• Title/Summary/Keyword: HEMU

Search Result 107, Processing Time 0.032 seconds

Sound Insulation Performance of the Multi-layered Window Structures for the Express Trains (고속철도 차량용 다층 유리창 구조의 차음성능)

  • Lee, Ho-Jin;Lee, Jung-Hyeok;Park, In-Seok;Kim, Seock-Hyun
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.2256-2262
    • /
    • 2011
  • In this study, sound transmission loss (STL) is investigated on the multi-layered windows used in the KTX-sancheon and next generation HEMU-400x high speed train. Using TLOSS, which is developed as a special purpose STL analysis program, STLs of the multi-layered glass windows are analytically investigated and compared with the mass law result. Window specimens for the two train models are manufactured and intensity transmission losses are measured based on ASTM E2249-02. The problems in aspect of sound insulation are diagnosed on the two window models. The aim of this study is to provide useful data for the improvement of the interior noise in the high speed train.

  • PDF

A Study on Noise Propagation Properties of Hi-Speed Train (고속으로 운행하는 고속철도의 소음 방사특성 연구)

  • Park, Tae-Ho;Han, Jong-Won;Ryu, Hun-Jae;Ko, Jun-Hee;Chang, Seo-Il
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.2934-2940
    • /
    • 2011
  • The railway system in Korea is developing more and more rapidly. After development the next generation hi-speed train(HEMU-400X), Korea can compete against developed country. But, speed increasing will cause the greater rolling and aero dynamic noise. In this study shows that measurement noise of the KTX train by 300kn/h class, and KTX-Sancheon train by 350km/h class. The measurements are carried out on open area and noise protection barrier installed area. The microphones were placed at a distance of 3m from the center line of the track at a height of 0.5m above the upper surface of the rail and at a distance of 7.5m from the center line of the track at a height of each 0.6m above(Max 3.6m) the upper surface of the rail. One microphone was placed at a distance of 25m for check the environmental noise.

  • PDF

Running Performance Analysis for the High-speed Electric Multiple Unit 400km/h Experimental (차세대 고속열차 주행성능해석)

  • Lee, Tae-Hyung;Park, Choon-Soo;Han, In-Soo;Choi, Sung-Hoon;Kim, Sang-Soo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.478-479
    • /
    • 2009
  • The HEMU-400X(High-speed Electric Multiple Unit 400km/h eXperimental) project starts in 2007. It is required to analysis and simulate the train performance throughout the project life cycle for a successful completion of the project. This paper is devoted to the development of a train performance analysis model for the high-speed electric multiple unit 400km/h experimental. The model consist of running resistance model, train model, traction model and braking model. So, this paper represents the results of the train performance analysis.

  • PDF

Rail Surface Defect Detection System of Next-Generation High Speed Train (차세대 고속열차의 레일표면 결함 검출 시스템)

  • Choi, Woo-Yong;Kim, Jeong-Yeon;Yang, Il-Dong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.5
    • /
    • pp.870-876
    • /
    • 2017
  • In this paper, we proposed the automatic vision inspection system using multi-layer perceptron to detect the defects occurred on rail surface. The proposed system consists of image acquisition part and analysis part. Rail surface image is acquired as equal interval using line scan camera and lighting. Mean filter and dynamic threshold is used to reduce noise and segment defect area. Various features to characterize the defects are extracted. And they are used to train and distinguish defects by MLP-classifier. The system is installed on HEMU-430X and applied to analyze the rail surface images acquired from Honam-line at high speed up to 300 km/h. Recognition rate is calculated through comparison with manual inspection results.

A Study on PWM Converter of Auxiliary Power Block for Next Generation High Speed Train (차세대 고속전철용 보조전원장치용 PWM 컨버터에 대한 연구)

  • Jeong, Jeong-Han;Cha, Gil-Ro;Lee, Won-Cheol;Won, Chung-Yuen
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.245-248
    • /
    • 2008
  • This paper gives a description of the mode'ling and control of a single phase PWM(Pulse Width Modulation) converter for HEMU-400X(High-speed Electric Multiple Unit - 400 km/h experiment). The converter is part of a Auxiliary power unit supplied by the 25[kV], 60[Hz] overhead line. A model of the converter in a synchronously rotating reference frame of coordinates is used to develop a new type of control. The control system has separate controllers for the active and reactive current, permitting the free choice of the power factor. This paper proposes a new control method of PWM converter for Auxiliary power unit.

