• 제목/요약/키워드: Group velocity

검색결과 1,134건 처리시간 0.023초

갑상선기능항진증(甲狀線機能亢進症)에서 좌심실용적(左心室容積) 및 기능변화(機能變化)에 관한 연구(硏究) (Effects of Thyroid Hormone on Left Ventricular Volume and Function in Hyperthyroidism)

  • 이명철;고창순
    • 대한핵의학회지
    • /
    • 제17권2호
    • /
    • pp.1-17
    • /
    • 1983
  • The purpose of this study is to investigate the effects of thyroid hormone on the left ventricular(LV) volume arid function in man with untreated hyperthyroidism and to determine the effects of successful therapy for thyrotoxicosis on the ventricular pathophysiology. In the present study, equilibrium radionuclide cardiac angiography was performed and LV volume index, ejection phase indexes of LV performance, serum thyroid hormone levels and other hemodynamic parameters were measured in 28 normal subjects and 39 patients with hyperthyroidism before treatment and again every 4 weeks for the first 2 months after the initiation of effective therapy. The results obtained were as follows; 1) In the untreated hyperthyroid state heart rate, blood volume, cardiac index and stroke volume index($97{\pm}14$ beats/min, $73.5{\pm}11.8ml/kg,\;6.9{\pm}1.4\;l/min/m^2$ and $77.6{\pm}13.8ml/m^2$, respectively) were increased significantly compared to those in normal control($74{\pm}12beats/min$, $66.6{\pm}14.8ml/kg,\;3.8{\pm}1.2\;l/min/m^2$ and $56.6{\pm}13.2ml/m^2$ respectively). $(Mean{\pm}SD)$ 2) There was a significant increase in LV end-diastolic volume index in patients with hyperthyroidism ($30.5{\pm}7.5$ for hyperthyroid group compared to a normal control of $22.2{\pm}6.5$; p<0.001), whereas end-systolic volume index remained unchanged $9.6{\pm}3.6\;and\;8.8{\pm}3.3$ respectively).3) In patients with hyperthyroidism, LV ejection fraction was $70.0{\pm}5.6%$, fractional shortening $32.9{\pm}5.1%$, mean velocity of circumferential fiber shortening(mean Vcf) $1.34{\pm}0.31$ circ/sec and maximum ejection rate $3.47{\pm}0.80$. All the ejection phase indexes were significantly greater than those in normal control($65.2{\pm}5.7%,\;28.8{\pm}3.2%,\;0.88{\pm}0.37$ circ/see and $2.27{\pm}0.50$, respectively; p<0.001). 4) Effective therapy produced significant decrease in all the values of serum thyroid hormone concentrations(p<0.00l), hemodynamic parameters(p<0.001), end-diastolic volume index(p<0.01) and ejection phase indexes of LV contractility in patients with hyperthyroidism and after one to two months, when the patients were euthyroid, these measurements were in the range of normal. 5) A significant linear correlation between mean Vcf and serum thyroxine level(r=0.63, p<0.001) as well as between mean Vcf and serum triiodothyronine level(r=0.62, p<0.001) was found. The lesser degree of correlation was also noted between other ejection phase indexes and serum thyroid hormone concentrations. The results indicate that the major effects of excess thyroid hormone on the LV in human beings with hyperthyroidism are an enhancement of LV function and an increase in LV enddiastolic volume and that these effects cause predictable reversible cardiac alteration which are changed dramatically and immediately after effective therapy.

  • PDF

Ba2Mg0.5Co1.5(Fe0.99In0.01)12O22의 뫼스바우어 분광 연구 (Investigation of Mössbauer Spectra of Ba2Mg0.5Co1.5(Fe0.99In0.01)12O22)

  • 임정태;김진모;김철성
    • 한국자기학회지
    • /
    • 제22권1호
    • /
    • pp.19-22
    • /
    • 2012
  • $Ba_2Mg_{0.5}Co_{1.5}(Fe_{0.99}In_{0.01})_{12}O_{22}$ 시료는 직접합성법으로 제조하였으며, 결정학적 및 자기적 특성을 x-선 회절기(x-ray diffractometer), 진동시료 자화율측정기(vibrating sample magnetometer)과 뫼스바우어 분광기(M$\ddot{o}$ssbauer spectrometer)실험을 이용하여 연구하였다. $Ba_2Mg_{0.5}Co_{1.5}(Fe_{0.99}In_{0.01})_{12}O_{22}$ 시료는 rhombohedral 결정구조로 공간그룹은 R-3m으로 결정되었다. 295 K에서 자화율 값은 28.6 emu/g을 가지며 페리자성 특성을 나타내고 있다. 시료의 뫼스바우어 분광 측정결과 4.2 K부터 620 K까지 6-sextet이 존재하였다. 이성질체 이동치의 값은 전 온도구간에서 Fe 이온은 모두 $Fe^{3+}$로 존재함을 알 수 있었고, zero velocity count(ZVC) 곡선을 통해 630 K를 퀴리온도를 결정하였다.

