• Title/Summary/Keyword: HPLC- MSD

Search Result 44, Processing Time 0.02 seconds

Development of Analytical Methods for Micro Levels of Naphthalene and TNT in Groundwater by HPLC-FLD and MSD (HPLC-FLD와 MSD를 이용한 지하수 중 나프탈렌 및 TNT의 미량 분석법 개발)

  • Park, Jong-Sung;Oh, Je-Ill;Jeong, Sang-Jo;Choi, Yoon-Dae;Her, Nam-Guk
    • Journal of Soil and Groundwater Environment
    • /
    • v.14 no.6
    • /
    • pp.35-44
    • /
    • 2009
  • Naphthalene and TNT (2,4,6-trinitrotoluene) are defined by U.S. EPA as possible carcinogenic compounds known to have detrimental effects on the aquatic ecosystem and human body. There are, however, few researches on methods of analyzing micro-levels of naphthalene and TNT dissolved in groundwater. This study introduces and evaluates the newly developed analytical methods of measuring naphthalene and TNT in groundwater by using HPLC-FLD (Fluorescence detector) and MSD (Mass detector). The MDL, LOQ and salt effect of these methods, respectively, are compared with those of conventional methods which use HPLC-UV. For the analysis of naphthalene, HPLC-FLD was set in the maxima wavelength (Ex: 270 nM, Em: 330 nM) obtained from 3D-Fluorescence to be compared with HPLC-UV in 266 nM wavelength. The MDL ($0.3\;{\mu}g/L$) and LOQ ($2.0\;{\mu}g/L$) of naphthalene by using HPLC-FLD were approximately 80 times lower than those analyzed by HPLC-UV (MDL: $23.3\;{\mu}g/L$, LOQ: $163.1\;{\mu}g/L$). HPLC-MSD were used in comparison with HPLC-UV in 230 and 254 nM wavelength for the analysis of TNT. The MDL ($0.13\;{\mu}g/L$) and LOQ ($0.88\;{\mu}g/L$) of TNT analyzed by using HPLC-MSD were approximately 130 times lower than those obtained by using HPLC-UV in 230 nM (MDL: $16.8\;{\mu}g/L$, LOQ: $117.5\;{\mu}g/L$). The chromatogram of TNT analyzed by using HPLC-UV in 230 nM displayed elevated baseline as the concentration of ${NO_3}^-$ increases beyond 21 mg/L, while the analysis using HPLC-MSD did not demonstrate any change in baseline in presence of ${NO_3}^-$ of 63.7 mg/L which is 3.5 times higher than average concentration in groundwater. In conclusion, HPLC-FLD and HPLC-MSD may be used as suitable methods for the analysis of naphthalene and TNT in groundwater and drinking water. These methods can be applied to the monitoring of naphthalene and TNT concentration in groundwater or drinking water.

Analysis of Higenamine Contents in Plants with HPLC and GC/MSD (HPLC 및 GC/MSD를 이용한 식물 중의 Higenamine 함량 분석)

  • YunChoi, Hye-Sook;Suh, Young-Bae;Hahn, Young-Hee;Song, Yun-Seon;Ryu, Jae-Chun;Chung, Kyo-Soon
    • Korean Journal of Pharmacognosy
    • /
    • v.29 no.2
    • /
    • pp.129-135
    • /
    • 1998
  • Higenamine is known as a cardiotonic principle of Aconiti tuber. The analytical procedures were established for the detection of higenamine in plants. The amounts of higenamine in several Aconiti tubers and the embryo of Nelumbo nucifera, another plant species known to contain higenamine, were determined. The $H_2O$ soluble fraction prepared from MeOH extract was first treated with AD-2 resin and then applied to either HPLC or GC/MSD systems. With HPLC, $6.4{\sim}19.2\;{\mu}g/g$ of higenamine were detected from various Aconiti tubers and $182.3\;{\mu}g/g$ of higenamine from the embryo of Nelumbo nucifera. The results obtained with GC/MSD also provided comparable data with those obtained with HPLC.

  • PDF

Simultaneous detection for synthetic antimicrobials in muscle by high performance liquid chromatography-mass selective detector (HPLC-MSD) (HPLC-MSD 를 이용한 식육 중 합성항균제의 동시분석)

  • Hong In-Suk;Choi Yoon-Hwa;Kwon Taek-Boo;Lee Jung-Hark
    • Korean Journal of Veterinary Service
    • /
    • v.29 no.3
    • /
    • pp.317-330
    • /
    • 2006
  • This study was conducted to develop the analytical method about simultaneous determination for synthetic antimicrobials in muscle by high performance liquid chromatography - mass selective detector (HPLC- MSD). Solid phase extraction (SPE), matrix solid phase dispersion (MSPD) and liquid-liquid extraction (LLE) have been adapted as pretreatment procedures for HPLC- MSD. Among various solvent tested, methanol was chosen for extraction of synthetic antimicrobials in muscles. For the optimized response, the values of various MS parameters including fragment voltage, drying gas flow, nebulizer pressure, drying gas temperature were verified. The average recovery rates using MSPD and SPE for muscles of bovine and pork were 78.9-127.1% and 78.3-121.7%, respectively. This method was verified the satisfactory performance for fourteen synthetic antimicrobials excepting carbadox in muscle of pork as detection limit of $0.05{\mu}g/g$ on API/ES SIM mode.

