The Numerical Formula Control Modeling Regarding on the Grounding Conductor Size Selecting (접지도체 굵기 산정에 관한 수식제어 모델링)

  • Song, Young-Joo;Choi, Hong-Kyoo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.4
    • /
    • pp.107-116
    • /
    • 2006
  • The international standard to determine grounding conductor size can be applied for a wide range of items because it includes the specific physical characteristics, but it has a problem where the numerical formula is complicated. However the JIS and domestic standard numerical formula are simple but have many constraints. The new grounding conductor size selecting method is necessary in order to solve such problems. Therefore, in this study, we suggested an improved method for selecting the grounding conductor size and simple numerical formula with a numerical formula control modeling. and we verified reliability of paper used case study.

Miniaturization of Parallel Coupled-Line Filter using Lumped Capacitors and Grounding (집중 소자 캐패시터와 접지를 이용한 평행 결합 선로 필터의 소형화 연구)

  • Myoung Seong-Sik;Yook Jong-Gwan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.15 no.9
    • /
    • pp.888-895
    • /
    • 2004
  • This paper proposes new miniaturization method of parallel coupled line filter by using capacitors and grounding. Proposed method can reduce resonator size by using only a small number of capacitor and grounding of parallel coupled line filter which is conventional in field of RF filters because of its design and fabrication simplicity. This paper applies the miniaturization method of transmission line and parallel coupled line to parallel coupled line filter, and presents that grounding can reduce the number of shut capacitors. Presented miniaturized method has merits of miniaturization of parallel coupled line, harmonic suppression, and improvement of high frequency skirt with harmonic suppression. For verification of proposed method, this paper presents a hairpin filter, which has 900 MHz center frequency and 10 % FBW, miniaturized to λ/4 by proposed method.

A study on the Interpretation Technique of Fall-Of-Potential Curve for Grounding Performance Evaluation of a Large Grounding Electrode Network (대규모 접지전극 망의 접지성능 평가를 위한 겉보기저항곡선의 해석에 관한 연구)

  • Choi, Jong-Kee;Ryu, Hee-Young;Lee, Dongil;Jung, Gil-Jo;Kim, Kyung-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.2
    • /
    • pp.49-54
    • /
    • 2005
  • Measuring ground resistance is a typical way of performance evaluation of a grounding electrode. Among various ground resistance measurement methods, FOP (Fall-Of-Potential) method has been widely used, especially in case of a relatively large grounding electrode such as a substation grounding mesh grid Since FOP measurement line has to be increased as the size of grounding electrode increases, however, it is often that securing long enough FOP-line is practically impossible. In this paper, a sophisticated interpretation method of FOP measurement ma which is applicable to large grounding electrode networks, is presented.

Measurement of the Ground Resistance using the Fall-of-Potential Method with the Vertically-placed Current and Potential Auxiliary Electrodes (전류 및 전위 보조전극을 수직으로 배치하는 전위강하법을 이용한 접지저항의 측정)

  • Lee, Bok-Hee;Kim, Ki-Bok;Kim, You-Ha
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.3
    • /
    • pp.53-60
    • /
    • 2012
  • The fall-of-potential method is commonly used in measuring the ground resistance of large-scaled grounding system and the current and potential auxiliary electrodes are horizontally arranged. Because the distances between the ground grid to be tested and auxiliary electrodes are limited in downtown areas, it is very difficult to measure accurately the ground resistance of large-scaled grounding system. In this paper, the fall-of-potential method of measuring the ground resistance with the vertically-placed current and potential auxiliary electrodes was examined and discussed. The validity and good accuracy of the proposed method of measuring the ground resistance were confirmed through various simulations and actual tests carried out in uniform and two-layer soil structures.

Measurement of Impedance of the Grounding Grid using Variable Frequency Inverter (가변주파수 인버터를 이용한 접지임피던스 측정)

  • 이복희;엄주홍;김교운
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.303-306
    • /
    • 2002
  • This paper presents a novel method for measuring the ground impedance in grounding systems. A square wave current was injected to the main grounding grid through auxiliary electrode, and the test current and ground potential rise(GPR) were measured using the band-pass filter. Ground impedance was calculated from the sinusoidal waveforms of the test current and GPR in frequency range of 20~2100Hz. Also the resistance and reactance component of ground impedance were analyzed.

