• Title/Summary/Keyword: HCHO (Formaldehyde)

Search Result 125, Processing Time 0.03 seconds

A Study on Concentration of Formaldehyde in Public Schools at Chung Nam Area (충남지역 초.중.고등학교 교실의 실내 공기 중 포름알데히드(HCHO)의 농도분포에 관한 연구)

  • Hong, Eun-Ju;Jeon, Young-Taek;Lee, Che-Won;No, Sun-Jin;Lee, Jong-Dae;Song, Mi-Ra;Son, Bu-Soon
    • Journal of environmental and Sanitary engineering
    • /
    • v.22 no.2
    • /
    • pp.53-60
    • /
    • 2007
  • A pilot study was conducted in order to investigate the concentration of formaldehyde at elementary school, middle school, the high school (108 classrooms) located in Chungchong-namdo during February - September, 2006. Also, divide by (45 classroom) General Classroom and (63 classrooms) Stateroom. The average concentrations of formaldehyde(HCHO) in the general classroom was high by $22.87\;{\pm}\;20.61\;{\mu}g/m^3$ elementary school, $22.08\;{\pm}\;12.70\;{\mu}g/m^3$ high school, $13.58\;{\pm}\;6.60\;{\mu}g/m^3$ middle school. The average concentrations of formaldehyde(HCHO) in the Stateroom was high by $27.58\;{\pm}\;30.5{\mu}g/m^3$ elementary school, $22.03\;{\pm}\;19.12\;{\mu}g/m^3\;22.87\;{\pm}\;20.61\;{\mu}g/m^3$ middle school, $24.92\;{\pm}\;28.15\;{\mu}g/m^3$ high school. There was correlation between formaldehyde concentrations and temperature, humidity in general classroom (P<0.05).

Sustainable coatings fabricated from inorganic wastes for indoor humidity control and degradation of formaldehyde

  • Shou-Heng Liu;Yu-Rou Lin
    • International conference on construction engineering and project management
    • /
    • 2024.07a
    • /
    • pp.238-241
    • /
    • 2024
  • With the development of living standard, people spend more time indoors, and the diversified home decoration will lead to indoor hazardous gas emission. Among them, formaldehyde (HCHO) is one of the most important sources of indoor air pollution, which is commonly found in building materials as a human carcinogen. To address this issue, we developed highly efficient multifunctional green building coatings (GBC) by TiO2, enhancement silica fume (ESF) and spent fluid catalytic cracking catalysts (sFCCC). Among these prepared GBC, the GBC-0.8 exhibited HCHO removal efficiency of 85.0 % under visible light at ambient temperature, which was much higher than that of commercial coatings (30.8%). In addition, moisture adsorption-desorption carrier tests were executed by different humidity. The humidity control capacity of GBC-0.8 could reach 293.8 g/m2 and demonstrate superior stability after 3 cycles. Compared with pristine TiO2, the addition of ESF and sFCCC showed higher specific surface area and pore size distribution, which was beneficial to improve humidity control and photocatalytic degradation performance. This study provides a promising green method for designing multifunctional green building materials coatings to recycle waste into high-value products and remove HCHO at room temperature

The Characteristics of VOCs and Formaldehyde emitted from the furnitures and frame material of windows and doors (가구 및 목창호재에서 방출되는 유해화학물질의 특성)

  • Park, Yong-Seung;Yoo, Bok-Hee;Cho, Hyun;Hong, Cheon-Hwa
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2004.11a
    • /
    • pp.315-318
    • /
    • 2004
  • In recent days, IAQ(Indoor Air Quality) is regarded as one of the most important environmental factors as well as thermal and acoustic comfort. The purpose of this study was to estimate on effect of indoor air pollution from VOCs and formaldehyde emitted by building materials. As the results, we knew that concentration of Toluene, Xylene, Styrene and HCHO emitted from the furnitures and frame material of windows and doors are high emission factors on indoor air pollution.