빅 데이터 시대 위험기반의 정책 - 개인정보침해 사례를 중심으로 - (Risk based policy at big data era: Case study of privacy invasion)

  • 문혜정;조현석
    • 정보화정책
    • /
    • 제19권4호
    • /
    • pp.63-82
    • /
    • 2012
  • 우리나라의 정보인프라는 세계 최고 수준이다. 그러나 심각한 보안 사고의 위험 또한 동반하고 있다. 최근 일어난 주요 사고만 정리해도 유출된 개인정보는 우리나라 인터넷 사용인구의 세 배를 넘는다. 이제 개인정보 침해 등의 정보보안의 사고는 국가의 일급재난에 해당하는 정책문제가 되었다. 이 논문은 빅 데이터 시대의 정보보안을 위한 정책적 논의를 사회과학 차원에서 탐구하였다. 이를 위해 최근 사고가 급증한 개인정보침해 사례를 위험기반으로 분석하였다. 사례분석결과는 다음과 같다. 첫째, 발생가능성과 영향에 따라 정보통신기술의 위험의 상황은 '심각, 강력, 집중, 기본'으로 구분되었다. 둘째, 위험의 상황에 따라 해당집단은 '계층주의, 평등주의, 운명주의, 개인주의' 문화유형을 지니며 '회피, 전가, 완화, 수용'의 대응 정책을 적용하였다. 셋째, 위험상황에 따라 정보통신기술은 '대용량, 고성능, 다양성'의 빅 데이터의 특성을 보였다. 이 연구의 시사점은 다음과 같다. 첫째, 위험상황별 문화유형과 빅 데이터의 특성을 이해하여 포괄적인 정책을 수립하고 적용할 수 있는 정부의 전담조직이 필요하다. 둘째, 빅 데이터 시대 정보통신기술에 대한 위험관리는 '기술, 규범, 법, 시장' 측면의 균형 있는 정책의 적용이 필요하다.

  • PDF

주파수영역 음향 파동방정식에서 최소 격자수 결정을 위한 격자분산 분석 (A Dispersion Analysis for Minimum Grids in the Frequency Domain Acoustic Wave Equation)

  • 장성형;신창수;윤광진;서상용;신성렬
    • 지구물리와물리탐사
    • /
    • 제3권2호
    • /
    • pp.39-47
    • /
    • 2000
  • 복잡한 지층구조에 대한 파동방정식의 해를 유한 차분법을 이용하여 구하는것은 많은 컴퓨터 계산시간과 기억 용량이 필요하다. 컴퓨터 계산시간과 기억용량은 최소 파장당 격자수를 줄이므로써 감소 시킬 수 있지만 수치분산으로 인해 정확도가 떨어지게 마련이다. 본 연구에서는 정확도를 유지하면서 파장당 격자수를 줄이는 방법으로 이용되고 있는 가중평균법을 최대 169점 까지 확장하여 주파수 영역에서 음향파동방정식의 해를 유한차분법으로 구할 때 최소 격자수를 구하기 위한 격자분석을 실시하였다. 지금까지 수치오차가 정확도 $1\%$내에 존재하기 위해서는 일반적인 5점을 이용하는 경우 파장당 격자수가 13개 이상이 필요하고, 9점의 경우 9개, 25점에서는 3개, 49점에서는 2.7개 이상이 필요하였다. 본 연구에서 정확도를 유지하기 위한 최소격자수를 결정하기 위해 실시된 격자분석 결과 81점에서는 2.5개 121점에서는 2.3개 그리고 169점에서는 오차 한계를 벗어나 가중평균 계수를 구할 수 없었으며 격자수를 2개까지 줄일 수 없음을 알 수 있었다. 또한 격자분석을 통해 가중평균에 적용되는 격자수가 증가할수록 정확도는 증가하지만 차분식 자체가 증가하여 매우 복잡하게 된다.