  • PDF

Comparative study on displacement measurement sensors for high-speed railroad bridge

  • Cho, Soojin;Lee, Junhwa;Sim, Sung-Han
    • Smart Structures and Systems
    • /
    • v.21 no.5
    • /
    • pp.637-652
    • /
    • 2018
  • This paper presents a comparative study of displacement measurement using four sensors that are being used in the field: they are a ring gauge, a laser Doppler vibrometer (LDV), a vision-based displacement measurement system (VDMS), and an optoelectronic displacement meter (ODM). The comparative study was carried out on a brand-new high-speed railroad bridge designed to produce displacements within a couple of millimeters under the loading of a high-speed train. The tests were carried out on a single-span steel plate girder bridge two times with different train loadings: KTX and HEMU. The measured displacement is compared as raw and further discussion was made on the measurement noise, peak displacement, and frequency response of four sensors. The comparisonsare summarized to show the pros and cons of the used sensors in measuring displacement at a typical high-speed railroad bridge.

Sound Insulation Performance of the Side Layered Panels in the Next Generation High Speed Train (차세대 고속철도 차량 측면 적층재의 차음성능)

  • Lee, Joong-Hyeok;Lee, Ho-Jin;Park, In-Seok;Kim, Seock-Hyun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.10a
    • /
    • pp.457-462
    • /
    • 2011
  • The sidewall of the HEMU-400x consists of two parts. One is the multi-layered structure including aluminium extruded panel and the other is the double glazed window. When the train runs in a tunnel, the equivalent sound insulation performance of the side wall significantly influences the internal noise levels. In aspect of the sound insulation strategy, it is important to make two parts have similar performance. In this study, the intensity sound transmission loss (ITL) is measured on the specimens of the two parts. Mass law deviation (MLD) is considered in order to compare the sound insulation performance of the two parts in respect of the weight. Contribution of each part to the sound insulation is analyzed and the sound insulation strategy is investigated to reduce the interior noise.

  • PDF

A study on development of Integrated Onboard Signaling System Simulator for High Speed Train (고속철도용 통합차상신호시스템 시뮬레이터 개발에 관한 연구)

  • Han, Jaemun
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.81-82
    • /
    • 2015
  • 차세대 고속철도 기술개발 사업을 통해 개발된 통합차상신호 시스템은 국내에서 운영중인 세가지 신호시스템인 ATP, ATC, ATS의 신호를 모두 처리하면서 열차 운행의 중단 없이 열차 운행구간을 이동하게 된다. 현재 통합차상신호시스템의 신뢰성과 안정성 확인을 위해 차세대 고속철도 시제차인 HEMU-430X에 탑재하여 시운전을 진행중에 있는데, 시운전이 여객열차의 영업운전 사이에 진행되기 때문에 다양한 실험과 검증에 많은 제약이 따른다. 이러한 제약 사항을 해결하고 다양한 실험과 개선 활동을 위해 통합차상신호시스템을 실험실내에서 테스트할 수 있는 통합차상신호시스템용 시뮬레이터의 개발이 필요하게 되었고, 본 논문에서는 통합차상신호시스템용 시뮬레이터 개발에 관한 내용을 다룬다.

  • PDF

Analysis of Current Collection Performance Testing and Result of 350[km/h] Catenary System (350km/h 전차선로 집전성능 시험 및 결과 분석)

  • Heo, Yong-Seok;Lee, In-Hee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.2
    • /
    • pp.365-369
    • /
    • 2016
  • The 350[km/h] catenary system was successfully opened in Honam high speed line. This 350[km/h] catenary system is firstly constructed in South Korea. Therefore the current collection performance of this system should be tested and evaluated by the authority. This paper describes the testings by running of HEMU-430X train and the evaluation criteria and result analysis to determine whether the performance of the catenary is good or not as a verification of catenary-pantograph interface. In detail, the contact force by pantograph, arcs by loss of contact and uplift amount of the catenary support were measured and discussed as a category of the current collection performance.

Study on Numerical Analysis for Ram-Air flow of Cooling Duct on the Propulsion System (추진시스템 냉각유로의 주행풍 유동에 대한 수치해석적 연구)

  • Ryoo, Seong-Ryoul;Jo, Jung-Rae;Jo, Tae-Sik;Kim, Chul-Ju
    • Proceedings of the KSR Conference
    • /
    • 2009.05b
    • /
    • pp.507-513
    • /
    • 2009
  • The cooling technology of power conversion semiconductors in the propulsion system for the HEMU(High Electrical Multi Unit) are applied in water cooling method and phase change method such as the immersed type and the heat pipe type. Both of cooling systems need a condenser and a fan through forced wind to emit that is radiated heat from electric power conversion semiconductor(IGBT) stack effectively, now in the case of Japanese Fastec 360S, is using ram-air that is flowed in establishing cooling passage to propulsion system for cooling of condenser. In this research, it is that achieved the computing numerical analysis using ADINA of commertial program to examine flow characteristics and pressure distribution of ram-air for a condenser in cooling passage.

  • PDF