• Title/Summary/Keyword: HPLC-fluorescence detector (HPLC-FLD)

Search Result 29, Processing Time 0.032 seconds

Application of Competitive ELISA Method for Estimation of Urinary Aflatoxin M1 Level (ELISA 방법을 이용한 요중 아플라톡신 M1 측정)

  • Kim, Yong-Dae;Kim, Heon
    • Journal of Life Science
    • /
    • v.23 no.2
    • /
    • pp.306-310
    • /
    • 2013
  • We compared the efficacy of the competitive ELISA method for measuring the level of urinary aflatoxin M1 (AFM1) with that of the HPLC-fluorescence detector (HPLC-FLD) method. The recovery rate of AFM1 with the ELISA method was 105% (73-124%), and the coefficient of variation of the analysis was 6.85%. The ELISA method showed a 0.20 pg/ml and 0.62 pg/ml limit of detection and limit of quantitation, respectively. In correlation analysis, the two methods showed a very strong and statistically significant correlation (R=0.96, p<0.01). However, in spite of the strong correlation, the ELISA method tended to overestimate the urinary AFM1 concentration compared to the HPLC-FLD method. These results suggest that the competitive ELISA method may be a useful technique for measuring the AFM1 level in high-throughput urine samples, but it needs to be corrected with a regression equation from regression analysis with the HPLC-FLD method.

Development of Analytical Methods for Micro Levels of Naphthalene and TNT in Groundwater by HPLC-FLD and MSD (HPLC-FLD와 MSD를 이용한 지하수 중 나프탈렌 및 TNT의 미량 분석법 개발)

  • Park, Jong-Sung;Oh, Je-Ill;Jeong, Sang-Jo;Choi, Yoon-Dae;Her, Nam-Guk
    • Journal of Soil and Groundwater Environment
    • /
    • v.14 no.6
    • /
    • pp.35-44
    • /
    • 2009
  • Naphthalene and TNT (2,4,6-trinitrotoluene) are defined by U.S. EPA as possible carcinogenic compounds known to have detrimental effects on the aquatic ecosystem and human body. There are, however, few researches on methods of analyzing micro-levels of naphthalene and TNT dissolved in groundwater. This study introduces and evaluates the newly developed analytical methods of measuring naphthalene and TNT in groundwater by using HPLC-FLD (Fluorescence detector) and MSD (Mass detector). The MDL, LOQ and salt effect of these methods, respectively, are compared with those of conventional methods which use HPLC-UV. For the analysis of naphthalene, HPLC-FLD was set in the maxima wavelength (Ex: 270 nM, Em: 330 nM) obtained from 3D-Fluorescence to be compared with HPLC-UV in 266 nM wavelength. The MDL ($0.3\;{\mu}g/L$) and LOQ ($2.0\;{\mu}g/L$) of naphthalene by using HPLC-FLD were approximately 80 times lower than those analyzed by HPLC-UV (MDL: $23.3\;{\mu}g/L$, LOQ: $163.1\;{\mu}g/L$). HPLC-MSD were used in comparison with HPLC-UV in 230 and 254 nM wavelength for the analysis of TNT. The MDL ($0.13\;{\mu}g/L$) and LOQ ($0.88\;{\mu}g/L$) of TNT analyzed by using HPLC-MSD were approximately 130 times lower than those obtained by using HPLC-UV in 230 nM (MDL: $16.8\;{\mu}g/L$, LOQ: $117.5\;{\mu}g/L$). The chromatogram of TNT analyzed by using HPLC-UV in 230 nM displayed elevated baseline as the concentration of ${NO_3}^-$ increases beyond 21 mg/L, while the analysis using HPLC-MSD did not demonstrate any change in baseline in presence of ${NO_3}^-$ of 63.7 mg/L which is 3.5 times higher than average concentration in groundwater. In conclusion, HPLC-FLD and HPLC-MSD may be used as suitable methods for the analysis of naphthalene and TNT in groundwater and drinking water. These methods can be applied to the monitoring of naphthalene and TNT concentration in groundwater or drinking water.

