Lightning impulse characteristics of large-scale ground rods with different length (대형 봉상 접지전극의 길이에 따른 뇌 임펄스 특성)

  • Lee, B.H.;Chang, K.C.;Eom, J.H.;Kim, B.K.;Jeong, D.C.;Kil, H.J.
    • Proceedings of the KIEE Conference
    • /
    • 2003.10a
    • /
    • pp.233-235
    • /
    • 2003
  • To obtain a low ground resistance in high resistivity soil or in insufficient place such as downtown, long vertical ground rods are often used. However, if the lightning current or fault current with high frequency flows into the grounding system, the ground impedance is significantly increased. This paper presents how the impulse current works on the long vertical ground rods with a different length. As a result, it can be estimated what the waveform is composed of and how the GPR is affected by the rate of current change.

  • PDF

Development of syngas supplying system for BTL (Biomass to Liquid) process (BTL(Biomass to Liquid) 공정을 위한 합성가스 공급 시스템 개발)

  • Kim, Y.D.;Kim, B.J.;Moon, J.H.;Lee, U.D.;Kim, K.S.;Yang, C.W.;Lee, J.W.;Lee, S.H.;Kim, J.H.;Lee, S.B.
    • 한국연소학회:학술대회논문집
    • /
    • 2012.04a
    • /
    • pp.223-226
    • /
    • 2012
  • Biomass to Liquid (BTL) is an attractive option for using biomass as an renewable energy. A syngas supplying system has been designed for BTL system, based on the Fischer-Tropsche (FT) process, and long-term operation test was conducted. The syngas supplying system is composed of a fluidized bed gasifier, gas cleaning and compression system, and methanol absorption system. Stable operation of more than hundred hours was achieved with several champaigns. In addition, a pilot scale biomass gasifier has been developed for 1 bbl/day BTL system and its performance was evaluated. Some preliminary results and current status of the development of BTL system will be presented.

  • PDF

A Study on the Effective Enhancement of the Load Power Factor Using the Load Power Factor Sensitivity of Generation Cost (발전비용의 부하역률 감도를 이용한 효율적인 역률 개선 연구)

  • Lee, B.H.;Oh, M.H.;Kim, J.H.;Shim, K.B.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.196-198
    • /
    • 2003
  • The low load power factor causes various problems such as the increase of the power loss and the voltage instability. The demand of reactive power increases continuously with the growth of active power and the restructuring of electric power companies makes the integrated management of ractive power troublesome, from which the systematic control of load power factor is required. In this paper, the load power factor sensitivity of the generation cost is derived and its effects in supplying the reactive power and enhancing the load power factor are analyzed in a small-scale power system. The load power factor sensitivity of the generation cost is applied for determining the locations and capacities of reactive power compensation devices. It is shown that the generation cost can be reduced and the system power factor can be enhanced effectively using the load power factor sensitivity.

  • PDF

A Study on the Effective Enhancement of the Load Power Factor Using the Load Power Factor Sensitivity of Generation Cost and Integrated Costs (발전비용의 부하역률 감도와 종합비용을 활용한 효과적인 역률개선 방안 연구)

  • Lee, B.H.;Oh, M.H.;Kim, J.H.;Shim, K.B.
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.284-286
    • /
    • 2003
  • The low load power factor causes various problems such as the Increase of the power loss and the voltage instability. The demand of reactive power increases continuously with the growth of active power and the restructuring of electric power companies makes the integrated management of ractive power troublesome, from which the systematic control of load power factor is required. In this paper, the load power factor sensitivity of the generation cost and integrated costs are used for determining the locations and capacities of reactive power compensation devices effectively and for enhancing the load power factor appropriately. It is shown through the application to a small-scale power system that the system power factor can be enhanced effectively and appropriately using the load power factor sensitivity and integrated costs.

