• Title/Summary/Keyword: Ground Shock

Search Result 192, Processing Time 0.025 seconds

A Study of Environment & Bullet-Proof Capability Test Method for KLTV's Transparent Armour (한국형 전술차량 방탄유리 환경 및 방호력 시험 적용 기법 연구)

  • Park, Jinwon;Park, Youngchan;Kim, Seonjin
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.21 no.1
    • /
    • pp.69-73
    • /
    • 2018
  • Korean-peacekeeper's transparent armors in Iraq showed delamination, cracking and clouding a decade ago. And there were also similar deterioration recurrences in KLTV during the operational test a few years ago. Also, the differences between operational capability & lab Bullet-proof test condition, and insufficiency of military protection spec resulted in incomplete bullet-proof results. Moreover, although so many ground weapon systems have been developed, there were not secure test & evaluation codes to verify transparent armoured glasses equal to advanced-overseas products. So in this study, first, environmental test codes were established that all tests should be carried out as the application of only one specimen with newly adopted thermal shock test instead of completing each test with different one. Second, protection standards were integrated through the analysis of global developed country's specifications and reinforced as adding to the real mock-up condition if vehicle's glasses are smaller than standard specimen. Hereby, by applying to test-codes which including actual operational & vehicular conditions, the gap between development test and operational environment was minimized.

Development of DC Leakage Current Sensor for Solar Power Generation System (태양광발전시스템용 직류 누설전류 센서 개발)

  • Kim, Hee-Sun;Hahn, Song-Yop;Han, Hoo-Sek
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.6
    • /
    • pp.828-833
    • /
    • 2014
  • Grid connected transformerless solar power generation system is frequently used with the benefits of cost and efficiency. However, significant DC leakage current can flow from the DC line into the ground with dielectric breakdown in the transformerless solar power generation system. The leakage current occurred in the DC line causes accidents such as fire and electric shock on human. To resolve this problem, high sensitivity DC leakage current sensor is needed. But recently the studies on safety of DC line are not performed. In this paper, a high sensitivity DC leakage current sensor that can detect DC leakage current in solar power generation system, is proposed. Based on the studies, DC leakage current sensor is fabricated and characteristic tests are carried out. Finally, the accuracy of sensor performance is verified by leakage current experiments in solar power generation system.

A Study on ground fault at low voltage line and apparatus in urban railway station (도시철도역사의 저압선로 및 기기에서의 지락사고 방지 방안에 관한 검토)

  • Min Kyung-Yun;Kim Jin-Ho;Han Hag-Su
    • Proceedings of the KSR Conference
    • /
    • 2005.11a
    • /
    • pp.699-704
    • /
    • 2005
  • In the station of the railway and the subway various illumination equipment and a general power equipment for a passenger convenience, the signal equipment and the communication equipment which is necessary to the train operation provided. At the all of like this equipment from the electric room which is established in each station by changing from high voltage to low voltage and it supplies from the illumination transformer, the power transformer and the signal transformer. If it supplies to the equipment from the high voltage to the low voltage, it must be established to contact protection device in between the high voltage coil and the low voltage coil. Also it must do the grounding faulting device at the low voltage lines, the earthing devices at apparatus for the protection of an electric shock and an electric fire by the electric relation law. Compared the related regulations between the facilities which require protective functions such as grounding fault or earthing in public utilities like subway stations, and the facilities which do not require line earthing or protective functions such as electricity supplied for signalling the train. Also, will describe a countermeasure for the accident from a grounding fault.

