• 제목/요약/키워드: Ground vibrations

검색결과 162건 처리시간 0.025초

Wind-induced responses and dynamic characteristics of a super-tall building under a typhoon event

  • Hua, X.G.;Xu, K.;Wang, Y.W.;Wen, Q.;Chen, Z.Q.
    • Smart Structures and Systems
    • /
    • 제25권1호
    • /
    • pp.81-96
    • /
    • 2020
  • Wind measurements were made on the Canton Tower at a height of 461 m above ground during the Typhoon Vincente, the wind-induced accelerations and displacements of the tower were recorded as well. Comparisons of measured wind parameters at upper level of atmospheric boundary layer with those adopted in wind tunnel testing were presented. The measured turbulence intensity can be smaller than the design value, indicating that the wind tunnel testing may underestimate the crosswind structural responses for certain lock-in velocity range of vortex shedding. Analyses of peak factors and power spectral density for acceleration response shows that the crosswind responses are a combination of gust-induced buffeting and vortex-induced vibrations in the certain range of wind directions. The identified modal frequencies and mode shapes from acceleration data are found to be in good agreement with existing experimental results and the prediction from the finite element model. The damping ratios increase with amplitude of vibration or equivalently wind velocity which may be attributed to aerodynamic damping. In addition, the natural frequencies determined from the measured displacement are very close to those determined from the acceleration data for the first two modes. Finally, the relation between displacement responses and wind speed/direction was investigated.

점탄성 감쇠기를 설치한 2/5 축척 강구조물의 지진하중에 의한 거동연구 (Seismic Behavior of A 2/5-Scale Steel Structure with Added Viscoelastic Dampers)

  • Oh, Soon-Taek
    • 한국안전학회지
    • /
    • 제8권1호
    • /
    • pp.80-87
    • /
    • 1993
  • 본 논문은 에너지 분산 장치의 일종인 점탄성 감쇠기를 설치한 건물의 거동에 관한 실험 및 해석적 연구를 다루고자 한다. 지진 모형 실험 장치를 이용하여 감쇠기를 설치한 건물의 구조응답을 구하고. 이를 감쇠기를 설치하지 않은 건물에 대하여 행해진 비탄성 해석 결과와 비교한다. 결론적으로 말하면. 점탄성 감쇠기는 강지진 하중에 의하여 건물에 발생한 과도한 진동을 감소시키는데 효과적이다 일반적으로 점탄성 감쇠기를 건물에 설치함으로써 감쇠비와 함께 강성도가 증가하여 지진 응답을 감소시키는데 기여하나, 대부분은 감쇠기의 역할에 의해 증가된 감쇠비의 영향인 것으로 밝혀졌다. 모드 변형에너지법을 이용하여 감쇠기에 의해 증가된 등가구조 감쇠를 성공적으로 예측할 수 있으며 따라서 점탄성 감쇠기를 설치한 건물의 지진 응답이 일반적인 모드 해석 기법을 이용한 수치모형해석에 의해 정확히 예측된다.

  • PDF

Hall Effect Sensor와 9-Axis Sensor를 이용한 Expansion Joint 모션 분석 (Expansion Joint Motion Analysis using Hall Effect Sensor and 9-Axis Sensor)

  • 곽태홍;김상현;김원중
    • 한국전자통신학회논문지
    • /
    • 제16권2호
    • /
    • pp.347-354
    • /
    • 2021
  • 화학공장과 같은 장치산업은 고온·고압·유독성 유체가 배관을 통하여 각종 설비들 사이를 이동한다. 온도변화, 진동, 지진, 지반침하와 같은 주변환경의 변화에 의한 배관의 위치 이동과 파손은 인명피해를 수반하는 큰 사고로 연결되는 경우가 많다. 이러한 사고를 방지하기 위하여 배관에 가해지는 각종 충격을 흡수하고, 보완하여 사고를 미연에 방지하기 위한 여러 가지 종류의 익스펜션 조인트(Expansion Joint)를 사용한다. 따라서 사용된 익스펜션 조인트의 변형을 측정하고, 수명을 예측하는 것은 대형사고를 방지하기 위하여 매우 중요하다. 본 논문에서는 익스펜션 조인트의 변형을 일종의 모션으로 이해하고, Hall Effect Sensor와 9-Axis Sensor를 사용하여 변화를 측정하였다. 그리고 범용의 마이컴보드 아두이노와 C언어를 사용하여 측정된 데이터를 모으고, 분석하여 익스펜션 조인트의 변형을 예측할 수 있는 시스템에 대하여 연구하였다.

