실내공기질 모델을 이용한 신축공동주택의 VOCs 및 HCHO 배출량 추정 (Estimation of Source Emission Rate on Volatile Organic Compounds and Formaldehyde Using Indoor Air Quality Modeling in New Apartment)

  • 심상효;김윤신;양원호
    • 한국환경과학회지
    • /
    • 제15권10호
    • /
    • pp.929-933
    • /
    • 2006
  • Indoor air quality is the dominant contributor to total personal exposure because most people spend a majority of their time Indoors. Especially when indoor environments have sources of contaminants, exposure to in-door air can potentially pose a greater threat than exposure to ambient air. In this study, estimations of volatile organic compounds and formaldehyde omission rate in indoor environments of new apartments were carried out using mass balance model in indoor environment, because indoor air quality can be affected by source generation, outdoor air level, ventilation, decay by reaction, temperature, humidity, mixing condition and so on. Considering the estimated emission rate of volatile organic compounds and formaldehyde, it Is suggested that new apartment should be designed and constructed in the aspect of using construction materials to emit low hazardous air pollutants.

건축자재에서 발생되는 VOCs와 HCHO의 방출특성에 관한 연구 (The Study on Characteristics of VOCs and Formaldehyde Emissions Rate from Building Materials)

  • 장미;김신도;윤중섭
    • 한국대기환경학회:학술대회논문집
    • /
    • 한국대기환경학회 2003년도 추계학술대회 논문집
    • /
    • pp.261-262
    • /
    • 2003
  • 현대인들은 하루 중 80∼90% 이상의 많은 시간을 실내에서 생활하고 있어 실내에서의 발생되는 오염물질에 대한 특성파악은 무엇보다도 중요하다. 실내오염물질의 종류와 발생원은 매우 다양하며, 최근에는 산업발달과 더불어 수 많은 종류의 새로운 복합화합물질들이 발생되고 있다. 신축건물에 사용되는 건축자재는 휘발성유기화합물(VOCs)과 포름알데히드(HCHO)등의 다양한 유해화학물질들을 방출하고 실내공기질을 악화시키는 것으로 조사되고 있다. (중략)

  • PDF

액상환원 기반 Pt/TiO2 촉매 제조를 이용한 포름알데히드 상온 산화 반응 특성 연구 (A Study on the Characteristics of a Pt/TiO2 Catalyst Prepared by Liquid-Phase Ruduction for Formaldehyde Oxidation at Room Temperature)

  • 김재헌;장영희;김거종;김성철;김성수
    • 공업화학
    • /
    • 제34권6호
    • /
    • pp.612-618
    • /
    • 2023
  • 현대 사회는 일상생활 중 80% 이상을 실내에서 생활하고, 생활수준의 향상으로 실내오염물질 노출에 대한 유의가 필요하다. 본 연구에서는 실내오염물질 중 하나인 포름알데히드(HCHO)를 별도의 빛 또는 열 없이 상온에서 제거할 수 있는 액상환원법 기반 Pt/TiO2 촉매의 성능 및 반응 특성을 조사하였다. 활성실험을 통해, 동일한 방법으로 제조된 촉매라도 TiO2 종류에 따라 약 40~80%의 서로 다른 활성을 나타냄을 확인하였다. XRD, BET, XPS 분석을 통해 지지체의 입사 사이즈, 결정구조, 비표면적 및 O/Ti molar ratio를 조사하였고, 지지체 자체의 물성과 성능 간 상관성은 미미함을 확인하였다. HCHO 산화 반응 경로를 조사하기 위해 일산화탄소를 활용한 In situ DRIFT 분석과 H2-TPR을 수행하였다. 그 결과, 촉매의 성능이 활성금속의 산화상태 및 흡착종의 흡탈착 특성에 지배받음을 확인할 수 있었다.

천안지역 일부 다중이용시설의 포름알데히드 농도에 관한 연구 (A study on the concentration of formaldehyde in public Facilities in Cheon-An area)

  • 전혜리;조수연;조혜란;조태진;박종안;손부순
    • 환경위생공학
    • /
    • 제24권2호
    • /
    • pp.1-8
    • /
    • 2009
  • This study was conducted at a Terminal, a Parking Lot, an Underground shopping center, a Funeral hall and a Hospital waiting room of Cheon An area in August 2008 to examine the concentration level of HCHO(formaldehyde). The concentration level of the remodeled sites were $39.4\;{\pm}\;12.0\;{\mu}g/m^3$ in the terminal, $32.7\;{\pm}\;7.3\;{\mu}g/m^3$ in the parking, and $97.8\;{\pm}\;29.4\;{\mu}g/m^3$ in the underground shopping center. The underground shopping center had the highest level and followed by the terminal and the parking. On the contrary, the site remodeling had the level of $17.7\;{\pm}\;12.4\;{\mu}g/m^3$ in the funeral hall and $17.9\;{\pm}\;0.6\;{\mu}g/m^3$ in the hospital waiting room. The funeral hall had highest level than that of the hospital waiting room. Both the remodeled sites and the not remodeled site had concentration level of HCHO below the standard level, but it was higher in the remodeled sites. There were no relations among the HCHO, the temperature and the humidity in facilities of Cheon An area.