  • PDF

Properties of Water-Based Paint According to the Mixing Ratio of Powdered Activated Carbon (분말활성탄 혼입률에 따른 수성도료의 특성)

  • Choi, Byung-Cheol;Kyoung, In-Soo;Lee, Sang-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.11a
    • /
    • pp.48-49
    • /
    • 2020
  • Recently, as people's interest in environmental pollution increases, interest in indoor air pollution as well as outdoors is increasing. Accordingly, this study prepares functional paints by mixing powder activated carbon, which is a porous material, into aqueous paints, and examines the adsorption performance of volatile organic compounds (VOCs) and formaldehyde (HCHO). As a result of the experiment, the concentration of volatile organic compounds (VOCs) and formaldehyde (HCHO) tended to decrease as powder activated carbon was incorporated. It is believed that physical adsorption was achieved by the micropores of powdered activated carbon. However, in the adsorption test method, it is judged that the concentration was affected by the inflow of outside air as the chamber cover was opened to put the test object in the empty chamber where a certain concentration was maintained.

  • PDF

Fabrication and characteristics of La1-xSrxMO3(M = Fe, Co, Mn) formaldehyde gas sensors (La1-xSrxMO3(M = Fe, Co, Mn) 물질을 이용한 포름알데히드 가스센서의 제조와 특성)

  • Kim, H.J.;Choi, J.B.;Kim, S.D.;Yoo, K.S.
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.3
    • /
    • pp.203-209
    • /
    • 2008
  • Thick film formaldehyde (HCHO) gas sensors were fabricated by using $La_1_{-x}Sr_xMO_3$ (M= Fe, Co, Mn) ceramics. The powders of $La_1_{-x}Sr_xMO_3$ (M=Fe, Co, Mn) were synthesized by conventional solid-state reaction method. By using the $La_1_{-x}Sr_xMO_3$ (M=Fe, Co, Mn) paste, the thick-film formaldehyde sensors were prepared on the alumina substrate by silkscreen printing method. The experimental results revealed that $La_1_{-x}Sr_xMO_3$ (M= Fe, Co, Mn) ceramic powder has a perovskite structure and the thick-film sensor shows excellent gas-sensing characteristics to formaldehyde gas (sensitivity of $La_{0.8}Sr_{0.2}FeO_3$, S= 14.7 at operating temperature of $150^{\circ}C$ in 50 ppm HCHO ambient).

Characteristics of Volatile Organic Compounds from Newly Produced Building - Apartment House

  • Lee, Jeong-Joo;Kim, Jeong-Ho;Kim, Shin-Do
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2004.06a
    • /
    • pp.223-226
    • /
    • 2004
  • Building materials emit high concentration volatile organic compounds(VOCs), formaldehyde(HCHO) and other hazardous air pollutants(HAPs) to indoor environment. Average value of VOCs and HCHO emission concentration were $3,770\;{\mu}g/m^3$, $430\;{\mu}g/m^3$ in newly buildings, respectively. VOCs and HCHO emission characteristic are high emission level at initial time and decreased in course of time.

  • PDF

Studies on the Emission control of methanol engine exhaust with modified 3-way catalyst at cold start condition (변형된 삼원촉매에 의한 저온시동조건에서의 메탄올엔진 배가스 정화효과에 관한 연구)

  • 홍종성;정석진
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.9 no.2
    • /
    • pp.160-167
    • /
    • 1993
  • As the major methanol fueled vehicle exhaust components, formaldehyde & methanol conversion over the existing commercial 3-way catalyst was examined in a labolatory tains different Ag loadings on commercial 3-way catalyst, and german commercial catalysts for methanol engine exhaust manufactured by a commercial manufacturer. Silver catalysts were prepared by the wet impregnation of silver nitrate solution on commercial 3-way catalyst. These catalysts were characterized with BET Surface area and pore size distribution. In general, the formaldehyde(HCHO) conversion of the tested catalysts was similar to that of methanol$(CH_3OH)$. At 100$^\circ$C, which is equivalent to the cold start condition, 5wt% Ag cat. showed the most excellent HCHO and $CH_3OH$ conversion. The order of activity for conversion of HCHO & $CH_3OH$ to carbon dioxide and water vapor was as follows ; 5wt% Ag/3-way cat.>2wt% Ag/3-way cat.>german cat. front(1) > german cat. rear(2) > 10wt% Ag/3-way cat.> commercial 3-wat catalyst. However there was no significant activity difference between those tested catalysts in the hot run condition of 400$^\circ$C. Therefore, it could be concluded that the Ag-modified 3-way catalyst was the most effective and practical catalyst system which could be capable of removal the HCHO and methanol at the special condition of low temperature such as cold start condition.

