• Title/Summary/Keyword: H1*-H2* measure

Search Result 809, Processing Time 0.031 seconds

An Observational Study on the Temperature Rising Effects in Water Warming canal and Water Warming Pond (온수로 및 온수지에서의 수온상승효과에 관한 조사연구)

  • 홍종백;홍성범
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.32 no.3
    • /
    • pp.31-38
    • /
    • 1990
  • The power water flowed out from the multipurpose darn influences the ecosystem approximately because of the low water temperature. An appropriate counter measure to the rising water temperature is needed for growing crops especially when the temperature is below 18˚C in the source of the irrigation water This observational study is practiced in Yong-Doo water warming canal and pond in the down stream of Choong-Ju multipurpose dam and is practiced for analyse and compare the rising effects in actural water temperature by actual measurement with the rising effects of planned water temperatuer by the basic theoritical method and for the help to present the direction in plan establishment through investigate the results afterwards. The results are as follows. 1.The degree of the rise of the water temperature can be decided by $\theta$x=$\theta$o +K L--v.h (T-$\theta$˚)Then, K values of a factor representing the characteristics of the water warming canal were 0.00002043 for the type I. and 0.0000173 for the type II. respectively. 2.A variation of water temperature which produced by the difference effective temperature and water temperature in the water warming canal was $\theta$x1 = 16.5 + 15.9(1-e -0.00018x), $\theta$x2 =18.8 + 8.4( 1-e -0.000298x)for the type I. and $\theta$x, = 19.6 + 12.8 ( 1-e -0.00041x) for the type II. 3.It was shown that the effects of the rise of water temperature for the type I. water warming canal were greater than that of type II. as a resultes of broadening the surface of the canal compared with the depth of water, coloring the surface of water canal and installing the resistance block. 4.In case of the type I. water warming canal, the equation between the air temperature and the degree of the rise of water temprature could be made ;Y= 0.4134X + 7.728 In addition, in case of the type II. water warming canal, the correlation was very low. 5.A monthly variation of the water temperature in the water warming canal was the highest in August during the irrigation period and the water temperature rose with the air temperature until August. However, it was blunted after then. 6.A rising degree of water temperature of the practical value in the water warming pond was higher than that of the theoritical equation by 69% for the type I. and 57% for the type II. Accordingly, it was possible to acquire the result near the practical value.$\theta$w-$\theta$o=[1-exp{ -h(1+2$\psi$) . X($\theta$w-$\theta$0)XC Here, C values are 1.69 for the type I. and 1.57 for the type II. 7.It was shown that the effect of the rise of water temperature was favorable when the thermal absorption was to be good by coloring the surface of the water warming pond and removing the bottom osmosis. 8.By enlarging the surface of water in comparison with the depth, and by having dead area of water in the water warming pond, this structure in the water warming pond is helpful for the rise of water temperature.

  • PDF

Effects of one-to-one Labor Support on Labor Pain, Labor Stress Response, Childbirth Experience and Neonatal Status for Primipara (일대일 분만지지간호가 초산모의 분만동통, 분만스트레스 반응, 분만경험 및 신생아 상태에 미치는 효과)

