MARGINAL LEAKAGE TEST ON HI-POL COMPOSITE RESIN (국산 하이폴 복합레진의 변록누출에 관한 실험적 연구)

  • Lim, Sung-Sam
    • The Journal of the Korean dental association
    • /
    • v.15 no.11
    • /
    • pp.757-761
    • /
    • 1977
  • The purpose of this study was to evaluate the marginal sealing ability of Hipol composite resin. Using freshly extracted human teeth and 2% acquous methylene blue, the marginal leakage of dye in restorative materials such as Hi-pol, Adaptic, Nuvasystem, Epolite and Amalgam was investigated at 37℃ and under temperature cycling between 4℃ and 60℃. The results were as follows; 1. All the filling materials revealed the penetration of dye between cavity walls and restorations. 2. Hi-pol and Adaptic showed more marginal leakage than other materials and the degree of dye penetration in Hi-pol was similar to that of Adaptic. 3. Nuva system showed the least marginal leakage at 37℃ and under temperature cycling between 4℃ and 60℃. 4. Under temperature cycling, all materials showed a slight increase in marginal leakage except Epolite, which showed the greastest change in leakage.

  • PDF

Harmonization of Hemolysis Index in Clinical Chemistry Laboratory and Its Application as a Result Verification Tool (화학검사 결과의 검증을 위한 용혈 지수 일치화 도구 개발)

  • Pyo, Sang Shin;Nam, Hyun Su;Cha, Young Jong;Lee, Seungkwan;Lee, Hae Kyung
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.49 no.4
    • /
    • pp.350-358
    • /
    • 2017
  • The hemolysis index (HI) is semi-quantitative marker for hemolysis. Because the characteristics of the HI vary from one commercial platform to another, no standardization or harmonization of the HI is currently available. Specimens (N=40) randomly selected from clinical patients were artificially hemolyzed in vitro. The serum of the specimens was then diluted with a 20 mg/dL difference between 0~300 mg/dL based on serum hemoglobin measured using the XE-2100 hematology automation equipment (Sysmex, Japan). Diluted serum was measured using the Hitachi-7600 biochemical automation equipment (Hitachi, Japan) to differentiate between HI and serum hemoglobin. The data showed linearity between HI and serum hemoglobin and that HI 1 contained approximately 20 mg/dL of serum hemoglobin. To determine the blood rejection threshold, the HI was divided into three groups: HI 0~1, HI 4~6, HI 9~15. After another batch of clinical specimens (N=40) was measured using a Hitachi-7600 (Hitachi, Japan), each specimen was moved forward and backward with the piston of the syringe to induce an artificial in vitro hemolysis, then measured again with a Hitachi-7600 (Hitachi, Japan). The percentage difference between the three groups was analyzed by ANOVA or the Kruskal-Wallis test. In the post-test, there were significant differences between the HI 0~1 and the HI 5~6: Glucose, creatinine, total protein, AST, direct bilirubin, uric acid, phosphorus, triglyceride, LDH, CPK, Magnesium, and potassium levels. Because many clinical tests differed significantly, the threshold for hemolysis could be appropriate for HI 5 (serum hemoglobin 100 mg/dL).

Studies of the egg drop laying diseases from the mass zone layer (산란계 밀집지역의 산란저하성 질병에 관한 연구)

