• 제목/요약/키워드: Ground Length

검색결과 1,141건 처리시간 0.024초

지중열교환기 설치 조건이 지중 유효 열전도도에 미치는 영향에 관한 실험적 연구 (An Experimental Study on the Effect of Ground Heat Exchanger to the Overall Thermal Conductivity)

  • 공형진;임효재;최재호;손병후
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.45-51
    • /
    • 2009
  • A ground-loop heat exchanger in a ground source heat pump system is an important unit that determines the thermal performance of a system and its initial cost. The size and performance of this heat exchanger is highly dependent on ground thermal properties. A proper design requires certain site-specific parameters, most importantly the ground effective thermal conductivity, the borehole thermal resistance and the undisturbed ground temperature. This study was performed to investigate the effect of some parameters such as borehole lengths, various grouting materials and U-tube configurations on ground effective thermal conductivity. In this study, thermal response tests were conducted using a testing device with 9-different ground-loop heat exchangers. From the experimental results, the length of ground-loop heat exchanger affects to the effective thermal conductivity. Among the various grouting materials, the bentonite-based grout with silica sand shows the largest thermal conductivity value.

  • PDF

접지임피던스에 대한 접지봉 크기의 영향 분석 (The Analysis for the grounding impedance influenced by the ground rod's dimension)

  • 이복희;조정현;신희경;이강수;황등과;김정철
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 추계학술대회 논문집
    • /
    • pp.333-336
    • /
    • 2008
  • This paper resents a theoretical analysis for the grounding impedance influenced by the ground rod's dimension using the distributed parameter model. In this paper, EMTP and Matlab Program were used to simulate the distributed parameter model and to analyze the frequency-dependent characteristics of the ground rods. We compared two kinds of ground rods having different dimensions and the frequency-dependent characteristics of two ground rods were quite different from each other. It is estimated that these different characteristics are caused by the distributed parmeters which are changed by the length of ground rod.

  • PDF

전방향 거리 센서의 균일 원호길이 샘플링을 이용한 무인 이동차량의 실시간 위치 추정 (Real-time Localization of An UGV based on Uniform Arc Length Sampling of A 360 Degree Range Sensor)

  • 박순용;최성인
    • 전자공학회논문지CI
    • /
    • 제48권6호
    • /
    • pp.114-122
    • /
    • 2011
  • 본 논문에서는 무인 지상 차량의 (Unmanned Ground Vehicle, UGV)의 위치 추정을 위한 컴퓨터 비전 기술을 제안한다. 제안하는 방법은 연속적으로 획득되는 360도 거리 정보(range data)와 디지털 수치모델(Digital Surface Model, 이하 DSM)의 3차원 등록(3-D registration) 방법에 기반하고 있다. 많은 수의 3차원 점군(point clouds) 정보를 가지고 있는 거리 정보의 연속적 3차원 등록은 상당한 수행 시간을 필요로 한다. 실시간 위치 추정을 위해 우리는 투영 기반의 등록 방법과 Uniform Arc Length Sampling(이하 UALS) 방법을 제안한다. UALS는 거리영상에서의 GSD(ground sample distance)를 균일하게 유지하면서 동시에 3차원 샘플 포인트의 수를 줄일 수 있는 장점을 가지고 있다. 또한 투영 기반 등록 기술은 3차원 대응점의 탐색 시간을 감소시킨다. 두 개의 실제 항법 경로를 이용한 실험을 통하여 제안하는 방법의 성능을 검증하였다. 3차원 점군의 다양한 샘플링에 대하여 제안하는 기술의 속도 및 정합 성능을 기존 방법과 비교하였다.