  • PDF

Characterization and Assessment of Indoor Air Quality in Newly Constructed Apartments -Volatile Organic Compounds and Formaldehyde- (신축공동주택의 실내공기질 특성 및 평가 -휘발성 유기화합물 및 포름알데히드 중심으로-)

  • Sim, Sang-Hyo;Kim, Yoon-Shin
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.4 s.91
    • /
    • pp.275-281
    • /
    • 2006
  • Indoor air quality is the dominant contributor to total personal exposure because most people spend a majority of their time indoors. Especially exposure to indoor air can potentially pose a greater threat than exposure to ambient air when indoor environments have sources of contaminants. In this study, volatile organic compounds (VOCs) and formaldehyde (HCHO) within newly constructed apartment have been determined in 27 houses of apartment in Seoul from December 2004 to March 2005. The measured indoor air pollutants were HCHO, volatile organic compounds including benzene, toluene, styrene, xylene, ethylbenzene and sampled on the standard method of Ministry of Environment in Korea. The indoor levels for benzene, xylene, toluene, ethylbenzene, styrene, and HCHO have significant increase trend after 5 hours closing of windows and doors. Levels of measured air pollutants concentrations between living rooms and bedrooms have not shown significant difference. Spearman correlation coefficient among the measured air pollutants ranged from 0.303 to 0.946, indicating similar source in building materials.

A Study on the Mock up Test for Reduction of HCHO Using the Functional Gypsum Board (기능성 석고보드의 폼알데히드(HCHO) 저감성능 평가를 위한 실물시험(Mock up test)연구)

  • Kim, Hea-Jeong;Song, Kyoo-Dong;Lee, Yun-Gyu
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.12
    • /
    • pp.814-819
    • /
    • 2008
  • The purpose of this study was developing the building materials for creation the comfortable IAQ. By reducing formaldehyde(HCHO) known as the main factors of Sick House Syndrome. This material must be revealed the physical and eco-friendly performance, so this study set up the basic standards for building materials. The source of physical performance evaluation is Korea Industrial Standards and the base of environmental ability is the Eco Label considering certificated system related to an apartment house. Because the developed material was satisfied with the established standards, it was tested in mock-up room for obtaining the real date from indoor air. The mock-up test was conducted according environmental standard method for indoor air Quality of the ministry of environment. The result of this study were as follows; the functional building materials had a effect to reduce the formaldehyde concentration for a initial period without wall paper, so additional development is needed for application with the wall paper and the available period.

Investigation of Absorption Cross-Section Effects on the Formaldehyde Column Density Retrieval from Direct Sun Measurement (태양 직달광 관측 자료로부터 포름알데히드 연직 농도 산출 시 흡수단면적이 미치는 영향 연구)

  • Gyeong Park;Jeonghyeon Park;Hanlim Lee
    • Korean Journal of Remote Sensing
    • /
    • v.39 no.5_1
    • /
    • pp.551-561
    • /
    • 2023
  • In this study, we investigated the effects of the spectral fitting window and absorption cross-section on the retrieval of the formaldehyde (HCHO) slant column density (SCD) from the direct-sun measurement of pandora spectrometer system using differential optical absorption spectroscopy (DOAS). Pandora Level 1 data observed at Yonsei University in Seoul from October 12 to 31, 2022 were used. The HCHO column density was retrieved under eight ranges including the spectral fitting window used in the Second Cabauw Intercomparison campaign for Nitrogen Dioxide measuring Instruments (CINDI-2) and seven types of absorption cross-section composition. The spectral fitting window was selected from 336.5 to 359.0 nm with minimum residual and HCHO SCD error. When the nitrogen dioxide (NO2) absorption cross-section at 220 K was added to the cross-section composition used in the CINDI-2 campaign among seven types, the residual and HCHO SCD error were the smallest and the HCHO column density wasstably retrieved. The average HCHO SCD with the highest retrieval accuracy and the values retrieved under other conditions differed from a minimum of 4% to a maximum of 40%.