• Title/Summary/Keyword: HPLC quantification

Search Result 403, Processing Time 0.027 seconds

Rapid and simultaneous determination of metabolites of organic solvents in human urine by high-performance liquid chromatography using a monolithic column (Monolithic 칼럼을 이용한 뇨 중 유기용매 대사체의 신속한 HPLC 동시 분석)

  • Han, Sang Beom;Lee, Sang-Ju;Lee, Cheol-Woo;Yoon, Seo Hyun;Joung, Sun Kyung;Youm, Jeong-Rok
    • Analytical Science and Technology
    • /
    • v.19 no.5
    • /
    • pp.433-440
    • /
    • 2006
  • A HPLC/UV method was developed and validated for the rapid and simultaneous determination of urinary metabolites of organic solvents, mandelic acid, hippuric acid, phenylglyoxylic acid, ortho-, meta- and para-methylhippuric acid, using a monolithic column. The mobile phase was composed of tetrabutylammonium bromide as ion-pairing reagent with a flow rate of 2.4 mL/min. The total run time was less than 2.5 min for all six analytes. Good linearities were obtained for all the metabolites with correlation coefficients above 0.9993. Intra-day precision, accuracy and inter-day precision was 0.01~7.32%, 83.9~116.3% and 0.01~7.16%, respectively. The method was validated and confirmed by quantification of the quality assurance samples of Industrial Safety and Health Research Institute, Korea Occupational Safety and Health Agency.

Determination of Domoic Acid in Seafood Matrices using HPLC-UV with Solid Phase Extraction Cleanup (고체상 추출 전처리 및 HPLC-UV를 이용한 수산물 중 domoic acid의 분석)

  • Si Eun Kim;Sang Yoo Lee;Ji Eun Park;Hyunjin Jung;Hyang Sook Chun
    • Journal of Food Hygiene and Safety
    • /
    • v.38 no.5
    • /
    • pp.297-304
    • /
    • 2023
  • Domoic acid (DA), a neurotoxin produced naturally by diatoms, is responsible for incidents of amnesic shellfish poisoning. In this study, a modified analytical method was established to determine domoic acid in seafood using solid phase extraction cleanup and optimizing the amount of sample and extraction solvent to reduce interference effects. The modified method using high-performance liquid chromatography with ultraviolet detection was validated using three seafood matrices (mussel, red snow crab, and anchovy) at three concentrations (1, 2, and 4 mg/kg) and compared to the Food Code method. Compared to the Food Code method, the modified method showed better performance in terms of linearity (R2>0.999), detection limit (0.02-0.03 mg/kg), quantification limit (0.05-0.09 mg/kg), intra-/inter-day accuracy (86.2-100.4%), and intra-/inter-day precision (0.2-4.0%). Furthermore, the method was successfully applied for the analysis of 87 seafood samples marketed in Korea, and DA was detected at a low concentration of 140 ㎍/kg in one anchovy sample. These results suggest that the modified method can be used for routine determination of DA in seafood.

Analytical method study for cephalexin with high-performance liquid chromatography-tandem mass spectrometry (LC-MS/MS) applicable for residue studies in the whiteleg shrimp Litopenaeus vannamei (흰다리새우(Litopenaeus vannamei)에서 cephalexin의 잔류농도 연구를 위한 LC-MS/MS 분석법 연구)

  • Yang, Chan Yeong;Bae, Jun Sung;Lee, Chae Won;Jeong, Eun Ha;Lee, Ji-Hoon;Bak, Su-Jin;Choi, Sang-Hoon;Park, Kwan Ha
    • Journal of fish pathology
    • /
    • v.34 no.1
    • /
    • pp.71-80
    • /
    • 2021
  • Cephalexin, a semi-synthetic cephalosporin antibiotic, has long been used in fish aquaculture in various countries under legal authorization. The drug is thus widely available for use in other aquatic species except fishes like the crustacean whiteleg shrimp. This study aims to develop a sensitive method for laboratory residue studies to adopt in withdrawal period determinations. Through repeated trials from the existing methods developed for other food animal tissues, it was possible to achieve a sensitive high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method. The results showed that at a concentration of 0.1 mg/kg, the recovery rate was 81.79%, and C.V. value was 8.2%, which meet the recovery rate and C.V. recommended by Codex guideline. After satisfactory validation of analytical procedures, applicability to the shrimp tissue was confirmed in experimentally cephalexin-treated whiteleg shrimp. As a result, most muscle samples were detected below the limit of quantification (0.05 mg/kg) after day 3, and most hepatopancreas samples were detected below the limit of quantification after day 14. In particular, the limit of quantification 0.05 ppm with the presently developed method suggests sufficient sensitive over the current legal maximum residue limit of 0.2 mg/kg set for fishes.

