• Title/Summary/Keyword: HPLC Analysi

Search Result 8, Processing Time 0.018 seconds

Isolation, Purification and Hypotensive Effect of Bioflavonoids in Citrus sinensis (감귤의 Bioflavonoids 분리, 정제 및 혈압강하효과)

  • 손흥수;김현숙;권태봉;주진순
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.21 no.2
    • /
    • pp.136-142
    • /
    • 1992
  • The crude bioflavonoids were obtained by methanol and butanol extraction from Iyophilized orange (Citrus sinensis) peel. And then, its yield was about 0.26% in dry base. Two bioflavonoids were purified by gel filtration and HPLC, and could be identified narirutin and hesperidin through TLC, HPLC, UV spertrum and NMR analysis. The yields of narirutin and hesperidin from a gram of crude bioflavonoids were 42mg and 530mg respectively, and the main fraction of bioflavonoid from orange peel was supposed to be hesperidin. Each component was intravenously injected into Sprague-Dawley rats (1mg/100g body weight) and hesperidin was found to lower their blood pressure significantly (p < 0.001).

  • PDF

Simultaneous Gas Chromatographic Analysis of Ethanol and Acetic Acid in Vinegar (식초의 에탄올 및 초산 함량의 동시분석)

  • Yoon, Hee-Nam
    • Korean Journal of Food Science and Technology
    • /
    • v.30 no.6
    • /
    • pp.1247-1251
    • /
    • 1998
  • A method is developed for simultaneously determining ethanol and acetic acid in vinegars by quantitative packed-column gas chromatography. Vinegars were filtrated and directly chromatographed on a $2\;m{\times}2\;mm$ stainless steel column packed with Tenax-GC, 80/100. Ethanol, isopropy alcohol as an internal standard, and acetic acid were completely separated within 20 min of running time without any interfering peaks. The accuracy of packed column gas solid chromatography (PCGSC) was discussed compared to the analytical data by titration, high performance liquid chromatography and capillary column gas liquid chromatography (CCGLC).

  • PDF

Measurement of Langmuir Adsorption Equilibrium by Elution-curve Method and Frontal Analysis (용출곡선법과 Frontal Analysis를 이용한 Langmuir 흡착평형식의 측정)

  • Choi, Yong Seok;Lee, Chong Ho;Row, Kyung Ho
    • Applied Chemistry for Engineering
    • /
    • v.10 no.5
    • /
    • pp.672-676
    • /
    • 1999
  • Adsorption isotherm is the most fundamental information in adsorption separation-process. Directly from the elution profile of a peak, the elution-curve method and frontal analysis(FA) were utilized to measure the adsorption isotherm in this work. Using RP-HPLC, sample and the buffer added in mobile phase were 5'-GMP and sodium phosphate, respectively. In this experimental condition, the retention time was decreased with increase in the injected mass of sample. And the front part of a peak was very stiff, so Langmuir adsorption isotherm might be applied. By the elution-curve method, the parameters used in the isotherm were obtained by optimization method, while by the FA, the concentrations of stationary phase were measured from the elution curve and the isotherm was determined by regression analysis. Compared to FA, the consumption of sample was less, and only one or two injections were needed by the elution-curve method. Finally, the effect of concentration of sodium phosphate in mobile phase on the parameters of the isotherm was investigated.

  • PDF

Protein Binding of [S]-Perillyl Alcohol in HSA using High-Performance Frontal Analysis (HPFA를 이용한 HSA와 [S]-Perillyl Acohol의 단백질 결합력)

  • 송명석;왕덕선;구윤모;노경호
    • KSBB Journal
    • /
    • v.18 no.2
    • /
    • pp.100-106
    • /
    • 2003
  • An on-line frontal analysis HPLC system was developed to determine the unbound concentration of (S)-perillyl alcohol, an potential anti-cancer agent, in human serum albumin (HSA) solution, The analysis was performed on a Develosil 100 Diol 5 (10 cm x 4.6 mm I.D.) high-performance frontal analysis (HPFA) column. Sodium phosphate solution was used as the mobile phase (pH 7.4, ionic strength 0.17) at a flow rate of 1 $m\ell$/min. UV wavelength was set at 205 nm. A injection volume of 600${mu}ell$ was chosen to ensure the compound eluted formed a zonal peak with a plateau. By Scatchard analysis, it was found that the binding constant(K) and binding number(n) of (S)-perillyl alcohol to molecular HSA were 2.05 x $10^6$ [$M{-1}$], 0.00428, respectively.