Determination of phenol using solid-phase extraction and HPLC/MSD/FLD in water (고체상추출법과 HPLC/MSD/FLD를 이용한 수질중의 페놀 분석)

  • Lee, Taejoon;Park, Keun-Young;Pyo, Dongjin
    • Analytical Science and Technology
    • /
    • v.28 no.6
    • /
    • pp.370-376
    • /
    • 2015
  • An analytical method for determining phenol considered priority pollutants of the US EPA and precursor of toxic phenolic compounds by solid-phase extraction (SPE) and high performance liquid chromatographic systems (HPLC) equipped with fluorescence and mass selective detectors have been developed. The SPE process for sample preconcentration was performed on a commercially available Oasis HLB cartridge packed with polymeric sorbents. The effect of pH, elution solvent, and elution volume on the recoveries of the analytes were investigated with HPLC/FLD. Average recovery of >87.0% was achieved with 60 mg sorbents using 5 mL of methanol as an elution solvent at pH=3.

A Study on the Analysis of Pesticide Residue in Banana by GC/MSD (GC/MSD를 이용한 바나나 중에서의 잔류농약 분석법에 관한 연구)

  • 박성수;김동원
    • The Korean Journal of Food And Nutrition
    • /
    • v.9 no.2
    • /
    • pp.217-222
    • /
    • 1996
  • We studied about analyzing carbamate pesticides, organochlorine, organophosphorus pesticides simultaneously using by GC/MSD. For this, instead of HPLC which is generally used in analyzing carbamate pesticides, GC was used and all hydrogen of -NH group in carbamate pesticides were substituted for trifluoroacetyl group which is stable at heat And eight pesticide resdidues were not detected in nine samples circulated in the city.

  • PDF

Rapid Analysis of Major Putrefactive Metabolites by GC and GC/MSD (GC 및 GC/MSD를 이용한 주요 분변 부패산물 신속분석법)

  • 박규용;김민철;우강융;이나경;백현동
    • KSBB Journal
    • /
    • v.18 no.1
    • /
    • pp.74-77
    • /
    • 2003
  • A simple, reproducible, and rapid gas chromatographic method for putrefactive metabolite determination in feces was developed. The method involves the direct injection of fecal supernatants into the gas chromatograph, without pretreatment. The mass spectra of these metabolites were obtained using an HP 5971 mass selective detector operated in electron impact (EI) ionization mode. This method produced sharp peaks and allowed the simultaneous determination of fecal putrefactive metabolites.

Determination of Bisphenols Migrating from Epoxy Can Coatings to Aqueous Food Simulants (통조림관 코팅제에서 식품유사용매로 이행되는 비스페놀류의 분석)

  • Kang, Kyung-Mo;Shin, Hyo-Sun
    • Korean Journal of Food Science and Technology
    • /
    • v.32 no.3
    • /
    • pp.570-577
    • /
    • 2000
  • A method was presented for determination of bisphenol F(BPF), bisphenol A(BPA), bisphenol F diglycidyl ether(BFDGE) and bisphenol A diglycidyl ether(BADGE) in 3 aqueous-based food simulants (water, 4% acetic acid, 20% ethanol) by reverse-phase high performance liquid chromatography(RP-HPLC)with fluorescence detection and gas chromatography with mass selective detection(GC/MSD). All the calibration lines in the range of $5{\sim}800\;{\mu}g/L$ had correlation coefficients greater than 0.9998 and detection limits of less than $1.2\;{\mu}g$ bisphenols/L. Precision at $200\;{\mu}g/L$ was under 3.1%. Recoveries of bisphenols simultaneously spiked to aqueous food simulants exceeded 95% for BPF and BPA but about 80% for BFDGE and BADGE. However, recoveris of BFDGE and BPADGE respectively spiked increased upto 95%. Detection limits in recovery test were less than $0.40\;{\mu}g$ bisphenols/L. In migration test bisphenols were determined by RP-HPLC coupled with confirmation by GC/MSD. Can coatings of epoxy phenol, modified epoxy, epoxy ester phenol and thermoset vinyl were exposed to the 3 aqueous food simulants. BPF, BFDGE and BADGE were not detected in all the can coatings but BPA was detected in 4% acetic acid and 20% ethanol in all the can coatings except modified epoxy.

