• Title/Summary/Keyword: Guided mode

Search Result 261, Processing Time 0.039 seconds

The Theoretical Investigation of Phased Array Guided Waves (위상배열 유도초음파 검사의 이론적 고찰)

  • Lee, Jae-Sun;Cho, Youn-Ho;Achenbach, Jan D.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.31 no.4
    • /
    • pp.367-373
    • /
    • 2011
  • Guided waves inspection techniques that are different with inspection technique by bulk waves are widely used in pipe line evaluation due to advantages of long distance inspection. However, most of pipe lines at industrial fields are buried and/or coated. In this case, due to the attenuation effect from soil and/or coating material, there are a lot of difficulty on inspection by conventional ultrasonic technique. In this paper, guided waves propagating patterns are calculated with respect to excitation mode by Normal Mode Expansion(NME). Guided waves patterns based on excited by single transducer and guided wave focusing technique have employed to analyze focusing pattern on a pipe. A longitudinal mode and high order flexural modes are used with various number of transducers to determine sensitivity. Guided waves energy excited by multi transducer with focusing algorithm was successfully focused at a desired point.

Non-Contact Guided Wave Technique with Enhanced Mode-Selectivity (모드 선택성을 강화한 비접촉식 유도초음파 기술)

  • Kim, Hyun-Mook;Lee, Tae-Hun;Jhang, Kyung-Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.6
    • /
    • pp.597-602
    • /
    • 2004
  • In practical applications of guided wave techniques, it is very important but also difficult to identify the propagating modes, and it is preferred to generate and detect a single or less dispersive mode. Also the noncontact method is required in the automated field application. So this paper considers a non-contact guided wave technique with enhanced mode-selectivity, where a laser beam illuminated through arrayed line slits is used as the transmitter and the air-coupled transducer is used as the receiver. The line arrayed laser illumination is a wavelength matching technique that ran generate only a few modes. The air-coupled transducer detects the leaky wave of the propagated guided wave, and by tuning its detection angle we ran detect the selected single mode. Experimental results for a 1mm thick aluminum plate proved the usefulness of the proposed method, and especially it was shown that this method was powerful in the generation and detection of the $a_0$ mode.

Ultrasonic guided wave approach incorporating SAFE for detecting wire breakage in bridge cable

  • Zhang, Pengfei;Tang, Zhifeng;Duan, Yuanfeng;Yun, Chung Bang;Lv, Fuzai
    • Smart Structures and Systems
    • /
    • v.22 no.4
    • /
    • pp.481-493
    • /
    • 2018
  • Ultrasonic guided waves have attracted increasing attention for non-destructive testing (NDT) and structural health monitoring (SHM) of bridge cables. They offer advantages like single measurement, wide coverage of acoustical field, and long-range propagation capability. To design defect detection systems, it is essential to understand how guided waves propagate in cables and how to select the optimal excitation frequency and mode. However, certain cable characteristics such as multiple wires, anchorage, and polyethylene (PE) sheath increase the complexity in analyzing the guided wave propagation. In this study, guided wave modes for multi-wire bridge cables are identified by using a semi-analytical finite element (SAFE) technique to obtain relevant dispersion curves. Numerical results indicated that the number of guided wave modes increases, the length of the flat region with a low frequency of L(0,1) mode becomes shorter, and the cutoff frequency for high order longitudinal wave modes becomes lower, as the number of steel wires in a cable increases. These findings were used in design of transducers for defect detection and selection of the optimal wave mode and frequency for subsequent experiments. A magnetostrictive transducer system was used to excite and detect the guided waves. The applicability of the proposed approach for detecting and locating wire breakages was demonstrated for a cable with 37 wires. The present ultrasonic guided wave method has been found to be very responsive to the number of brokenwires and is thus capable of detecting defects with varying sizes.

A Study for Increasing the Safety of Gun Firing System of Patrol Killer Guided Missile from Failure Mode Analysis (고장 사례분석을 통한 유도탄고속함 함포체계 사격안전성 개선방안 연구)

  • Na, Ra-Byeol;Kim, Byeong-Ho;Seo, Jae-Hyun
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.20 no.2
    • /
    • pp.159-169
    • /
    • 2017
  • This study aims to the increasing the reliability of gun firing system of patrol killer guided missile from failure mode analysis. In order to find out the breakdown parameter, the examination process of the sources of the problems and the quality improvement activities are analyzed with performance testing data. From this study, the rate of operation and the reliability of 76 mm naval guns will be increase. And the result of the study is expected to be used as a reference data in the naval gun firing system for another failure mode analysis.

