• Title/Summary/Keyword: HA/PCL

Search Result 27, Processing Time 0.027 seconds

Effect of Matrigel for Bone Graft using Hydroxyapatite/Poly $\varepsilon$-caprolactone Scaffold in a Rat Calvarial Defect Model (랫드의 두개골결손부 모델에서 HA/PCL 지지체를 사용한 골이식 시 Matrigel의 효과)

  • Kim, Se-Eun; Shim, Kyung-Mi;Kim, Seung-Eon;Choi, Seok-Hwa;Bae, Chun-Sik;Han, Ho-Jae;Kang, Seong-Soo
    • Journal of Veterinary Clinics
    • /
    • v.27 no.4
    • /
    • pp.325-329
    • /
    • 2010
  • The osteogenic potential of hydroxyapatite/poly $\varepsilon$-caprolactone composite (HA/PCL) scaffolds with matrigel was evaluated in a rat calvarial defect model. Calvarial defect formation was surgically created in Sprague Dawley rats (n = 18). HA/PCL scaffold was grafted with matrigel (M-HA/PCL group, n = 6) or without matrigel (HA/PCL group, n = 6). A critical defect group (CD group, n = 6) did not received a graft. Four weeks after surgery, bone formation was evaluated with radiography, micro computed tomography (micro CT) scanning, and histologically. No bone tissue formation was radiographically evident in the CD group. Bone tissue was radiographically evident in the HA/PCL and M-HA/PCL groups, however, there was more bone-similar opacity in the M-HA/PCL group. Micro CT analysis revealed that the bone volume of the M-HA/PCL group was higher than the HA/PCL group, however, no significant difference was found between the HA/PCL and M-HA/PCL groups. Bone mineral density in the M-HA/ PCL group was significantly higher than in the HA/PCL group (p < 0.05). Histologically, new bone was formed only from existing bone in the CD group, showing concavity without bone formation in the defect. In the HA/PCL group, new bone formation was only derived from existing bone, while in the M-HA/PCL group the largest bone formation was observed, with new bone tissue forming at the periphery of existing bone and around the HA/PCL scaffold with matrigel. The results indicate that the combination of HA/PCL scaffold with matrigel may be an effective means of enhancing bone formation in critical-sized bone defects.

Bone Morphogenic Protein-2 (BMP-2) Immobilized Biodegradable Scaffolds for Bone Tissue Engineering

  • Kim, Sung-Eun;Rha, Hyung-Kyun;Surendran, Sibin;Han, Chang-Whan;Lee, Sang-Cheon;Choi, Hyung-Woo;Choi, Yong-Woo;Lee, Kweon-Haeng;Rhie, Jong-Won;Ahn, Sang-Tae
    • Macromolecular Research
    • /
    • v.14 no.5
    • /
    • pp.565-572
    • /
    • 2006
  • Recombinant human bone morphogenic protein-2 (rhBMP-2), which is known as one of the major local stimuli for osteogenic differentiation, was immobilized on the surface of hyaluronic acid (HA)-modified poly$(\varepsilon-caprolactone)$ (PCL) (HA-PCL) scaffolds to improve the attachment, proliferation, and differentiation of human bone marrow stem cells (hBMSCs) for bone tissue engineering. The rhBMP-2 proteins were directly immobilized onto the HA-modified PCL scaffolds by the chemical grafting the amine groups of proteins to carboxylic acid groups of HA. The amount of covalently bounded rhBMP-2 was measured to 1.6 pg/mg (rhBMP/HA-PCL scaffold) by using a sandwich enzyme-linked immunosorbant assay. The rhBMP-2 immobilized HA-modified-PCL scaffold exhibited the good colonization, by the newly differentiated osteoblasts, with a statistically significant increase of the rhBMP-2 release and alkaline phosphatase activity as compared with the control groups both PCL and HA-PCL scaffolds. We also found enhanced mineralization and elevated osteocalcin detection for the rhBMP-2 immobilized HA-PCL scaffolds, in vitro.