  • Hur, Myung-Haeng
    • Women's Health Nursing
    • /
    • v.7 no.2
    • /
    • pp.188-202
    • /
    • 2001
  • This study was designed to investigate the effect of one-to-one labor support on labor pain, labor stress response, childbirth experience and neonatal status for primipara by a quasi experiment (nonequivalent control group pretest-posttest design), from April 30, 1999 to February 20, 2000. The subjects of this experiment consisted of eighty two primipara with single gestation, full term, uncomplicated pregnancies. Forty one were in the experimental group and forty one in the control group. Their mean age was 25.95 years, their mean gestation period was 39.9 weeks. A caring package of one-to-one labor support had three components. Physical support consisted of massage, back pressure, touch. Emotional support was provided by a continuous nurse's presence, acceptance and encouragement. Informational support involved teaching breathing skills, relaxation skills and knowledge about the labor process. Data assessed labor pain, pulse rate and blood pressure to measure labor stress response. Also, in measuring the value of labor stress response, plasma epinephrine, plasma norepinephrine and serum cortisol were measured. In the 24 hours after birth, the data for the postpartum mother's childbirth experiences was collected. Umbilical cord arterial blood pH, one minute and five minute Apgar score were measured after birth. Data was analyzed by t-test, $x^2$-test, repeated measures ANOVA, ANCOVA with SAS Program. The results were as follows; 1. Labor pain was significantly low in the experimental group(P=.016). 2. No significant group effects were found, but significant time effects were found for plasma epinephrine, norepinephrine, serum cortisol, pulse rate and blood pressure. 3. The childbirth experience of the experimental group was significantly more positive than the control group (P = .005). 4. The umbilical cord arterial blood pH of the experimental group was significantly higher than the control group(P=.014). There was no significant difference between the two groups in neonatal one minute and five minute Apgar scores. In conclusion, these findings indicate that one-to-one labor support could be effective in decreasing labor pain, and increasing positive childbirth experiences, also increasing the neonatal umbilical cord arterial blood pH for primipara. So, one-to-one labor support could be applied as an effective nursing treatment for primipara.

  • PDF

A Study for Testing Validity of Korean Pain Measurement Tool (국어통증척도의 타당도 연구)

  • 김주희
    • Journal of Korean Academy of Nursing
    • /
    • v.16 no.1
    • /
    • pp.81-88
    • /
    • 1986
  • The main purpose of this study was to clarify the validity with patient's general background of Korean Pain Measurement tool. The subjects of this study were 195 patient from the 8 Med-Surgical wards in H. University Hospital in Seoul. The study was conducted over a 40 day period from Oct. 5, 1985 to Nov. 15, 1985. All patients had pain. Korean Pain Measurement tool and simple discriptive pain scale as Graphic Rating Scale were used to measure the pain, The Pearson Correlation Coefficient test was exercised to measure the correlation between the two kinds of pain tools. To clarify the Sensitivity of Korean Pain tool was used frequency with patient's response. To compare the difference in Pain levels with patient's general background, ANOVA and t-test was employed. To compare the difference in pain levels existed due to pain area of the body used mean numbers. The outcome of the study was as follows : 1. A positive correlation did exist between two pain measurement tools. (r=.2028∼.7768, p <0.002) 2. The sensitive subclass in Korean Pain Measurement tools was 7 subclass. The 7 subclass are inflammatory repeated pain, simple stimulating, traction pressure, dull pain, cavity pain, digestion related pain, suffering. related pain. 3. The existence of levels of pain in accordance with patient's general background, the department of hospital, pain area of the body and school age was supported. Age, sex, religion, marrital status, economic status, acute or chronic status was not supported. 4. The existence of higher pain levels of the body area was anus, chest, and lower pain levels of the body area was eye, ear, nose and throat. Based on the above results, it was found that sensitive subclasses of the Korean Pain Measurement tool was 7 subclass among all of 20 subclass. Thus it can be concluded that Korean Pain Mea-surement tool when partialy used and supplemented, can be an effective tool of pain measurement for the patient in Korea.