  • PDF

Pesticide Multiresidues Analysis of Environmental-friendly Agricultural Soils by the Complex Cleanup Method of Accelerated Solvent Extraction (ASE) and Solid Phase Extraction (SPE) (ASE 및 SPE 복합정제법을 이용한 친환경농업토양의 다성분잔류농약 분석)

  • Moo, Kyung-Mi;Park, Jin-Woo;Lee, Young-Guen;Choi, Young-Whan
    • Journal of agriculture & life science
    • /
    • v.45 no.5
    • /
    • pp.73-80
    • /
    • 2011
  • Fifty substances of pesticide were selected for analysis through the historical investigation of pesticides detected from environmental-friendly agricultural soil, and the environmental-friendly agricultural soils in Gyeongnam area were collected and then were accepted Anve (accelerated solvent extraction) and SPve (solid-phase extraction) as multiresidue extraction and clean up methods suitable to the soils. The pesticide residues were analyzed by using GC/vCD/NPD, HPLC/UV/FL, GC/MSD, or HPLC/MSD. 50 kinds of pesticides for the soils were an average of 95.5% from retrieval ratio of the 72 to 118% range, and the average of 3.0% for CV (%). Among 40 samples of soil, 20 components were detected from pesticide residues of 21 samples, and average amounts detected for these components were 0.035 for endosulfan, 0.043 for ethoprophos, 0.020 for chlorpyrifos, 0.023 for chlorfenapyr, 0.047 for flufenoxuron, 0.070 for fenvalerate, 0.266 for cypermethrin, 0.016 for lufenuron, 0.022 for bifenthrin, 0.025 for fenobucarb/BPMC, 0.043 for difenoconazole, 0.059 for fenarimol, 0.020 for kresoxim-methyl, 0.026 for tetraconazole, 0.039 for isoprothiolane, 0.017 for iprobenfos, 0.014 for nolrimol, 0.156 for fluquinconazole, 0.047 for tebuconazole, and 0.045 mg/kg for oxadiazon. Therefore it is infered that the establishment of pesticide residues limit for environmental-friendly agricultural soil is needed as soon as possible.

Absence of Tocotrienol Form of Vitamin E in Purple Perilla (Perilla frutescens var. acuta Kudo) Seeds Confirmed by Comparative Analysis Using HPLC and GC (GC 및 HPLC 비교분석에 기초한 차조기 종실내 tocotrienol 부재의 평가)

  • Lee, Young-Sang;Kim, Min-Kyoung
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.53 no.spc
    • /
    • pp.115-120
    • /
    • 2008
  • Lipid soluble vitamin E consists of tocopherols and tocotrienols depending upon double bonds in phytyl side chains attached to chromanol ring. Recent reports on antioxidative, anticancer, and cholesterol-lowering effects of tocotrienols have increased researches and commercialization of tocotrienols. Purple perilla (Perilla frutescens var. acuta Kudo) has been reported as a plant containing tocotrienols along with tocopherol forms of vitamin E based upon normal phase HPLC analysis. To confirm the existence or absence of tocotrienol form of vitamin E in purple perilla, comparative analysis using HPLC, GC/FID, and GC/MSD has been conducted for 14 purple perilla genetic accessions collected from Korea and Japan. Normal phase HPLC analysis showed ${\alpha}-$, ${\beta}-$, ${\gamma}-$, and ${\delta}-tocopherols$ along with peaks with retention times quite similar to ${\beta}-$ and ${\gamma}-tocotrienols$. Same purple perilla samples, analysed by GC exhibited ${\alpha}-$, ${\beta}-$, ${\gamma}-$, and ${\delta}-tocopherols$ quantitatively equivalent to HPLC results. However, no peaks for ${\beta}-$ and ${\gamma}-tocotrienols$ could be observed and unknown two peaks of similar retention times with ${\beta}-$ and ${\gamma}-tocotrienols$ were identified not corresponding tocotrienols by GC/MSD. These results suggest the absence of tocotrienol form of vitamin E in purple perilla as well as the necessity of using GC-based qualitative and quantitative vitamin E analysis to avoid misinterpretation of peaks with similar retention times as tocotrienol isomers when analysed by an HPLC.

Investigation on the products generated by the ozonation of Microcystis sp. (Microcystis sp.의 오존접촉특성 및 부산물 생성에 관한 연구)

  • Kim, Young-Ung;Son, Hee-Jong;Yu, Myung-Ho;Lee, Chun-Sik;Kim, Seong-Yun
    • Journal of Korean Society on Water Environment
    • /
    • v.16 no.4
    • /
    • pp.479-490
    • /
    • 2000
  • This study investigated the removal characteristics, Microcystin decomposition and generation of by-products when aqueous Microcystis sp. is oxidized by ozone. The concentration of Microcystin (MC) in aqueous solution has been found by HPLC analysis to decrease continuously by ozonation after the initial, abrupt increase. The kinetic constant of the decomposition of MC-RR and -LR were 0.0596 and 0.0243, respectively. This means that removal efficiency of MC-RR by its oxidative decomposition is preferable compared with that of MC-LR. On the other hand, it has been found that the decomposition product, TOC, exhibits the continuous decrease in the concentration by further ozonation, while DOC and UV-254 increase temporarily until 10 minutes before the decrease. Furthermore, the GC/MSD analysis has revealed that the ozonation of Microcystis sp. for 100minutes affords five kinds of aldehydes, six kinds of alcohols, and trans-1, 2-dimethyl-cyclopropane.

  • PDF