• Title/Summary/Keyword: Guide surgery

Search Result 294, Processing Time 0.025 seconds

The utility of three-dimensional models in complex microsurgical reconstruction

  • Ogunleye, Adeyemi A.;Deptula, Peter L.;Inchauste, Suzie M.;Zelones, Justin T.;Walters, Shannon;Gifford, Kyle;LeCastillo, Chris;Napel, Sandy;Fleischmann, Dominik;Nguyen, Dung H.
    • Archives of Plastic Surgery
    • /
    • v.47 no.5
    • /
    • pp.428-434
    • /
    • 2020
  • Background Three-dimensional (3D) model printing improves visualization of anatomical structures in space compared to two-dimensional (2D) data and creates an exact model of the surgical site that can be used for reference during surgery. There is limited evidence on the effects of using 3D models in microsurgical reconstruction on improving clinical outcomes. Methods A retrospective review of patients undergoing reconstructive breast microsurgery procedures from 2017 to 2019 who received computed tomography angiography (CTA) scans only or with 3D models for preoperative surgical planning were performed. Preoperative decision-making to undergo a deep inferior epigastric perforator (DIEP) versus muscle-sparing transverse rectus abdominis myocutaneous (MS-TRAM) flap, as well as whether the decision changed during flap harvest and postoperative complications were tracked based on the preoperative imaging used. In addition, we describe three example cases showing direct application of 3D mold as an accurate model to guide intraoperative dissection in complex microsurgical reconstruction. Results Fifty-eight abdominal-based breast free-flaps performed using conventional CTA were compared with a matched cohort of 58 breast free-flaps performed with 3D model print. There was no flap loss in either group. There was a significant reduction in flap harvest time with use of 3D model (CTA vs. 3D, 117.7±14.2 minutes vs. 109.8±11.6 minutes; P=0.001). In addition, there was no change in preoperative decision on type of flap harvested in all cases in 3D print group (0%), compared with 24.1% change in conventional CTA group. Conclusions Use of 3D print model improves accuracy of preoperative planning and reduces flap harvest time with similar postoperative complications in complex microsurgical reconstruction.

Full-mouth rehabilitation using digital method to transfer provisional restoration to final fixed implant restoration (디지털 방법을 활용하여 임시수복물을 최종 고정성 임플란트 수복물로 이행한 완전 구강 회복 증례)

  • Cho, Eunhan;Lee, Younghoo;Hong, Seoung-Jin;Paek, Janghyun;Pae, Ahran;Kim, Hyeong-Seob;Kwon, Kung-Rock;Noh, Kwantae
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.4
    • /
    • pp.362-373
    • /
    • 2022
  • For a full-mouth fixed prosthetic treatment of the edentulous patient, it is essential to confirm the proper tooth position and thorough evaluation of the remaining alveolar bone and soft tissue before surgery. CAD-CAM dentistry and guided implant surgery have such advantages of providing simultaneous planning of surgery and prosthetic treatment to ensure pre-knowledge of the treatment. In this clinical case, using the digital technology, digital temporary denture fabrication, esthetic evaluation before fixed prostheses treatment, and guided surgery planning was possible. After the surgery, previously obtained data was used for fabricating fixed temporary prostheses. Definitive zirconia prostheses transferred from the provisional prostheses were fabricated and functionally and esthetically satisfying results were obtained.

Smart Glasses Cannula Guide System Development for Interventional Cardiology Procedures (중재적 심장 질환 시술을 위한 스마트 글래스 삽입관 가이드 시스템 개발)

  • Jang, Ik Gyu;Heo, Yeong Jun;Jeon, Geum Sang;Choi, Jaesoon
    • Journal of Biomedical Engineering Research
    • /
    • v.41 no.5
    • /
    • pp.173-178
    • /
    • 2020
  • Remote control intervention surgery robotic system improves treatment effect on cardiovascular patients and reduces X-ray exposure. However, at the time of the first procedure, CT (computerized tomography) and other ultrasound diagnostic equipment should be used because the operator must insert the cannula directly into the patient's leg. Improvements to this have been un-met-needs of hospitals. In this paper, we developed a system that can insert the cannula intuitively and quickly by displaying blood vessels at a glance through the system using smart wearable glasses. The core development method is as follows. In order to project augmented reality onto the surgical image, CT scan angiography image is extracted and processed. In the process, three CT-Markers are used to create a coordinate system of blood vessel images. Additionally, a reference marker is photographed on a single camera to obtain a camera coordinate system. Since the CT marker and the reference marker are in the same position, 3D registration is performed. In the text, a detailed explanation will be given.

