• Title/Summary/Keyword: Ground Resistance

Search Result 1,049, Processing Time 0.028 seconds

A Brief Review of Backgrounds behind "Multi-Purpose Performance Halls" in South Korea (우리나라 다목적 공연장의 탄생배경에 관한 소고)

  • Kim, Kyoung-A
    • (The) Research of the performance art and culture
    • /
    • no.41
    • /
    • pp.5-38
    • /
    • 2020
  • The current state of performance halls in South Korea is closely related to the performance art and culture of the nation as the culture of putting on and enjoying a performance is deeply rooted in public culture and arts halls representing each area at the local government level. Today, public culture and arts halls have multiple management purposes, and the subjects of their management are in the public domain including the central and local governments or investment and donation foundations in overwhelming cases. Public culture and arts halls thus have close correlations with the institutional aspect of cultural policies as the objects of culture and art policies at the central and local government level. The full-blown era of public culture and arts halls opened up in the 1980s~1990s, during which multi-purpose performance halls of a similar structure became universal around the nation. Public culture and arts halls of the uniform shape were distributed around the nation with no premise of genre characteristics or local environments for arts, and this was attributed to the cultural policies of the military regime. The Park Chung-hee regime proclaimed Yusin that was beyond the Constitution and enacted the Culture and Arts Promotion Act(September, 1972), which was the first culture and arts act in the nation. Based on the act, a five-year plan for the promotion of culture and arts(1973) was made and led to the construction of cultural facilities. "Public culture and arts" halls or "culture" halls were built to serve multiple purposes around the nation because the Culture and Arts Promotion Act, which is called the starting point of the nation's legal system for culture and arts, defined "culture and arts" as "matters regarding literature, art, music, entertainment, and publications." The definition became a ground for the current "multi-purpose" concept. The organization of Ministry of Culture and Public Information set up a culture and administration system to state its supervision of "culture and arts" and distinguish popular culture from the promotion of arts. During the period, former President Park exhibited his perception of "culture=arts=culture and arts" in his speeches. Arts belonged to the category of culture, but it was considered as "culture and arts." There was no department devoted to arts policies when the act was enacted with a broad scope of culture accepted. This ambiguity worked as a mechanism to mobilize arts in ideological utilizations as a policy. Against this backdrop, the Sejong Center for the Performing Arts, a multi-purpose performance hall, was established in 1978 based on the Culture and Arts Promotion Act under the supervision of Ministry of Culture and Public Information. There were, however, conflicts of value over the issue of accepting the popular music among the "culture and arts = multiple purposes" of the system, "culture ≠ arts" of the cultural organization that pushed forward its establishment, and "culture and arts = arts" perceived by the powerful class. The new military regime seized power after Coup d'état of December 12, 1979 and failed at its culture policy of bringing the resistance force within the system. It tried to differentiate itself from the Park regime by converting the perception into "expansion of opportunities for the people to enjoy culture" to gain people's supports both from the side of resistance and that of support. For the Chun Doo-hwan regime, differentiating itself from the previous regime was to secure legitimacy. Expansion of opportunities to enjoy culture was pushed forward at the level of national distribution. This approach thus failed to settle down as a long-term policy of arts development, and the military regime tried to secure its legitimacy through the symbolism of hardware. During the period, the institutional ground for public culture and arts halls was based on the definition of "culture and arts" in the Culture and Arts Promotion Act enacted under the Yusin system of the Park regime. The "multi-purpose" concept, which was the management goal of public performance halls, was born based on this. In this context of the times, proscenium performance halls of a similar structure and public culture and arts halls with a similar management goal were established around the nation, leading to today's performance art and culture in the nation.

An Experimental Study on Pullout Behavior of Shallow Bearing Plate Anchor (얕은 지압형 앵커의 인발거동특성에 관한 실험적 연구)

  • Hong, Seok-Woo;Kim, Hyung-Kong
    • Journal of the Korean Geotechnical Society
    • /
    • v.30 no.2
    • /
    • pp.5-18
    • /
    • 2014
  • Depending on the underground load support mechanism, anchors are classified as friction anchors, bearing plate anchors and the recently developed combined friction-bearing plate anchors which combine the characteristics of both the friction and bearing plate type anchors. Even though numerous studies have been performed on bearing plate anchors, there were only few studies performed to observe the failure surface of bearing plate anchors. Furthermore most of the soil materials used on these tests were not real sand but carbon rods. In this study, sand was placed in the soil tank and laboratory tests were performed with bearing plate anchors installed with an embedment depth (H/h) ranging from 1~6. The variation in the pullout capacity and the behaviour of soil with the embedment depth (H/h) were observed. Ground deformation analysis program was also used to analyze soil displacement, zero extension direction, maximum shear strain contours. It was determined from the analysis of the results that at ultimate pullout resistance the deformation was 5 mm and the failure surface occurred in a narrower area when compared with results of the previous researches. It was also observed that the width of the fracture surface gradually becomes wider and expands up to the surface as the deformation increases from 10 mm to 15 mm.