  • PDF

Optimization of protection System on the Railway High Voltage power System (철도 고압배전계통의 보호시스템 최적화 방안 연구)

  • 조웅기;창상훈;한성호;김왕곤
    • Proceedings of the KSR Conference
    • /
    • 2002.10b
    • /
    • pp.989-994
    • /
    • 2002
  • In case the fault occurs in railway high voltage power supply network, protective relaying system must selectively detect 1 wire ground fault of grounding or non-grounding system. And this study presents railway high voltage power supply system model using PSCAD/EMTDC Vet 3.08 for circuit analysis and fault studies. In this paper, we propose protection method of non-grounding system of railway high voltage power supply system. The result shows its usefulness.

  • PDF

The study on the prevention of DC feeder line cable grounding fault (DC 급전케이블 지락사고 보호방안에 관한 연구)

  • Park, Ji-Soo;Song, Joong-Ho;Park, Joung-Wook
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.202-207
    • /
    • 2008
  • This study provides review and improvement plans for the possible problems caused when the CV cable is used as a positive feeder line which supplies power from the DC HSCB (high-speed circuit breaker) to the catenariesin Seoul Metro which is using direct-current feeder method. In detail, this study contributes to stabilizing the power line by triggering a protective device by instantly detecting potential rise which happens when grounding fault occurs in non-grounding type CV cable shield.

  • PDF

Corrosion Performance of Cu Bonded Grounding-Electrode by Accelerated Corrosion Test

  • Choi, Sun Kyu;Kim, Kyung Chul
    • Corrosion Science and Technology
    • /
    • v.17 no.5
    • /
    • pp.211-217
    • /
    • 2018
  • Natural degradation of grounding-electrode in soil environment should be monitored for several decades to predict the lifetime of the grounding electrode for efficient application and management. However, long-term studies for such electrodes have many practical limitations. The conventional accelerated corrosion test is unsuitable for such studies because simulated soil corrosion process cannot represent the actual soil environment. A preliminary experiment of accelerated corrosion test was conducted using existing test standards. The accelerated corrosion test that reflects the actual soil environment has been developed to evaluate corrosion performances of grounding-electrodes in a short period. Several test conditions with different chamber temperatures and salt spray were used to imitate actual field conditions based on ASTM B162, ASTM B117, and ISO 14993 standards. Accelerated degradation specimens of copper-bonded electrodes were made by the facile method and their corrosion performances were investigated. Their corrosion rates were calculated to $0.042{\mu}m/day$, $0.316{\mu}m/day$, and $0.11{\mu}m/day$, respectively. These results indicate that accelerated deterioration of grounding materials can be determined in a short period by using cyclic test condition with salt spray temperature of $50^{\circ}C$.

Measurement method of ground impedance for the grounding grid (접지그리드의 접지임피던스 측정 기법)

  • Lee, Bok-Hee;Choi, Jong-Hyuk;Choi, Young-Chul;Yoo, Jae-Duk;Beak, Young-Hwan;Kim, Dong-Seong;Shin, Hee-Kyung;Yoo, Yang-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1487_1488
    • /
    • 2009
  • In these days, the common grounding systems are adapted in most large structures. In order to evaluate the performance of grounding system, it is needed to measure ground impedance. Measuring methods of ground impedance for a large scale grounding systems have not been yet presented in detail. In this paper, we analyze earth mutual resistance and mutual coupling of $15{\times}15m$ grounding grid in different arrangements of auxiliary electrode. As a results, the auxiliary electrodes are installed where the error rate due to earth mutual resistance is less than 5%. Also, the potential lead is installed at obtuse angle from the current lead and the overlapped length between potential lead and grounding grid are minimized.

  • PDF

A Study on the Configuration Method of CCPU for Lightning Surge in Underground Transmission System (지중송전계통의 방식층 보호장치 결선방식에 대한 뇌써어지 해석)

  • Kim, Dae-Kyeong;Jeong, Seong-Hwan;Lee, Jong-Bum;Kim, Jeom-Shik
    • Proceedings of the KIEE Conference
    • /
    • 1997.07c
    • /
    • pp.1018-1020
    • /
    • 1997
  • This paper is compared the configuration method of cable cover protection unit with respect to the lightning surge in 154kV underground transmission system. There are many methods of connecting CCPU, i.e, a conventional method, CIGRE method, inter-connection between sheath with grounding, and interconnection between sheath without grounding.

  • PDF