• Title/Summary/Keyword: Ground Surface Area

Search Result 709, Processing Time 0.027 seconds

A Case Study of Reinforcing Ground behind Abutment using Twin-Jet Method (트윈제트공법을 이용한 교대 배면 기초보강 사례)

  • Kim, Yong-Hyun;Jang, Yeon-Soo
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09a
    • /
    • pp.638-645
    • /
    • 2010
  • This study introduces a reinforcement work case using Twin-Jet Method. The area is located behind the abutment of the bridges built on soft clay along the $\bigcirc\bigcirc$ Express Highway. Its foundation was constructed by installing EPS blocks on the original ground to reduce the embankment load under the highway. However, the ground deformation has continuously occurred due to the settlement of the foundation soft cohesive soils. The amounts of subsidences at the surface turned out to be 20~30.0mm, After the pavement patch work on April 23, 2009, a drastic subsidence occurred together with 10mm swell, For this reason, Twin-Jet grout column construction was applied by passing through the EPS banking blocks without closing traffic flows on the express highway. The outcomes of core sample tests after reinforcing the ground turned out to be TCR 92.5%, RQD 64.6% and unconfined compressive strength 2.3~8.6Mpa. The test results showed that the condition of the ground foundation had improved using Twin-Jet grouting in most layers of ground including the cobble and gravel layer.

  • PDF

Study on the Characteristics of the Slow-moving Landslide (Landcreep) in the Sanji Valley of Jinju (진주시 산지골 유역내 땅밀림지 특성에 관한 연구)

  • Park, Jae-Hyeon;Kim, Seon Yeop;Lee, Sang Hyeon;Kang, Han Byoel
    • Journal of Korean Society of Forest Science
    • /
    • v.111 no.1
    • /
    • pp.115-124
    • /
    • 2022
  • This study was conducted to obtain basic data that could help prevent damage caused by slow-moving landslides (land-creep). Specifically, the geological, topographic, and physical characteristics of land-creep were analyzed in Jiphyeon-myeon, Jinju-si. The first and second analyzed land-creeps occurred in 1982 and 2019, respectively. The area damaged in the second land-creep was about 11.5-fold larger than that damaged in the first land-creep. The dominant constituent rock in the land-creep area was sedimentary rock, which seems to be weakly resistant to weathering. The areas that collapsed due to land-creep were related to the presence of separated rocks between the bedding plane in the estimated activity surface over the slope direction and the vertically developed joint surface. Thus, surface water and soil debris were introduced through the gaps of separated rocks. Additionally, the areas collapsed due to the combination of the bedding plane and joint surface shale and sandstone showed an onion structure of weathered outcrop from the edge to inner part caused by weathering from ground water. Consequently, core stones were formed. The study area was a typical area of land-creep in a mountain caused by ground water. Land-creep was classified into convex areas of colluvial land-creep. The landslide-risk rating in the study area was classified into three and five classes. The flow of ground water moved to the northeast and coincided with the direction of the collapse. Soil bulk density in the collapsed area was lower than that in ridge area, which was rarely affected by land-creep. Thus, soil bulk density was affected by the soil disturbance in the collapsed area.

Characteristics of Spectral Reflectance in Tidal Flats

  • Ryu, Joo-Hyung;Na, Young-Ho;Choi, Jong-Kook;Won, Joong-Sun
    • Proceedings of the KSRS Conference
    • /
    • 2002.10a
    • /
    • pp.734-738
    • /
    • 2002
  • We present spectral characteristics of tidal flat sediments and algal mat that were tested in the Gomso and Saemangum tidal flats, Korea. The objective of this study is to investigate the spectral reflectance and the radar scattering modeling in the tidal flats. Ground truth data obtained in the tidal flats include grain size, soil moisture content and its variation with time, surface roughness, chlorophyll, ground leveling, and field spectral reflectance measurement. The concept of an effective exposed area (EEA) is introduced to accommodate the effect of remnant surface water, and it seriously affects the reflection of short wavelength infrared and microwave. The nin size of 0.0625 mm has been normally used as a critical size of mud and sand discrimination. But we propose here that 0.25 mm is more practical grain size criterion to discriminate by remote sensing. Algal mat is the primary product in tidal flats, and it is found to be very important to understand spectral characteristics for tidal flat remote sensing. We have also conducted radar scattering modeling, and showed L-band HV-polarization would be the most effective combination.