Engineering Properties of Mylonite in the Youngju Area (영주지역 압쇄암의 공학적 특성 연구)

  • Kim, Sung-Wook;Choi, Eun-Kyeong;Yang, Tae-Sun;Lee, Kyu-Hwan
    • Journal of the Korean Geotechnical Society
    • /
    • v.27 no.10
    • /
    • pp.35-43
    • /
    • 2011
  • The area to be studied is the place where the main line rail way will be constructed in accordance with the scheduled construction project of Yeongju dam, and is a fold and mylonite zone over several km that is formed by ductile-shearing effect. The ductile shear zone, which has been transformed by faulting for long geological time, shows a complicated geological structure. Due to the recrystallization of mineral caused by transformation in deep underground (>8km), a mylonite zone with lamellar structure has properties distinguished from other fault zones formed by transformation near earth surface <2km). To see the properties of mylonite, this study analyzed the transformation rate of sample rocks and the shape of constriction structure accompanied with transformation. While the transformation of fault zone shows a round oblate, the mylonite zone shows a prolate form. Transformation rate in fault zone was measured to be less than 1.2 compared to the state before transformation while the measured rate in mylonite zone was 2.5 at most. Setting the surface of discontinuity as the base, the unconfined compressive strength of slickenside can be categorized in sedimentary rocks, and a change of strength was observed after water soaking over certain time. Taking into account that the weathering resistance of the rock based on mineral and chemical organization is relatively higher, its engineering properties seems to result from the shattered crack structure by crushing effect. When undertaking tunnel construction in mylonite zone, there should be a special care for the expansion of shattered cracks or the fall of strength by influx of ground water.

Studies of the Life Cycle and Rearing Methods of Whitebacked Planthopper (Sogatella furcifera Horváth) (흰등멸구의 생활환 및 사육방법 연구)

  • Kim, Kyung-Min;Park, Young-hie
    • Journal of Life Science
    • /
    • v.28 no.3
    • /
    • pp.357-360
    • /
    • 2018
  • This study developed a method to minimize rice damages and enhance timely control by accurately classifying Whitebacked Planthopper (WBPH). The body size of the 1st-3rd instar was 1.5-2 mm, and the body size of the 4-5 instar was 2.5-3.5 mm. In the third instar, the ratio of the front wing bud and the back wing-bud was 1:1. The fourth instar occupied 3/4 of the front wing-bud, and the 5th instar showed that the front wing-bud covers the back wing-bud. It was confirmed that the 1st instar does not have a sensory plate, the 2nd instar has 2-3, the 3rd instar has 4-5, the 4th instar has 6-9, the 5th instar has 10-15, and the adult instar has 15-20 sensory plates. The female spawning organs were reddish when the spawning horn was inserted. WBPH showed that the larvae of 2-3 larvae most actively feed on rice, and the damaged area was the stem of rice near the ground. In addition, a partial black wound was observed after the feeding. WBPH-susceptible 'Chucheong' was yellowish, and early growth was slower than that of 'Cheongcheong', which was resistant; moreover, a difference between susceptibility and resistance was observed. The identification of the number of such wounds in the bioassay will be a better basis for understanding the difference in susceptibility between WBPH strains and cultivars. These results will be used as basic data for cultivating the WBPH-resistant varieties of rice.

A numerical study of the effects of the ventilation velocity on the thermal characteristics in underground utility tunnel (지하공동구 터널내 풍속 변화에 따른 열특성에 관한 수치 해석적 연구)