Experimental Evidence and Analysis of a Mode Conversion of Guided Wave Using Magnetostrictive Strip Transducer (자기변형 스트립 탐촉자에 의한 유도초음파 모드 변환에 대한 실험적 검증 및 해석)

  • Cheong, Yong-Moo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.2
    • /
    • pp.93-97
    • /
    • 2009
  • An advantage of a magnetostrictive strip transducer for a long-range guided wave inspection is that the wave patterns are relatively clear and simple when compared to a conventional piezoelectric ultrasonic transducer. Therefore, if we can characterize the evolution of defect signals, it could be a promising tool for a structural health monitoring of pipes for a long period of time as well as an identification of flaws. However, when evaluating a signal during a realistic field examination, it should be careful because of some spurious signals or false indications, such as signals due to a directionality, multiple reflections, mode conversion, geometrical reflections etc. Mode converted signals from a realistic piping mockup were acquired and analysed. We found mode conversions between a torsional guided wave T(0,1) mode and a flexural F(1,3) or longitudinal L(0,2) mode generated by a magnetostrictive strip transducer. Based on the experimental observations, an interpretation of the source of the mode conversion is discussed in a viewpoint of electromagnetic properties and structure of the strip transducer.

Development of an Array of EMAT for a Long-Range Inspection of a Pipe Using a Torsional Guided Wave

  • Cheong, Yong-Moo;Jung, Hyun-Kyu
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.3
    • /
    • pp.239-245
    • /
    • 2007
  • A torsional guided wave mode in a tubular structure has many advantages in obtaining a higher sensitivity and lower attenuation for a defect, because it shows no dispersion characteristics and no radial displacement for a tubular structure. Many attempts have been made to excite and receive torsional guided waves by conventional piezoelectric transducers, but only a few examples are used during a practical field inspection. In this study, an array of electromagnetic acoustic transducers (EMATs) were for an excitation and reception of the torsional guided waves in a pipe was designed and fabricated. The signal patterns were analyzed based on various beam path length. The feasibility of detecting the defects was investigated through a series of experiments with artificial notches on a pipe.

Lasing of Coupled Guided Modes in Modified Hollow Hexagonal Semiconductor Cavities

  • Moon, Hee-Jong;Lee, Jin-Woong;Hyun, Kyung-Sook;Jeong, Dae Cheol
    • Journal of the Optical Society of Korea
    • /
    • v.18 no.4
    • /
    • pp.377-381
    • /
    • 2014
  • Coupled guided modes, proposed in various modified hollow hexagonal cavities each attached internally to a hexagon, were demonstrated by investigating the laser oscillations in semiconductor cavities. The mode spacing between two adjacent lasing peaks decreased as the size of the internal hexagon increased, due to the increased round-trip length of the coupled guided modes. The linear dependency of the inverse mode spacing to the calculated round-trip length strongly confirmed the lasing of the coupled guided modes. The proposed modes in common-sized external cavities showed resonance structure that could be adjusted widely by controlling the size of the internal hexagon.

Sound Radiation Characteristics of Rectangular Plates with a Guided Edge Condition (모서리의 경계조건이 가이드 조건인 사각 평판의 음향방사 특성 연구)

  • Yoo, Ji-Woo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.9
    • /
    • pp.876-883
    • /
    • 2009
  • The radiation of sound from a rectangular plate with a guided edge condition is investigated. By taking this particular boundary condition into account, simple analytical forms of the average radiation efficiency and radiation power based on the modal approach can be found, where the cross-modal terms can average out for all possible point excitation locations. Design variables of the plate such as thickness, aspect ratio, and damping that are closely related to the sound radiation are mainly discussed. The radiation power of the guided plate is found to be governed by the piston mode as well as the critical frequency. While both the radiation efficiency and the radiation power seem to be influenced by thickness and a large aspect ratio, damping loss factor seems less important to the radiation power. It is also shown that no clear corner and edge mode regions may be found for the guided case, unlike the pinned.

A Study for Flaw Detection of 3/4″ Pipe by Using Guided Wave (유도초음파를 이용한 3/4″ 배관 결함 검출 연구)

  • Chung, Woo Geun;Kim, Jin-Hoi;Cheon, Keun Young
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.15 no.1
    • /
    • pp.40-45
    • /
    • 2019
  • Unlike the welded pipes in the primary system of light water nuclear power plants being periodically inspected with in-Service inspection program, relatively small pipes with the outer diameter less than 2 inch have not been regularly inspected to date. However, after several failure reports on the occurrence of critical crack-like defects in small pipes, inspection for the small pipes has been more demanded because it could cause the provisional outage of nuclear power plants. Nevertheless, there's no particular method to examine the small pipes having access limitations for inspection due to various reasons; inaccessible area, excessive radiation exposure, hazardous surrounding, and etc. This study is to develop a reliable inspection technique using torsional and flexural modes of guided wave to detect defects that could occur in inaccessible area. The attribute of guided wave that can travel a long distance enables to inspect even isolated range of the pipe from accessible location. This paper presents a case study of the evaluation test on 3/4" small-bore pipes with guide wave method. The test result demonstrates the crack signal behavior and assures possibility to detect the crack signal in a flexural mode, which is clearly distinguishable from the symmetric structure signal in a torsional mode.