Hydroxyapatite Solubilization and Organic Acid Production by Enterobacter agglomerans (인산염 가용화균 Enterobacter agglomerans에 의한 Hydroxyapatite 가동화와 유기산 생성)

  • Kim, Kil-Yong
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.30 no.2
    • /
    • pp.189-195
    • /
    • 1997
  • A phosphate solubilizing bacterium (PSB) possessing a high ability to solubilize hydroxyapatite (HA) was isolated from the rhizosphere of wheat. The PSB markedly developed clear zones after inoculating for 36 hours at $30^{\circ}C$. This bacterium was identified as Enterobacter agglomerans through API 20E system and Biolog$^{TM}$ analysis. The values of similarity and distance coefficient from authentication trial of the strain were 0.656 and 4.79 respectively. High performance liquid chromatography (HPLC) of the products of this strain indicated that this strain excretes maily oxalic acid with som other organic acids. During the incubation period of E. agglomerans, the pH values showed an inverse correlation ($r^2=0.933^{**}$) with solubilization of inorganic phosphate. Acid phosphatase activity of the strain was 10-15 times greater than alkaline phosphatase activity. Alkaline phosphatase activity had almost constant near zero activity across time. The population of E. agglomerans greatly increased during the first day of inoculation ; however, it drastically decreased thereafter.

  • PDF

Determination of Loxoprofen Adsorption Isotherms by Frontal Analysis and Pulse Input Method (Frontal Analysis와 Pulse Input Method를 이용한 Loxoprofen의 등온흡착식 결정)

  • Lee, Eun;Park, Joon-Sub;Kim, In-Ho
    • KSBB Journal
    • /
    • v.21 no.5
    • /
    • pp.371-375
    • /
    • 2006
  • Frontal analysis(FA) and Pulsed input method(PIM) have been frequently utilized to measure isotherm of single solute, as well as non-competitive isotherms of two solutes in chromatography(1). FA and PIM were used in this study as complementary methods to measure adsorption isotherms of loxoprofen racemate in HPLC. Prior to FA and PIM experiments, measurements of loxoprofen solubility were made at hexane/ethanol=50/50, 80/20, 95/5(v/v) with acetic acid(0.5%) for adjusting pH. The last composition(95/5) of hexane/ethanol allows us to separate loxoprofen racemate into two forms(retentate, extract). PIM and FA were used to determine the isotherms of re-and ex-loxoprofen.

Evaluation of Enzymatic Method using an Automated Chemistry Analyzers for Homocysteine Measurement

  • Shim, Moon-Jung
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.39 no.3
    • /
    • pp.196-200
    • /
    • 2007
  • In clinical practice, homocysteine has gained popularity because its elevated values are strongly associated with an increased risk of cardiovascular disease. More recently, a new enzymatic colorimetric assay for homocysteine in biological sample, suitable for automated clinical analyzers, has been proposed. To evaluate one of these enzymatic methods and compare the results obtained with this method with those of an immunoenzymatic method, thirty-two samples were analyzed for total homocysteine by HiSens$^{(R)}$ homocysteine reagent on the automated chemistry analyzers TBA 200FR and compared to the widely used immunoenzymatic method ADVIA Centaur. In TBA 200FR, the within-run CVs of two control materials were 3.23% and 0.92%, respectively; the between run CVs were 4.58% and 2.55%, respectively. And in ADVIA 1650, the within-run CVs were 6.81% and 0.99%, respectively; the between run CVs were 9.0% and 3.9%, respectively. The recovery for homocysteine was 100% ($60.8{\mu}mol/L$), 99.1% ($48.64{\mu}mol/L$), 96.3% ($36.48{\mu}mol/L$), 96.1% ($24.32{\mu}mol/L$), and 92.1% ($12.16{\mu}mol/L$). The regression equation of TBA 200FR vs. ADVIA Centaur was y=0.9095x-2.5086 (r=0.9632). And the regression equation for the ADVIA 1650 chemistry vs. Immulite 2000 was y=0.8418x + 0.3207 (r=0.9625). In conclusion, this enzymatic method using automated chemistry analyzer for homocysteine assay shows acceptable analytical performance. I suggest that this assay will be suitable for routine analysis.

  • PDF

Effects on Ginseng Growth and Ginsenoside Content in ICT-based Process Cultivation and Conventional Cultivation (ICT 기반의 공정재배와 관행재배에 있어서 인삼 생장 및 진세 노사이드 함량에 미치는 영향)

  • Kwang Jin Chang;Yeon Bok Kim;Hyun Jung Koo;Hyun Jin Baek;Eui Gi Hong;Su Bin Lee;Jeei Hye Choi;Hyo Yeon Son;Tae Young Kim;Dong Hyun Kim
    • Journal of Practical Agriculture & Fisheries Research
    • /
    • v.25 no.2
    • /
    • pp.12-19
    • /
    • 2023
  • This study conducted an experiment with EC 1.0ms/cm ratio and excellent soil conditions for germination in ICT-based ginseng process cultivation. The first growth survey was conducted before transplantation of ginseng 1-year roots grown by seeding ginseng in the process cultivation, conventional cultivation and a second growth comparison survey was conducted after 3 months of growth. In the results, it was confirmed that ginseng grown in the process cultivation grew more than in the field. As a result of comparing the contents of 11 ginsenosides of 1-year and 2-year-old ginsenosides in the process cultivation and conventional cultivation ginseng, it was confirmed that the content of the process cultivation ginseng was higher than that of practice cultivation ginseng. In conclusion, conventional cultivation ginseng grows due to various factors under the natural cultivation environment, but process cultivation can secure the growth stability of ginseng by allowing stable soil and environmental control, so continuous research is needed in the future.