아파트 리모델링 전.후의 휘발성유기화합물 농도 변화 (The Concentration Ascension of Volatile Organic Compounds after Remodeling in Apartment Houses)

  • 최윤정;신해철;심현숙
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2006년도 추계학술발표대회 논문집
    • /
    • pp.287-290
    • /
    • 2006
  • The purposes of this study were to make clear the present condition of the TVOC and HCHO concentration after remodeling in apartment houses and to analyze the relation of concentrated ascension and remodeling elements. The field measurements of TVOC and HCHO concentration were carried out in 4 subject apartment houses according to the Korea Test Method Standard for Indoor Air Quality. The results are as follows; the TVOC concentration after remodeling ranged from mean 0.35ppm to mean 5.08ppm and increased of 0.35$^{\sim}$5.08ppm. The concentration of 3 subjects exceeded the Indoor Air Quality Management standard for the newly-built apartment houses (0.7ppm). The HCHO concentration after remodeling ranged from mean 0.13ppm to mean 0.43ppm and increased of 0.06$^{\sim}$0.26ppm. The concentration of 2 subjects exceeded the Standard (0.16ppm). As results of analysis on the relation of concentrated ascension and remodeling elements, the amount and the types of finishing materials and adhesives affected concentrated ascension. Also, production method for installed or purchased furniture had certain effect on the TVOC and HCHO concentration ascension.

  • PDF

신축 및 리모델링 유치원의 휘발성유기화합물 농도 실태 (Actual State of TVOC and HCHO Concentration in Newly Built or Remodeled Kindergarten)

  • 최윤정;박은비;안지선
    • 한국생활과학회지
    • /
    • 제18권6호
    • /
    • pp.1363-1374
    • /
    • 2009
  • The purpose of this study was to determine the actual state of the indoor air quality in newly built or remodeled kindergartens by TVOC and HCHO concentration and teachers' responses. The field measurements on the levels of TVOC and HCHO were carried out in six classrooms of newly built or remodeled kindergartens before their opening. The interviews with teachers of subject kindergartens were carried out at the end of the first semester. The contents of the interviews were teachers' subjective responses and symptoms of the kindergarten pupils on the Sick New-School Syndrome. The results are as follows; the mean value of TVOC concentration in the classrooms of kindergartens ranged from 0.10ppm to 0.42ppm, which can theoretically exert a harmful influence on residents. The mean value of HCHO concentration ranged from 0.00ppm to 0.03ppm, which does not exceed the standard. The TVOC concentrations of the more ventilated kindergartens were lower than the others. Also, the classrooms with high concentrations of TVOC showed negative responses or symptoms in teachers and kindergarten pupils.

위성자료와 다중회귀분석법을 이용한 아시아 주요도시의 포름알데하이드 칼럼농도 추정연구 (First-time estimation of HCHO column in major cities over Asia using multiple regression with satellite data)

  • 최원이;홍현기;박준성;이한림
    • 대한원격탐사학회지
    • /
    • 제31권6호
    • /
    • pp.523-530
    • /
    • 2015
  • 본 연구에서는 다중회귀분석법과 Ozone Monitoring Instrument(OMI), Moderate Resolution Imaging Spectroradiometer(MODIS) 자료를 이용하여 2005년 1월부터 2008년 7월 사이 아시아 주요도시 지역의 포름알데하이드 층적분농도를 동북아시아에 위치한 3개도시(베이징, 서울, 도쿄)와 동남아시아에 위치한 3개도시(뉴델리, 다카, 방콕)에서 처음으로 추정하였다. 동북아시아의 3개 도시에서는 OMI로 측정된 포름알데하이드의 층적분농도($HCHO_{OMI}$)와 다중회귀분석방법으로 추정된 포름알데하이드의 층적분농도($HCHO_{MRM}$) 사이의 높은 상관성(0.78 < $R^2$ < 0.82)을 보였다. 동남아시아의 주요도시에서는 동북아시아 지역에 비해 $HCHO_{OMI}$$HCHO_{MRM}$사이의 낮은 상관성을 발견 할 수 있었다. 이외에도, 다중회귀분석법의 편중되지 않은 평가를 위하여, 다중회귀분석식을 도출해내기 위한 모델링 그룹과 다중회귀분석법의 성능을 보여줄 검증그룹으로 나누어 다중회귀분석법의 성능을 평가하였다. 본 연구는 아시아 일부 지역에서 다중회귀 분석법이 포름알데하이드 칼럼농도 추정에 있어 위성 관측이 어려울 경우 대안으로 활용될 수 있음을 제시하고 있다.

