• Title/Summary/Keyword: HEH

Search Result 84, Processing Time 0.021 seconds

Extraction characteristics of extraction resins containing HEH/EHP (HEH/EHP를 함유(含有)한 추출(抽出)수지의 추출특성(抽出特性))

  • Park, Kye-Sung;Kim, Joon-Soo
    • Resources Recycling
    • /
    • v.15 no.4 s.72
    • /
    • pp.13-18
    • /
    • 2006
  • This study was to investigate the extraction characteristics of extraction resins containing HEH/EHP for Gadolinium solution. The experiments were carried out with the variation of equilibrium pH and initial concentration of Gd. The optimum extraction time was 90 mins on Gd extraction using resin. The extraction ratio(%) was increased by increasing equilibrium pH from pH 1.0 to 2.0. The experimentally measured amounts of Gd on resins at equilibrium agreed well with those predicted using Freundlich's isotherm.

Experimental Investigation on Deformation Capacity of CFT Column to H-Steel Beam Connections (콘크리트충전 각형기둥-H형강보 접합부의 변형능력에 관한 실험적 연구)

  • Kim, Young Ju;Chae, Young Suk;Shin, Kyung Jae;Oh, Young Suk;Moon, Tae Sup
    • Journal of Korean Society of Steel Construction
    • /
    • v.16 no.1 s.68
    • /
    • pp.113-121
    • /
    • 2004
  • A test program was conducted on full-scale steel moment connections constructed using a T-stiffener. In the T-stiffener connection, the beam-to-column connection was reinforced with the horizontal and vertical element of the T-stiffener to resist moment under severe cyclic loads. A total of five specimens were tested in this study together with a concrete-filled tubular(CFT) column(${\sqsubset}-500{\times}500{\times}12$) and a steel beam($H-506{\times}201{\times}11{\times}19$). For the specimens, the T-stiffener was combined with RBS (also known as "Dog-bone") detail or Horizontal Element Hole(HEH) detail constructed to enhance deformation capacity. The test program showed excellent seismic performance for specimens constructed with an RBS or an HEH. except the specimens had brittle failure of VE. The test results also showed that the connections all developed maximum moments at the face of the column. Such moments were at least 15% and as much as 36% larger than the plastic moment capacity of the beam. based on the actual yield stress of the beam steel.

Thermally reused solar energy harvesting using current mirror cells

  • Mostafa Noohi;Ali Mirvakili;Hadi Safdarkhani;Sayed Alireza Sadrossadat
    • ETRI Journal
    • /
    • v.45 no.3
    • /
    • pp.519-533
    • /
    • 2023
  • This paper implements a simultaneous solar and thermal energy harvesting system, as a hybrid energy harvesting (HEH) system, to convert ambient light into electrical energy through photovoltaic (PV) cells and heat absorbed in the body of PV cells. Indeed, a solar panel equipped with serially connected thermoelectric generators not only converts the incoming light into electricity but also takes advantage of heat emanating from the light. In a conventional HEH system, the diode block is used to provide the path for the input source with the highest value. In this scheme, at each time, only one source can be handled to generate its output, while other sources are blocked. To handle this challenge of combining resources in HEH systems, this paper proposes a method for collecting all incoming energies and conveying its summation to the load via the current mirror cells in an approach similar to the maximum power point tracking. This technique is implemented using off-the-shelf components. The measurement results show that the proposed method is a realistic approach for supplying electrical energy to wireless sensor nodes and low-power electronics.

Determination of Rare Earth Elements by Inductively Coupled Plasma Mass Spectrometry with Introduction of Organic Phase Using Ultrasonic Nebulizer (초음파 분무기를 이용한 유기상의 주입에 의한 희토류 원소의 유도결합 플라스마 질량분석법적 정량)

  • Lee, Sang Hak;Son, Bum Mok
    • Analytical Science and Technology
    • /
    • v.15 no.2
    • /
    • pp.127-134
    • /
    • 2002
  • Analytical method to determine rare earth elements which were extracted to organic phase by inductively coupled plasma mass spectrometry(ICP-MS) was investigated. Organic phase which had extracted rare earth elements was directly aspirated into ICP-MS by ultrasonic nebulizer(USN) in order to reduce solvent load to the plasma. Then, the count rate increased when MIBK(methyl isobutyl ketone) was added to EtOH(ethanol) but decreased when 0.03 M HEH(2-ethylhexyl-2-ethylhexyl phosphonic acid, $P_{507}$, PC88A) was added to solvent which mixed MIBK with EtOH. The optimal temperatures of desolvation system were -10 $^{\circ}C$ for the condenser and 150 $^{\circ}C$ for the heating tube. The optimal nebulizer flow rate which gave maximum count rate and minimum reflect power was 0.7 L/min. The optimal pH and extraction time were 4.3 and 10 min for MIBK-0.03 M HEH system. Detection limits which were obtained through calibration curves at the range of 0.2 ${\sim}$ 20 ng/mL were 0.02 ${\sim}$ 0.05 ng/mL under the optimal experimental conditions.

Fabrication of metal nanodots and nanowires by atomic force microscopy nanomachining

  • Lin, Heh-Nan
    • Transactions of the Society of Information Storage Systems
    • /
    • v.3 no.1
    • /
    • pp.43-46
    • /
    • 2007
  • The fabrication of metal nanostructures by a combination of atomic force microscopy nanomachining on a thin polymer resist, metal coating and lift-off is reported. Nanodots with sizes and nanowires with widths ranging between 50 and 100 nm have been successfully created. The present work exemplifies the feasibility and effectiveness of using a single-layer resist in comparison with a two-layer resist. In addition, the localized surface plasmon resonance peaks of the metal nanostructures have been measured and the selective growths of zinc oxide nanowires on the metal nanostructures are demonstrated.

  • PDF

Separation of High Purity Terbium Using Extraction Chromatography (추출 크로마토그래피를 이용한 고순도 테르븀의 분리)

  • Lee, Kwang-Pill;Park, Myoung-Jin;Park, Keung-Shik;Lee, Hueng-Lark;Piao, Zhexiu
    • Analytical Science and Technology
    • /
    • v.12 no.5
    • /
    • pp.370-374
    • /
    • 1999
  • Extraction chromatography was used to scarch optimum separation conditions of terbium. Stationary phase was 2-ethylhexyl-2-ethylhexyl phosphonic acid(HEH[EHP])levextrel (-100~+150 mesh), column size was ${\Phi}20{\times}530mm$ and kept constantly temperature at $50^{\circ}C$, adsorption flow rate of $0.2mL/cm^2{\cdot}min$, elution flow rate of $1.0mL/cm^2{\cdot}min$, column diameter to packing height of 1:15. But to search optimum separation conditions of terbium, it changed the eluent acidity, the loading weight of sample. the composition of sample. In conclusion, acidity was 0.6 N HCl, loading weight of sample was about 5% and composition of sample was $Gd_2O_3(20%)+Tb_4O_7(60%)+Dy_2O_3(20%)$. Moreover purity of separated terbium by ICP-AES analysis was 99.98% in yield of 99.99%.

  • PDF