Measurement of Total Plasma Homocysteine in Patients with Chronic Renal Failure Using HPLC/FLD (만성신부전증환자에서 HPLC/FLD를 이용한 혈장 Homocysteine의 측정)

  • Kyung-Ok Lee;Bo-Kyung Kang;Hyung-Jin Roh;Kwang-Suk Ryoo;Jeong-Yeon Yoo;Man-Jeong Paik;Kang-Hyeob Lee
    • Biomedical Science Letters
    • /
    • v.3 no.1
    • /
    • pp.29-35
    • /
    • 1997
  • Cardiovascular disease has been the leading cause of death among patients with chronic renal failure. Many reports have been described that homocysteine is one of the independent risk factor to the occulsive vascular disease. In this study, HPLC/FLD (high performance liquid chromatography-fluorescence detector) technique was used to measure homocysteine level in patients with chronic renal failure and normal control group. The detection limit and recovery of total plasma homocysteine using HPLC/FLD were 98.6$\pm$5.8% and 0.2 nmol/ml, respectively. The linearity of this method was established in concentration range of 2~50 nmol/ml (correlation coefficient=0.9997). The concentrations of total plasma homocysteine were 6.81$\pm$1.54 nmol/ml and 27.28$\pm$14.94 nmol/ml in normal control (n=20) and patient group (n=90), respectively (p<0.05). In this study, the HPLC/FLD method showed high sensitivity and reproducibility for a routine clinical laboratory testing. Moreover determination of homocysteine level in plasma might be useful for a biochemical marker for predicting the cardiovascular diseases and for monitoring of therapeutic effect of lowering homocysteine in patients with chronic renal failure.

  • PDF

Determination of Glutathione in Biological Samples by Ion-pairing HPLC/FLD (이온쌍 HPLC/FLD를 이용한 생체 시료중의 Glutathione 농도 분석)

  • Yoo, Jeong-Yeon;Lee, Kyoung-Ok;Shin, Ho-Sang
    • Analytical Science and Technology
    • /
    • v.12 no.1
    • /
    • pp.28-33
    • /
    • 1999
  • Glutathione(GSH) in biological samples was determined by high performance liquid chromatographic(HPLC) method with fluorescence detector(FLD) after monobromobimane(MBB) or 4-fluoro-7-sulfobenzofurazan(SBD-F) derivatization. The detection limit of $0.03{\mu}g/mL$ was obtained after MBB derivatization, derivative of MBB was about 200 times more sensitive than that of SBD-F. N-acetylcysteine was used as internal standard and tetrabutylammonium ion as counter ion for better separation. The determination by ion-pairing chromatography after MBB derivatization was characterized by linearity in the range between $0.08{\sim}8.33{\mu}g/mL$ with a good correlation coefficient of 0.998. By precision test appeared relative standard deviation at less than 5% at three different concentrations. This method can be used for the analysis of GSH in plasma and tissue.

  • PDF

A Survey of Total Aflatoxins in Food Using High Performance Liquid Chromatography-Fluorescence Detector (HPLC-FLD) and Liquid Chromatography Tandem Mass Spectrometry(LC-MS/MS) (HPLC-FLD 및 LC-MS/MS에 의한 식품 중 총아플라톡신 오염실태 조사)