  • PDF

AFO Changes Leg Muscle Activation During Stairs Descending

  • Choi, Jae Cheong;Han, Seul Ki
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.7 no.2
    • /
    • pp.1037-1040
    • /
    • 2016
  • This study aims to investigate the effects of ankle foot orthosis(AFO) on the activities of tibialis anterior(TA), soleus(Sol), rectus femoris(RF) and biceps femoris(BF) during stairs descending. The activities of TA, Sol, RF and BF were initially measured while descending 4 stairs without using AFO. The activities of the same muscles were then measured again while descending 4 stairs while using AFO. Wilcoxon signed-rank tests were used to analyze the results in order to examine the differences between the with using AFO and without using AFO. Although the activities of TA, Sol and RF were relatively lower while using AFO than without using AFO, only the differences in Sol and RF activities were significant(p<0.05). The activity of BF was relatively higher while using AFO compared to the activity of BF observed without using AFO. However, difference was not significant(p>0.05). Conclusion of this study was observed since AFO's ground reaction force absorption during stairs descending reduced the need to use So and RF that is related to shock absorption. BF activity was increased with AFO than without during standing forward to correct the trunk stability.

Development of an Inspection Box for a Guard Lamp with an Automatic Switch (자동점멸식 보안등 점검함 개발)

  • Jung, Jong-Wook;Jung, Jin-Soo;Kim, Sun-Gu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.10
    • /
    • pp.34-40
    • /
    • 2008
  • In this paper, a device for safety inspection of a guard lamp with an automatic switch which has been recently employed in some local autonomous entities was developed. It is technically enhanced by installing a separate inspection box down below, which allows the inspectors can measure the leakage current, the sound function of the electric leakage breaker(ELB), the insulation resistance and the grounding resistance, on the ground. This inspection box makes the inspectors free from the electric shock by being designed to minimize the potential direct contact with the energized terminals. The deliverables of this paper are expected to contribute to carry out the inspection for the guard lamps safely and effectively.

Study on Driving a Bumped Slope of Mobile Robot According to Changing the Damping Coefficient of Suspensions (이동 로봇의 서스펜션 댐핑계수 변화에 따른 장애물이 있는 경사로 주행에 관한 연구)

  • Jeon, Bongsoo;Kim, Jayoung;Lee, Jihong
    • The Journal of Korea Robotics Society
    • /
    • v.11 no.2
    • /
    • pp.83-91
    • /
    • 2016
  • Most of outdoor mobile robots have a suspension on each wheel in order to relieve the shock by ground obstacles and to improve the driving stability. Typically, in the actual operations, the suspensions have been used under a given set of conditions as all the damping and spring coefficients of the suspensions are fixed. However, it is necessary to readjust the coefficients of the suspensions according to surface conditions that may cause the unstable shaking of a robot body at high speed driving. Therefore, this paper is focused on the mobility analysis of an outdoor robot when the coefficients of suspensions (in particular, damping coefficients) are changed while driving on an uneven road surface. In this paper, a semi-active suspension with twelve damping coefficient levels was used and a small sized vehicle with the suspensions was employed to analyze the mobility dependent on a change of the damping coefficient. And the mobility was evaluated through driving experiments on a bumped slope.

A Study on the Method of Resistance Analysis of Water Stream During Fire Supperession (화재진압 시 발생하는 주수 기둥의 저항분석 방법 연구)

  • Jung, Byeong-Sun;Kim, Eung-Sik;Park, Jong-Yeol
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.6
    • /
    • pp.22-27
    • /
    • 2018
  • Fire fighters are exposed to the risk of many accidents during fire suppression, especially near the high voltage circuit. In order to prevent and analyze the electric shock accidents, measurement of water resistance is crucial. However, this has been one of the overlooked research areas and it has been very difficult to measure the mixed up resistance components separately. In this paper, we measured a total resistance of apparatus and regarded it as a serial resistance of contact resistance and length dependant resistance. Measuring the resistance by varying the length of water stream, the variable resistance and fixed contact resistance appear, which are used to calculate the both components of resistances. In addition, the resistance of fire hose can be calculated from the parallel circuit which is formed by grounding the fire hose with the resistance of water stream. Results show that we can successfully measure the resistance per unit length of water stream and fire hose, thereby proving that this method is a facile way to measure water and fire hose resistance. However, many experiments are still required to obtain the precise contact resistance of ground under various condition and the resistance between the human body and fire hose.