Seismic pounding effects on the adjacent symmetric buildings with eccentric alignment

  • Abdel Raheem, Shehata E.;Fooly, Mohamed Y.M.;Omar, Mohamed;Abdel Zaher, Ahmed K.
    • Earthquakes and Structures
    • /
    • 제16권6호
    • /
    • pp.715-726
    • /
    • 2019
  • Several municipal seismic vulnerability investigations have been identified pounding of adjacent structures as one of the main hazards due to the constrained separation distance between adjacent buildings. Consequently, an assessment of the seismic pounding risk of buildings is superficial in future adjustment of design code provisions for buildings. The seismic lateral oscillation of adjacent buildings with eccentric alignment is partly restrained, and therefore a torsional response demand is induced in the building under earthquake excitation due to eccentric pounding. In this paper, the influence of the eccentric seismic pounding on the design demands for adjacent symmetric buildings with eccentric alignment is presented. A mathematical simulation is formulated to evaluate the eccentric pounding effects on the seismic design demands of adjacent buildings, where the seismic response analysis of adjacent buildings in series during collisions is investigated for various design parameters that include number of stories; in-plan alignment configurations, and then compared with that for no-pounding case. According to the herein outcomes, the effects of seismic pounding severity is mainly depending on characteristics of vibrations of the adjacent buildings and on the characteristics of input ground motions as well. The position of the building wherever exterior or interior alignment also, influences the seismic pounding severity as the effect of exposed direction from one or two sides. The response of acceleration and the shear force demands appear to be greater in case of adjacent buildings as seismic pounding at different levels of stories, than that in case of no-pounding buildings. The results confirm that torsional oscillations due to eccentric pounding play a significant role in the overall pounding-involved response of symmetric buildings under earthquake excitation due to horizontal eccentric alignment.

제진형 배전반의 진동 및 환경 데이터수집을 위한 IoT 시스템 구현 (Implementation of IoT System for Wireless Acquisition of Vibration and Environmental Data in Distributing Board)

  • 이병영;이영동
    • 융합신호처리학회논문지
    • /
    • 제22권4호
    • /
    • pp.199-205
    • /
    • 2021
  • 수배전반의 경우 지면 또는 건물의 바닥 면에 바로 설치되며 지진과 같은 진동이나 외부 충격 발생 시 수배전반의 내부 전력기기, 배선 그리고 보호계전기 등의 전기부품 손상, 오동작 발생 가능성이 커지게 된다. 이러한 이유로 최근 내진형 수배전반의 필요성이 대두되고 있으며, 제진기능을 갖는 수배전반의 연구 개발 및 제품 출시가 이루어지고 있다. 본 논문에서는 제진형 배전반의 진동, 온도, 습도 등을 측정할 수 있는 제진형 배전반의 진동 및 환경 데이터수집을 위한 IoT 시스템을 구현하였다. 제진형 배전반에 진동이 발생하였을 때 진동 정도 및 온습도 데이터를 측정하고 신뢰성 있는 메시징 전송을 위한 MQTT 프로토콜을 사용하였고, 모니터링과 데이터 저장은 Node-RED를 통해 MySQL DB에 데이터를 저장하고, 시각화를 진행하였다. 제진형 배전반에 IoT 기기를 부착하여 테스트를 진행 하였으며, 데이터를 실시간으로 수집하고 Node-RED의 대시보드 UI에서 진동 및 환경 데이터의 변화를 모니터링 하였다.