Impact of the spatial orientation of the patient's head, metal artifact reduction, and tube current on cone-beam computed tomography artifact expression adjacent to a dental implant: A laboratory study using a simulated surgical guide

  • Matheus Barros-Costa;Julia Ramos Barros-Candido;Matheus Sampaio-Oliveira;Deborah Queiroz Freitas;Alexander Tadeu Sverzut;Matheus L Oliveira
    • Imaging Science in Dentistry
    • /
    • v.54 no.2
    • /
    • pp.191-199
    • /
    • 2024
  • Purpose: The aim of this study was to evaluate image artifacts in the vicinity of dental implants in cone-beam computed tomography (CBCT) scans obtained with different spatial orientations, tube current levels, and metal artifact reduction algorithm (MAR) conditions. Materials and Methods: One dental implant and 2 tubes filled with a radiopaque solution were placed in the posterior region of a mandible using a surgical guide to ensure parallel alignment. CBCT scans were acquired with the mandible in 2 spatial orientations in relation to the X-ray projection plane (standard and modified) at 3 tube current levels: 5, 8, and 11 mA. CBCT scans were repeated without the implant and were reconstructed with and without MAR. The mean voxel and noise values of each tube were obtained and compared using multi-way analysis of variance and the Tukey test(α=0.05). Results: Mean voxel values were significantly higher and noise values were significantly lower in the modified orientation than in the standard orientation (P<0.05). MAR activation and tube current levels did not show significant differences in most cases of the modified spatial orientation and in the absence of the dental implant (P>0.05). Conclusion: Modifying the spatial orientation of the head increased brightness and reduced spatial orientation noise in adjacent regions of a dental implant, with no influence from the tube current level and MAR.

Transcatheter Arterial Chemoembolization Combined with Interferon-α is Safe and Effective for Patients with Hepatocellular Carcinoma after Curative Resection

  • Zuo, Chaohui;Xia, Man;Liu, Jingshi;Qiu, Xiaoxin;Lei, Xiong;Xu, Ruocai;Liu, Hanchun;Li, Jianliang;Li, Yongguo;Li, Qinglong;Xiao, Hua;Hong, Yuan;Wang, Xiaohong;Zhu, Haizhen;Wu, Qunfeng;Burns, Michael;Liu, Chen
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.1
    • /
    • pp.245-251
    • /
    • 2015
  • Objectives: Intrahepatic recurrence is the major cause of death among patients with hepatitis B virus (HBV)-related hepatocellular carcinoma (HCC) after curative surgical resection. Several approaches have been reported to decrease the recurrence rate. The objective of our study was to compare the clinical effects of transcatheter arterial chemoembolization (TACE) combined with interferon-alpha (IFN-${\alpha}$) therapy on recurrence after hepatic resection in patients with HBV-related HCC with that of TACE chemotherapy alone. Methods: We retrospectively analyzed the data from 228 patients who were diagnosed with HBV-related HCC and underwent curative resection between January 2001 to December 2008. The patients were divided into TACE (n = 126) and TACE-IFN-${\alpha}$ (n = 102) groups for postoperative chemotherapy. The TACE regimen consisted of 5-fluorouracil (5-FU), cisplatin (DDP), and the emulsion mixed with mitomycin C (MMC) and lipiodol. The recurrence rates, disease-free survival (DFS), overall survival (OS), and risk of recurrence were evaluated. Results: The clinicopathological parameters and adverse effects were similar between the 2 groups (P > 0.05). The median OS for the TACE-IFN-${\alpha}$ group (36.3 months) was significantly longer than that of the TACE group (24.5 months, P < 0.05). The 3-and 5-year OS for the TACE-IFN-${\alpha}$ group were significantly longer than those of the TACE group (P < 0.05) and the recurrence rate was significantly lower (P < 0.05). The TACE and IFN-${\alpha}$ combination therapy, active hepatitis HBV infection, the number of tumor nodules, microvascular invasion, liver cirrhosis, and the BCLC stage were independent predictors of OS and DFS. Conclusions: The use of the TACE and IFN-${\alpha}$ combination chemotherapy after curative hepatic resection safely and effectively improves OS and decreases recurrence in patients with HBV-related HCC who are at high risk. Our findings can serve as a guide for the selection of postoperative adjuvant chemotherapy for patients with HBV-related HCC who are at high risk of recurrence.

The accuracy evaluation of digital surgical stents according to supported type (디지털 수술용 가이드의 지지타입에 따른 정확도 평가)

  • Lee, Junyoun;Yoon, Minho;Park, Taeseok;Chun, Inkon;Yun, Kwidug
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.1
    • /
    • pp.8-16
    • /
    • 2018
  • Purpose: The purpose of this study is to evaluate the accuracy of surgical stent according to the supported type. Materials and methods: 5 sets of dental models which have tooth supported edentulous area and tooth-tissue supported edentulous area were made. Dental model were scanned with model scanner, and CBCT was taken. CT data and model scan data were overlapped using In2Guide software, implant were virtually planned in the software. Surgical stents are fabricated by 3D printing. The implant fixture were installed using the surgical stent, CBCT were retaken. CBCT before surgery and after surgery were overlapped, and the differences (angle difference, coronal difference, apical difference) were evaluated using statistical analysis. Results: In the assessment of the accuracy of surgical guides according to arch type, there are no statistically significant differences between maxilla and mandible. In the case of support type, tooth supported stents showed lower angle difference and length difference than tooth-tissue supported stents, which are statistically significant. Conclusion: Arch type does not affect the accuracy of surgical stents. But tooth support stents are more accurate than tooth-tissue support stents in the case of angle and length difference.