중부지방 상록지피용 기린초 속의 조경용 소재 선발 (A Selection of Korean Native Sedum spp. for Evergreen Ground Covers of the Central Districts of Korea)

  • 이선아;하유미;한인송
    • 한국조경학회지
    • /
    • 제37권5호
    • /
    • pp.90-97
    • /
    • 2009
  • 한국 자생 돌나물속 중 섬기린초는 상록성 식물로 중부 지방에서 겨울에 노지에서도 월동이 되므로 조경용 소재로 사용이 가능하였다. 섬기린초를 조경용 소재로 이용하기 위해 적심에 따른 생장특성을 조사하였다. 섬기린초의 적심작업에 따라 초장은 더욱 짧아져 조경용 지피식물로 사용하기 용이했으며, 신초지의 숫자는 늘어나는 경향이 나타났다. 2004년과 2005년에 실시한 연구에서 30% 적심처리를 한 섬기린초 처리구의 신초는 60% 적심처리를 한 처리구보다 초장은 더욱 길고 생장이 활발하였다. 노지에서 차광처리를 하지 않은 무처리구보다 70%의 차광처리를 한 섬기린초 처리구의 잎의 색은 진녹색이었고, 길이는 길어지고 신초의 수는 적게 되었다. 그러므로 기린초 종류 중 한국 자생식물인 섬기린초는 70%의 광을 차단하는 장소에도 식재 가능하며, 경기도 수원 지방에서 실험 결과, 내한성이 강한 편으로 중부지방에서도 상록성 조경 지피식물 소재로도 사용이 가능하다.

초기 지중온도 측정이 지중 열교환기 설계에 미치는 영향 (Effect of initial ground temperature measurement on the design of borehole heat exchanger)

  • 송윤호;김성균;이강근;이태종
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.600-603
    • /
    • 2009
  • We compared relative importance of thermal conductivity and initial ground temperature in designing borehole heat exchanger network and also we test accuracy of ground temperature estimation in thermal response test using a proven 3-D T-H modeler. The effect of error in estimating ground temperature on calculated total length of borehole heat exchanger was more than 3 times larger than the case of thermal conductivity in maximum 20% error range. Considering 10% of error in estimating thermal conductivity is generally acceptable, we have to define the initial ground temperature within 5% confidence level. Utilizing the mean annual ground surface temperature and the geothermal gradient map compiled so far can be a economic way of estimating ground temperature with some caution. When performing thermal response test for estimating ground temperature as well as measuring thermal conductivity, minimum 100 minutes of ambient circulation is required, which should be even more in case of very cold and hot seasons.

  • PDF

지중열교환기 설치 조건이 지중 유효 열전도도와 보어홀 열저항에 미치는 영향 (The Effects of the Installation Conditions of Ground Loop Heat Exchanger to the Thermal Conductivity and Borehole Resistance)

  • 임효재;공형진;강성재;최재호
    • 설비공학논문집
    • /
    • 제23권2호
    • /
    • pp.95-102
    • /
    • 2011
  • A ground loop heat exchanger in a ground source heat pump system is an important unit that determines the thermal performance of a system and its initial cost. A proper design requires certain site specific parameters, most importantly the ground effective thermal conductivity, the borehole thermal resistance and the undisturbed ground temperature. This study was performed to investigate the effect of some parameters such as borehole lengths, various grouting materials and U tube configurations on ground effective thermal conductivity and borehole thermal resistance. In this study, thermal response tests were conducted using a testing device to 9 different ground loop heat exchangers. From the experimental results, the length of ground loop heat exchanger affects to the effective thermal conductivity. The results of this experiment shows that higher thermal conductivity of grouting materials leads to the increase effective thermal conductivity from 22 to 32%. Also, mounting spacers have increased by 14%.

풍화암에 시공된 부력저항 앵커의 거동특성 (Characteristics of Anchor Behavior Resisting Buoyancy Forces in the Weathered Rock)

  • 유남재;이근착;정길수;박병수
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 지반공학 공동 학술발표회
    • /
    • pp.698-705
    • /
    • 2005
  • This study contains actual scaled site experiments on mediation factors affecting ultimate pulling force of the buoyancy resisting anchor which is installed underground water level suffering buoyancy force and breaking mechanism. Site buoyancy test selected the buoyancy acting site where acting buoyancy to the station structure since the stream and reservoir is neighboured to the vicinity ground and executed site experiments leading to variation of anchoring length, drilling diameter and tendon diameter at the weathered rock ground. The test result showed that pulling force getting increased more and more proportionate to increase of anchoring length, drilling diameter and tendon diameter, and as a result of analysis for correlations between anchoring length-ultimate limited load and drilling diameter-ultimate load (on the basis of 254mm settlement), modulus of correlation showed very high relation 0.9 and 0.99 respectively and correlation formular showed the limited load is increasing proportionate to cubic meters of anchoring length as well as the ultimate load proportionate to alignment of drilling diameter. It is also showed that limited load increased about 42.5% from 392kN to 559kN as a result of change the tendon diameter to 36mm and 50mm.