  • PDF

Effects of Size and Shape of Drain on Horizontal Vacuum Drain (배수재의 직경과 형상변화가 수평진공배수에 미치는 영향)

  • Yoo, Nam-Jae;Park, Byung-Soo;Jeong, Gil-Soo;Lee, Byung-Kon
    • Journal of Industrial Technology
    • /
    • v.21 no.A
    • /
    • pp.293-301
    • /
    • 2001
  • This paper is experimental results of investigating the efficiency of horizontal vacuum drainage system. Effects of size and shape of drain on horizontal vacuum drainage were studied. Model tests in the laboratory with soft marine clay were carried out with drain pipe of having three different diameters and PBD (Plastic Board Drain) of strip shape so that consolidation settlement of soft clay due to applied vacuum pressure, amount of discharge, ground settlement and distributions of pore pressure and undrained shear strength were measured during testing. From results of model test, amount of discharge due to vacuum pressure was increased with the diameter of pipe drain whereas the drain efficiency of pipe in per unit area of drain surface was decreased with diameter of pipe. The rate of discharge per unit time was reduced very fast with diameter of pipe. Settlement of ground surface with time was increased with diameter of pipe as a result of increase of discharge to drain pipe.

  • PDF

Spherical Signature Description of 3D Point Cloud and Environmental Feature Learning based on Deep Belief Nets for Urban Structure Classification (도시 구조물 분류를 위한 3차원 점 군의 구형 특징 표현과 심층 신뢰 신경망 기반의 환경 형상 학습)

  • Lee, Sejin;Kim, Donghyun
    • The Journal of Korea Robotics Society
    • /
    • v.11 no.3
    • /
    • pp.115-126
    • /
    • 2016
  • This paper suggests the method of the spherical signature description of 3D point clouds taken from the laser range scanner on the ground vehicle. Based on the spherical signature description of each point, the extractor of significant environmental features is learned by the Deep Belief Nets for the urban structure classification. Arbitrary point among the 3D point cloud can represents its signature in its sky surface by using several neighborhood points. The unit spherical surface centered on that point can be considered to accumulate the evidence of each angular tessellation. According to a kind of point area such as wall, ground, tree, car, and so on, the results of spherical signature description look so different each other. These data can be applied into the Deep Belief Nets, which is one of the Deep Neural Networks, for learning the environmental feature extractor. With this learned feature extractor, 3D points can be classified due to its urban structures well. Experimental results prove that the proposed method based on the spherical signature description and the Deep Belief Nets is suitable for the mobile robots in terms of the classification accuracy.

창원지역 지하수 수질과 DRASTIC에 의한 지하수 오염취약성 평가

  • 김무진;함세영;정재열;장성;차용훈
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.04a
    • /
    • pp.459-462
    • /
    • 2004
  • This study assesses groundwater vulnerability to contaminants in 12 administrative districts of the city of Changwon, using DRASTIC technique. DRASTIC was originally applied to situations in which the contamination sources are at the ground surface, and the contaminants flow into the groundwater with infiltration of rainfall. However, groundwater contamination in urban areas can also be related to excessive pumping resulting in a lowering of the water level. The correlation coefficient between minimum DRASTIC indices and the degree of poor water quality for 10 districts is low as 0.40. The correlation coefficients between minimum DRASTIC indices and the groundwater discharge rate, and between minimum DRASTIC indices and well density per unit area are 0.70 and 0.87, respectively. Thus, to evaluate the potential of groundwater contamination in urban areas, it is necessary to consider other factors such as groundwater withdrawal rate and well density per unit area with ratings and weights as well as the existing six DRASTIC factors.

  • PDF

Groundwater Flow and Water Budget Analyses using HydroGeoSphere Model at the Facility Agricultural Complex (시설농업단지에서 HydroGeoSphere 모델을 이용한 지하수 유동 및 물수지 분석)