Development of a Method for Analyzing the Nicotine Content in Synthetic Flavoring Substances as Unauthorized E-cigarette Liquid by Using HPLC (전자담배 액상 충진제와 유사한 합성착향료 중 니코틴의 HPLC 분석법 개발)

  • Kim, Jae-Young;Lee, Sang-Mok;Chang, Moon-Ik;Cho, Yoon-Jae;Lee, Han-Jin;Chae, Young-Sik;Rhee, Gyu-Sik
    • Korean Journal of Food Science and Technology
    • /
    • v.45 no.6
    • /
    • pp.693-699
    • /
    • 2013
  • A simple, sensitive, and specific method for quantifying the nicotine content of synthetic favoring substances (SFS) was developed using high performance liquid chromatography (HPLC) with a photo-diode array detector (PDA). Nicotine was extracted from SFS samples by using an acid-base liquid-liquid extraction method with dichloromethane and distilled water. The nicotine content was quantified by HPLC/PDA (261.9 nm) with a $C_{18}$ column under a gradient of 10% acetonitrile with 20 mM ammonium formate (ammonia solution adjusted to pH 8.7) to 100% acetonitrile. The calibration curve, analyzed from concentration standards between 0.1 to 2 mg/L, presented linearity with a correlation coefficient ($r^2$)>0.9999. The limit of quantitation (LOQ) of nicotine in SFS was 0.4 mg/kg, and the average recoveries ranged from 76.4% to 96.3%. The repeatability of measurements, expressed as the coefficient of variation (CV%), ranged from 1.74 to 5.12%. This newly developed method for nicotine quantification in SFS can be considered an analytical method with an acceptable level of sensitivity and repeatability.

Single Laboratory Validation and Uncertainty Estimation of a HPLC Analysis Method for Deoxynivalenol in Noodles (면류에서 HPLC를 이용한 데옥시니발레놀 분석법의 검증과 불확도 산정)

  • Ee, Ok-Hyun;Chang, Hyun-Joo;Kang, Young-Woon;Kim, Mee-Hye;Chun, Hyang-Sook
    • Journal of Food Hygiene and Safety
    • /
    • v.26 no.2
    • /
    • pp.142-149
    • /
    • 2011
  • An isocratic high performance liquid chromatography (HPLC) method for routine analysis of deoxynivalenol in noodles was validated and estimated the measurement uncertainty. Noodles (dried noodle and ramyeon) were analyzed by HPLC-ultraviolet detection using immunoaffinity column for clean-up. The limits of detection (LOD) and quantification (LOQ) were 7.5 ${\mu}g$/kg and 18.8 ${\mu}g$/kg, respectively. The calibration curve showed a good linearity, with correlation coefficients $r^2$ of 0.9999 in the concentration range from 20 to 500 ${\mu}g$/kg. Recoveries and Repeatabilities expressed as coefficients of variation (CV) spiked with 200 and 500 ${\mu}g$/kg were $82{\pm}2.7%$ and $87{\pm}1.3%$% in dried noodle, and $97{\pm}1.6%$ and $91{\pm}12.0%$ in ramyeon, respectively. The uncertainty sources in measurement process were identified as sample weight, final volume, and sample concentration in extraction volume as well as components such as standard stock solution, working standard solution, 5 standard solutions, calibration curve, matrix, and instrument. Deoxynivalenol concentration and expanded uncertainty in two matrixes spiked with 200 ${\mu}g$/kg and 500 ${\mu}g$/kg were estimated to be $163.8{\pm}52.1$ and $435.2{\pm}91.6\;{\mu}g$/kg for dried noodle, and $194.3{\pm}33.0$ and $453.2{\pm}91.1\;{\mu}g$/kg for ramyeon using a coverage factor of two which gives a level of statistical confidence with approximately 95%. The most influential component among uncertainty sources was the recovery of matrix, followed by calibration curve.

