• Title/Summary/Keyword: Ground Magazine

Search Result 241, Processing Time 0.02 seconds

Water Balance on Paddy Fields in Jedae Cheon Basin (제대천 유역 답지대의 물수지)

  • 안세영;이근후
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.32 no.3
    • /
    • pp.56-66
    • /
    • 1990
  • To investigate the status of irrigation water use and the degree of repeated use of irrigation water, observations for water balance analysis were made during the irrigation periods in 1986 and 1987 crop year. The total area of studied site is 1,441 ha. The site is a major portion of Jedaecheon basin which is located in Bubuk-myeon, Miryang-gun, Gyeongnam Province. The studied area was subdivided into six small blocks. The water balance analysis for these subdivided blocks were carried out considering characteristics of each block. Obtained results are as follow: 1.In mountainous sloppy paddy area(less than 7% slope), the surface inflow was 5A mm/day in average that is one third of the surface inflow into plain paddy area ; 16.7 mm/day. 2.The surface inflows at the vegetative stage and the ripening stage were 15.5 mm/day and 10.4 mm/day, respectively. Those figures were larger than the actual consumptive use at respective same stages ; 13.3 mm/day and 9.2 mm/day, respectively. Whereas, the surface inflow at generative stage was 12.5 mm/day which was less than 14.0 mm/day ; the actual consumptive use. 3.The range of the variation of water storage term was 1 mm/day. This means that there were no change in depth of ponded water on paddy fields. The relationship between the variation of water storage(AS) and the variation of ground water table(H) could be expressed as follow: : AS=0.14H+0.26 4.The ground water inflow: into the transition region ; paddy fields which are located continuously from the mountainous area to the plain area, was larger than the out flow from this region, in general. Rowever, in the plain region where the ground water utilization was predominant, the ground water outflow from this region was larger than inflow: to this region. The relationship between the ground water flow(G2- G1) and the consumptive use in large paddy area(D1-D2) could be expressed as follow: (G2-G1) =0.95(D1-D2) -3.79

  • PDF

A Study on the Determination Method of Pumpin Rates in Tube Wells for Irrigation (관개용 관정의 가채빙량 추정에 관한 연구)

  • 구자웅;류한열
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.18 no.4
    • /
    • pp.4209-4217
    • /
    • 1976
  • The purpose of this thesis is to search for the determination method of pumping rates in the existing tube wells for irrigation. Pumping tests were carried out for the twelve test tube wells which were selected in the provinces of Kyounggi, Kangwon, Chungbuk and Chungnam. The depths, static water levels, pumping levels, drawdowns and yields of tube wells were measured in the pumping tests, and a centrifugal pump with 3 inches diameter, a 5 HP motor and a 90$^{\circ}$ V-notch were used in the pumping tests. The average coefficient of transmissibility calculated by Chow's and Jacob's methods is 0.0336 square meter per second, and the average pumping rate calculated by Thiem's, Smreker's, Brinkhaus' and Theis' formulae, is 919 cubic meter per day, Therefore, the ground water storage in the test areas is comparatively abundant. Correlation between pumping rates and depths of tube wells is not in existence. Also, correlation between pumping rates and the thickness of aquifer is not found in this experiment. This shows that the depths of some tube wells are deep and their thicknesses of aquifer are thick, but their ground water storages are poor, and that the depths of some tube wells are shallow and their thicknesses of aquifer are thin, but their ground water storages are abundant. It seems that the test tube wells are influenced by the peculiar characteristics that the ground water in the test areas is free ground water in alluvium layer closely related with surface water. As drawdown increases, pumping rate decreases, and as the coefficient of transmissibility increases, pumping rate also increases. Namely, there are negative correlation between pumping rate and drawdown, and positive correlation between pumping rate and the coefficient of transmissibility. Judging from the results of the pumping tests in these tests areas, the pumping rate calculated by the formula, {{{{ { Q}_{m } =Q { ( { { S}_{ m} } over { TRIANGLE S } )}^{ { 2} over {3 } } }}}} used traditionally, is likely to be higher than real pumping rates. The formula, {{{{ { Q}_{m } =Q { { H}^{ 2} } over { (2H- TRIANGLE S) TRIANGLE S} }}}} derived from Thiem's theory, is looked upon as the reasonable one to detemine pumping rates in the existing tube wells for irrigation.