  • PDF

3차원 불균질 횡등방성 매질에 대한 탄성파 초동 주시 모델링 (Seismic First Arrival Time Computation in 3D Inhomogeneous Tilted Transversely Isotropic Media)

  • 정창호;서정희
    • 지구물리와물리탐사
    • /
    • 제9권3호
    • /
    • pp.241-249
    • /
    • 2006
  • 한국의 지질 환경은 암석 분포가 매우 다양하고 복잡한 구조 활동의 영향을 받아 지하매질의 이방성 특성이 국부적으로 심하게 변화한다. 기존의 이방성 주시 모델링의 경우 지질 모델을 2차원으로 단순화시킴으로써 이러한 복잡한 지질 환경을 제대로 고려할 수 없었다. 또한 약 이방성 가정을 사용하여 실제로 나타날 수 있는 지하 매질의 심각한 이방성 영향을 주시 모델링에서 고려할 수 없었다. 이에 이 연구에서는 보다 실제적이고 복잡한 3차원 횡등방성 매질(transversely isotropic media)에서 q-P파의 초동 주시 양상을 모사할 수 있는 주시 모델링 알고리듬을 개발하였다. 이 알고리듬에서는 2차원 비선형 주시 내삽(2D nonlinear traveltime interpolation) 기법과 주시의 3차원 격자 채움법(mapping)을 이용한 직접 전파법(direct calculation)을 통해 급격한 물성의 변화에도 주시 계산이 가능하도록 하였다. 또한, 최소 주시 계산과정에서 수치 미분을 통한 최대 경사법(steepest descent method)을 사용하여 약 이방성 가정을 극복하였다. 개발된 알고리듬은 해석해와 비교하여 그 타당성을 검증하였고 3차원 2층구조에 대한 주시 계산을 수행하여 물성이 급격히 변화하는 모델에 대해서도 안정적으로 주시 계산이 이루어짐을 확인하였다. 이 연구에서 개발한 3차원 주시 모델링 알고리듬은 향후 구조보정이나 토모그래피 알고리듬 개발에 사용될 수 있을 것으로 기대한다.

$Al_2O_3$, CuO와 $MnO_2$가 첨가된 $Pb(Zr_xTi_{1-x})O_3-Pb(Zn_{1/3}Nb_{2/3})O_3-Pb(Ni_{1/3}Nb_{2/3})O_3$ 유전체의 저온 소결 및 압전 특성 (Low Temperature Sintering and Piezoelectric Properties of $Al_2O_3$, CuO and $MnO_2$ Added $Pb(Zr_xTi_{1-x})O_3-Pb(Zn_{1/3}Nb_{2/3})O_3-Pb(Ni_{1/3}Nb_{2/3})O_3$ Ceramics)

  • 안철우;박승호;샤샹크 프리야;켄지 우치노;송재성;남산
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.1
    • /
    • pp.138-141
    • /
    • 2004
  • [ $MnO_2$ ]가 첨가된 $0.9Pb(Zr_{0.5}Ti_{0.5})O_3-0.2Pb[(Zn_{0.8}Ni_{0.2})_{1/3}Nb_{2/3}]O_3$(0.8PZT-0.2PZNN) 세라믹스는 그 압전특성과 유전특성이 뛰어나지만 $1000^{\circ}C$ 이하의 낮은 소결 온도에서는 소결되지 않는다. $1000^{\circ}C$이하의 낮은 소결온도에서 소결하기 위해 CuO를 첨가한 결과, 소결온도 $920^{\circ}C$에서 소결성은 우수하였으나 그 압전 특성의 저하가 두드러졌다. 이는 XRD에서 확인한 결과에 따르면 CuO의 첨가가 우수한 MPB 조성으로 판명된 $MnO_2$ 가 첨가된 0.8PZT-0.2PZNN 세라믹스의 결정구조를 Rhombohedral 구조로 바꾸기 때문인 것으로 보였으며 이러한 문제는 PZNN의 비율을 조절하여 0.875PZT-0.125PZNN 세라믹스를 선택함으로 인해 해결할 수 있었다. 그러나 여전히 낮은 $Q_m$값을 높이기 위해서 $Al_2O_3$를 첨가하였고 그 결과 시편의 tetragonality 감소와 $Q_m$값의 증가를 확인할 수 있었으나 그 첨가량이 0.2wt% 이상일 경우에는 밀도의 감소로 인한 압전특성의 저하가 나타났다. 밀도의 향상을 위해 Zn and Ni excess 조성을 선택하였고 그 결과 0.5wt% $MnO_2$와 0.2wt% CuO 그리고 0.3wt% $Al_2O_3$를 첨가한 0.875PZT-0.125PZNN 세라믹스(Zn and Ni excess 조성)를 $920^{\circ}C$에서 소결한 경우 $k_p=0.581,\;Q_m=809,\;d_{33}=345\;pC/N\;and\;{\varepsilon}_{33}/{\varepsilon}_0=1345$의 빼어난 압전 및 유전특성과 $330^{\circ}C$의 높은 $T_c$를 보였고 그 조성의 vibration velocity는 약4.5 m/s로 나타났다.