  • Lee Jeoung-Won;Eum Sung-Shim;Park In-Gyu;Bea Joung-Jun;Joung Dong-Suk;Song Hee-Jong
    • Korean Journal of Veterinary Service
    • /
    • v.28 no.2
    • /
    • pp.121-146
    • /
    • 2005
  • Newcastle disease (ND), infectious bronchitis (IB), low pathogenic avian Influenza (LPAI) and fowl typhoid (FT) have been known as egg drop laying diseases because of the serious layer damage from mass zone layer. In this study, such egg drop laying diseases were investigated. To access this study, we peformed to evaluate antibody titers in serum and isolated bacteria and virus from organs and feces on May, July and September in 2003. The distribution of ND from January to May, IB and LPAI from October to February of the next year, and FT from March to September were inspected by the question survey in 21 farms. ND revealed to be positive rates of 490 to 474 $(96.7\%)$ in May, 510 to 506 $(99.2\%)$ in July and 510 to 510 $(100\%)$ in September with hemagglutination inhibition (HI) test. The mean antibody titers were 10.2, 9.9 and 10.2, respectively. With regard to IB, 484 out of 490 samples $(98.7\%)$ in May, 508 of 510 $(99.6\%)$ in July and 509 of 510 $(99.8\%)$ in September showed positive results and the mean antibody titers were gradually increased with 8.2, 9.0 and 9.4, respectively. According to HI test of LPAI, the positive results were shown in 442 of 480 $(92.1\%)$, 394 of 494 $(79.8\%)$ and 402 of 483 $(83.2\%)$ in May, July and September, respectively The mean antibody titers were decreased with 4.6, 4.3 and 4.0. The distribution of LPAI also elicited the positive rates of 480 to 475 $(99.0\%)$ in May, 494 to 485$(98.2\%)$ in July, 483 to 472 $(97.7\%)$ in September as determined by ELISA and the mean S/P ratio were 2.319, 2.557 and 2.380, respectively. Compared ELISA results with HI test of LPAI the positive results were 480 to 422 $(92.1\%),\;475(99.0\%),\;494\;to\;394 (79.8\%),\;485 (98.2\%)\;and\;483\;to\;402(83.2\%),\;472(97.7\%)$. Therefore, the positive rate determined by ELISA was higher than that of HI test with 6.9, 18.4 and $14.5\%$, respectively. When performed RT-PCR for ND using organ and feces samples, the pathotypes were detected $5(15.6\%)\;in\;May,\; 2(5.3\%) in\;July,\;2(7.1\%)$ in September but there is no samples showing positive band for LPAI. In attempt to isolate Salmonella gallinarum, bacteria were obtained from 4 cases (12.5%) in May, 9 (23.6%) in July, 5 (17.8%) in September. Thus the highest rate for isolation revealed to be shown in July When evaluated the antimicrobial susceptibility to 18 isolated strains of 5. gallinarum, bacteria were sensitive to trimethoprim/sulfamethox$(61.1\%),\;kanamycin\;(55.5\%),\;ampicillin\;(55.5\%)$ and amoxacillin/clavulanic acid $(55.5\%)$, cephalothin $(50.0\%)$, but resistant to penicillin $(88.9\%)$, streptomycin $(88.9\%)$, erythromycin $(83_4\%)$ and tetracycline $(61.1\%)$. According to HI test of ND and LPAI using captured 164 wild Korean tree sparrows (Passer nontanus), the positive rates were $47.6\%\;and\;57.3\%$, and the mean HI titers were 5.32 and 4.02, respectively. 71 $(43.2\%)\;and\;58(35.3\%)$ in captured sparrows also showed more than 4 titers for HI test to ND and LPAI, respectively However, the attempt for isolation of viruses failed in all samples.

Studies on porcine parvovirus inactivated vaccine and titration of serum neutralizing antibody (돼지 parvovirus불활화(不活化) vaccine 및 중화항체가측정(中和抗體價測定)에 관한 연구(硏究))

  • Kwon, Hyock-jin;Yeh, Jae-gil;Lee, Chang-koo
    • Korean Journal of Veterinary Research
    • /
    • v.28 no.2
    • /
    • pp.355-359
    • /
    • 1988
  • A porcine parvovirus inactivated vaccine was prepared and inoculated to 7 piglets and also 8 guinea-pigs, and their serum antibodies were titrated. Twenty-two field serum samples of unvaccinated sows were also tested by SN and HI methods. It was observed that SN test was superior over HI test. Therefore, it is suggested that the SN test could well be used in the detection of serum antibody for PPV in vaccinated pigs.

  • PDF

Development of Real-Time Simulator for a Heavy Duty Diesel Engine (건설기계 디젤엔진용 실시간 시뮬레이터 개발)

  • Noh, Young Chang;Park, Kyung Min;Oh, Byoung Gul;Ko, Min Seok;Kim, Nag In
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.2
    • /
    • pp.203-209
    • /
    • 2015
  • Recently, the portion of electronic control in an engine system has been increasing with the aim of meeting the requirements of emissions and fuel efficiency of the engine system in the construction machinery industry. Correspondingly, the complexity of the engine management system (EMS) has increased. This study developed an engine HiLS system for reducing the cost and time required for function development for the EMS. The engine model for HiLS is composed of air, fuel, torque, and dynamometer models. Further, the mean value method is applied to the developed HiLS engine model. This model is validated by its application to a heavy-duty diesel engine equipped with an exhaust gas recirculation system and a turbocharger. Test results demonstrate that the model has accuracy greater than 90 and also verify the feasibility of the virtual calibration process.