  • PDF

A study on the health status of physical therapy college mans (물리치료과 학생의 건강 상태에 대한 연구)

  • YOUN Hee-Jong;LEE In-Hak
    • The Journal of Korean Physical Therapy
    • /
    • v.3 no.1
    • /
    • pp.59-73
    • /
    • 1991
  • The purpose of this study was to phychosomatic health status of physical therapy college mans. 130college mans analysis sex, habitation, religion, blood type, drinking, somoking by the todai health index questionaire. THI was modified front cornell medical index. Physical therapy college man showed complain score (E) Nervousness. (J) Mental irritability. (H) Impulsiveness. (F) Aggressiveness. (G) Irregular life (I), (L) Multiple subjective symtom(I), Live scale(L), (K) Depression. (C) Digestive, (A), (B) Respiratory(A), Eye and Skin(B). (D) Mouth and Anus.

  • PDF

Numerical Study on Turbulent Flow Inside a Channel with an Extended Chamber (난류 경계층에 놓인 공동 내부유동에 관한 수치해석적 연구)

  • Lee, Young-Tae;Lim, Hee-Chang
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.10
    • /
    • pp.925-931
    • /
    • 2010
  • The paper describes a Large Eddy Simulation (LES) study of turbulent flow around a cavity. A series of three-dimensional cavities placed in a turbulent boundary layer are simulated at a Reynolds number of $1.0{\times}10^5$ by considering U and h, which represent the velocity at the top and the depth of the cavity, respectively. In order to obtain the appropriate solution for the filtered Navier-Stokes equation for incompressible flow, the computational mesh forms dense close to the wall of the cavity but relatively coarse away from the wall; this helps reduce computation cost and ensure rapid convergence. The Boussinesq hypothesis is employed in the subgrid-scale turbulence model. In order to determine the subgrid-scale turbulent viscosity, the Smagorinsky-Lilly SGS model is applied and the CFL number for time marching is set as 1.0. The results show the flow variations inside cavities of different sizes and shapes.

Oxidation Behavior of Oxide Particle Spray-deposited Mo-Si-B Alloys

  • Park, J.S.;Kim, J.M.;Kim, H.Y.;Perepezko, J.H.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.20 no.6
    • /
    • pp.299-305
    • /
    • 2007
  • The effect of spray deposition of oxide particles on oxidation behaviors of as-cast Mo-14.2Si-9.6B (at%) alloys at $1200^{\circ}C$ up to for 100 hrs has been investigated. Various oxide powders are utilized to make coatings by spray deposition, including $SiO_2,\;TiO_2,\;ZrO_2,\;HfO_2$ and $La_2O_3$. It is demonstrated that the oxidation resistance of the cast Mo-Si-B alloy can be significantly improved by coating with those oxide particles. The growth of the oxide layer is reduced for the oxide particle coated Mo-Si-B alloy. Especially, for the alloy with $ZrO_2$ coating, the thickness of oxide layer becomes only one fifth of that of uncoated alloys when exposed to in air for 100 hrs. The reduction of oxide scale growth of the cast Mo-Si-B alloy due to oxide particle coatings are discussed in terms of the change of viscosity of glassy oxide phases that form during oxidation at high temperature.

TiO2 Nano-doping Effect on Flux Pinning and Critical Current Density in an MgB2 Superconductor

  • Kang, J.H.;Park, J.S.;Lee, Y.P.;Prokhorov, V.G.
    • Journal of Magnetics
    • /
    • v.16 no.1
    • /
    • pp.15-18
    • /
    • 2011
  • We have studied the $TiO_2$ doping effects on the flux pinning behavior of an $MgB_2$ superconductor synthesized by the in-situ solid-state reaction. From the field-cooled and zero-field-cooled temperature dependences of magnetization, the reversible-irreversible transition of $TiO_2$-doped $MgB_2$ was determined in the H-T diagram (the temperature dependence of upper critical magnetic field and irreversibility line). For comparison, the similar measurements are also obtained from SiC-doped $MgB_2$. The critical current density was estimated from the width of hysteresis loops in the framework of Bean's model at different temperatures. The obtained results manifest that nano-scale $TiO_2$ inclusions served as effective pinning centers and lead to the enhanced upper critical field and critical current density. It was concluded that the grain boundary pinning mechanism was realized in a $TiO_2$-doped $MgB_2$ superconductor.