  • Yoo, Ji-Oh;Kim, Jin-Su;Ra, Kwang-Hoon
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.1
    • /
    • pp.29-39
    • /
    • 2017
  • In this research, thermal design data such as heat transfer coefficient on the wall surface required for ventilation system design which is to prevent the temperature rise in the underground utility tunnel that three sides are adjoined with the ground was investigated in numerical analalysis. The numerical model has been devised including the tunnel lining of the underground utility tunnel in order to take account for the heat transfer in the tunnel walls. The air temperature in the tunnel, wall temperature, and the heating value through the wall based on heating value(117~468 kW/km) of the power cable installed in the tunnel and the wind speed in the tunnel(0.5~4.0 m/s) were calculated by CFD simulation. In addition, the wall heat transfer coefficient was computed from the results analysis, and the limit distance used to keep the air temperature in the tunnel stable was examined through the research. The convective heat transfer coefficient at the wall surface shows unstable pattern at the inlet area. However, it converges to a constant value beyond approximately 100 meter. The tunnel wall heat transfer coefficient is $3.1{\sim}9.16W/m^2^{\circ}C$ depending on the wind speed, and following is the dimensionless number:$Nu=1.081Re^{0.4927}({\mu}/{\mu}_w)^{0.14}$. This study has suggested the prediction model of temperature in the tunnel based on the thermal resistance analysis technique, and it is appraised that deviation can be used in the range of 3% estimation.

Growth Characteristics and Yield Potentials of Soybeans in Upland and Paddy Field (전과 답에서의 콩 생육특성과 수량성)

  • 황영현;박상구
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.38 no.4
    • /
    • pp.336-342
    • /
    • 1993
  • To obtain the basic information necessary for the development of soybean varieties well adaptable to upland-paddy field rotational croppings, the difference of growth characteristics between upland and paddy-field including yield potentials of current recommending soybean varieties were evaluated. The growth characteristics, both above and under-ground, which were measured at flowering stage were generally greater in paddy-field but the number of root nodules was much greater in upland, thus the artificial inoculation was practically recommended for soybean growing in paddy-fields. Mean seed yield was generally higher in paddy-fields than in upland. All soybean varieties showed higher seed yield in the early planting date, April 20, were somewhat susceptible to soybean mosaic virus(SMV), thus they could be escaped from the disasterous endemic necrotic soybean mosaic virus(SMV-N). Soybean varieties showed over 4.0 tons/ha seed yield in the paddy-field were Williams 79, Union, SS77053, and Namhaekong. At the same time, Jangyeobkong and Danyeobkong were the most stable soybean varieties among the tested soybean varieties with less than 10% of coefficient variation values in all planting dates in paddy fields. Compared with Hwangkeumkong which is most widely being cultivated on farmer's fields, soybean varieties showed high yields in paddy-field were higher in plant height, less in the number of branches, and more in the number of nodes on main stem. At the same time, they had medium seed size which would bring the good germination and stands. Disease resistance especially for necrotic soybean mosaic virus was also one of the most decisive factors in seed yields for the early planted soybeans.

  • PDF

Application of EPS Considering Long-term Durability (장기내구성을 고려한 EPS의 현장 적용성)

  • Chun, Byungsik;Jung, Changhee;Ahn, Jinhyun
    • Journal of the Korean GEO-environmental Society
    • /
    • v.8 no.6
    • /
    • pp.53-60
    • /
    • 2007
  • L/EPS, manufactured in the shape of block and used for civil engineering, is a lightweight material with an excellent resistance to compression, and provides a superb self-sufficient stability. EPS is a suitable material capable of resolving the problem of settlement and lateral flow if it is applied as the soil on soft ground. The Korean Standards (KS) has not yet proposed any testing method for use of EPS as an engineering banking material. Only its testing and quality ordinance as a heat insulation material has been standardized. The design criteria for EPS has been established and applied through the trial construction of KHC (Korea Highway Corporation) and quality test of manufacturer, but most studies on them have been confined to factory products. This study is focused on comparing and analyzing long-term durability by conducting cyclic load test, freezing and thawing test, absorption rate test and others. EPS used in the test was chosen from construction sites and factory products, focusing on the long-term durability of EPS depending on the passage of time. Unconfined compression test results indicated that the strength of collected samples was lower than factory products. While the triaxial compression test results indicated that the shear strength increased in proportion to the increase of confining pressure, and factory products had declining shear strength as the confining pressure rose.