Estimation of liquid limit of cohesive soil using video-based vibration measurement

  • Matthew Sands;Evan Hayes;Soonkie Nam;Jinki Kim
    • Geomechanics and Engineering
    • /
    • 제33권2호
    • /
    • pp.175-182
    • /
    • 2023
  • In general, the design of structures and its construction processes are fundamentally dependent on their foundation and supporting ground. Thus, it is imperative to understand the behavior of the soil under certain stress and drainage conditions. As it is well known that certain characteristics and behaviors of soils with fines are highly dependent on water content, it is critical to accurately measure and identify the status of the soils in terms of water contents. Liquid limit is one of the important soil index properties to define such characteristics. However, liquid limit measurement can be affected by the proficiency of the operator. On the other hand, dynamic properties of soils are also necessary in many different applications and current testing methods often require special equipment in the laboratory, which is often expensive and sensitive to test conditions. In order to address these concerns and advance the state of the art, this study explores a novel method to determine the liquid limit of cohesive soil by employing video-based vibration analysis. In this research, the modal characteristics of cohesive soil columns are extracted from videos by utilizing phase-based motion estimation. By utilizing the proposed method that analyzes the optical flow in every pixel of the series of frames that effectively represents the motion of corresponding points of the soil specimen, the vibration characteristics of the entire soil specimen could be assessed in a non-contact and non-destructive manner. The experimental investigation results compared with the liquid limit determined by the standard method verify that the proposed method reliably and straightforwardly identifies the liquid limit of clay. It is envisioned that the proposed approach could be applied to measuring liquid limit of soil in practical field, entertaining its simple implementation that only requires a digital camera or even a smartphone without the need for special equipment that may be subject to the proficiency of the operator.

발파 진동으로 인한 지표면 진동 계측 범위 산정에 대한 연구 (Prediction for Measurement Range of Vibration due to Blasting of Underground Tunneling)

  • 공석민;변요셉;최상일;김정흠;김창용;이성원
    • 한국지반공학회논문집
    • /
    • 제40권2호
    • /
    • pp.7-17
    • /
    • 2024
  • 지하터널 굴착 시 발파로 인한 진동의 영향이 지표면에 미치는 영향을 분석하기 위해 GTX-A 굴착현장 상부에서 진동을 측정하였다. 또한 해당 현장과 동일한 지반조건 및 발파조건으로 역해석을 실시하였으며, 이를 바탕으로 다른 GTX-A 노선 현장들에 대해서 수치해석을 실시하여 비교·분석하였다. 수치해석을 통해 각 현장의 발파지점 직상부로 부터 일정 간격으로 최대 진동속도를 도출하였으며, 결과 값을 국내·외 진동 허용기준과 비교하여 진동 계측의 영향 범위를 산정하였다. 이를 통해 국내 규정에서 "발파원으로부터 가장 근접한 구조물 기초 부위에서 측정하고 여건상 불가능한 경우 이에 근접한 지표에서 측정"으로 명시되어 있는 지반진동 측정 위치에 대해 보다 명확한 진동 계측 위치를 산정하였다.

간척지 온실 기초의 침하량 검토 (Settlement Instrumentation of Greenhouse Foundation in Reclaimed Land)

  • 최만권;윤성욱;유인호;이종원;이시영;윤용철
    • 생물환경조절학회지
    • /
    • 제24권2호
    • /
    • pp.85-92
    • /
    • 2015
  • 본 연구에서는 간척지 내에 온실을 시공할 경우, 온실 설계의 기초자료로 활용하기 위하여 최근 나무말뚝 기초를 사용하여 완공한 계화도 간척지의 1-2W형 온실을 대상으로 온실기초의 침하량을 계측하고 검토하였다. 그 결과는 다음과 같다. 지반조사 결과, 기반암인 연암층은 확인되지 않았으며 부지 조성 당시 매립한 것으로 추정되는 매립층과 그 하부에 퇴적층이 존재하는 것으로 조사되었다. 그리고 매립층과 퇴적층 하부에 풍화대가 존재하는 것으로 조사되었다. 전체 지반층의 토성은 시추공에 관계없이 주로 점토 섞인 모래, 실트질 모래, 실트질 점토 및 화강편마암 순으로 구성되어 있었다. 지하수위도 시추공에 관계없이 지반에서 0.3m 아래에 있는 것으로 나타났다. 온실기초 및 나무말뚝의 침하량은 전체적으로 볼 때, 온실 내 외부나 계측지점(채널)에 관계없이 침하량에는 다소 차이가 있지만, 시간의 경과와 함께 침하량이 증가하고 있는 것으로 나타났다. 그리고 온실 내부 기둥의 경우, CH-2는 좀 예외적이긴 하지만, 온실 측벽(방풍벽 측)에 있는 지점의 데이터가 상대적으로 큰 진폭으로 흔들리는 것은 알 수 있었다. 또한 특정 시기에 침하량이 상대적으로 크게 증가한 후, 어느 정도 침하량이 회복 되는 현상을 볼 수 있었다. 이와 같은 현상들을 포함하여 CH-1을 제외하고 현 시점에서 온실 내 외부 전체의 지점별(CH-2~CH-10) 침하량은 1.0~7.5mm 정도의 범위에 있는 것으로 나타났다. 회귀 분석한 결과 결정계수는 지점별로 0.6362~0.9340까지의 범위로서 상관관계가 높은 것으로 나타났다. 그리고 온실외부의 경우는 0.6046~0.8822로서 온실내부 보다는 다소 낮지만, 상관관계가 있는 것으로 나타났다.