Biodegradable implants for orbital wall fracture reconstruction

  • Jang, Hyeon Uk;Kim, So Young
    • Archives of Craniofacial Surgery
    • /
    • v.21 no.2
    • /
    • pp.99-105
    • /
    • 2020
  • Background: Due to the different handling properties of unsintered hydroxyapatite particles/poly-L-lactic acid (uHA/PLLA) and polycaprolactone (PCL), we compared the surgical outcomes and the postoperative implantation accuracy between uHA/PLLA and PCL meshes in orbital fracture repair. Methods: Patients undergoing orbital wall reconstruction with PCL and uHA/PLLA mesh, between 2017 and 2019, were investigated retrospectively. The anatomical accuracy of the implant in bony defect replacement and the functional outcomes such as diplopia, ocular motility, and enophthalmos were evaluated. Results: No restriction of eye movement was reported in any patient (n= 30 for each group), 6 months postoperatively. In the PCL group, no patient showed diplopia or enophthalmos, while the uHA/PLLA group showed two patients with diplopia and one with enophthalmos. Excellent anatomical accuracy of implants was observed in 27 and 22 patients of the PCL and uHA/PLLA groups, respectively. However, this study showed that there were neither any significant differences in the surgical outcomes like diplopia and enophthalmos nor any complications with the two well-known implants. Conclusion: PCL implants and uHA/PLLA implants are safe and have similar levels of complications and surgical outcomes in orbital wall reconstruction.

Poly-${\varepsilon}$-caprolactone(PCL) / Polyvinyl chloride(PVC) 블렌드의 기계적 성질 및 생분해성

  • Seo, Hae-Jeong;Ha, Gi-Ryong;Gang, Seon-Cheol
    • 한국생물공학회:학술대회논문집
    • /
    • 2002.04a
    • /
    • pp.379-380
    • /
    • 2002
  • Biodegradable polymers have been regarded as a good alternative to solve the plastic waste problems caused by nondegradable synthetic polymers such as polyethylene and polystyrene. In the soil environment, plastics are mainly being used as a mulching film for agricultural purposes. In this research, the miscibility, tensile properties and biodegradation effect of poly-${\varepsilon}$-caprolactone(PCL) with polyvinyl chloride(PVC) have been studied. After 8 weeks of biodegradation, PCL/PVC(9/91) blend surface showed newly formed many holes. Consequently, the antiplasticization phenomenon and biodegradation were observed in the PCL/PVC blends. It was confirmed that a test for general biodegradation condition can be applied to plastic biodegradation in soil.

  • PDF

Characterization of HA/PCL composite scaffolds fabricated by layer manufacturing technology

  • Kim, Seung-Eon;Hyun, Yong-Taek;Yun, Hui-Suk;Yoon, Taek-Rim;Heo, Su-Jin;Shin, Jung-Woog
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1409-1410
    • /
    • 2008
  • Layer manufacturing technology has been recently spotlighted as a promising candidate to fabricate porous scaffolds for tissue engineering, because it can provide three dimensional interconnectivity and different pore structures and on-demand scaffold design. This study aims to fabricate HA/PCL composite scaffolds for bone tissue engineering by a layer manufacturing technology, paste extruding deposition, and to characterize in vitro and in vivo biocompatibilities of the scaffolds. This study discusses the mechnical properties, proliferation and differentiation of osteogenic cells, and tissue in-growth and bone regeneration behavior using animal models.

  • PDF

Mechanical Properties and Antiplasticization Phenomena of Poly(${\varepsilon}$-caprolactone)(PCL)/Poly(vinyl chloride)(PVC) Blends (폴리카프로락톤 (PCL)/폴리염화비닐(PVC) 블렌드의 기계적 성질 및 반가소화 현상)

  • Kim, Wook-Soo;Kim, Il-Hyoung;Kang, Sun-Chul;Mori, Tetsuo;Tsuda, Yusuke;Ha, Ki-Ryong
    • Polymer(Korea)
    • /
    • v.25 no.4
    • /
    • pp.521-527
    • /
    • 2001
  • The miscibility, molecular interaction and tensile properties of the blends of poly (${\varepsilon}$-caprolactone) (PCL) with poly(vinyl chloride) (PVC) have been studied. The measured glass transition temperature values of PCL/PVC blends were found to be well fitted by Fox equation. We found that PCL/PVC blends are amorphous up to 23% PCL content. The blends showed the highest Young's modulus and yield strength at 5% PCL content and the highest tensile strength at 11% PCL content. The blends with low contents of PCL(up to 13%) show increased tensile strength and decreased elongation of PCL/PVC blends. Consequently, the antiplasticization phenomenon is observed in the PCL/PVC blends.

  • PDF

Processing Optimization of PCL/TCP Composites Produced by Selective Laser Sintering (SLS에 의한 PCL/TCP 복합체 제작공정변수의 최적화)

  • Chung, Ha-Seung;Jee, Hae-Seong
    • Korean Journal of Computational Design and Engineering
    • /
    • v.13 no.6
    • /
    • pp.421-428
    • /
    • 2008
  • This article investigates the fabrication of polycaprolactone (PCL) composites filled with different volume fractions (10-30%) of tricalcium phosphate (TCP) by selective laser sintering (SLS) for tissue engineering scaffolds. Optimal processing parameters for each composition were developed by design of experiments (DOE). Specimens for compressive testing for each composition were fabricated and tested. The results showed that the compressive modulus increases as a function of TCP volume fraction. The experimentally measured compressive moduli were compared with moduli predicted by Halpin's theoretical model and were found to be in excellent agreement. This result proved that experimentally determined processing parameters for each composition were well optimized.