Biomechanical Characteristic on Lower Extremity with or without Chronic Ankle Instability during Double Leg Drop Landing (양발 드롭랜딩 시 만성적인 발목 불안정성 유무에 따른 하지주요관절의 역학적 특성)

  • Jeon, Kyoungkyu;Park, Jinhee
    • Korean Journal of Applied Biomechanics
    • /
    • v.31 no.2
    • /
    • pp.113-118
    • /
    • 2021
  • Objective: The purpose of this study was to investigate differences of landing strategy between people with or without chronic ankle instability (CAI) during double-leg drop landing. Method: 34 male adults participated in this study (CAI = 16, Normal = 18). Participants performed double-leg drop landing task on a 30 cm height and 20 cm horizontal distance away from the force plate. Lower Extremities Kinetic and Kinematic data were obtained using 8 motion capture cameras and 2 force plates and loading rate was calculated. Independent samples t-test were used to identify differences between groups. Results: Compared with normal group, CAI group exhibits significantly less hip internal rotation angle (CAI = 1.52±8.12, Normal = 10.63±8.44, p = 0.003), greater knee valgus angle (CAI = -6.78±5.03, Normal = -12.38 ±6.78, p = 0.011), greater ankle eversion moment (CAI = 0.0001±0.02, Normal = -0.03±0.05, p = 0.043), greater loading Rate (CAI = 32.65±15.52, Normal = 18.43±10.87, p = 0.003) on their affected limb during maximum vertical Ground Reaction Force moment. Conclusion: Our results demonstrated that CAI group exhibits compensatory movement to avoid ankle inversion during double-leg drop landing compared with normal group. Further study about how changed kinetic and kinematic affect shock absorption ability and injury risk in participants with CAI is needed.

The Design Method of TR Module Based GaN for Satellite (실용위성 적용을 위한 GaN 기반 TR모듈 설계 기법)

  • Yang, Ho-Jun;Lee, Yu-ri;Cho, Seongmin;Yu, Kyungdeok;Kim, Jong-Pil
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.50 no.1
    • /
    • pp.31-38
    • /
    • 2022
  • TR module using in satellite must consider discriminative electrical and mechanical requirements compare to the one using in ground and aircraft system since not only the environment level of vibration and shock during the launch stage but also the level of radiation, vacuum and thermal variation from orbit environment are more severe than atmosphere condition. This paper describes the environmental conditions of launch and the orbit and, suggests design method of TR module applying GaN to satisfy the unique environmental requirements of satellite systems by especially focusing on parts selection, derating design, RF budget design, manufacturing process design, and thermal design of TR module.

Investigation of the ASTM International frost heave testing method using a temperature-controllable cell

  • Hyunwoo, Jin;Jangguen, Lee;Byung-Hyun, Ryu
    • Geomechanics and Engineering
    • /
    • v.31 no.6
    • /
    • pp. 583-597
    • /
    • 2022
  • Frost heave can cause uneven ground uplift that may damage geo-infrastructure. To assist damage-prevention strategies, standard frost heave testing methods and frost susceptibility criteria have been established and used in various countries. ASTM International standard testing method is potentially the most useful standard, as abundant experimental data have been acquired through its use. ASTM International provides detailed recommendations, but the method is expensive and laborious because of the complex testing procedure requiring a freezing chamber. A simple frost heave testing method using a temperature-controllable cell has been proposed to overcome these difficulties, but it has not yet been established whether a temperature-controllable cell can adequately replace the ASTM International recommended apparatus. This paper reviews the applicability of the ASTM International testing method using the temperature-controllable cell. Freezing tests are compared using various soil mixtures with and without delivering blow to depress the freezing point (as recommended by ASTM International), and it is established that delivering blow does not affect heave rate, which is the key parameter in successful characterization of frost susceptibility. As the freezing temperature decreases, the duration of supercooling of pore water shortens or is eliminated; i.e., thermal shock with a sufficiently low freezing temperature can minimize or possibly eliminate supercooling.