불규칙한 층상구조 지반에서의 발파진동 분석 (Analysis of Blasting Vibration at the Irregular Layered Structure Ground)

  • 김승현;이동욱
    • 대한토목학회논문집
    • /
    • 제36권5호
    • /
    • pp.891-901
    • /
    • 2016
  • 측상구조를 갖는 다변성 지반에서 시행된 3개소 24회의 시험발파로부터 획득한 발파진동 데이터를 지층단면도와 연계하여 제어가 불가능한 지반 특성으로 인한 발파진동 영향을 분석하였다. 화산쇄설층인 클링커층이 불규칙하게 반복되는 층상구조에 대한 발파공학적 경험과 자료의 부족 등으로 충분한 검토가 이루어지지 않은 비효율적인 발파가 이루어지고 있다. 시험발파 지역 내 클링커층의 N값은 매우 다양한 범위로 나타나 정량화하기 매우 어렵다. 그리고 현장의 전체 발파진동 추정식(SRSD)은 감쇠지수 n의 절대값이 설계지침보다 작게 나타나 발파진동이 멀리 전파되었으며, 발파진동상수 K와 감쇠지수 n이 상대적으로 매우 작은 값을 보인 시험발파. 1의 진동특성을 지층단면도로부터 유추한 결과, 연암층 하부에 접한 클링커층 인근까지 발파천공이 진행되어 발파 시 하부에 넓게 분포하고 있는 클링커층으로 폭발 가스압이 손실되었을 것으로 판단된다. 이로 인해 암파쇄량도 절반정도로 감소하였다. 그리고 현장의 주주파수 대역은 일반적인 구조물의 고유 주파수 대역과 유사한 저주파수 대역으로 확인되었다.

터널 굴착 발파하중 시간이력 생성 (Generation of blast load time series under tunnelling)

  • 안재광;박두희;신영완;박인준
    • 한국터널지하공간학회 논문집
    • /
    • 제16권1호
    • /
    • pp.51-61
    • /
    • 2014
  • 발파가 인근 시설물에 미치는 영향을 수치적으로 규명하기 위해서는 발파하중 시간이력을 적용한 동적 해석을 수행해야 한다. 발파하중은 실측하기 어렵기에 다양한 참고문헌에서 제시된 경험적 시간이력이 일반적으로 사용된다. 경험적 폭굉압과 시간이력은 다양한 환경변수를 고려하여 보정해야 하지만 이에 대한 가이드라인이 명확하게 제시되지 않아 해석에 어려움이 있다. 본 연구에서는 시험발파를 모사하는 2차원 동적 수치해석을 수행하여 계측기록과 상응하는 경험적 발파하중 시간이력을 도출하였다. 발파로 인한 파쇄영역은 원형으로 가정하여 모델링 하였으며 발파하중을 경계벽에 수직방향으로 재하하였다. 특히, 해석 결과에 지반의 감쇠비는 큰 영향을 미칠 수 있으므로 이를 정확하게 산정해야 한다. 시험적으로 계산된 감쇠식의 기울기는 발파하중의 크기에는 영향을 받지 않으며 하중의 주파수와 지반의 감쇠비에 의해서만 결정되므로 지반 감쇠비는 발파 감쇠식에 상응하도록 결정하였다. 해석 결과, 발파하중은 암반의 파쇄에 소요되는 에너지 손실을 고려하지 않으므로 이를 보정없이 적용할 경우 발파로 인하여 유발되는 진동을 크게 과대예측하므로 이를 감소시켜야 하는 것으로 나타났다.