• Title/Summary/Keyword: HOOPS

Search Result 69, Processing Time 0.024 seconds

Evaluation of Effective Section Area of Shear Steel in Reinforced Concrete Circular Columns (철근콘크리트 원형기둥의 전단철근 유효단면적 평가)

  • 김장훈
    • Journal of the Korea Concrete Institute
    • /
    • v.11 no.3
    • /
    • pp.81-88
    • /
    • 1999
  • In order to properly evaluate the shear strength of reinforced concrete circular columns due to the transverse shear reinforcement, the average of fractions of forces generated along the circular transverse hoops across the shear failure plane in the loading direction is calculated. For this, the center-to-center diameter of circular transverse hoops. spacing and the crack angle measured to the column longitudinal axis are considered. Using these variables, an equation representing the effective section area of circular transverse shear steel is proposed. The study result shows that the constant parameter. used for the calculation of the effective section area of circular hoops over the last 10 years, should not universally be applied any more. The use of the constant parameter may not seriously do harm to the evaluation of shear strength for circular columns with non-seismically designed transverse hoop reinforcement, since it gives slightly conservative results. However. for well-confined circular columns with close spacing or circular steel jacketing. it gives about 20% overestimation of the shear capacity contributed by the transverse hoop steel.

Seismic tests of RC shear walls confined with high-strength rectangular spiral reinforcement

  • Zhao, Huajing;Li, Qingning;Song, Can;Jiang, Haotian;Zhao, Jun
    • Steel and Composite Structures
    • /
    • v.24 no.1
    • /
    • pp.1-13
    • /
    • 2017
  • In order to improve the deformation capacity of the high-strength concrete shear wall, five high-strength concrete shear wall specimens confined with high-strength rectangular spiral reinforcement (HRSR) possessing different parameters, were designed in this paper. One specimen was only adopted high-strength rectangular spiral hoops in embedded columns, the rest of the four specimens were used high-strength rectangular spiral hoops in embedded columns, and high-strength spiral horizontal distribution reinforcement were used in the wall body. Pseudo-static test were carried out on high-strength concrete shear wall specimens confined with HRSR, to study the influence of the factors of longitudinal reinforcement ratio, hoop reinforcement form and the spiral stirrups outer the wall on the failure modes, failure mechanism, ductility, hysteresis characteristics, stiffness degradation and energy dissipation capacity of the shear wall. Results showed that using HRSR as hoops and transverse reinforcements could restrain concrete, slow load carrying capacity degeneration, improve the load carrying capacity and ductility of shear walls; under the vertical force, seismic performance of the RC shear wall with high axial compression ratio can be significantly improved through plastic hinge area or the whole body of the shear wall equipped with outer HRSR.

Behavior of concrete columns confined with both steel angles and spiral hoops under axial compression

  • Zhou, Chunheng;Chen, Zongping;Shi, Sheldon Q.;Cai, Liping
    • Steel and Composite Structures
    • /
    • v.27 no.6
    • /
    • pp.747-759
    • /
    • 2018
  • This study proposed a new type of concrete column that was confined with both steel angles and spiral hoops, named angle-steel and spiral confined concrete (ASCC) column. A total of 22 ASCC stub columns were tested under axial compression to investigate their behavior. For a comparison, three angle-steel reinforced concrete (ARC) stub columns were also tested. The test results indicated that ASCC column had a superior mechanical performance. The strength, ductility and energy absorption were considerably increased due to the improvement of confinement from spiral hoops. The confinement behavior and failure mechanism of ASCC column were investigated by the analysis of failure mode, load-deformation curve and section-strain distribution. Parametric studies were carried out to examine the influences of different parameters on the axial compression behavior of ASCC columns. A calculation approach was developed to predict the ultimate load carrying capacity of ASCC columns under axial compression. It was validated that the predicted results were in well agreement with the experimental results.

Seismic Response of Exterior RC Column-to-Steel Beam Connections (I. Experiment) (콘크리트 기둥-강재 보 외부 접합부의 내진성능(I. 실험))

  • 조순호
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2000.04a
    • /
    • pp.275-282
    • /
    • 2000
  • The seismic behavior of moment connections consisting of reinforced concrete columns and steel beams is investigated based on four 2/3 scale tests of exterior beam-column joints subject to reversed cyclic loading. The major test parameters were the number of hoops the isolated concrete contribution and the use of headed studs in the joint regions between columns and beams. Their influence on the seismic response of the connections is presented and compared. Among them the CF3 specimen containing two hoops each in the joint and column regions above and below exhibited the most favourable hysteretic response. This indicates that this type of joint details can be used in the low seismic areas such as Korea.

  • PDF

Experimental Study on the Confining Effects of Various Detailing Methods at Ends of Flexural Shear Walls (전단벽의 양단부 기둥식 보강기법 연구)

  • 김두영;천영수;조순호;최기봉;정하선;이리형
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1993.04a
    • /
    • pp.154-159
    • /
    • 1993
  • To develop the detailing methods at the ends of flexural shear walls. which are satisfying the ductility requirement corresponding to R = 3.5 and capable of improving the consturctibility, tests of ten isolated cantilever shear walls were carried out under the load condition comprising the cyclic lateral and constant vertical loads. major test parameters include the way of detailing and arrangement of transverse reinforcement in the boundary elements at the ends of walls, and placement of vertical reinforcement. From tests, comparable ductile behavior in test specimens incorporating the channel type of open hoops, compared with those incorporating the regular type of closed hoops, was observed.