  • PDF

A Randomized Trial Comparing the Effect of Unani Formulation with Metronidazole in Bacterial Vaginosis

  • Nazia Usmoni;Mariyam Roqaiya;Mohd Aqil Quadri;Arshiya Sultana;Taseen Banu;Sumbul Alam
    • CELLMED
    • /
    • v.13 no.14
    • /
    • pp.18.1-18.13
    • /
    • 2023
  • Background and objectives: Bacterial vaginosis (BV) is recognized as the most prevalent type of vaginal infection, impacting approximately 19-24% of women in their reproductive years. The recurrence rate of BV is significant, negatively impacting the well-being of affected women. This study aimed to compare the therapeutic effects of a polyherbal Unani formulation and metronidazole in treating bacterial vaginosis. Methodology: In this prospective patient blinded standard controlled trial, a total of 40 individuals with a clinical diagnosis of bacterial vaginosis were randomly assigned to receive either an active control treatment (n = 20) or a test drug (n = 20). In the test drug combination of Acacia catechu, Azadirachta indica and Quercus infectoria in tablet (1g) form in the dose of 2 tablets orally twice daily with water was administered for 3 weeks. In the active control standard drug, metronidazole 400 mg tablet, orally twice daily was given for one week. The primary outcome measure was clinical cure; H. negative Amsel's criteria and a reduction in subjective symptoms, while the secondary outcome measure was an improvement in SF-36 quality of life (QOL). Results and conclusion: Both the experimental treatment and the metronidazole demonstrated a significant clinical cure for bacterial vaginosis as well as an increase in health-related quality of life. Based on these findings, it appears that the test medication is a potent Unani formulation for the treatment of bacterial vaginosis. A well conducted trial with a bigger sample size is required to corroborate these findings.

Various Factors Influencing Thoracic Duct Lymph Flow in the Dogs (임파유통에 영향을 주는 인자에 관한 실험적 연구)

  • Kim, Ki-Whan;Earm, Yung-E
    • The Korean Journal of Physiology
    • /
    • v.9 no.1
    • /
    • pp.45-56
    • /
    • 1975
  • Various factors influencing the lymph flow from thoracic duct were investigated in an attempt to evaluate their contributing degree and the mechanisms. Sixteen mongrel dogs weighing between 10 and 16 kg were anesthetized and polyethylene catheters were inserted into the thoracic duct and femoral veins. Arterial blood pressure, heart rate, central venous pressure, lymph pressure and lymph flow were measured under various conditions. Electrical stimulation of left sciatic nerve, stepwise increase of central venous pressure, manual application of rhythmical depressions onto abdomen, injection of hypertonic saline solution and histamine infusion were employed. Measurement of cental venous pressure was performed through the recording catheter inserted into abdominal inferior vena cava. Changes in central venous pressure were made by an air-ballooning catheter located higher than the tip of the recording catheter in the inferior vena cava. Lymph flow from thoracic duct was measured directly with a graduated centrifuge tube allowing the lymph to flow freely outward through the inserted cannula. The average side pressure of thoracic lymph was $1.1\;cmH_2O$ and lymph flow was 0.40 ml/min or 1.9 ml/kg-hr. Hemodynamic parameters including lymph flow were measure immediately before and after (or during) applying a condition. Stimulation of left sciatic nerve with a square wave (5/sec, 2 msec, 10V) caused the lymph flow to increase 1.4 times. The pattern of lymph flow from thoracic duct was not continuous throughout the respiratory cycle, but was continuous only during Inspiration. Slow and deep respiration appeared to increase the lymph flow than a rapid and shallow respiration. Relationship between central venous pressure and the lymph flow revealed a relatively direct proportionality; Regression equation was Lymph Flow (ml/kg-hr)=0.09 CVP$(cmH_2O)$+0.55, r=0.67. Manual depressions onto the abdomen in accordance with the respiratory cycle caused the lymph flow to increase most remarkably, e.g,. 5.5 times. The application of manual depressions showed a fluctuation of central venous pressure superimposed on the respiratory fluctuation. Hypertonic saline solution (2% NaCl) administered Intravenously by the amount of 10 m1/kg increased the lymph flow 4.6 times. The injection also increased arterial blood pressure, especially systolic Pressure, and the central venous pressure. Slow intravenous infusion of histamine with a rate of 14-32 ${\mu}g/min$ resulted in a remarkable increase in the lymph flow (4.7 times), in spite of much decrease in the blood pressure and a slight decrease in the central venous pressure.