  • Kang, Dong-hwan;So, Yoon Hwan;Kim, Il Kyu;Oh, Se-bong;Kim, Suhong;Kim, Byung-Woo
    • The Journal of Engineering Geology
    • /
    • v.27 no.3
    • /
    • pp.313-322
    • /
    • 2017
  • The purpose of this study is to estimate the surface and subsurface flows through the modelling of the model area and facility agricultural complex, and to calculate the groundwater recharge rate through water budget analysis. From results of surface flow modeling, the surface water is flowed to a depth of about 1 to 5 meters from the upper region (northeast) to the lower region (southeast) of the Miryang River. At the M01 point (upper), the observed surface water flux and the model surface water flux are consistent. At the M02 points (lower), the observed surface water flux and the model surface water flux are a difference of 1%. From results of subsurface flow modeling, the depth of groundwater is similar to elevation in the river and higher to the forest area. Ground water depth considering groundwater pumping is that the model values appears higher than the observed values to be within 1.5 m. From results of surface-subsurface integrated modeling, the groundwater recharge area is estimated about 90% of the model area, and the groundwater recharge rate is estimated $1.92{\times}10^5m^3/day$. From results of annual water budget analysis, the groundwater recharge rate per unit area is estimated to be 503.9 mm/year, and average annual rainfall is estimated at around 39%.

Rheological Properties of Ordinary Portland Cement - Blast Furnace Slag - Fly Ash Blends Containing Ground Fly Ash (분쇄된 플라이애시를 혼합한 3성분계 시멘트의 유동특성)

  • Park, Hyo-Sang;Yoo, Dong-Woo;Byun, Seung-Ho;Song, Jong-Taek
    • Journal of the Korean Ceramic Society
    • /
    • v.46 no.1
    • /
    • pp.58-68
    • /
    • 2009
  • In this study, rheological properties of ternary system cement containing ground fly ash(F3, Blaine specific surface area $8,100\;cm^2/g$) were investigated using mini slump, coaxial cylinder viscometer and conduction calorimeter. In the results, the segregation resistance was observed at high W/B and PC area while the replacement ratio of F3 was increasing. The 2:5:3 system was shown in higher fluidity and lower hydration heat than 3:4:3 system. The segregation range of cement pastes occurred over 175 mm in average diameter by mini slump and below $10\;dynesec/cm^2$ of the plastic viscosity or below 50 cP of the yield stress by coaxial cylinder viscometer. It was observed that even if BFS and FA blended together admixture properties would remaine as they were separately. The properties of admixture would not be changed. On the above results, the decreased replacement ratio of OPC and increased replacement ratio of admixtures would be possible.

A Tunnel Blasting Method Favorable to the Environment, which Utilizes Pre-splitting & an Upper Center Cut. (선균열과 상부 심빼기를 이용한 환경 친화적 터널발파공법)

  • 김일중;김영석;기경철
    • Explosives and Blasting
    • /
    • v.20 no.2
    • /
    • pp.7-19
    • /
    • 2002
  • The cut is placed high up in the section, the 1st sloping holes below the cut, and divided all the holes located below the 1st sloping holes into a certain area with longitudinal section, to lower pollution made from tunnel blasting. With the sequential blasting machine, after I first blasted holes around the cut holes by a pre-splitting method, blasted the cut area and the 1st sloping holes. The 1st and 2nd sloping holes divided areas are initiated gradually to free face upwards made by the cut. Especially, I pre-splinted contour holes previous blast the before sloping holes from the contours. The ground vibration from the earth surface just over the advance face decreased about 42.0% compare with the down blasting method under the condition of equal charge weight per delay. I controlled the crack and over break of the mother rock by pre-splitting contour holes before blast the first sloping holes from the contours. The peak values of noise and air blast by blasting decreased about 10dB more than the down blasting method. the noise and air blast diminished gradually as a round. The throw distance of the fly rock was decreased about 55%.

Foundation Research for Reinforced Concrete Substitution Grounding Electrode (철근콘크리트 대용접지극에 관한 기초 연구)

  • Kim, Sung-Sam;Lee, Chung-Sik;Koh, Hee-Seog
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.305-308
    • /
    • 2004
  • There are ground facility of maintenance in house electric facility of infra maintenance electric home appliances having used multifariousness in house, that use electric energy of common source for equipment. The body of building such as the reinforced concrete construction is structurally united, and the electric resistance is also small. It is possible that those foundations have contacted the ground at large surface area and that it substitutes the building construction body for the earth electrode. This is called "the structure earthing". This method has been defined at electrical facilities technical standards and KS in our country, and it has been used in various quarters practically. However, in our country, there is no example of using the foundation of the house as substitution earth electrode practically, and the means of the evaluation as electrode has not been established either. Then, in this paper, basic research for utilizing foundation of the house as substitution earth electrode is carried out.

  • PDF