  • PDF

C57BL/6 쥐 외상성 뇌손상 모델에서 뇌 손상 정도에 따른 조직병리학적 변화 및 신경행동학적 특징 (Histopathological and Neurobehavioral Characterization in Adult Mice Exposed to Traumatic Brain Injury)

  • 오기영;최동원;장문순;이지한;김상철;박정수;이석우;김훈
    • 대한응급의학회지
    • /
    • 제28권5호
    • /
    • pp.457-466
    • /
    • 2017
  • Purpose: Traumatic brain injury (TBI) is a significant cause of morbidity and mortality worldwide. Severity of the initial insult is one of the most significant factors affecting outcome following TBI. In order to investigate the mechanisms of cellular injury and develop novel therapeutic strategies for TBI, we designed a standardized animal TBI model and evaluated histological and functional outcomes according to the degree of impact severity. Methods: Male adult C57Bl/6 mice underwent controlled cortical impact (CCI) at varying depths of deflection (1.0-2.0 mm). We performed hematoxylin and eosin staining at 7 days after recovery from TBI. Neurobehavioral characterization after TBI was analyzed by the Barnes maze test, passive avoidance test, open field test, rotarod test, tail suspension test, and light/dark test. Results: We observed a graded injury response according to the degree of deflection depths tested (diameter, 3 mm; velocity, 3 m/s; and duration, 500 ms) compared to sham controls. In the Barnes maze test, the severe TBI (2 mm depth) group showed reduced spatial memory as compared with the sham and mild TBI (1 mm depth) groups at 7 days after TBI. There was a significant difference in the results of the open field test and light/dark test among the three groups. Conclusion: Our findings demonstrate that the graded injury responses following TBI resulted in differential histopathological and behavioral outcomes in a mouse experimental CCI model. Thus, a model of CCI with histologic/behavioral outcome analysis may offer a reliable and convenient design for preclinical TBI research involving mice.

아킬레스건 파열 수술 후 걷기 및 달리기 운동역학적 분석 (Biomechanical Analysis of Walking and Running after a Surgically Repaired Achilles Tendon Rupture)

  • Heo, Jeong;Park, Sang-Kyoon
    • 한국운동역학회지
    • /
    • 제31권4호
    • /
    • pp.241-248
    • /
    • 2021
  • Objective: The purpose of this study was to investigate the difference in muscle strength, kinematics, and kinetics between injured and non-injured sides of the leg after Achilles Tendon Rupture surgery during walking and running. Method: The subjects (n=11; age = 30.63 ± 5.69 yrs; height = 172.00 ± 4.47 cm; mass = 77.00 ± 11.34 kg; time lapse from surgery = 29.81 ± 10.27 months) who experienced Achilles Tendon Rupture (ATR) surgery participated in this study. The walking and running trials were collected using infrared cameras (Oqus 300, Qualisys, Sweden, 100 Hz) on instrumented treadmill (Bertec, U.S.A., 1,000 Hz) and analyzed by using QTM (Qualisys Track Manager Ver. 2.15; Qualisys, U.S.A). The measured data were processed using Visual 3D (C-motion Inc., U.S.A.). The cutoff frequencies were set as 6 Hz and 12 Hz for walking and running kinematics respectively, while 100 Hz was used for force plate data. Results: In ATR group, muscle strength there were no difference between affected and unaffected sides (p> .05). In kinematic analysis, subjects showed greater ROM of knee joint flexion-extension in affected side compared to that of unaffected side during walking while smaller ROM of ankle dorsi-plantar and peak knee flexion were observed during running (p< .05). In kinetic analysis, subjects showed lower knee extension moment (running at 2.2 m/s) and positive ankle plantar-flexion power (running at 2.2 m/s, 3.3 m/s) in affected side compared to that of unaffected side (p< .05). This lower positive ankle joint power during a propulsive phase of running is related to slower ankle joint velocity in affected side of the subjects (p< .05). Conclusion: This study aimed to investigate the functional evaluation of the individuals after Achilles tendon rupture surgery through biomechanical analysis during walking and running trials. Based on the findings, greater reduction in dynamic joint function (i.e. lower positive ankle joint power) was found in the affected side of the leg compared to the unaffected side during running while there were no meaningful differences in ankle muscle strength and walking biomechanics. Therefore, before returning to daily life and sports activities, biomechanical analysis using more dynamic movements such as running and jumping trials followed by current clinical evaluations would be helpful in preventing Achilles tendon re-rupture or secondary injury.