Digital technique in diagnosis and restoration of maxillary anterior implant: a case report (디지털 기법을 활용한 상악 전치부의 진단 및 수복 증례)

  • Haemin, Bang;Woohyung, Jang;Chan, Park;Kwi-Dug, Yun;Hyun-Pil, Lim;Sangwon, Park
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.38 no.4
    • /
    • pp.249-256
    • /
    • 2022
  • The implant prosthesis of anterior maxilla requires careful consideration in planning. In order to satisfy both esthetic and functional needs of a patient, fusion of intra-oral scan in Cone-beam computed tomography (CBCT) and facial scan can be considered. Bony structures and soft tissues captured in CBCT and occlusal surfaces of intra oral scan were incorporated into personal characteristics from facial scan. The patient had insufficient buccal bone on maxillary anterior area. The maxillary implants could not be placed on the most ideal position. However, the "top down" approach completed by computer-generated arranging of teeth in implant planning and surgery with surgical guide resulted in esthetically and functionally satisfying result regardless of the limitation. Careful diagnosis with digital technique and the usage of surgical guide resulted in successful surgery and esthetic restoration. The temporary fixed prostheses were designed, restored and evaluated. The patient was not satisfied with the first design of temporary prosthesis, which showed uneven space distribution between teeth due to the position of maxillary implant. The design was modified by changing proximal emergence contours and line angle to alter the perceived since of incisors. The patient was satisfied with the new design of provisional restoration. A digital occlusion analyzer (Arcus Digma II, KaVo, Leutkirch, Germany) was used to measure inherent condylar guidance and anterior guidance of a patient to provide a definitive prosthesis.

A Case of Congenital Midline Fistula of the Lower Lip (아랫입술에 생긴 선천성 샛길 증례)

  • Choi, Hwan-Jun;Choi, Yim-Don;Choi, Chang-Yong;Kim, Sook;Kim, Yong-Bae
    • Archives of Plastic Surgery
    • /
    • v.38 no.1
    • /
    • pp.73-76
    • /
    • 2011
  • Purpose: Congenital midline upper lip sinus is a rare lesion. There are two postulates that can account for the formation of the upper lip sinus based on two major theories of the development of the face: the fusion theory and the merging theory. However, congenital midline lower lip sinus is very rarely reported and described. We report a case of a congenital midline sinus of the lower lip in a 6-year-old female. Methods: A 6-year-old girl presented with a nipple like swelling on the midline lower lip. Physical examination revealed about $5{\times}5$ mm protruding round mass with a just small opening that was non-tender to palpation. The mass was not associated with any skin changes. It umbilicated at the apex and contains a fistulous tract, discharging clear fluid. Only, simple radiologic finding shows bony spur on the lower one third of mandibular symphsis. Results: A small transverse ellipse is made around the opening and elevated mass with sharpe dissection. The tract is excised using the probe and dye as the guide. The tract was extended to periosteum of the lower one third of the mandible. The tract and involved periosteum were excised en bloc, and removed protrusion of the mandibular bone using diamond burr. Microscopic examination of the resected sinus revealed the fistulous tract itself, consisting of fibrous connective tissue covered with cornified stratified squamous epithelium, was observed in the center of the sample. In 6 months follow-up, This patient had a good result was obtained by the method of fistulectomy alone. Conclusion: Midline cranoifacial fistulas represent rare lesions resulting from abnormal fusion of embryologic structures. Our case report describes the excision of a congenital midline sinus of the lower lip in a 6-year-old female. This case represents the first report of a lower lip sinus presenting in a girl as a mass in the skin of the chin with extension to the midline of the mandible. However, the etiology of this rare congenital sinus remains obscure.

