• Title/Summary/Keyword: Guide Block

Search Result 92, Processing Time 0.029 seconds

Development of Polymer Mortar Guide Block for the Blind Handicapped People (폴리머 복합재료를 이용한 유도 블럭의 개발)

  • 이기원;연규석;이윤수;지경용
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 1999.10c
    • /
    • pp.330-335
    • /
    • 1999
  • The objective of this stu요 was to develop a polymer mortar guide block for the blind handicapped people. A high strength and a long durability polymer concrete using unsaturated polyester resin was used to developed the block and to improve the exiting cement mortar guide bloc. Physical and mechanical properties of the polymer mortar guide block were investigated with respect to absorptivity, impact strength, bending strength compared to those of the conventional cement guide block. The polymer mortar guide block was proven to have properties , indication that the block have better industrial applications.

  • PDF

Simulation of Molecular Flows Inside a Guide Block in the OLED Deposition Process (OLED 박막 증착공정에서 유도로 내부의 분자유동 해석)

  • Sung, Jae-Yong;Lee, Eung-Ki
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.17 no.2
    • /
    • pp.45-50
    • /
    • 2008
  • Molecular flows inside a guide block in the OLED(organic luminescent emitting device) deposition process have been simulated using DSMC(direct simulation Monte Carlo) method. Because the organic materials are evaporated under vacuum, molecules flow at a high Knudsen number of the free molecular regime, where the continuum mechanics is not valid. A guide block is designed as a part of the linear cell source to transport the evaporated materials to a deposition chamber, When solving the flows, the inlet boundary condition is proved to affect significantly the whole flow pattern. Thus, it is proposed that the pressure should be specified at the inlet. From the analysis of the density distributions at the nozzle exit of the guide block, it is shown that the longer nozzle can emit molecules more straightly. Finally, a nondimensionalized mass flow profile is obtained by numerical experiments, where various nozzle widths and inlet pressures are tested.

Effect of 2nd Axis Linear Motion Guide on Mechanical Performance of Robot in 2-Axis Cartesian Coordinate Robot (2축 직교좌표 로봇에서 2축 직선 운동 가이드가 로봇의 기계적 성능에 미치는 영향)

  • Lee, Jong Shin
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.13 no.1
    • /
    • pp.95-103
    • /
    • 2011
  • Robots in various types carry and assemble parts through repeatedly and accurately moving to stored locations by combining linear motions. And, linear systems are used in orthogonal axes of robots and driven via ball screws, such as 2-axis cartesian coordinate robot in this paper. This paper presents the effect of the linear motion guide that is used in $2^{nd}$ axis in 2-axis cartesian coordinate robot. Some simulation results show that the linear motion guide influence greatly in robot performance such as the nominal life of linear guide. When use LM guide that have capacity near in $2^{nd}$ axis, this paper show that the nominal life on LM block of $1^{st}$ axis increases 37.4% and that the specification of $2^{nd}$ axis LM guide influences greatly the nominal life of $1^{st}$ axis LM block.

Determination of Walking Direction for Guidance of the Blind (시각장애인 보행 안내를 위한 진행 방향 판단 기법)

  • Ko, Byung-oh;Kim, Hakyung;Son, Jinwoo;Jung, Kyeong-Hoon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2019.05a
    • /
    • pp.49-52
    • /
    • 2019
  • Braille guide block of sidewalk is an essential facility for independent walking of the blind. The blind walks while checking the braile guide blocks with white cane and sense of sole. When they leave the braile area, they face difficulties until they find the braile guide blocks again. In this paper, we propose an algorithm that guides the walking of the blind by determining whether they follows the braille guide blocks safely. For this purpose, the slope of the braille block is selected as a feature and a 3-line detector is introduced. Also the slopes are stabilized using spatial filtering to deal with breaks or junctions of the braille block during the progress and temporal filtering to cope with ego-motion of the blind. Through simulations using a dataset obtained from the real sidewalks and indoors, it can be shown that the proposed algorithm can successfully estimate the walking direction and determine whether the blind is out of the braille guide block area.

