292
    • /
    • 2016
  • In this research, 10 specimens of FCAW welding with positions of 1G and 3G were tested to confirm the weldability, welding positions, and welded joint performance of 60mm HSA800 steel. The test results showed that FCAW 1G and 3G satisfied HSA800 steel's KS and the criteria for homogeneity of strength, indicating a good weld zones. However, according to the tensile test results of weld zone, 3G position FCAW welding requires improvement of welding techniques and methods.

Application Study of High-Strength Steel(HSA800) for the Special Structure (특수구조 대상으로 고강도 강재(HSA800)의 현장 적용성 연구)

  • Kim, In-Ho;Lee, Hee-Su;Park, Sung-Yong;Kim, Jong-Soo
    • Journal of Korean Association for Spatial Structures
    • /
    • v.14 no.2
    • /
    • pp.69-78
    • /
    • 2014
  • The purpose of this study is to increase applicability of high strength steel, HSA800 to the structure. Selected study of structure is to consider high strength steel, and following parts, 1) Tensile member with no consider of buckling, 2) Truss existing both tension and compression members with small slenderness ratio. This studied structure is included tension column hang on to the upper bridge truss. The structure element quantity with apply HSA800 instead of SM570 is reduced about 38.9% of tension column and 29.7% of bridge truss. In addition, the number of element's division is reduced about two sections due to reduction of self weight that the crane is able to lift up. This improves to reduce erection sequence and construction period which can save about a month. All connections are reviewed as welding and bolt. Also, the cost of welding is reduced about 41.3% due to apply HSA800. In conclusion, applying HSA800 to the hanging structure aggressively can secure economic and constructability.

Evaluation of Applicability on a High-rise Building for the Effective Usage of High Performance Steel for Building Structures (건축구조용 고성능 강재 HSA800의 효율적 사용을 위한 초고층 건물의 적용성 평가)

  • Kim, Do Hwan;Kim, Joo Woo;Lee, Dong Woo;Yang, Jae Guen;Lee, Myung Jae
    • Journal of Korean Society of Steel Construction
    • /
    • v.26 no.5
    • /
    • pp.463-471
    • /
    • 2014
  • As building height and span is getting taller and longer, the researches to increase material's strength and serviceability are continuously performed. This study evaluated mechanical and chemical properties of newly developed high-strength steel (HSS) for building structures, namely HSA800 and verified cost-effectiveness and applicability of HSS for a tall building by comparing the analysis results of normal strength steel (SM490) model. HSA800 was manufactured by TMCP to have a good weldability in spite of HSS and satisfied Korean Industrial Standards (KS). The analysis results for evaluating cost-effectiveness show that total steel quantity could be saved approximately 30% when using HSS compared to SM490. It is expected that HSA800 will contribute to enhance constructability of building.

A Study for the Weldability and Welded Joint Performance on the SAW of HSA800 Steel (HSA800 강재의 SAW 용접성 및 이음성능 연구)

  • Choi, Young Han;Kim, Sang Seup
    • Journal of Korean Society of Steel Construction
    • /
    • v.29 no.1
    • /
    • pp.37-48
    • /
    • 2017
  • In this research, 9 SAW welding specimens with 1 hour post-heat treatment (PH1) and 2 hours (PH2) were experimented to confirm the weldability and the joint performance of 60mm thickness HSA800 steel. SAW tests with PH1 & PH2, including weld impact test, bend test, hardness test, macroscopic test, and microscopic test, had a good test results. However, from the chemical composition test results, P composition was not satisfied with Korean Industrial Standards(KS). According to the weld-zone tensile tests, 2 hours post-heat SAW is recommended because the mechanical characteristics of SAW PH2 were better than those of SAW PH1.

Flexural Tensile Strength of CJP Groove Welded Joints Connecting Thick HSA800 Plates (HSA800 후판재의 완전용입 맞댐용접부 휨-인장강도 실험)

  • Lee, Cheol Ho;Kim, Dae Kyung;Han, Kyu Hong;Park, Chang Hee;Kim, Jin Ho;Lee, Seung Eun;Kim, Do Hwan
    • Journal of Korean Society of Steel Construction
    • /
    • v.26 no.5
    • /
    • pp.407-418
    • /
    • 2014
  • As a continuing work of previously conducted standard tension tests, full-scale flexural tests were conducted in this study to assess the structural performance the CJP groove welded joints connecting thick HSA800 plates. Two welding electrodes were available at the time of this experimental research; one was GMAW-based electrode A and the other FCAW-based electrode B. Three full-scale box-type beam specimens with single bevel- and V-groove CJP welded joints were fabricated from 60mm and 25mm thick HSA800 plates according to the AWS-prequalified groove welded joint details. In designing the specimens, all possible limit states like local and lateral torsional buckling were carefully controlled in order to induce flexural plastic yielding or eventual joint fracture. All the CJP joints made by both welding electrodes showed satisfactory performance and were able to transfer the tensile flange forces higher than that corresponding to the measured tensile strength of HSA800 flange plates. However, it should be noted that, during fabrication, serious concerns about the welding efficiency and workability of the GMAW-based electrode were raised by a certified welder. The fracture occurred at the unbeveled (or vertical) interface between the weldment and the base metal when the GMAW-based electrode was used in the single-bevel joint, implying the possibility of insufficient melting. Thus, the FCAW-based electrode B is again recommended as the choice of welding electrode for HSA800 plates. The limited test data of this study implies that the V-groove CJP joint should be used in favor of the single bevel CJP joint, if possible.

Buckling Strength of Concentrically Loaded High-Strength Steel Columns with Intermediate Slenderness (중심압축을 받는 고강도강 중간주의 좌굴강도 평가)

  • Kim, Dae Kyung;Lee, Cheol Ho;Han, Kyu Hong;Kim, Jin Ho;Lee, Seung Eun;Kim, Jin Won
    • Journal of Korean Society of Steel Construction
    • /
    • v.27 no.4
    • /
    • pp.377-386
    • /
    • 2015
  • In this study, inelastic buckling strength of HSA800 steel columns were tested to investigate the applicability of current column curve (KBC2009, 2010 AISC-LRFD) to HSA800 steel. Key test variables included width-thickness ratio, plate-edge restraints, and column slenderness ratio. Specimens made of ordinary steel (SM490) were also tested for comparison purposes. All the concentrically loaded HSA800 specimens exhibited sufficient buckling strength compared to the current column curve, but some of SM490 specimens showed understrength. This difference can be explained by the lower residual stress present in HSA800 specimens.