Mobility and Safety Evaluation Methodology for the Locations of Hi-PASS Lanes Using a Microscopic Traffic Simulation Tool (미시교통시뮬레이션모형을 이용한 하이패스 차로 위치별 이동성 및 안전성 평가방법 연구)

  • Yun, Ilsoo;Han, Eum;Lee, Cheol-Ki;Rho, Jeong Hyun;Lee, Soojin;Kim, Sang Byum
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.12 no.1
    • /
    • pp.98-108
    • /
    • 2013
  • The number of Hi-Pass lanes became 793 lanes at 316 expressway tollgates in 2011 due to the increase in the Hi-Pass use. In spite of the increase in the number of Hi-Pass lanes, there have been increased potential risks in tollgates where vehicles using a Hi-Pass lane must weave with other vehicles using a TCS lane. Therefore, there is a need for study on the safety in tollgates. To this end, this study aims at developing a methodology to evaluate the performance measures of diverse location countermeasures of Hi-Pass lanes in an efficient and systematic way. This study measured the mobility, safety and the convenience of installation and operation of Hi-Pass lanes using a microscopic traffic simulation tool, the surrogate safety assessment model and survey. In addition, this study aggregated the above three performance indexes using weight factors estimated using the AHP technique. For the test site, Dongsuwon interchange was selected. After building the microscopic traffic simulation model for the test site, the location countermeasures of Hi-Pass lanes applicable to the test site were compared with each other in terms of the mobility, safety and installing and operating convenience. As a result, there has been no apparent difference in mobility index based on delays. However, the countermeasures where Hi-Pass lanes are located in inside lanes generally showed better safety performance based on the number of conflicts. In addition, countermeasures with neighboring Hi-Pass lanes were favorable in terms of the safety and the convenience of installation and operation. The methodology proposed in this study was found to be useful to support decision makings by providing critical and quantitative information regarding the mobility, safety and the convenience of installation and operation.

Enzyme Linked Immunosorbent Assay for the Detection of Antibody to Avian Infectious Bronchitis Virus (효소면역법에 의한 닭 전염성 기관지염 바이러스 항체검사)

  • 송현제;최정옥
    • Korean Journal of Poultry Science
    • /
    • v.18 no.3
    • /
    • pp.183-196
    • /
    • 1991
  • In order to establish ELISA method to detect antibody against IBV various factors involved were examined. Antigen was prepared from Massachusetts type IBV which is known to be one of serotypes distributed most widely. The virus was grown in embryonated SPF chicken eggs. Allantoic fluid harvested was processed to ultracentrifugation and sucrose density gradient centrifugation to produce a purified antigen The antisera selected from the field samples based on hemagglutination inhibition test were used as the standard positive and negative sera for this study and the results obtained were summarized as follows. 1 , It was found that ELISA test was satisfactory when the purified antigen was coated on the plate in the amount of about 40ng protein per well. In case of the phospholipase treated hemagglutinating antigen it gave satisfactory results when the each well wns coated with 1.2 to 2.5 hemagglutinating unit which was equivalent to 40 to 90ng of protein. 2. There was no significant difference in the ratio of optical density of positive to that of negative serum whether the coated antigen was held for 1 hour at 37$^{\circ}C$ or it was held overnight at 4$^{\circ}C$. The coated antigen could be kept in dried state without change of antigenecity for at least one month of experimental period at 4$^{\circ}C$. 3. There was a big variation in the optical density and P/N values depending on the maker of the plates and on the plate of the same maker. 4. It was found that background optical density was negligible when serum was diluted more than 1:50 and serum dilution of 1:100 appeared to be appropriate as a routine test dilution to screen the antibody. 5. Optical density was fairly constant 15 minutes afterward from the time substrate was treated and during the 4 hours after stopper was treated. 6. There was a low correlation(r=0.42) between ELISA and HI test. However, when 74serum samples were tested for the IBV antibody, 98.7% were found to be positive by both tests in which titers of 2$^{6}$ or more by HI test and P/N values of 1.4 or more by ELISA were considered to be positive, 7 Day-old IBV vaccinated chickens shows a similar antibody decay and rising pattern until 8 weeks of age by the two tests, ELISA and HI.