Establishment of an Analytical Method for Novobiocin in Livestock Products Using HPLC-UVD (HPLC-UVD를 이용한 축산식품 중 Novobiocin의 시험법 확립)

  • Park, Hee-Ra;Kwon, Chan-Hyeok;Lee, Jong-Goo;Kim, Hyung-Soo;Chae, Young-Sik;Oh, Jae-Ho;Kwon, Ki-Sung
    • Korean Journal of Food Science and Technology
    • /
    • v.44 no.3
    • /
    • pp.263-268
    • /
    • 2012
  • Novobiocin is a coumarin-containing antibiotic, and has a longer half-life in various animals than other veterinary medicines. A simple and rapid high-performance liquid chromatography assay for the determination of residual novobiocin levels in chicken, beef and milk has been developed and validated. The separation condition for HPLC/UVD was optimized by a MG II $C_{18}$ (4.6 mm $ID{\times}250$ mm, 5 ${\mu}m$) column with 0.1% formic acid in $H_2O$/0.1% formic acid in Acetonitrile (40/60, v/v) as the mobile phase at a flow rate of 1.0 mL/min and the detection wavelength was set at 340 nm. Residues were extracted from tissue by blending with methanol. After liquid-liquid partitioning, lipid materials were removed with n-hexane and purification as Silica (1 g, 6 mL) cartridge with 10 mL acetone/dichloromethane (10/90, v/v). Limit of quantification and linearity performed by the analytical method were 0.02 mg/kg and 0.999 ($r^2$), and the recovery range was $88.8{\pm}5.6-100.3{\pm}4.4$, $88.8{\pm}7.2-97.0{\pm}3.2$ and $88.1{\pm}4.3-92.8{\pm}3.6%$. It is expected that this analytical method with regards to novobiocin in chicken, beef and milk could be applied as an official method to administer food safety on veterinary medicines.

Quantitative determination of inosine 5'-monophosphate dehydrogenase activity in human peripheral blood mononuclear cells by ion-pair reversed-phase high-performance liquid chromatography (이온쌍 역상 HPLC를 이용한 인체 말초혈액단핵구에서 이노신 5'-일인산 탈수소효소 활성의 정량적 측정)

  • Shin, Hye-Jin;Kwon, Soon-Ho;Park, Ji-Myeong;Kwon, Soon-Hyo;Lee, Kyoung-Ryul;Kim, Young-Jin;Lee, Sang-Hoo
    • Analytical Science and Technology
    • /
    • v.23 no.6
    • /
    • pp.531-536
    • /
    • 2010
  • A quantitative analytical method has been established for the measurement of inosine 5'-monophosphate dehydrogenase (IMPDH) activity in human peripheral blood mononuclear cells (PBMCs) by ion-pair reversed-phase high performance liquid chromatography equipped with ultraviolet detection (HPLC/UV). IMPDH is a ${\beta}$-nicotinamide adenine dinucleotide hydrate (NAD+)-dependent dehydrogenase in which the enzyme converts inosine 5'-monophosphate (IMP) into xanthosine 5'-monophosphate (XMP). Its activity was measured by quantifying a HPLC chromatogram corresponding to XMP produced during the incubation of lysed PBMCs with IMP as a substrate and $NAD^+$ as a coenzyme. XMP produced was detected at a wavelength of 260 nm. The mobile phase was composed of a mixture of 37 mM potassium dihydrogen phosphate containing 7 mM tetra-n-butylammonium hydrogen sulfate adjusted to pH 5.5 and methanol (85:15, v/v) with a flow rate of 1 mL/min. The calibration curve was linear ($r^2$=0.999999) in the range of $0.2-50.0\;{\mu}M$ and the limit of quantification (LOQ) was $0.2\;{\mu}M$. The intra- and inter-day precisions were between 0.88-1.47% and 0.85-5.24%, respectively. The intra- and inter-day accuracies were between 98.74-99.99% and 99.95-101.65%, respectively. IMPDH activity in 11 Korean healthy volunteers ranged from 18.29 to 36.60 nmol/h/mg protein (mean = $27.70{\pm}6.28\;nmol/h/mg$ protein).

Analytical Validation of Rosmarinic Acid in Water Extract of Perilla frutescens Britton var. acuta Kudo as Functional Health Ingredient (건강기능식품 기능성 원료로써 장흥 차조기 열수 추출물의 지표성분인 로즈마린산 분석법 검증)