  • PDF

Down-regulation of SENP1 Expression Increases Apoptosis of Burkitt Lymphoma Cells

  • Huang, Bin-Bin;Gao, Qing-Mei;Liang, Wei;Xiu, Bing;Zhang, Wen-Jun;Liang, Ai-Bin
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.5
    • /
    • pp.2045-2049
    • /
    • 2012
  • Objective: To investigate the effect of down-regulation of Sentrin/SUMO-specific protease 1 (SENP1) expression on the apoptosis of human Burkitt lymphoma cells (Daudi cells) and potential mechanisms. Methods: Short hairpin RNA (shRNA) targeting SENP1 was designed and synthesized and then cloned into a lentiviral vector. A lentiviral packaging plasmid was used to transfect Daudi cells (sh-SENP1-Daudi group). Daudi cells without transfection (Daudi group) and Daudi cells transfected with blank plasmid (sh-NC-Daudi group) served as control groups. Flow cytometry was performed to screen GFP positive cells and semiquantitative PCR and Western blot assays were employed to detect the inference efficiency. The morphology of cells was observed under a microscope before and after transfection. Fluorescence quantitative PCR and Western blot assays were conducted to measure the mRNA and protein expression of apoptosis related molecules (caspase-3, 8 and 9). After treatment with $COCl_2$ for 24 h, the mRNA and protein expression of hypoxia inducible factor -$1{\alpha}$ (HIF-$1{\alpha}$) was determined. Results: Sequencing showed the expression vectors of shRNA targeting SENP1 to be successfully constructed. Following screening of GFP positive cells by FCM, semiqualitative PCR showed the interference efficiency was $79.2{\pm}0.026%$. At 48 h after transfection, the Daudi cells became shrunken, had irregular edges and presented apoptotic bodies. Western blot assay revealed increase in expression of caspase-3, 8 and 9 with prolongation of transfection (P<0.05). Following hypoxia treatment, mRNA expression of HIF-$1{\alpha}$ remained unchanged in three groups (P>0.05) but the protein expression of HIF-$1{\alpha}$ markedly increased (P<0.05). However, in the sh-SENP1-Daudi group, the protein expression of HIF-$1{\alpha}$ remained unchanged Conclusion: SENP1-shRNA can efficiently inhibit SENP1 expression in Daudi cells. SENP1 inhibition may promote cell apoptosis. These findings suggest that SENP1 may serve as an important target in the gene therapy of Burkitts lymphoma.

Copper Isotope Measurements Using a Neptune MC-ICP-MS (다검출기 유도결합 플라즈마 질량분석기를 이용한 구리 동위원소 분석법)

  • Park, Sanghee;Ryu, Jong-Sik;Shin, Hyung Seon;Kil, Youngwoo;Jo, Yunsoo
    • Journal of the Mineralogical Society of Korea
    • /
    • v.29 no.4
    • /
    • pp.221-227
    • /
    • 2016
  • Copper is an essential transition metal involving in various biogeochemical processes. With the recent advances in analytical techniques and mass spectrometry, such as MC-ICP-MS, it is possible to measure Cu isotopes, which allows us to understand various biogeochemical processes in detail. Nonetheless, few studies have been performed in South Korea. In this study, we compared two purification methods previously reported using an anion exchange resin ($AG^{(R)}$ MP-1M), developed the best method in our lab environment, and then verified it by measuring Cu isotopic compositions in two USGS geological reference materials (BHVO-2 and BIR-1a). Although all matrix cations causing mass bias were effectively removed through both two methods with the yield of better than 95%, the method using the mixture of HCl and $H_2O_2$ only displays Cu isotopic compositions, in excellent agreement with reported values within the error. The method developed in this study is expected to be commonly applied to earth and environmental sciences.