A Clinical Database of Breast Cancer Patients Reveals Distinctive Clinico-pathological Characteristics: a Study From Central China

  • Wang, Lin-Wei;Yang, Gui-Fang;Chen, Jia-Mei;Yang, Fang;Yuan, Jing-Ping;Sun, Sheng-Rong;Chen, Chuang;Hu, Ming-Bai;Li, Yan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.4
    • /
    • pp.1621-1626
    • /
    • 2014
  • Background: Breast cancer is the most common malignant tumor in females worldwide. Many differences exist in clinico-pathological characteristics of breast cancer patients between China and Western countries. This study aimed to analyze clinico-pathological characteristics of breast cancer from central China. Methods: Clinico-pathological information on breast cancer from three hospitals in central China was collected and analyzed. Results: From 1994 to 2012, 2,525 patients with a median age 50 years were included in this study. The 45-49-year age group and invasive ductal carcinoma not otherwise specified accounted for the highest proportions (19.1%, 480/2,525 and 81.0%, 1,982/2,446). Stages 0-I, II and III accounted for 28.0% (682/2,441), 48.4% (1,180/2,441), and 23.7% (578/2,441), respectively. Distribution of N stage showed that N0 accounted for 53.2% (1,344/2,525), and proportion of N0 rose from 51.1% (157/307) in 30-39-year age group to 64.3% (110/171) in ${\geq}$ 70-year age group, with an average increase of 2.1% in each age group. Modified radical mastectomy, radical mastectomy, breast-conserving surgery and simple mastectomy were performed for 71.8% (1,812/2,525), 18.0% (454/2,525), 5.2% (131/2,525) and 2.6% (66/2,525), respectively. Proportions of breast-conserving surgery in age ${\leq}$ 44-year group (68/132, 51.5%) and simple mastectomy in age ${\geq}$ 60-year group (57/89, 64.0%) were higher than in the other age groups. Breast cancers positive for estrogen receptor accounted for 53.0% (1,107/ 2,112). The comparisons among this study and other reports showed higher proportion of younger patients, lower proportion of breast-conserving surgery and positive estrogen receptor patients in China than western countries. Conclusions: Clinico-pathological characteristics in this study demonstrated clear differences between the center of China than Western countries. Additional classification systems should be developed to guide grading of early breast cancer more accurately, especially for N0 patients. Invasive ductal carcinoma is a focus for intensive research.

PRIMARY STABILITY OF IMPLANTS IN ILIUM OF CADAVER BY THE METHODS OF RECIPIENT SITE PREPARATION (사체의 장골에서 수용부 형성방법에 따른 임플란트 일차 안정성)

  • Sim, Jung-Woo;Cho, Jin-Yong;Kook, Min-Suk;Park, Hong-Ju;Oh, Hee-Kyun
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.34 no.2
    • /
    • pp.180-186
    • /
    • 2008
  • Purpose: This study was performed to evaluate the effect of the implant recipient site preparation methods on primary stability of implants with the instruments of $Osstell^{TM}$ and $Periotest^{(R)}$ in the iliac bone of cadaver. Methods and materials: The 8 iliac bones in 4 cadavers and implants treated with resorbable blasting media (RBM) were used. $Periotest^{(R)}$ (Simens AG, Germany) and $Osstell^{TM}$ (Model 6 Resonance Frequency Analyser: Integration Diagnostics Ltd., Sweden) were used to measure primary stability of implants. Implants were inserted into the iliac crest of the cadaver. In control group, the recipient site was prepared according to the manufacturer's recommendation: 1.8 mm guide drill, 2.0 mm initial drill, 2.7 mm pilot drill, 2.7 mm twist drill, 3.0 mm twist drill, 3.3 mm pilot drill, 3.3 mm twist drill, and 3.3 mm countersink drill as well as tapping drill were used in order. In the group 1, implant recipient sites were prepared by sequentially drilling from 1.8 mm guide drill to 3.0 mm twist drill and then inserted implants without countersinking and tapping. In the group 2, implant recipient sites were prepared to 3.0 mm twist drill and countersink drill and then inserted implants without tapping. In the group 3, the sites were prepared to 3.0 mm twist drill and countersink drill as well as tapping drill. In the group 4, the sites were prepared to 3.3 mm twist drill. In the group 5, the sites were prepared to 3.3 mm twist drill and countersink drill. A total of 60 implants were placed (n=10). The stability was measured using $Osstell^{TM}$ and $Periotest^{(R)}$ mesiodistally and buccolingually. To compare the mean stability of each group statistically, One-way ANOVA was used and correlation of instrument were analyzed using SPSS 12.0. The results obtained were as follows; 1. The stability of group 1 measured using $Osstell^{TM}$ and $Periotest^{(R)}$ buccolingually showed the highest, and there are significant difference statistically between control group and experimental group 1,2,4 in each instruments respectively (p<0.05). 2. The stability of group 1 measured using $Osstell^{TM}$ and $Periotest^{(R)}$ mesiodistally showed the highest. There are significant difference statistically between control group and all experimental groups in $Osstell^{TM}$, and between control group and experimental group 1,2,3,4 (p<0.05). 3. There are high correlation between the measurements of $Osstell^{TM}$ and $Periotest^{(R)}$ (p<0.05). Conclusion: These results indicate that the primary stability of implant can be obtained by the recipient sites preparation with smaller diameter drill than that of implant or minimal drilling.