  • Jang, Mi-Ran;Lee, Chang-Hee;Cho, Sung-Hye;Park, Joon-Shik;Kwon, Eun-Young;Lee, Eun-Jin;Kim, So-Hee;Kim, Dai-Byung
    • Korean Journal of Food Science and Technology
    • /
    • v.39 no.5
    • /
    • pp.488-493
    • /
    • 2007
  • A survey for total aflatoxins (aflatoxins $B_1$, $B_2$, $G_1$, and $G_2$) was conducted on 245 cereals and processed cereal products, and 148 nuts and processed nut products in Korea, for a total of 393 commercialized ed samples. The total aflatoxins were quantified by the immunoaffinity column clean-up method with high performance liquid chromatography (HPLC) - fluorescence detection (FLD), and were confirmed by liquid chromatography tandem mass spectrometry (LC-MS/MS). Total aflatoxins(AFs) were detected in 37 samples (9.4% incidence), including 2 millet samples, 1 mixed cereal (sunsik), 1 powdered malt sample, 2 processed cereal products, 6 peanut samples, 22 peanut butter samples, and 1 sample each of almonds, adlay tea, and a processed nut product. The contamination levels were $0.04-2.65{\mu}g/kg$ for aflatoxin $B_1$, and $0.04-5.51{\mu}g/kg$ for total aflatoxins. Finally, LC-MS/MS analysis of the contaminated samples was conducted to confirm the detected aflatoxins, and all 37 samples showing aflatoxins by HPLC-FLD were confirmed by LC-MS/MS.

A Survey of Zearalenone in Beans Using High Performance Liquid Chromatography-Fluorescence Detector (HPLC-FLD) and Ultra Performance Liquid Chromatography Tandem Mass Spectrometry (LC-MS/MS) (HPLC-FLD 및 LC-MS/MS에 의한 두류 중 제랄레논 오염실태 조사)

  • Jang, Mi-Ran;Lee, Chang-Hui;Lee, Hyo-Jeong;Kim, Ji-Yeon;Son, Sang-Hyeok;Sin, Chun-Sik;Kim, So-Hui;Kim, Dae-Byeong
    • Korean Journal of Food Science and Technology
    • /
    • v.40 no.3
    • /
    • pp.354-359
    • /
    • 2008
  • A survey for zearalenone contamination was conducted on 27 soy bean samples, 27 red bean samples, 16 black bean samples, 19 seoritae samples, 14 seomoktae samples, for a total of 127 commercial Korean samples. Zearalenone was quantified by the immunoaffinity column clean-up method with high performance liquid chromatography-fluorescence detection (HPLC-FLD), and was confirmed by liquid chromatography tandem mass spectrometry(LC-MS/MS). The limits of detection and quantification were $2.0{\mu}g/kg$ and $6.0{\mu}g/kg$, respectively. The recovery in the beans ranged from 82.2 to 98.4%. According to HPLC-FLD, zearalenone was detected in 13 samples (10.2% incidence), including 1 soybean and 12 red bean samples. The zearalenone contamination levels were in the range of 8.01${\sim}38.98{\mu}g/kg$. Finally, LC-MS/MS analysis was conducted in the contaminated samples to verify the results of HPLC-FLD. The LC-MS/MS results confirmed the presence of zearalenone in all 13 samples. The contamination level was lower than that of EU, which is below $100{\mu}g/kg$ for raw grains.

Multiresidue Determination of Quinolones in Porcine, Chicken, and Bovine Muscle Using Liquid Chromatography with Fluorescence Detection

  • Lee, Sang-Hee;Shim, You-Sin;Kim, Hyun-Ju;Shin, Dong-Bin
    • Food Science and Biotechnology
    • /
    • v.18 no.4
    • /
    • pp.978-984
    • /
    • 2009
  • An analytical method for the simultaneous determination of 9 quinolones (QNs) in porcine, chicken, and bovine muscles was developed and validated using liquid chromatography-fluorescence detector (LC-FLD). The samples were extracted using a liquid-liquid extraction (LLE) process. Chromatographic separation was achieved on a reverse phase $C_8$ column with a gradient elution using a mobile phase of 200 mM ammonium acetate buffer (pH 4.5) and acetonitrile (ACN). The proposed method was validated according to the Food and Drug Administration (FDA) guideline for bioanalytical assay procedures. Recoveries of QNs were 83.1-111.9% with relative standard deviations (RSDs) below 15%. Linearity within a range of 30-500 ${\mu}g/kg$ was obtained with the correlation coefficient ($R^2$) of 0.9967-0.9999. The limits of detection (LOD) were 1-16 ${\mu}g/kg$. These values were lower than the maximum residues limits (MRLs) established by the European Union (EU). The present method was successfully applied to determine QNs in edible muscles.