Fabrication of Blended PCL/β-TCP Scaffolds by Mixture Ratio of β-TCP using Polymer Deposition System (폴리머 적층 시스템을 이용한 β-TCP 혼합 비율에 따른 PCL/β-TCP 인공지지체의 제작)

  • Ha, Seong-Woo;Kim, Jong Young
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.31 no.9
    • /
    • pp.791-797
    • /
    • 2014
  • Abstract Scaffold used as a carrier of the cell has been actively conducted using plenty of technology in tissue engineering. ${\beta}$-tricalcium phosphate (${\beta}$-TCP) material has shown good biocompatibility and osteoconductive ability when it was implanted as a bone graft substitute in osseous defect in human and animal studies for bone regeneration. In this study, we fabricated the blended polycaprolactone (PCL) and ${\beta}$-TCP scaffold by the polymer deposition system (PDS). The PCL/${\beta}$-TCP scaffold was fabricated at a temperature of $110^{\circ}C$, pressure of 650 kPa, and scan velocity of 100 mm/sec. The Overall geometry and size of the scaffold were fixed circle type with a diameter of 10 mm and a height of 4 mm. PCL/${\beta}$-TCP scaffold was observed by scanning electron microscopy. Cell attachment and proliferation of the scaffold containing 30 wt% ${\beta}$-TCP was superior to those containing 10 wt% and 20 wt% ${\beta}$-TCP.

Drug Release from Bioerodible Hydrogels Composed of $Poly-{\varepsilon}-Caprolactone/poly(Ethylene{\;}glycol)$ Macromer Semiinterpenhetrating Polymer Networks

  • Kim, Sung-Ho;Ha, Jeong-Hun;Jung, Yong-Jae;Cho, Chong-Su
    • Archives of Pharmacal Research
    • /
    • v.18 no.1
    • /
    • pp.18-21
    • /
    • 1995
  • Poly(ethylene glycol)(PEG) macrocers teminated with acrylate groups and semi-interpenetrating polymer networks (IPNs) composed of poly-.epsilon.-capolactone(PCL) and PEG macromer were syntheswized with the aim of obtaining a bioerodible hydrogel that could be used to release drugs for implantable delivery system. Polymerization of PEG macromer resulted in the formation of cross-linked gels due to the multifunctionality of macromer. Non-crosslinked PCL chains were interpenetrated into the cross-linked three-dimensions networks of PEG. The IPNs, largw drug loading lower concentration of PEG macromer in the IPNs concentration and the higher molecular weight of PEG macromer. Also, 5-FU was more fast released than hydrocortisone to the increased water solubility.

  • PDF

Intracellular delivery and anti-tumor activity of polyethyleneglycol liposomes containing cationic lipid (양이온성 지질이 포함된 PEG 리포솜의 세포내 이입 및 항암효력 평가)

  • Jung, Soon-Hwa;Kim, Sung-Kyu;Jung, Suk-Hyun;Seong, Ha-Soo;Cho, Sun-Hang;Shin, Byung-Cheol
    • Journal of Pharmaceutical Investigation
    • /
    • v.38 no.3
    • /
    • pp.163-169
    • /
    • 2008
  • Liposomes are spherical vesicles composed of lipid bilayer membranes. However, the conventional liposomes have been found to be plagued by rapid opsonization and taken up by the reticuloendothelial system (RES), resulting in shortened circulation time and limited intracellular uptake to target cell. In this study, polyethyleneglycol-cationic liposomes (PCL) containing cationic lipid and DSPE-mPEG were prepared by thin film cast-hydration method. The PEG liposomes had approximately $97.0{\pm}1.3\;nm$ of mean particle diameter and $-21.7{\pm}1.2\;mV$ of zeta potential value. PCL had $96.4{\pm}1.8\;nm$ of mean particle diameter and $-8.7{\pm}1.1\;mV$ of zeta potential value with a decrease of about 10 mV compared to the PEG liposomes. Loading of model drug, doxorubicin (DOX), in liposomes were carried out by using remote loading method and the loading efficiency of DOX in liposomes was about $95.0{\pm}1.9%$. Intracellular uptake and cytotoxicity of PCL were higher than that of PEG liposomes to murine B16F10 melanoma cells. In addition, anti-tumor activity of PCL was similar to that of PEG liposomes on growth of A549 human lung carcinoma in BALB/c mice. Consequently, PCL modified with cationic lipid may be applicable as anticancer drug carriers that can increase intracellular uptake and therapeutic efficacy.