  • PDF

Derivation of Optimum GGBFS Replacement with Durability Design Parameters (내구성 설계 변수에 따른 최적 고로슬래그 미분말의 치환율 도출)

  • Jang, Seung-Yup;Yoon, Yong-Sik;Kwon, Seung-Jun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.6 no.1
    • /
    • pp.36-42
    • /
    • 2018
  • GGBFS(Ground Granulated Blast Furnace Slag)-replacement is very effective for improving resistance to chloride attack and this can induce a long service life for RC(Reinforced Concrete) structures exposed to chlorides. In the work, the design parameters such as cover depth, surface chloride content, critical chloride content, and replacement ratio of GGBFS are considered, and optimum replacement ratio of GGBFS are derived with intended service life. The changes of surface chloride content and cover depth show 3.16~3.38 and 3.02~3.34 times of service life variation, which are most influencing parameters. Critical chloride content shows 1.53~1.57 times of service life variation regardless of w/b(Water to Binder) ratios. In the case of surface chloride content $18.0kg/m^3$, the most severe condition, cover depth over 70 mm and GGBFS replacement ratio over 42% are required with concrete containing w/b ratio under 0.42 for 100 years of intended service life. The condition of $13.0kg/m^3$, GGBFS replacement over 35% is required. For reasonable durability design, quantitative exterior condition and critical chloride content should be determined, and the criteria in Domestic Specification is evaluated to be conservative.

Application of DC Resistivity Survey from Upper Portion of Concrete and Geostatistical Integrated Analysis (콘크리트 상부에서 전기비저항 탐사 적용 및 지구통계학적 복합 해석)

  • Lee, Heuisoon;Oh, Seokhoon;Chung, Hojoon;Noh, Myounggun;Ji, Yoonsoo;Ahn, Taegyu;Song, Sung-Ho;Yong, Hwan-Ho
    • Journal of the Korean earth science society
    • /
    • v.35 no.1
    • /
    • pp.29-40
    • /
    • 2014
  • A DC resistivity survey was performed to detect anomalies beneath concrete pavement. A set of high conductive media and planar electrodes were used to lessen the effect's a high contact resistance of concrete. Results of the resistivity survey were analyzed and compared with those of other geophysical surveys such as Ground Penetration Radar (GPR), Impulse Response (IR), and Multi-channel Analysis of Surface Waves (MASW), which were carried out in the same location. The results of resistivity survey showed a high resistive distribution in the section of sink and pavement where a pattern of reinforcement was observed through the GPR survey. Also, a comparison of results between the IR and resistivity surveys indicated that the high resistivity was produced by the high dynamic stiffness in the reinforced section. The co-Kriging of both the results of DC resistivity and MASW surveys at the same location showed that an integrated geostatistical analysis is able to give more accurate description on the anomalous subsurface region than can a separate analysis of each geophysical approach. This study suggests that the integrated geostatistical approaches were used for a decision-making process based on the geophysical surveys.

Study on the Damage Pattern Analysis of a 3 Phase 22.9/3.3kV Oil Immersed Transformer and Judgment of the Cause of Its Ignition (3상 22.9/3.3kV 유입변압기의 소손패턴 해석 및 발화원인 판정에 관한 연구)

  • Choi, Chung-Seog
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.6
    • /
    • pp.1274-1279
    • /
    • 2011
  • The purpose of this paper is to present the manufacturing defect and damage pattern of a 3 phase 22.9/3.3kV oil immersed transformer, as well as to present an objective basis for the prevention of a similar accident and to secure data for the settlement of PL related disputes. It was found that in order to prevent the occurrence of accidents to transformers, insulating oil analysis, thermal image measurement, and corona discharge diagnosis, etc., were performed by establishing relevant regulation. The result of analysis performed on the external appearance of a transformer to which an accident occurred, the internal insulation resistance and protection system, etc., showed that most of the analysis items were judged to be acceptable. However, it was found that the insulation characteristics between the primary winding and the enclosure, those between the ground and the secondary winding, and those between the primary and secondary windings were inappropriate due to an insulating oil leak caused by damage to the pressure relief valve. From the analysis of the acidity values measured over the past 5 years, it is thought that an increase in carbon dioxide (CO2) caused an increase in the temperature inside the transformer and the increase in the ethylene gas increased the possibility of ignition. Even though 17 years have passed since the transformer was installed, it was found that the system's design, manufacture, maintenance and management have been performed well and the insulating paper was in good condition, and that there was no trace of public access or vandalism. However, in the case of transformers to which accidents have occurred, a melted area between the upper and the intermediate bobbins of the W-phase secondary winding as well as between its intermediate and lower bobbins. It can be seen that a V-pattern was formed at the carbonized area of the transformer and that the depth of the carbonization is deeper at the upper side than the lower side. In addition, it was found that physical bending and deformation occurred inside the secondary winding due to non-uniform pressure while performing transformer winding work. Therefore, since it is obvious that the accident occurred due to a manufacturing defect (winding work defect), it is thought that the manufacturer of the transformer is responsible for the accident and that it is lawful for the manufacture to investigate and prove the concrete cause of the accident according to the Product Liability Law (PLL).