  • PDF

Strength and Ductility of R/C Columns with Welded Reinforcement Grids(II) - Focused on Comparisons with Columns Confined by Conventional Reinforcement (용접 띠철근으로 보강된 철근콘크리트 기둥의 강도와 연성(II) - 보편적인 띠철근 보강 기둥과의 비교를 중심으로)

  • ;Murat Saatcioglu;Mongi Grira
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.10a
    • /
    • pp.561-568
    • /
    • 1997
  • Conventional confinement reinforcement for rectangular columns consist of closely spaced perimeter hoops, overlapping hoops, and crossties. One of the potential alternatives to conventional reinforcement is a welded reinforcement grid, prefabricated to required size and volumetric ratio of transverse reinforcement. An experimental investigation was carried out to investigate the strength and deformability of reinforced concrete columns confined with welded reinforcement grids. The comparisons of the envelopes of experimental force-displacement hysteric relationships for columns confined by welded grids with analytically generated force-displacement curves for columns confined with conventional ties. In general, inelastic deformability beyond the peak, as indicate by the slope of the cuvers, was similar to those indicated by columns with conventional ties. The superior performance of columns with welded grids may be attributed to the improved confinement characteristics of grids associated with increased rigidity of welded ties.

  • PDF

New analytical model for the hoop contribution to the shear capacity of circular reinforced concrete columns

  • Trentadue, Francesco;Quaranta, Giuseppe;Greco, Rita;Marano, Giuseppe Carlo
    • Computers and Concrete
    • /
    • v.14 no.1
    • /
    • pp.59-71
    • /
    • 2014
  • The paper is concerned with the analytical description of a resistance mechanism, not considered in previous models, by which the hoops contribute to the shear capacity of RC columns with circular cross sections. The difference from previous approaches consists in observing that, because of deformation, the hoops change their original shape and, as a consequence, their slope does not match anymore the original one in the neighborhood of a crack. The model involves two parameters only, namely the crack inclination and the hoop strain in the neighborhood of a crack. A closed-form analytical formulation to correlate the average value of the crack width and the hoop strain is also provided. Results obtained using the proposed model have been compared with experimental data, and a satisfactory agreement is found.

A Study on the Development of Feature-based Solid Modeler (특징형상 기반 솔리드 모델러 개발에 관한 연구)

  • 이성수
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1999.10a
    • /
    • pp.544-548
    • /
    • 1999
  • This study is about development of Feature-based Solid Modeling system in integrated CAD/CAM environment. Parasolid modeling kernel and HOOPS/3D graphics library was used to develop this system in PC level. System feature library was defined using both procedural and declarative approach method. The raw stock is created by boolean operator using design primitives, and a part is designed that pre-defined feature is removed from the raw stock. This method is called "DSG(Destructive Solid Geometry)" and basic constructive operator of this system. This is not complete system and only the first step to develop Feature-based Solid Modeling System using Parasolid. We will add more powerful functionality and flexible GUI in Windows.n Windows.

  • PDF

Stud reinforcement in beam-column joints under seismic loads

  • Abdollahzadeh, Gholamreza;Ghalani, Saeed Eilbeigi
    • Computers and Concrete
    • /
    • v.18 no.3
    • /
    • pp.297-317
    • /
    • 2016
  • Current codes recommend large amounts of shear reinforcement for reinforced concrete beam-column joints that causes significant bar congestion. Increase in congestion of shear reinforcement in joint core (connection zone), leads to increase accomplishment problems. The congestion may also lead to diameter limitations on the beam bars relative to the joint dimensions. Using double headed studs instead of conventional closed hoops in reinforced concrete beam-column joints reduces congestion and ensures easier assembly of the reinforcing cage. The purpose of this research is evaluating the efficiency of the proposed reinforcement. In this way, 10 groups of exterior beam-column joints are modeled. Each group includes 7 specimens by different reinforcing details in their joint core. All specimens are modeled by using of ABAQUS and analyzed subjected to cyclic loading. After verification of analytical modeling with an experimental specimen, 3D nonlinear specimens are modeled and analyzed. Then, the effect of amount and arrangement of headed studs on ductility, performance, ultimate strength and energy absorption has been studied. Based on the results, all joints reinforced with double headed studs represent better performance compared with the joints without shear transverse reinforcement in joints core. The behavior of the former is close to joints reinforced with closed hoops and cross ties according to the seismic design codes. By adjusting the arrangement of double-headed studs, the decrease in ductility, performance, ultimate moment resistant and energy absorption reduce to 2.61%, 0.90%, 0.90% and 1.66% respectively compared with the joints reinforced by closed hoops on the average. Since the use of headed studs reduces accomplishment problems, these amounts are negligible. Therefore, use of double-headed studs has proved to be a viable option for reinforcing exterior beam-column joints.

Seismic Performance of Octagonal Flared RC Columns using Oblong Hoops (장방형 띠철근을 이용한 팔각형 플레어 RC 기둥의 내진성능)

  • Ko, Seong-Hyun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.6
    • /
    • pp.1-9
    • /
    • 2015
  • Transverse steel bars are used in the plastic hinge zone of columns to insure adequate confinement, prevention of longitudinal bar buckling and ductile behavior. Fabrication and placement of rectangular hoops and cross-ties in columns are difficult to construct. Details of reinforcement for rectangular section require a lot of rectangular hoops and cross-ties. In this paper, to solve these problems, the new lateral confinement method using oblong hoop is proposed for the transverse confinement of the flared column. It can be the alternative for oblong cross-section and flared column with improved workability and cost-efficiency. The final objectives of this study are to suggest appropriate oblong hoop details and to provide quantitative reference data and tendency for seismic performance or damage assessment based on the drift levels such as residual deformation, elastic strain energy. This paper describes factors of seismic performance such as ultimate displacement/drift ratio, displacement ductility, response modification factor, equivalent viscous damping ratio and effective stiffness.