A low-noise transceiver design for 10GHz band motion sensor (인체감지 센서용 저 잡음 10GHz대역 송수신기 설계)

  • Chae, Gyoo-Soo
    • Journal of Digital Convergence
    • /
    • v.10 no.10
    • /
    • pp.313-318
    • /
    • 2012
  • In this study, we propose a low-noise transceiver for 10GHz motion sensor. The transceiver presented here has a circuit(Hittite HMC908LC5) that is composed of a two way-$0^{\circ}$ power splitter(the 1:2 block) and a $90^{\circ}$ Hybrid. The noise reduction circuit utilizes an LNA followed by an image reject mixer which is driven by an LO buffer amplifier. A modeling and analysis have been pursued using CST MWS. A prototype sensor was manufactured to measure the performance and experimental results show that the proposed sensor is good enough to use for a accurate motion sensor.

A Study on the Evaluations of Compression Force for the Prevention of Low Back Pain : Nine-step Stretching Exercises (요통 예방을 위한 요추부하 평가에 관한 연구)

  • Yang, S.H.;Kim, D.S.;Park, P.;Kal, W.M.;Kang, Y.S.
    • Journal of the Korean Society of Safety
    • /
    • v.13 no.4
    • /
    • pp.248-255
    • /
    • 1998
  • The objective of this study is to conduct the prevention method using electromyography that is to resist the strain on L5/S1 disc and to measure the heart rate for the prevention of low back pain during lifting. EMG signals and heart rate were analyzed under the condition of fixed vertical factor (20∼80cm), two horizontal factors (35cm, 55cm), and two weight factors (10kg, 25kg) 2 times per minute for each lifting task. Eight healthy male workers performed nine-step stretching exercises which were intensified back power at the L5/S1 disc for six months. After completion of the two trials, the results were compared. The results of this analysis show that EMG signals have more an effect on the weight than the horizontal factors similar to those analyzed previous study, and are decreased. Therefore, those exercises presented very efficient. Also, there are not statistically significant differences on the analysis result of heart rate between weight factors.

  • PDF

A STUDY ON THE CYTOTOXICITY OF THE ROOT CANAL SEALERS (근관충전용(根管充塡用) sealer의 세포독성(細胞毒性)에 관한 연구(硏究))

  • Lee, Seung-Jong;Kim, Yung-Hai
    • Restorative Dentistry and Endodontics
    • /
    • v.16 no.1
    • /
    • pp.25-40
    • /
    • 1991
  • Four root canal sealers, Apatite Root Sealer I and II composed mainly of hydroxyapatite/tricalciumphosphate, Sealapex containing calcium hydroxide, and Roth Sealer composed of zinc oxide - eugenol were compared on the culture of L929 fibroblasts. MIT (Methyl Thiazole Tetrazolium Bromide) colorimetric technique was used to measure the mitochondrial dehydrogenase activity. Results were as follows: 1. Hydroxyapatite/tricalcium phosphate mixed sealers were significantly less toxic compared with calcium hydroxide and zinc oxide - eugenol type sealers. High pH of the calcium hydroxide sealer and release of eugenol component from the zinc oxide - eugenol type sealer were presumed to be the cause of the toxicity of these two sealers. In no cases, there were more cytoblastic effects in hydroxyapatite/tricalcium phosphate mixed sealers compared to the control groups. 2. In all experimental groups, toxicity was decreased as dilutions were increased. However in zinc oxide-eugenol type sealer the cell activity was weakened for all dilution groups. 3. Regarding the effect of setting time, Apatite I and Sealapex were less toxic as the setting progressed. Apatite II kept constant regardless of the different time ellapsed after setting but Roth sealer revealed significantly higher toxicity for all experimental groups. 4. Comparing two different culture periods of 24 hours and 72 hours, Apatite I showed higher cell activities in longer period(72 hours) while Apatite II did not. Sealapex and Roth sealer, however, showed significantly lower cell activities in longer period.

  • PDF