• Title/Summary/Keyword: Ground Resistance

Search Result 1,049, Processing Time 0.028 seconds

Comparison the grounding effect of a grounding rods and a grounding copper band in the Distribution System (배전계통 접지전극의 접지효과 분석 연구)

  • Kang Moon Ho
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.509-511
    • /
    • 2004
  • Grounding rods as a discharge path are normally used to ensure the safety of human beings and facilities from the over-voltages and the over·current. Each grounding mode class 1, class 2, class 3, special class 4- has prescribed ground resistance values which are kept by the utilities. However, in the distribution system, it is very difficult for grounding rods to obtain the prescribed ground resistance values because of the limits of installation space. Therefore, in this paper, the grounding effects of the grounding copper bands which are recently developed to use efficiently in small area and the grounding rods are compared by testing the ground resistance values, ground potential rise(GPR), and step voltage in various cases.

  • PDF

Analysis of Pile Behaviors with Friction Resistance of Skin of Steel Pipe Pile in Ground where Settlement is Predicted (침하가 예측되는 지반에서 강관말뚝 주면 마찰 저항에 따른 말뚝의 거동 분석)

  • Lee, Kicheol;Shin, Sehee;Lee, Haklin;Kim, Dongwook
    • Journal of the Korean Geotechnical Society
    • /
    • v.36 no.11
    • /
    • pp.107-117
    • /
    • 2020
  • Open-ended steel pipe piles have outside frictional force and inside frictional resistance in which blocked soil acts on the inside of the steel pipe during installation. It is expected that the ultimate load will change depending on the inside and outside resistance. And, if the ground on which the piles were constructed is clay soil, it is predicted that it will have effect on the negative skin friction caused by the ground settlement. Therefore, in this study, the behavior according to the inside and outside resistance characteristics of steel pipe piles was analyzed numerically, and the frictional force distribution, axial load and settlements before and after the occurrence of ground settlement were calculated. As a result of the analysis, the inside frictional resistance had less influence than the outside frictional resistance. However, inside frictional resistance is considered to be one of the important factors considering the effect on the overall pile behavior, and both resistance factors need to be considered in the design process.

Grounding Resistance and Current Characteristics of the Planar Earth Structure using Multiple Discharge Paths (다중방전 경로를 이용한 편상접지체의 접지저항 및 전류특성)

  • Kim, Young-Sun;Kim, Dong-Min;Lee, Ki-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.9
    • /
    • pp.1564-1570
    • /
    • 2016
  • This study proposes a newly modified form of existing ground electrodes in order to secure trust of grounding system for large current caused by a stroke of lightning. Proposed planar earth structure has a several needle electrodes around a circular rod and 4 plane electrodes in all directions. The plane electrodes are fused with the insulator on the linear rod, so that they're electrically isolated. The concept is to increase the discharge amount of earth structure using multiple discharge paths like needle and plane electrodes. To check the discharge efficiency of the suggested scheme, the discharge currents are compared with typically used two kinds of ground rods. To ensure accuracy in the measurement of the discharge current, the same material was used for the comparison model. Also, the ground resistance are simulated by CDEGS commercial software and the results are compared with measured data. Based on this kind of experimental study, the suggested ground rod can be used when designing a ground system or when constructing a ground system at the site.

Improvements of Grounding Performances Associated with Soil Ionization under Impulse Voltages (임펄스전압에 의한 토양의 이온화에 따른 접지성능의 향상)

  • Kim, Hoe-Gu;Lee, Bok-Hee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.12
    • /
    • pp.1971-1978
    • /
    • 2016
  • In this paper, electrical and physical characteristics associated with the ionization growth of soil under impulse voltages in a coaxial cylindrical electrode system to simulate a horizontally-buried ground electrode were experimentally investigated. The results were summarized as follows: Transient ground resistances decreased significantly by soil ionization. The voltage-current (V-I) curves for non-ionization in soil lined up in a straight line with the nearly same slope that is the ground resistance, but they showed a 'cross-closed loop' of ${\infty}$-shape under ionization. The conventional ground resistance and equivalent soil resistivity were inversely proportional to the peak value of injected impulse currents. On the other hand, the equivalent ionization radius and time-lag to the maximum value of ionization radius were increased with increasing the incident impulse voltages. An analysis method for the transient ground resistances of the ground electrode based on the ionization phenomena was proposed. The proposed method can be applied to analyze the transient performances of grounding systems for lightning protection in power system installations.

An Experimental Study on the Frost Resistance of High-Flowing Concrete Using Granulated Blast-Furnace Slag (고로슬래그 미분말을 사용한 고유동콘크리트의 내동해성에 관한 실험적 연구)

  • 김무한;권영진;강석표
    • Journal of the Korea Concrete Institute
    • /
    • v.12 no.2
    • /
    • pp.43-51
    • /
    • 2000
  • This study is to investigate for the frost resistance of high-flowing concrete using finely ground granulated blast-furnace slag with experimental parameters, such as type of binder, type of superplasticizer and method of curing. The resistance to freezing and thawing of high-flowing concrete by type of binder and superplasticizer is presented differently. Though the frost resistance of high-flowing concrete is satisfactory under standard condition, it is required that high-flowing concrete has entrained air like plain concrete. Because the critical spacing factor, being capacity of frost resistance, of high-flowing concrete is longer that of plain concrete, the frost resistance of high-flowing concrete, using finely ground granulated furnace blast slag, is superior to that of plain concrete.