Pretreatment of Fish for the determination of polycyclic aromatic hydrocarbons using alkali digestion (알칼리분해를 이용한 어류 중 다환방향족탄화수소의 전처리방법)

  • Hu, Soojung;Lee, Hyomin;Chae, Youngzoo;Yoo, Eun-Ah
    • Analytical Science and Technology
    • /
    • v.18 no.5
    • /
    • pp.403-409
    • /
    • 2005
  • Polycyclic Aromatic Hydrocarbons(PAHs) contamination arises from several sources including processing of food(smoking, direct drying, cooking) and environmental contamination of air, water, or soil, the later being considered as the most important. In this study, to establish the analytical method for some PAHs[benzo(a)anthracene, chrysene, benzo(b)fluoranthene, benzo(k)fluoranthene, benzo(a)pyrene, dibenzo(a,h)anthracene, benzo(g,h,i)perylene, indeno(1,2,3-c,d)pyrene] in fish, alkali digestion time, extraction solvents, elution volume of florisil cartridge for clean-up have been optimized. The methodology involved saponification and extraction with n-hexane, clean-up on Sep-Pak florisil cartridges and determination by HPLC/FLD(High Performance Liquid Chromatography/Fluorescence Detector). Overall method recoveries for 8 PAHs spiked into these products ranged from 90 to 106%.

Analysis of Benzo(a)pyrene in Red Ginseng Beverage (홍삼음료 증 벤조피렌 분석)

  • Hu, Soo-Jung;Jin, Sun-Hee;Choi, Dong-Mi
    • Journal of Food Hygiene and Safety
    • /
    • v.23 no.1
    • /
    • pp.26-30
    • /
    • 2008
  • Polycyclic Aromatic Hydrocarbons(PAHs) contamination arises from several source including processing of food(smoking, direct drying, cooking) and environmental contamination of air, water or soil. A red ginseng is produced by steaming the root followed by drying. The methodology involved extraction with n-hexane and washing with water, clean-up on Sep-Pak Florisil Cartridges and determination by HPLC/FLD. The mobile phase was a mixture of acetonitrile and water in 8:2 by the isocratic elution and the excitation wavelength of fluorescence detector was 294 nm and its emission wavelength was 404 nm. The average recovery was about 105% and the relative standard deviation was 0.5. The levels of benzopyrene in the selected red ginseng beverage samples were not detected.

Study on Decomposition of Several Pesticides by Gamma-Irradiation (감마선 조사에 의한 농약 성분의 분해 연구)

  • Lee, Joo-Sang;Jung, Su-Yeon;Oh, Seung-Yeol;Jang, Beom-Su;Park, Sang Hyun
    • Journal of Radiation Industry
    • /
    • v.6 no.3
    • /
    • pp.205-209
    • /
    • 2012
  • The decomposition of 50 pesticides present in an aqueous solution using ${\gamma}-irradiation$ from a $^{60}Co$ gamma-ray source was investigated using laboratory-scale experiment. The rates of decomposition were determined using a gas chromatography-electron capture detector (GC-ECD), high-performance liquid chromatography-photo diode array detector (HPLC-PDA), and HPLC-fluorescence detector (FLD). When the initial concentration of pesticides was 10 ppm, and the radiation dose was 2, 5, 10, 20, and 30 kGy, respectively, 14 pesticide samples showed high removal rates (>50%) at absorbed doses of more than 10 kGy. With the exception of procymidone, they were all completely removed at a 30 kGy irradiation dose. These results provide fundamental data on the reactivity between gamma-irradiation and pesticides in an aqueous solution. Further, an evaluation of the toxicity of radiolytic intermediate products is required.