  • PDF

An analysis of ground supported farm silo with variable thickness (I) -Part I mechanical characteristics of shell with Variable thickness- (지반과 구조물사이의 상호작용을 고려한 변단면 도통형쉘의 해석 (I) -변단면 쉘의 역학적 특성 (I)-)

  • 조진구;조현영
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.31 no.4
    • /
    • pp.58-71
    • /
    • 1989
  • This study aims to develop a computerized program for analysis of the ground-supported cylindrical shell structure with step varied section and to find out its mechanical characteri- stics through application of the developed program to the analysis of a ensiled farm silo as a model structure. The thickness of wall and bottom-plate of farm silo is assumed to be step-varied and its detailed structural dimensions are presented in Tab. 1 and 2. Several numerical case studies show that sectional stresses of the sample structures are largely reduced by adopting "varied section" design technique. And, other major results ob- tained from this study are summarize4 as follows ; 1. The variation of wall-thickness has a great influence on bending stresses of wall. Ho- wever, the larger the relative thickness of bottom-plate is, the smaller the influence is. 2. The magnitude of thickness of projecting toe of bottom-plate has negligible effect on sectional stresses 3. The conventional design methodology, which assumes the bottom edge of wall as clam- ped on ground, is proved to be discarded through the numerical analysis. 4. It is found that the "varied section" design technique should get similar effects as in the case of thick bott6m-plate having uniform thickness. 5. The variation of wall-thickness has a considerable effect on the bending stresses of bo- ttom-plate. Especially, this phenomenon is very remarkable in its projecting toe. In some cases. the negative bending moment may be acted on.

  • PDF

A Study on the Method of Design of Drainage in Soft Clay (연약지반의 배수설계 기법에 관한 연구)

  • 지인택
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.39 no.3
    • /
    • pp.128-137
    • /
    • 1997
  • In this study, examined influence of consolidation effect that had affected by location of pump inlet that was set collection well for drainage of pore water discharged by embankment on soft ground through the field test. The results of this study are summarized as follows; 1 Initial consolidation curve value were larger than theoritic value, the cause of these phenomena were thought influence of secondary consolidation and three dimensional strain of soft clay. 2. The settlement value of Hosino method was larger than that of Hyperbolic method, but settlement value of Hyperbolic method was accurate more than that of Hosino method in the prediction of settlement. 3. When pump inlet in collection well came down from GL+O.3m to GL-1.5m, settlement value increased about 10cm and when the ground water level was made insitu after pumping had completed , settlement was expanded about 7~8cm. So it is found that location change of pump inlet bad an influence on settlement remarkably. 4. If location of pump inlet in collection well for large scale estate or wide road site is lowered than original ground level, the settlement will be accelerated effectively, and at this stage automatic pump must be used in pumping.

  • PDF

Development of Nutrient Solution Cooling System in Hydroponic Greenhouse (수경재배 온실의 양액냉각시스템 개발)

  • 남상운;김문기
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.36 no.3
    • /
    • pp.113-121
    • /
    • 1994
  • Since it is difficult to expect the normal production of plants in greenhouses during hot summer season in Korea, certain provisions on the control of extreme environmental factors in summer should be considered for the year-round cultivation in greenhouses. This study was carried out to find a method to suppress the temperature rising of nutrient solution by cooling, which is able to contribute to the improvement of the plant growth environment in hydroponic greenhouse during hot summer season. A mechanical cooling system using the counter flow type with double pipe was developed for cooling the nutrient solution efficiently. Also the heat transfer characteristics of the system was analysed experimentally and theoretically, and compared with the existing cooling systems of nutrient solution. The cooling capacities of three different Systems, which used polyethylene tube in solution tank, stainless tube in solution tank, and the counter flow type with double pipe, were evaluated. The performance of each cooling system was about 41 %, 70% and 81 % of design cooling load in hydroponic greenhouse of 1 ,000m$^2$ on the conditions that the flow rate of ground water was 2m$^3$/hr and the temperature difference between two liquids was 10 ˚C According to the results analysed as above, the cooling system was found to have a satisfactory cooling capability for regions where ground water supply is available. Fer the other regions where ground water supply is restricted, more efficient cooling System should be developed.

  • PDF