  • Park, Sung-Yong;Kim, Jung-Eun;Choi, Chul-Yung;Lee, Dong-Wook;Kim, Ki-Man;Yoon, Goo;Yoon, In-Su;Moon, Hong-Seop;Cho, Seung-Sik
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.44 no.1
    • /
    • pp.85-88
    • /
    • 2015
  • This study attempted to establish an HPLC analysis method for determination of marker compounds as a part of material standardization for the development of health functional food materials from Perilla frutescens Britton var. acuta Kudo. The quantitative determination method of rosmarinic acid as a marker compound of P. frutescens Britton var. acuta Kudo extract (PFE) was optimized by HPLC analysis using a C18 column ($4.6{\times}150mm$, $5{\mu}m$) with 0.1% acetic acid as the elution gradient and methanol as the mobile phase at a flow rate of 1 mL/min and detection wavelength of 280 nm. The HPLC/UV method was applied successfully to quantification of the marker compound in PFE after validation of the method with linearity, accuracy, and precision. The method showed high linearity in the calibration curve at a coefficient of correlation ($R^2$) of 0.9995, and the limit of detection and limit of quantitation were $0.36{\mu}g/mL$ and $1.2{\mu}g/mL$, respectively. Relative standard deviation (RSD) values of data from intra- and inter-day precision were less than 3.21% and 1.43%, respectively. Recovery rate test at rosmarinic acid concentrations of 12.5, 25 and $50{\mu}g/mL$ scored between 97.04~98.98% with RSD values from 0.25~1.97%. These results indicate that the established HPLC method is very useful for the determination of marker compound in PFE to develop a health functional material.

Analysis of Diflubenzuron in Agricultural Commodities by Multiresidue Method (동시 다성분 분석법에 의한 농산물 중 Diflubenzuron 분석)

  • Park, Sun-Hee;Han, Chang-Ho;Kim, Ae-Kyung;Shin, Jae-Min;Lee, Jae-Kyoo;Park, Young-Hae;Kim, Ji-Min;Hwang, Lae-Hong;Chang, Min-Su;Song, Mi-Ok;Park, Ju-Sung;Yun, Eun-Sun;Kim, Mu-Sang;Jung, Kweon
    • The Korean Journal of Pesticide Science
    • /
    • v.18 no.4
    • /
    • pp.269-277
    • /
    • 2014
  • The multiclass pesticide multiresidue method for the simultaneous determination of diflubenzuron in agricultural products was conducted by using HPLC-UVD. The method was validated through the guidelines of linearity, specificity, limit of detection (LOD), limit of quantification (LOQ), accuracy and precision with pesticide-free spinach, Korean cabbage, eggplant, squash, sweet pepper, cucumber, Korean melon. The calibration curve of diflubenzuron was linear over the concentration range of 0.05-5 mg/kg with correlation coefficient of above 0.99999. The limit of detection and quantification was 0.008 and 0.02 mg/kg. Mean recoveries of diflubenzuron for each sample were 77.5-105.6%. Relative standard deviation (RSD) in recoveries were all less than 20%. The intra-day and inter-day precision (RSD) were 0.4-1.9% and 0.7-1.9%, respectively. The result of validation indicated that this method was accurate and rapid assay.

Quantification of seleno proteins in Korean blood serum using solid phase extraction and affinity chromatography-inductively coupled plasma/mass spectrometry (고체상 추출과 친화 크로마토 그라피-유도결합 플라즈마 질량분석법을 이용한 한국인 혈청에서의 셀레노 단백질 정량)

  • Ahn, Ji-Yun;Kwon, Hyo-Sik;Pak, Yong-Nam
    • Analytical Science and Technology
    • /
    • v.27 no.2
    • /
    • pp.92-99
    • /
    • 2014
  • Interferences were removed using anion exchange solid phase extraction (AE SPE) in quantification of selenoproteins in Korean human blood serum with affinity high performance liquid chromatography (AF HPLC)-inductively coupled plasma/mass spectrometry (ICP/MS). The average selenium level obtained for healthy Koreans was $94.3{\pm}2.3ngg^{-1}$ using isotope dilution method. AE SPE was coupled to AF column to separate 3 selenoproteins, glutathione peroxidase GPx, selenoprotein SelP, and selenoalbumin SeAlb. Post column isotope dilution was employed to quantify the proteins. The certified reference material of human blood serum BCR-637 was analyzed to give total selenoprotein concentration of $85.4{\pm}3.4ngg^{-1}$, which agreed well with the reference value of $81{\pm}7ngg^{-1}$. The pooled concentration of GPx, SelP, and SeAlb from healthy Koreans (n=20) was $12.1{\pm}1.4ngg^{-1}$, $57.2{\pm}2.0ngg^{-1}$, and $20.0{\pm}1.9ngg^{-1}$, respectively. The sum of selenoproteins is $89.3ngg^{-1}$, which is about the same as the total selenium concentration of $94.3ngg^{-1}$. The fact suggests that selenium in blood serum is mostly consisted of selenoproteins. After the removal of interference, GPx showed a significant decrease (more than 50%) from $25.0ngg^{-1}$ to $12.1ngg^{-1}$. It was identified that the interference in blood serum was mostly from GPx and the use of AE SPE was proven to be efficient in eliminating Cl and Br that cause interference to GPx.