저강도 혈류제한 복합운동이 여성노인들의 신체조성과 심혈관 요인들에 미치는 영향 (Effects of Low Intensity Combined Exercise Training with Blood Flow Restriction on Body Composition and Cardiovascular Responses in Elderly Females)

  • 김대열;국두홍;박혁
    • 한국산학기술학회논문지
    • /
    • 제20권1호
    • /
    • pp.362-370
    • /
    • 2019
  • 이 연구는 12주간 여성노인 실험참가자들의 혈류제한 복합운동 프로그램 참가 여부가 신체조성(몸무게, 체지방률, 근육량, 신체질량지수)와 심혈관인자(맥파속도와 혈관협착도)에 어떠한 영향을 미치는가에 대하여 연구 하고자 총 43명의 실험참가자가 혈류제한 복합운동(14명), 일반복합운동(14명)과 통제집단(15명)으로 무선할당 배분되어 본 연구를 참여하였다. 본 연구는 반복측정분산분석(Repeated Measure ANOVA)과 대비검증(contrast)을 이용하여 통계를 분석하였고, 모든 자료의 유의수준은 ${\alpha}=0.5$로 설정하였다. 연구결과 혈류제한 복합운동 집단의 신체조성(몸무게, 체지방률, BMI)에 통계적으로 유의한 변화가 나타났고, 일반복합운동 집단의 체지방률만 통계적으로 유의하게 감소하였다. 그리고 혈류제한 복합운동 집단의 오른쪽과 왼쪽의 맥파속도가 통계적으로 유의하게 감소하였고, 일반 복합운동 집단의 왼쪽 맥파속도만 통계적으로 유의하게 감소되었다. 또한 혈류제한 복합운동 집단의 사전과 사후 변화량($%{\Delta}$)과 효과크기(effect size)가 높이나왔다. 이는 동일한 운동(복합운동)을 수행하였지만 혈류제한 방법을 추가한 집단이 더욱 교감신경이 활성화된 운동을 실시하게 되어 여성노인들에게 신체조성과 심혈관 요인에 일반 복합운동 보다 더욱 긍정적인 영향을 미쳤음을 나타내고 있다.

수중 자율작업용 로봇 플랫폼 개발 (Development of Robot Platform for Autonomous Underwater Intervention)

  • 여태경;최현택;이윤건;채준보;이영준;김성순;박상현;이태희
    • 한국해양공학회지
    • /
    • 제33권2호
    • /
    • pp.168-177
    • /
    • 2019
  • KRISO (Korea Research Institute of Ship & Ocean Engineering) started a project to develop the core algorithms for autonomous intervention using an underwater robot in 2017. This paper introduces the development of the robot platform for the core algorithms, which is an ROV (Remotely Operated Vehicle) type with one 7-function manipulator. Before the detailed design of the robot platform, the 7E-MINI arm of the ECA Group was selected as the manipulator. It is an electrical type, with a weight of 51 kg in air (30 kg in water) and a full reach of 1.4 m. To design a platform with a small size and light weight to fit in a water tank, the medium-size manipulator was placed on the center of platform, and the structural analysis of the body frame was conducted by ABAQUS. The robot had an IMU (Inertial Measurement Unit), a DVL (Doppler Velocity Log), and a depth sensor for measuring the underwater position and attitude. To control the robot motion, eight thrusters were installed, four for vertical and the rest for horizontal motion. The operation system was composed of an on-board control station and operation S/W. The former included devices such as a 300 VDC power supplier, Fiber-Optic (F/O) to Ethernet communication converter, and main control PC. The latter was developed using an ROS (Robot Operation System) based on Linux. The basic performance of the manufactured robot platform was verified through a water tank test, where the robot was manually operated using a joystick, and the robot motion and attitude variation that resulted from the manipulator movement were closely observed.