대학교 신축기숙사의 휘발성유기화합물 농도 및 새집증후군 반응 (The Actual State of TVOC and the Responses of Sick House Syndrome in Newly Built University Dormitory)

  • 최윤정;김정재;장윤정;오예슬
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2008년 추계학술발표대회 논문집
    • /
    • pp.255-260
    • /
    • 2008
  • The purposes of this study were to determine the actual state of the indoor air quality by TVOC concentration and residents' responses and to analyze the influencing factors of IAQ in newly built university dormitory. The field measurements on the levels of TVOC and HCHO were carried out three times at an interval of 4 weeks in 3 rooms of a dormitory. The questionnaire survey on the residents that inquired into the lifestyle, the consciousness related to IAQ, and the responses of SHS was fulfilled. According to the results, the level of TVOC was approximately $0.14{\sim}18.5ppm$ and HCHO was $0.23{\sim}6.89ppm$ during 3 month since construction completion, which are seriously in excess of standard level, and seemed to be on the decrease as time goes by. The factors influencing the differences of the levels of TVOC or HCHO were the amount of ventilation including infiltration, heating temperature, relative humidity, or the use of living things including chemical. However, the residents rarely felt the responses of SHS and did not be conscious of the importance of ventilation.

  • PDF

대학교 신축 기숙사의 휘발성유기화합물 농도 및 새집증후군 반응 (The Actual State of TVOC and the Responses of Sick House Syndrome in Newly Built University Dormitory)

  • 최윤정;오예슬;장윤정;김정재
    • 한국주거학회논문집
    • /
    • 제20권6호
    • /
    • pp.135-143
    • /
    • 2009
  • The purposes of this study were to determine the actual state of the indoor air quality by measuring TVOC Concentration and surveying residents' responses in a newly built university dormitory and to analyze the influencing factors of IAQ. Field measurements on the concentrations of TVOC and HCHO were carried out three times at 4 week intervals in 3 rooms of a dormitory. A questionnaire survey was conducted on residents which inquired into the resident's lifestyle, their consciousness of IAQ, and the responses to SHS. According to the results, TVOC concentrations were 0.14~18.5 ppm and HCHO concentrations were 0.23~6.89 ppm during the 3 months following the completion of construction, showing a serious state in which standard levels are exceeded, though these levels seemed to decrease over time. The factors influencing the differences in the levels of TVOC and HCHO were the ventilation volume including infiltration, the heating temperature, relative humidity, or the use of living matter that include chemical ingredients. However, the residents rarely felt the symptoms of SHS and were not conscious of the importance of ventilation.

식물-바이오필터에 의한 토양수분 안정화 및 실내 공기질 향상 (Stabilization of Soil Moisture and Improvement of Indoor Air Quality by a Plant-Biofilter Integration System)

  • 이창희;최봄;천만영
    • 원예과학기술지
    • /
    • 제33권5호
    • /
    • pp.751-762
    • /
    • 2015
  • 본 연구는 평면형 바이오필터를 설계하여 제작하고 이 바이오필터에 디펜바키아(Dieffenbachia amoena 'Marianne')의 식재 여부에 따라 환기 용량을 제어할 수 있는 토양 수분 안정화 정도를 측정하고 미세먼지, 휘발성 유기화합물 및 포름알데히드(HCHO)와 같은 실내공기 오염물질에 대한 바이오필터의 제거율을 비교하였다. 실험 결과 디펜바키아의 식재 여부에 관계없이 모두 일정한 상대습도, 온도 및 토양 수분 함량을 나타내었고 이 바이오필터에 식재한 디펜바키아도 정상적으로 생육하였다. 바이오필터에 의한 미세먼지 제거율을 보면, 미세먼지(PM10)와 초미세먼지(PM2.5)의 입자 수는 토양만 있는 경우 각각 30%와 2% 이상 제거되었고, 디펜바키아를 식재한 경우도 각각 40%와 4% 이상 제거되었다. 미세먼지(PM10) 무게에 따른 제거율은 토양만 있는 경우 4% 이상, 디펜바키아를 식재한 경우 20% 이상으로 나타났다. 토양만 채운 바이오필터는 xylene, ethylbenzene, toluene, total volatile organic compounds(T-VOCs)를 63% 이상 제거하였으나 benzene은 22% 이상, HCHO는 38% 이상을 제거하였다. 디펜바키아를 식재한 바이오필터는 xylene, ethylbenzene, toluene, T-VOCs를 72% 이상 제거하였고 benzene과 HCHO도 39% 이상 제거하였다. 따라서 식물과 바이오 필터를 결합한 시스템은 미세먼지의 제거보다 휘발성 유기 화합물의 제거에 대한 효과가 더 높은 것으로 나타났다. 본 연구에서 제작한 평면형 바이오필터는 실내 공기질 정화에 매우 효과가 있는 것으로 나타났으며, 식물과 바이오필터를 결합하였을 때 그 효과는 더욱 큰 것으로 확인하였다.