An Experimental Study on the Effect of Ground Heat Exchanger to the Overall Thermal Conductivity (지중열교환기 설치 조건이 지중 유효 열전도도에 미치는 영향에 관한 실험적 연구)

  • Kong, Hyoung-Jin;Lim, Hyo-Jae;Choi, Jae-Ho;Sohn, Byong-Hu
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.45-51
    • /
    • 2009
  • A ground-loop heat exchanger in a ground source heat pump system is an important unit that determines the thermal performance of a system and its initial cost. The size and performance of this heat exchanger is highly dependent on ground thermal properties. A proper design requires certain site-specific parameters, most importantly the ground effective thermal conductivity, the borehole thermal resistance and the undisturbed ground temperature. This study was performed to investigate the effect of some parameters such as borehole lengths, various grouting materials and U-tube configurations on ground effective thermal conductivity. In this study, thermal response tests were conducted using a testing device with 9-different ground-loop heat exchangers. From the experimental results, the length of ground-loop heat exchanger affects to the effective thermal conductivity. Among the various grouting materials, the bentonite-based grout with silica sand shows the largest thermal conductivity value.

  • PDF

A Study on the Applicability of Slag as Compaction Pile Material (다짐말뚝 채움재로서 슬래그의 적용성 연구)

  • 이미혜;이상익;박용원
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.03b
    • /
    • pp.207-214
    • /
    • 2000
  • Sand Compaction Pile method is one of the widely used ground improvement techniques at loose sand or soft clay ground in Asian countries. However, due to environmental and economical problems concerning shortage of sand resources alternative materials are needed to substitute sand for SCP. This study is on the applicability of slag as an alternative material SCP. Consolidation and direct shear test are performed for the slag-clay composite specimens to find out the positive effects of consolidation rate and shear resistance of slag reinforced ground. The result shows that slag has similar effects with sand in consolidation and shear resistance behavior in composite ground, which says slag can be used as alternative material of sand for SCP.

  • PDF

Thermal Conductivity Estimate of Ground Using Energy Piles (PHC 에너지 파일을 이용한 지반의 열전도도 산정)

  • Yoon, Seok;Go, Gyu-Hyun;Park, Hyun-Ku;Park, Skhan;Lee, Seung-Rae;Cho, Kyung-Jin;Song, Chi-Yong
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.8 no.4
    • /
    • pp.8-16
    • /
    • 2012
  • The use of energy pile foundation has been increased for economic utilization of geothermal energy. This paper describes an experimental and numerical study on thermal response tests (TRTs) using W and 3U-shaped ground heat exchangers (GHEs) in precast-high strength concrete (PHC) energy piles. Ground thermal conductivity and borehole thermal resistance were measured and compared with those numerical analysis. W-shpaed GHE showed higher heat transfer behavior than 3U-shaped one because of different conditions such as pile size and volume of grout. That is, ground thermal conductivity using W-shaped GHE was higher than that of 3U shaped GHE, and borehole thermal resistance vice versa. The relative error of borehole resistance values between numerical and analytical solution was less than 5%.

Design and Fabrication of a Wideband Ground Impedance Meter (광대역 접지임피던스 측정기의 설계 및 제작)

  • Kil, Gyung-Suk;Park, Dae-Won;Jang, Un-Yong;Han, Ju-Seop;Gil, Hyoung-Jun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.10
    • /
    • pp.793-797
    • /
    • 2010
  • The basic performance of the ground system is evaluated as the ground resistance by applying low frequency current below 1 kHz. However, characteristics of the ground system should be analyzed by high frequency current up to 1 MHz since transient currents having a few hundred kHz component flow during a line-to-ground fault and/or a lightning strike. This paper deals with the design and fabrication of a wideband ground impedance meter (WGIM) which measures the impedance of ground systems in ranges from 65 Hz to 1.28 MHz. Also, a noise elimination algorithm using a digital bandpass filter is proposed. The maximum error of the WGIM is 4.91% in the measurement frequency range.

A Study on Smart Ground Resistance Measurement Technology Based on Aduino (아두이노 기반 IT융합 스마트 대지저항 측정 기술 연구)

  • Kim, Hong Yong
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.4
    • /
    • pp.684-693
    • /
    • 2021
  • Purpose: The purpose is to establish a safe facility environment from abnormal voltages such as lightning by developing a smart land resistance measuring device that can acquire real-time land resistance data using Arduino. Method: This paper studied design models and application cases by developing a land resistance acquisition and analysis system with Arduino and a power line communication (PLC) system. Some sites in the wind power generation complex in Gyeongsangnam-do were selected as test beds, and real-time land resistance data applied with new technologies were obtained. The electrode arrangement adopted a smart electrode arrangement using a combination of a Wenner four electrode arrangement and a Schlumberger electrode arrangement. Result: First, the characteristic of this technology is that the depth of smart multi-electrodes is organized differently to reduce the error range of the acquired data even in the stratigraphic structure with specificity between floors. Second, IT convergence technology was applied to enable real-time transmission and reception of information on land resistance data acquired from smart ground electrodes through the Internet of Things. Finally, it is possible to establish a regular management system and analyze big data accumulated in the server to check the trend of changes in various elements, and to model the optimal ground algorithm and ground system design for the IT convergence environment. Conclusion: This technology will reduce surge damage caused by lightning on urban infrastructure underlying the 4th industrial era and design an optimized ground system model to protect the safety and life of users. It is also expected to secure intellectual property rights of pure domestic technology to create jobs and revitalize our industry, which has been stagnant as a pandemic in the post-COVID-19 era.