  • PDF

The length of plastic hinge area in the flanged reinforced concrete shear walls subjected to earthquake ground motions

  • Bafti, Farzad Ghaderi;Mortezaei, Alireza;Kheyroddin, Ali
    • Structural Engineering and Mechanics
    • /
    • 제69권6호
    • /
    • pp.651-665
    • /
    • 2019
  • Past earthquakes have shown that appropriately designed and detailed buildings with shear walls have great performance such a way that a considerable portion of inelastic energy dissipation occurs in these structural elements. A plastic hinge is fundamentally an energy diminishing means which decrease seismic input energy through the inelastic deformation. Plastic hinge development in a RC shear wall in the areas which have plastic behavior depends on the ground motions characteristics as well as shear wall details. One of the most generally used forms of structural walls is flanged RC wall. Because of the flanges, these types of shear walls have large in-plane and out-of-plane stiffness and develop high shear stresses. Hence, the purpose of this paper is to evaluate the main characteristics of these structural components and provide a more comprehensive expression of plastic hinge length in the application of performance-based seismic design method and promote the development of seismic design codes for shear walls. In this regard, the effects of axial load level, wall height, wall web and flange length, as well as various features of earthquakes, are examined numerically by finite element methods and the outcomes are compared with consistent experimental data. Based on the results, a new expression is developed which can be utilized to determine the length of plastic hinge area in the flanged RC shear walls.

Effects of different day length and wind conditions to the seedling growth performance of Phragmites australis

  • Hong, Mun Gi;Nam, Bo Eun;Kim, Jae Geun
    • Journal of Ecology and Environment
    • /
    • 제45권2호
    • /
    • pp.78-87
    • /
    • 2021
  • Background: To understand shade and wind effects on seedling traits of common reed (Phragmites australis), we conducted a mesocosm experiment manipulating day length (10 h daytime a day as open canopy conditions or 6 h daytime a day as partially closed canopy conditions) and wind speed (0 m/s as windless conditions or 4 m/s as windy conditions). Results: Most values of functional traits of leaf blades, culms, and biomass production of P. australis were higher under long day length. In particular, we found sole positive effects of long day length in several functional traits such as internode and leaf blade lengths and the values of above-ground dry weight (DW), rhizome DW, and total DW. Wind-induced effects on functional traits were different depending on functional traits. Wind contributed to relatively low values of chlorophyll contents, angles between leaf blades, mean culm height, and maximum culm height. In contrast, wind contributed to relatively high values of culm density and below-ground DW. Conclusions: Although wind appeared to inhibit the vertical growth of P. australis through physiological and morphological changes in leaf blades, it seemed that P. australis might compensate the inhibited vertical growth with increased horizontal growth such as more numerous culms, indicating a highly adaptive characteristic of P. australis in terms of phenotypic plasticity under windy environments.

특성길이 변화에 따른 200 N급 기체메탄-액체산소 소형로켓엔진의 성능 비교 분석 (A Comparative Analysis for the Performance of 200 N-class Gaseous Methane-Liquid Oxygen Small Rocket Engine According to the Characteristic Length Variation)

  • 강윤형;안현종;김정수
    • 한국추진공학회지
    • /
    • 제24권6호
    • /
    • pp.85-92
    • /
    • 2020
  • 200 N급 기체메탄-액체산소 소형로켓엔진의 연소실 특성길이 1.37 m, 1.71 m, 2.06 m에 대한 연소성능 분석을 위해 지상연소시험을 수행하였다. 로켓엔진의 주요 성능 변수로 정상상태에서의 추력, 비추력, 특성속도 등을 획득하였으며, 연소시험을 통해 확인한 성능특성을 CEA 해석으로부터 구한 이론성능과 비교 및 분석하였다. 연소성능에 대한 특성길이의 영향을 관찰한 결과, 최적의 특성길이는 1.71 m와 2.06 m사이에 존재하는 것이 확인되었다.