Storm-Time Behaviour of Meso-Scale Field-Aligned Currents: Case Study with Three Geomagnetic Storm Events

  • Awuor, Adero Ochieng;Baki, Paul;Olwendo, Joseph;Kotze, Pieter
    • Journal of Astronomy and Space Sciences
    • /
    • v.36 no.3
    • /
    • pp.133-147
    • /
    • 2019
  • Challenging Minisatellite Payload (CHAMP) satellite magnetic data are used to investigate the latitudinal variation of the storm-time meso-scale field-aligned currents by defining a new metric called the FAC range. Three major geomagnetic storm events are considered. Alongside SymH, the possible contributions from solar wind dynamic pressure and interplanetary magnetic field (IMF) $B_Z$ are also investigated. The results show that the new metric predicts the latitudinal variation of FACs better than previous studies. As expected, the equatorward expansion and poleward retreat are observed during the storm main phase and recovery phase respectively. The equatorward shift is prominent on the northern duskside, at ${\sim}58^{\circ}$ coinciding with the minimum SymH and dayside at ${\sim}59^{\circ}$ compared to dawnside and nightside respectively. The latitudinal shift of FAC range is better correlated to IMF $B_Z$ in northern hemisphere dusk-dawn magnetic local time (MLT) sectors than in southern hemisphere. The FAC range latitudinal shifts responds better to dynamic pressure in the duskside northern hemisphere and dawnside southern hemisphere than in southern hemisphere dusk sector and northern hemisphere dawn sector respectively. FAC range exhibits a good correlation with dynamic pressure in the dayside (nightside) southern (northern) hemispheres depicting possible electrodynamic similarity at day-night MLT sectors in the opposite hemispheres.

Evaluation of Nitrogen and Phosphorus Balance in Green Manure-Rice Cropping Systems without Incorporation of Green Manure Crops (녹비작물 무 환원-벼 작부체계에서 질소와 인산수지 평가)

  • Kim, TaeYoung;Daquiado, Aileen Rose;Alam, Faridul;Lee, YongBok
    • Korean Journal of Environmental Agriculture
    • /
    • v.31 no.4
    • /
    • pp.308-312
    • /
    • 2012
  • BACKGROUND: The nutrient balance in Korea during 1985-2006 had continually increased and maintained the highest levels among OECD countries. The use of green manure crops such as barley and hairy vetch is common practice for reducing chemical fertilizer application and maintaining soil fertility. However, green manure crops can also be used as a livestock feeding material which may reduce nutrient balance in the national scale. We calculated nitrogen and phosphate balance under green manure-rice cultivating system where all green manure was removed and used for feeding livestock. METHODS AND RESULTS: The barley and hairy vetch grown in pure stands or in mixtures with different sowing rates were tested for rice cultivation without chemical fertilization. The conventional fertilization (NPK) for rice cultivation was selected to compare nutrient balance with green manure-rice cultivation. Nitrogen and phosphate balance were calculated according to the surface balance method of the PARCOM guidelines. Total aboveground biomass of mixture (barley and hairy vetch) was higher compared to that of pure barley or hairy vetch. Among the mixture with barley and hairy vetch, the highest aboveground biomass was observed in B75H25 (barley 75%+hairy vetch 25%). The nitrogen and phosphate balance in the B75H25 mixture was-104 kg N/ha and-50.3 kg P/ha, respectively. CONCLUSION(S): The barley and hairy vetch mixture proved to be a very effective strategy for biomass production of green manure. The amount of nitrogen and phosphate fertilizer to be applied is estimated to be 104 kg N/ha and 50.3 kg P/ha in order to maintain soil fertility if all green manure and rice straw were removed from rice field for livestock feeding.