  • PDF

Case Study on the Safety Working Load of a LM-Guide Structure (볼나사일체형 LM가이드 설계에 관한 연구)

  • Yoon, Young-Sik;Shin, Dong-Woo
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.820-825
    • /
    • 2007
  • A ballscrew-linear motion(LM) guide is well-described by its name: it is a LM guide that runs by ballscrew. It consists of LM rail, LM block, end plate, screw, nut and bearing balls. The ballscrew-LM guide has many advantages compared with conventional LM guide. The high efficiency achieved with rolling contact devices permits the employment of antibacklash methods. The balls provide the only physical contact between nut rail and block and ball screw and nut replacing the sliding friction with a rolling motion. The life of the ballscrew-LM is determinated by the balls. The objective of this paper is to introduce the design of the ballscrew-LM with the safety working load.

  • PDF

Imaging Study of Fine Pixel Scintillator Block using Reflector on the Side of Light Guide (광가이드 측면 반사체 사용을 통한 미세 픽셀 섬광체 블록의 영상화 연구)

  • Seung-Jae Lee;Byungdu Jo
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.5
    • /
    • pp.671-677
    • /
    • 2023
  • When a scintillator block is constructed using fine scintillator pixels, the scintillator block located at the edge of the scintillator block results in overlapping images. To solve this problem, a light guide was inserted between the scintillator block and the photosensor, and images of all scintillation pixels were separated and acquired. However, loss of light may occur through the light guide, which eventually affects the quality of the image due to a decrease in energy resolution. Therefore, in this study, a detector was designed that can separate scintilltion pixels better by using a reflector on the side of the light guide and can secre excellent energy resolution by minimizing light loss. For comparative evaluation with previous studies, flood images were obtained through DETECT2000 capable of light simulation, and the degree of separation and light collection rate were evaluated. When a reflector was used on the side of the light guide, all materials showed excellent separation regardless of the material of the light guide, which showed better separation results than previous studies. In addition, the light collection rate was more that five times better when the reflector was applied than when it wa not. If this detector is applied to a small animal positron emission tomography, it will be possilbe to secre excellent image quality through excellent spatial resolution and energy resolution.

Analysis of the Motion Accuracy in Linear Motion Bearing Guide (직선베어링 이송계의 운동정밀도 해석)

  • 김경호;이후상;박천홍;김승우
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.179-183
    • /
    • 2000
  • This paper is concerned with achieving the high motion accuracy of linear motion bearing guide according to estimate accuracy average effect of bearing. Accuracy average effect can be obtained b analysis the relationship between motion error of the table and spatial frequency of the rail form error. And influences of ball diameter, ball number, and clock length on block motion error and block number on the table motion error are analyzed theoretically. In addition to, a simple experiment is performed in order to verify theoretical result.

  • PDF

A Clinical Survey of Patients of Neuro-Pain Clinic (신경통증과 환자의 임상통계 고찰)

  • Shin, So-Hyun;Chung, Young-Pyo;Lim, Jae-Jin;Yoon, Kyung-Bong;Kim, Chan
    • The Korean Journal of Pain
    • /
    • v.7 no.1
    • /
    • pp.84-87
    • /
    • 1994
  • Retrospective analysis, of 1,734 patients treated for nerve block from October 1991 to March 1994. Largest percentage of patients were in the 50 year old range, with a distribution of 44.9% male and 55.1% female. Treatments were for ailments of: Low Back Pain 17.3%, Multiple Contusion 10.5%, and Cancer 10%. Most common nerve block was epidural block 38.6%, followed by stellate ganglion block 38.4%, intercostal block 5.4%, and suprascapular nerve block 5.2%. Nerve block under fluorscopic guide were as follows: facet joint block 34.1%, lumbar sympathetic ganglion block 13.6%, and celiac plexus block 12.9%.

  • PDF

A Study on the Effectiveness of a Guide Hole on Crack Growth Control in Blasting (발파에서 가이드공의 균열제어 유효성에 관한 실험적 연구)

  • Lee, Hee-Gwang;Kim, Seung-Kon;Cho, Sang-Ho
    • Tunnel and Underground Space
    • /
    • v.20 no.2
    • /
    • pp.125-130
    • /
    • 2010
  • Model blast experiments of mortar blocks were performed to investigate the effect of the guide hole on crack growth. The mortar block specimens have a blast charge hole and 8 guide holes. Two of circular guide hole, notched guide hole, diamond shaped guide hole and diamond shaped guide holder are installed around 110 mm, 165 mm and 220 mm apart from the charge hole for each specimen. From the blast experiments, it was revealed that all the guide hole used in this study were effective for controlling the crack growth at the fracture control.