  • PDF

THE COMPARISON OF RELATIVE RELIABILITY ON BIAXIAL AND THREE POINT FLEXURAL STRENGTH TESTING METHODS OF LIGHT CURING COMPOSITE RESIN (광중합형 레진의 3점 굴곡 강도와 이축 굴곡 강도 측정 방법에 대한 상대적 신뢰도의 비교)

  • Seo, Deog-Gyu;Roh, Byoung-Duck
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.1
    • /
    • pp.58-65
    • /
    • 2006
  • The possibility of applying a hi-axial flexure strength test on composite resin was examined using three point and hi-axial flexure strength tests to measure the strength of the light-cured resin and to compare the relative reliability using the Weibull modulus. The materials used in this study were light-curing restorative materials, $MICRONEW^{TM},\;RENEW^{(R)}$ (Bisco, Schaumburg, USA). The hi-axial flexure strength measurements used the piston-on-3-ball test according to the regulations of the International Organization for Standardization (ISO) 6872 and were divided into 6 groups, where the radius of the specimens were 12mm (radius connecting the 3-balls: 3.75mm), 16 mm(radius connecting the 3-balls: 5mm), and the thickness were 0.5mm, 1mm, 2mn for each radius. The hi-axial flexure strength of the $MICRONEW^{TM}\;and\;RENEW^{(R)}$ were higher than the three point flexure strength and the Weibull modulus value were also higher in all of the bi-axial flexure strength groups, indicating that the hi-axial strength test is relatively less affected by experimental error. In addition, the 2 mm thick specimens had the highest Weibull modulus values in the hi-axial flexure strength test, and the $MICRONEW^{TM}$ group showed no significant statistical difference (p>0.05). Besides the 2mm $MICRONEW^{TM}$ group, each group showed significant statistical differences (p<0.05) according to the thickness of the specimen and the radius connecting the 3-balls. The results indicate that for the 2mm group, the hi-axial flexure strength test is a more reliable testing method than the three point flexure strength test.

Comparison of pooled Versus Individual Sera in Avian Infectious Bronchitis Virus Seroprevalence Study (닭 전염성 기관지염 바이러스의 혈청 유병률 연구에서 개별혈청과 합병혈청의 비교)

  • Kim, Sa-Rim;Kwon, Hyuk-Moo;Sung, Haan-Woo;Pak, Son-Il
    • Journal of Veterinary Clinics
    • /
    • v.23 no.4
    • /
    • pp.416-420
    • /
    • 2006
  • Compare to testing sera individually, pooled-serum testing has considered as a cost-effective method, particularly on a large population-based seroprevalence studies. This study was to determine the relationship between individual sera and pooled sera titers for detection of avian infectious bronchitis virus (IBV) and to evaluate suitability of pooled sera by comparing prevalences estimated from both samples. A total of 5,000 individual samples were collected from 500 flocks in Chungcheong, Gyunsgi, and Kangwon provinces between January 2005 and February 2006. Ten samples were randomly selected from each flock. Five-hundred pooled sera were prepared by mixing equal amount of each 10 individual serum from the original samples. IBV antibody titers were measured by hemagglutination inhibition (HI) test. The least squares regression analysis was performed to construct equation between pooled and mean individual titers. To determine whether the flock is infected 4 arbitrary criteria were used: detection of at least 1 chicken with HI titer ${\ge}$ 9 (criterion 1), detection of at least 2 samples with HI titer ${\ge}$9 (criterion 2), detection of at least 1 sample with HI titer ${\ge}$ 10 (criterion 3), and filially detection of at least 1 sample with HI titer ${\ge}$ 11 (criterion 4). The receiver operating characteristic (ROC) curve was used to examine the cut-off points of pooled titers showing optimal diagnostic accuracy. The area under the curve (AUC), sensitivities (Se), specificities (Sp), and positive (PPV) and negative (NPV) predictive values were calculated. The regression equation between pooled titers (pool) and mean individual titers (mean) was: $pool= 1.2498+0.8952{\times}mean$, with coefficient of determination of 87% (p< 0.0001). The optimal cut-off points of pooled titers were titer 8 for criterion 1 (AUC=0.975, Se=0.883, Sp=0.959, PPV=0.985, NPV=0.728), titer 8 for criterion 2 (AUC=0.969, Se=0.954, Sp=0.855, PPV=0.926, NPV=0.907), titer 9 for criterion 3 (AUC=0.970, Se=0.836, Sp=0.967, PPV=0.978, NPV=0.772), and titer 9 for criterion 4 (AUC= 0.946, Se=0.928, Sp=0.843, PPV=0.857, NPV=0.921). The difference of 'prevalence estimated by individual and pooled sample showed a minimum of 2% for criteria 2 and a maximum of 9.1:% for criteria 3. These results indicate that the use of pooled sera in HI test for screening IBV infection in laying hen flocks is considered as a cost-effective method of testing large numbers of samples with high diagnostic accuracy.